6 PT/03/BD1076/R Revision 2<br />

Step 1: Express fuel moisture and unburned carbon in<br />

terms of molecular weight of SMAF coal using guessed<br />

coal analysis.<br />

Step 2: Determine first approximation of coal analysis<br />

using CEMS data on CO2, SO2 and O2.<br />

Step 3: Determine all terms in the combustion equation.<br />

Step 4: Calculate mass of flue gas and mass of air per unit mass<br />

of coal. Divide total air flow into its components. Perform<br />

energy balance on boiler and obtain heat transfer to steam per<br />

unit mass of coal and losses per unit mass of coal.<br />

Step 5: Calculate coal flow rate and Higher Heating Value<br />

(HHV) of the coal.<br />

Step 6: Is the difference between calculated HHV and<br />

input HHV less than 0.1%?<br />

YES<br />

Step 7: Output coal flow rate, efficiency, boiler<br />

efficiency, coal composition and higher heating rate.<br />

Figure 4.3 Procedure for the On-Line Heat Rate Calculation