<strong>Universal</strong> Systems<br />

One layer<br />

mechanically fastened<br />

Substrate<br />

Steel<br />

Timber (boarding / plywood)<br />

Concrete<br />

Existing roof surface<br />

Vapour control layer<br />

Depending on condensation risk calculation<br />

Apply according to local practice<br />

Laps depending on type of VCL: Generally longitudinal<br />

laps 100 mm, head laps 100 mm<br />

Insulation<br />

Install <strong>Esha</strong>Therm insulation according to local practice in<br />

broken bond<br />

Waterproofing<br />

ESHA UNIVERSAL mechanically with <strong>Esha</strong> fasteners, every<br />

250 mm or as local conditions / regulations<br />

Edge and corner-zones, where wind load calculations<br />

demands exceed 4 fasteners per metre, use band + strip<br />

method (see standard details)<br />

Weld laps with <strong>Esha</strong>Weld hot-air machine: longitudinal<br />

laps 130 mm head laps 100 mm<br />

Apply ESHA UNIVERSAL with a minimum of 50 mm to<br />

upstands<br />

Flashing of ESHA UNIVERSAL minimum 150 mm onto<br />

vertical and 150 mm to flat<br />

Note: Where the building exceeds 30 metres high, install<br />

an attachment layer of <strong>Esha</strong>Base Sanded with special <strong>Esha</strong><br />

fasteners, longitudinal laps 70 mm, head laps 100 mm,<br />

according to local regulations. Fully bond ESHA UNIVERSAL<br />

to <strong>Esha</strong>Base with ESHA UNIVERSAL Cold Adhesive. Weld laps<br />

with <strong>Esha</strong>Weld hot-air machine: longitudinal laps 80 mm<br />

head laps 100 mm.<br />

One layer<br />

loose laid ballasted<br />

Substrate<br />

Steel<br />

Timber (boarding / plywood)<br />

Concrete<br />

Existing roof surface<br />

Vapour control layer<br />

Depending on condensation risk calculation<br />

Apply according to local practice<br />

Laps depending on type of VCL: Generally longitudinal<br />

laps 100 mm, head laps 100 mm<br />

Insulation<br />

Install <strong>Esha</strong>Therm insulation according to local practice in<br />

broken bond<br />

Waterproofing<br />

Loose lay <strong>Esha</strong> <strong>Universal</strong><br />

Weld laps with <strong>Esha</strong>Weld hot-air machine: longitudinal<br />

laps 80 mm, head laps 100 mm<br />

Apply <strong>Esha</strong> <strong>Universal</strong> with a minimum of 50 mm to<br />

upstands<br />

Flashing of <strong>Esha</strong> <strong>Universal</strong> minimum 150 mm to vertical<br />

face and 150 mm to roof surface<br />

Ballast<br />

Install pebbles or paving on pads according to local<br />

preferences/regulations<br />

Note: At the end of its service life <strong>Esha</strong> <strong>Universal</strong> can be<br />

easily overlaid<br />

One layer loose laid ballasted<br />

as inverted roof<br />

Substrate<br />

Steel<br />

Timber (boarding / plywood)<br />

Concrete<br />

Existing roof surface<br />

Waterproofing membrane<br />

Loose lay ESHA UNIVERSAL<br />

Thermally weld laps with hot-air welding machine or<br />

overlap torch: longitudinal laps 80 mm and head laps<br />

100 mm<br />

Insulation<br />

Install <strong>Esha</strong>Therm insulation according to local practice in<br />

broken bond<br />

Waterproofing<br />

Loose lay ESHA UNIVERSAL<br />

Weld laps with <strong>Esha</strong>Weld hot-air machine: longitudinal<br />

laps 80 mm head laps 100 mm<br />

Apply ESHA UNIVERSAL with a minimum of 50 mm to<br />

upstands<br />

Flashing of ESHA UNIVERSAL minimum 150 mm to vertical<br />

face and 150 mm to roof surface<br />

Ballast<br />

Install pebbles or paving on pads according to local<br />

preferences/regulations<br />

Note: At the end of its service life ESHA UNIVERSAL can<br />

be easily overlaid<br />

One layer overlay<br />

cold adhesive<br />

Substrate<br />

Existing roof surface<br />

Pre-treatment<br />

Dry, level and clean existing roof surface<br />

Coat the existing roof surface with <strong>Esha</strong>Prime<br />

Vapour control layer<br />

Depending on condensation risk calculation<br />

Apply according to local practice<br />

Laps depending on type of VCL: Generally longitudinal<br />

laps 100 mm, head laps 100 mm<br />

Insulation<br />

Install <strong>Esha</strong>Therm insulation according to local practice in<br />

broken bond<br />

Waterproofing<br />

Adhere <strong>Esha</strong> <strong>Universal</strong> fully with <strong>Esha</strong> <strong>Universal</strong> Cold<br />

Adhesive<br />

Apply <strong>Esha</strong> <strong>Universal</strong> Cold Adhesive with a hard rubber<br />

squeegee (usage 800-1000 gr/m2)<br />

Apply <strong>Esha</strong> universal with staggered end laps<br />

Thermally weld laps with <strong>Esha</strong>Weld hot-air machine:<br />

longitudinal laps 80 mm head laps 100 mm<br />

Apply <strong>Esha</strong> <strong>Universal</strong> with a minimum of 50 mm to<br />

upstand<br />

Flashing of <strong>Esha</strong> <strong>Universal</strong> minimum 150 mm to vertical<br />

150mm to flat