KFZSD 1”/1.5” <strong>Manual</strong> 01/04 Rev. 1 SHUTDOWN AND STORAGE<br />

4.0 SHUTDOWN AND STORAGE<br />

If the system must be shut down <strong>and</strong> stored, per<strong>for</strong>m the following steps.<br />

4.1 SHUTDOWN AND STORAGE PROCEDURE<br />

A. Regenerate the unit<br />

B. When the system returns to Service, close all valves in the inlet <strong>and</strong> outlet piping.<br />

C. Disconnect the power to the controller.<br />

D. Once each week, open the inlet valve <strong>and</strong> put the unit into Rapid Rinse <strong>for</strong> 10 minutes;<br />

power must be restored to do this. Once complete, repeat steps B <strong>and</strong> C.<br />

E. When the softener is returned to Service, re-open the inlet <strong>and</strong> outlet valves, restore<br />

power to the controller, <strong>and</strong> regenerate the unit again<br />