I GENERAL<br />

1.1 WARNING<br />

I. DISCONNECT POWER BEFORE REMOVING COVER.<br />

2. TO PREVENT IGNITION OF HAZARDOUS ATMOSPHERES,<br />

DISCONNECT SUPPLY CIRCUIT BEFORE OPENING UNIT.<br />

KEEP ASSEMBLY TIGHTLY CLOSED WHEN IN OPERATION.<br />

3. TO MAINTAIN THE HAZARDOUS LOCATION RATING OF<br />

<strong>EJ</strong>X <strong>ACTUATORS</strong>, IT IS ESSENTIALTHAT MATING SURFACES<br />

OF FLANGES BE PROTECTED FROM NICKS AND SCRATCHES<br />

WHILE DISASSEMBLED. UPON REASSEMBLY, THERE MUST BE<br />

NO DIRT OR PARTICLES ON THE MATING SURFACES OR<br />

FLANGES.<br />

4. BEFORE INSTALLING THE VALVE AND ACTUATOR, BE<br />

SURE THAT THE INDICATOR POINTER ON TOP OF THE<br />

ACTUATOR IS CORRECTLY INDICATING THE VALVES PO-<br />

SITION. FAILURE TO ASSEMBLE THESE PRODUCTS TO INDI-<br />

CATE CORRECT VALVE POSITION COULD RESULT IN<br />

PERSONAL INJURY.<br />

1.2 OPERATING INSTRUCTION<br />

Normal operating voltages for electric actuators: 115 VAC, 230<br />

VAC as specified on the actuator. Refer to Product Bulletin A120-2<br />

for torque output, duty cycle and operating speed. See wiring<br />

diagram for proper wiring. Operating temperature range is -40°F<br />

to +120°F however, below +40° F the heater option is required.<br />

MOUNTING INSTRUCTIONS<br />

I/4" - 2" A, AF & B Style Valves AMI-I<br />

l/4" - 2" CLINCHER@ Valves AMI-2<br />

I-l/2" - 2" A, AF, B Style Valves AMI-3<br />

l/4" - 2" HP/HT Valves AMI-5<br />

I/4" - 2" Series 5000 Valves AMI-8<br />

3" - 4" 5150, 3" - 4" 5300, 2" - 3" 6150<br />

2" - 3" 6300 AMI-9<br />

1/2" - 2" Series 4000 Valves AMI-10<br />

Butterfly Valves (See Valve <strong>IMO</strong>)<br />

To obtain copies of these, contact your nearest Neles-Jamesbury<br />

stocking distributor or write: Neles-Jamesbury, Inc., Box 15004,<br />

640 Lincoln Street, Worcester, Massachusetts 01615-0004, U.S.A.<br />

CAUTION<br />

2 INSTALLATION CAUTION<br />

2.1 General<br />

Mount these actuators by following actuator mounting instructions<br />

contained in the following AMI’s:<br />

WIRING OF THE <strong>EJ</strong>/<strong>EJ</strong>X (<strong>MODEL</strong> G) ACTUATOR<br />

WHENEVER AN ACTUATOR IS REMOVED FROM THE<br />

VALVE AND THEN REMOUNTED, THE LIMIT SWITCHES<br />

MUST BE READJUSTED. SEE ADJUSTMENT SECTION.<br />

WHEN SERVICING A VALVE/ACTUATOR ASSEMBLY, THE<br />

BEST PRACTICE IS TO REMOVE THE ENTIRE ASSEMBLY<br />

FROM SERVICE.<br />

BEFORE PERFORMING ANY MAINTENANCE TO THIS AC-<br />

TUATOR, DISCONNECT INCOMING POWER AND UN-<br />

PLUG THE CAPACITOR FROM THE BASIC BOARD.<br />