_____________________________________________________________________________________________________________ Seite 1/4<br />

<strong>Rittal</strong><br />

<strong>CS</strong><br />

Schaltschrank-<br />

Heizung<br />

Enclosure heater<br />

<strong>CS</strong> <strong>9769</strong> <strong>015</strong><br />

Montageanleitung<br />

Assembly instructions


Contents<br />

1. Application<br />

2. Technical specifications<br />

3. Assembly instructions<br />

4. Electrical connection<br />

5. Maintenance<br />

5.1 General<br />

5.2 Cleaning the enclosure heater<br />

6. Supply includes<br />

7. Approvals<br />

1. Application<br />

Enclosure heaters have been developed and designed to prevent condensation and facilitate the<br />

permanent circulation of air. This helps to prevent the formation of hot spots. The enclosure heater is<br />

designed to be fitted in either a vertical or horizontal position.<br />

2. Technical data<br />

Model No. <strong>CS</strong> <strong>CS</strong> <strong>9769</strong> <strong>015</strong><br />

Rated operating voltage V/Hz 230 V (AC) / 50 / 60<br />

Rated current 5 A (AC)<br />

Pre-fuse (type T=slow) 6 A<br />

Dimensions in mm W<br />

H<br />

D<br />

325<br />

83<br />

220<br />

Material Aluminium<br />

Thermal output 1000 W<br />

Air throughput of fans (unimpeded<br />

airflow)<br />

480 m³/h<br />

Number of fans per unit 1<br />

Temperature range Storage: -33°C bis +65°C<br />

max. air inlet temperature:<br />

+25 °C<br />

Weight (incl. cover) 2,8 kg<br />

Type of connection via connection cable with<br />

wire end ferrules<br />

Special voltages available on request/ Technical modifications reserved.


3. Assembly instructions<br />

Prior to mounting, ensure that<br />

• the site of the enclosure and hence the arrangement of the enclosure heater, is selected in such a<br />

way as to ensure good ventilation;<br />

• the location is free from excessive dirt and moisture;<br />

• the mains connection ratings, as stated on the name plate of the unit, are available;<br />

• the ambient temperature does not exceed +65°C;<br />

• the packaging does not show any signs of damage;<br />

• all components are adequately secured:<br />

• the contact surfaces are clean and even;<br />

• air inlet and outlet are not obstructed on the inside of the enclosure;<br />

• electrical connection and repairs must only be carried out by authorised, qualified staff; use only<br />

original spare parts!<br />

diagram 3.1 Enclosure heater<br />

Safety instructions<br />

,<br />

! Make sure that no flammable gases or readily inflammable components come into contact with, or<br />

are extracted by, the enclosure heater.<br />

! Make sure that there is sufficient space for ventilation around the enclosure heater.


4. Electrical connection<br />

• The connection voltage and frequency must match the nominal values specified on the<br />

rating plate.<br />

• The heater module does not contain ist own heater module should be connected to the<br />

mains via a dsconnecting device which guarantees a contact opening of at least 3 mm in<br />

the deactivated state, e.g. a motor circuit-breaker.<br />

• The PE condutor must be connected.<br />

• An additional temperature control may be connected upstream of the device at the<br />

supply end.<br />

• The device does not contain its own electrical fuse; consequently, the pre-fuse specified<br />

on the rating plate must be provided as line protection<br />

• Typenschild angegebene Vorsicherung vorgesehen werden.<br />

Please observe the locally valid refulations when installing!<br />

• Make the AC connection using a 3-wire cable with wire end ferrules (crimp connection)<br />

brown = L<br />

blue = N<br />

green/yellow = PE<br />

5. Maintenance<br />

5.1 General<br />

• Depending on the level of contamination of the ambient air, the unit must be serviced at<br />

least twice a year.<br />

• Cleaning, maintenance and repair work to the unit must only be carried out by<br />

authorised, trained staff.<br />

• Before carrying out any repair work, the system must be disconnected from the mains<br />

• Only original spare parts must be used.<br />

5.2 Cleaning the enclosure heater<br />

If contaminated with dry dust, blowing out with compressed air is sufficient for cleaning purposes.<br />

6. Supply includes<br />

1 heater module, ready for connection,<br />

1 set of assembly and operating instuctions<br />

7. Approvals<br />

the units comply with the provisions for attaining the CE-symbol:<br />

• Low voltage directive (NSR) 73/23 EWG und 93/68 EEC<br />

• EN 60950<br />

• EN 55 022 Klasse B<br />

• EN 50082-2