LED displays<br />
ATLC 670-0<br />
LED display LED operating status Function<br />
LED 1 off no operating voltage<br />
lights up in green operating voltage applied<br />
Link lights up in green connection to switch exists<br />
flashes green data communication with the device<br />
off no connection to the switch<br />
Status lights up in green Vario bus ready for operation<br />
flashes green data communication in the Vario bus<br />
Error/OK lights up briefly in green after Power On for around 5 secs.<br />
flashes green during ramp-up, flashing starts up<br />
appr. 20 secs. after Power On<br />
lights up in green ATLC is logged in at the server<br />
lights up in red error logging into server<br />
A1 lights up in green output 1 HIGH (DR)<br />
off output 1 LOW (DR)<br />
A2 lights green output 2 HIGH<br />
off output 2 LOW<br />
A3 lights up in green output 3 HIGH (LI)<br />
off output 3 LOW<br />
E lights up in green input 1 HIGH (LI)<br />
off input 1 LOW<br />
46<br />
ATLC 670-0<br />
<strong>Access</strong> Türlautsprecher-Controller<br />
<strong>Access</strong> Door loudspeaker controller<br />
<strong>Access</strong> Contrôleur de platine de rue<br />
IP 20<br />
SN 0000000000<br />
LED 1<br />
23 24 13 14 15 16 17 18 S1 S2 S3 S4 D1 D2 V1 V2<br />
Output Input ATLM/ACM<br />
Link<br />
Status<br />
Error / OK<br />
A1 A2 A3 E