Mounting and operating instructions <strong>AMTRON</strong> R○ X-<strong>50</strong><br />

System loop<br />

The following values can be displayed in the system loop:<br />

SYStEM<br />

Editing methods<br />

FNr 12345678<br />

SYS H-<strong>50</strong><br />

DAT 18.12.05<br />

FW 1.05.00<br />

HW 2.01.10.00<br />

Fabrication No. of the instrument<br />

Version of the device<br />

Date of manufacture<br />

Firmware version<br />

Hardware version<br />

The following examples show the editing methods in Service mode [S-Edit].<br />

For non calibrated totalisers it is possible to adjust values, digits and sign (+/-) in Program mode [P-Edit] too.<br />

Number entry<br />

If it is possible to adjust a (multi-) digit in an operating loop, then follow the procedure in the graphic bellow:<br />

S-Edit<br />

ImP 1.000 kWh<br />

ImP 0001.000 1<br />

ImP 0001.000 2<br />

ImP 0001.000 7<br />

Activate Service Mode with Service key<br />

Press Enter key to enter in Edit mode<br />

Adjust the digit (1) with the Select key<br />

Change to next digit (2) with the Enter key<br />

Adjust the digit with the Select key<br />

:<br />

:<br />

Change to last digit (7) with the Enter key<br />

Adjust the digit with the Select key<br />

Finish the entry with the Enter key<br />

The values and digits can be adjusted in their possible range from 1 to 8 digits between 0 and 9. Partly the sign (+/-)<br />

can be set.<br />

VD 3-248 e 03.2006 20 Aquametro AG