Three-phase A.C. <strong>motors</strong><br />
Type<br />
Construction<br />
size<br />
DEx<br />
or<br />
DDEx<br />
160M/6-4 3.8 965 9.0 37.6 6.0 2.0 0.05417 155<br />
5.7 1465 13.0 37.2 6.5 1.8<br />
160L/6-4 5.5 980 13.3 53.6 7.0 2.1 0.07116 197<br />
8 1480 16.8 51.6 7.0 2.0<br />
180M/6-4 7.5 980 16.6 73.1 6.3 2.0 0.1129 220<br />
11 1470 22 71.5 6.5 1.6<br />
180L/6-4 9 980 20 87.7 6.5 2.0 0.1339 240<br />
13 1470 26 84.5 7.0 1.5<br />
200L/6-4 13 980 31 127 6.8 2.1 0.21298 260<br />
19 1470 39 123 7.2 2.2<br />
225S/6-4 19 980 40 185 6.0 2.0 0.36225 320<br />
23 1470 48 149 6.3 2.2<br />
225M/6-4 23 980 48 224 6.0 2.1 0.42845 400<br />
27 1470 56 175 6.5 2.0<br />
250M/6-4 27 980 53 263 6.0 2.1 0.875 490<br />
32 1470 65 208 6.5 2.2<br />
280S/6-4 32 985 63 310 6.5 2.3 1.875 610<br />
45 1475 89 291 7.0 2.7<br />
280M/6-4 37 985 72 359 6.5 2.3 2.25 685<br />
55 1475 108 356 7.0 2.7<br />
315S/6-4 45 985 88 436 6.8 2.1 3.9 820<br />
67 1485 130 431 7.2 2.3<br />
315M/6-4 55 985 108 533 6.8 2.1 3.875 930<br />
HEW DEx series<br />
Nominal<br />
output<br />
P N<br />
kW<br />
Nominal<br />
speed<br />
n N<br />
min -1<br />
Nominal<br />
current<br />
(400V)<br />
I N<br />
A<br />
Nominal<br />
torque<br />
80 1485 155 515 7.2 2.3<br />
M N<br />
Nm<br />
Starting<br />
to nominal<br />
current<br />
I A / I N<br />
Breakdown<br />
to nominal<br />
torque<br />
M K / M N<br />
Moment<br />
of<br />
torque<br />
J M<br />
kgm²<br />
Weight<br />
approx. kg<br />
3/4<br />
3