16<br />

Installation of electric storage and mixed<br />

floor heatings ECOFLOOR<br />

Storage floor<br />

On the heating insulation wchich consists of layer of extruded styrofoam ( or normal<br />

styrofoam with quality 25kg/m3) of<br />

width min 8cm is placed layer of concrete wchich thickness correspondence width 1/3<br />

of total thickness of concrete floor layer. (Total floor layer of concrete has to be<br />

about 10-14cm.) On the first concrete layer put the heating mat ECOFLOOR in<br />

accordance with plan of possition. After measuring of electrical parameters of<br />

heating mat is immediately placed second layer of concrete which correspondence with<br />

2/3 of total thickness of concrete floor layer. Do not use any submergible vibrators<br />

for firming of concrete. During putting of concrete layer be also carefull of demage<br />

of cable. After finishing of concrete layer measure again electrical parameters of<br />

heating cable. Heating system switch on at first 28 days after the pouring of<br />

concrete at the earliest. We recommend that you use permanently elastic cement to<br />

glue the tiling-one that its manufacturers recommend for use with heating floors.<br />

(see chapter Materials for tiles installation… ).<br />

For storage systems the concrete layer is 10-14 cm thick. Mat output is 250 to 300<br />

W/m2.<br />

1. base<br />

2. thermal insulation (extruded polystyrene)<br />

3. KARI steel mesh<br />

4. ECOFLOOR heating mat<br />

5. concrete storage layer, 12-14 cm thick<br />

6. protective tube for floor probe<br />

7. layer that is walked upon (tiling, thick carpet, parquet floor, PVC<br />

without rubber base)