LED displays<br />

ATLC 670-0<br />

LED display LED operating status Function<br />

LED 1 off no operating voltage<br />

lights up in green operating voltage applied<br />

Link lights up in green connection to switch exists<br />

flashes green data communication with the device<br />

off no connection to the switch<br />

Status lights up in green Vario bus ready for operation<br />

flashes green data communication in the Vario bus<br />

Error/OK lights up briefly in green after Power On for around 5 secs.<br />

flashes green during ramp-up, flashing starts up<br />

appr. 20 secs. after Power On<br />

lights up in green ATLC is logged in at the server<br />

lights up in red error logging into server<br />

A1 lights up in green output 1 HIGH (DR)<br />

off output 1 LOW (DR)<br />

A2 lights green output 2 HIGH<br />

off output 2 LOW<br />

A3 lights up in green output 3 HIGH (LI)<br />

off output 3 LOW<br />

E lights up in green input 1 HIGH (LI)<br />

off input 1 LOW<br />

46<br />

ATLC 670-0<br />

<strong>Access</strong> Türlautsprecher-Controller<br />

<strong>Access</strong> Door loudspeaker controller<br />

<strong>Access</strong> Contrôleur de platine de rue<br />

IP 20<br />

SN 0000000000<br />

LED 1<br />

23 24 13 14 15 16 17 18 S1 S2 S3 S4 D1 D2 V1 V2<br />

Output Input ATLM/ACM<br />

Link<br />

Status<br />

Error / OK<br />

A1 A2 A3 E