Mixed systems<br />
For mixed systems is the concrete layer 4 to 5 cm thick. Recommended mat<br />
output is 160 W/ m2. For this systems is suitable rate D 34, D35, D36 when<br />
the possibility of storage is 16 hours daily for low rate. Next 8 hours is<br />
the stored heat being radiated from the surface of the floor.<br />
Suitable solution is to divide the total output in ratio 70% floor heating<br />
and 30% electric convector or heating panel ECOSUN. It is possible to use<br />
mats ECOFLOOR with output 100 W/ m2 for this solution.<br />
Joint to fill<br />
with silicone<br />
mastic or to use<br />
dilatation<br />
profile<br />
Dilatation belt around a rooms<br />
circumference<br />
Elastic jointing substance<br />
Tiles<br />
Elastic mastic<br />
Concrete layer 4 - 5 cm<br />
Ecofloor<br />
Heat insulation, extruded<br />
polystyrene min 5 cm.<br />
Hydro-insulation, necessary only<br />
when there is a heat insulation<br />
Direct heating electric systems<br />
It is a modern system of floor heating allowing very good adjustability. Heat mats<br />
are being located in a thin layer of elastic mastic on a concrete layer 3-4 cm thick.<br />
For heating-up is suitable to use direct heat rate D45, D46, D55- 20 hours/day cheap<br />
tariff. ( prices ČR see www.sme.cz ).<br />
Direct heating system enables flexible reaction on demand of temperature change. Mat<br />
is located directly under the tiles therefore the heating process is relatively fast.<br />
Significant advantage is the fact, that all other home appliances work in the cheaper<br />
tariff. Total receipt for all electricity ( heating + other home appliances ) is<br />
favourable.<br />
Heating mats ECOFLOOR D,DT,DTS and T are designed for electric direct heating floor<br />
systems.<br />
Mats are produced in two output versions 160 W/m2 and 100 W/m2.<br />
ECOFLOOR D,DTS,T mats are equipped with protection screening for use in rooms where<br />
it is can be required from safety point of view – laundry, bathrooms, humid rooms.<br />
ECOFLOOR DT mats do not have protection screening. These mats are installed in rooms<br />
where it is not necessary to have increased protection in form of protection<br />
screening – corridors, living rooms, halls etc.