<str<strong>on</strong>g>Heat</str<strong>on</strong>g> <str<strong>on</strong>g>Transfer</str<strong>on</strong>g> <str<strong>on</strong>g>and</str<strong>on</strong>g> <str<strong>on</strong>g>Visualizati<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>Falling</str<strong>on</strong>g> <str<strong>on</strong>g>Film</str<strong>on</strong>g> <str<strong>on</strong>g>Evaporati<strong>on</strong></str<strong>on</strong>g><br />

<strong>on</strong> a Tube Bundle<br />

THÈSE N O 4840 (2010)<br />

PRÉSENTÉE LE 11 NOVEMBRE 2010<br />

À LA FACULTÉ SCIENCES ET TECHNIQUES DE L'INGÉNIEUR<br />

LABORATOIRE DE TRANSFERT DE CHALEUR ET DE MASSE<br />

PROGRAMME DOCTORAL EN ENERGIE<br />

ÉCOLE POLYTECHNIQUE FÉDÉRALE DE LAUSANNE<br />

POUR L'OBTENTION DU GRADE DE DOCTEUR ÈS SCIENCES<br />

PAR<br />

Marcel CHRISTIANS<br />

acceptée sur propositi<strong>on</strong> du jury:<br />

Pr<str<strong>on</strong>g>of</str<strong>on</strong>g>. F. Avellan, président du jury<br />

Pr<str<strong>on</strong>g>of</str<strong>on</strong>g>. J. R. Thome, directeur de thèse<br />

Pr<str<strong>on</strong>g>of</str<strong>on</strong>g>. P. Di Marco, rapporteur<br />

Pr<str<strong>on</strong>g>of</str<strong>on</strong>g>. D. Favrat, rapporteur<br />

Pr<str<strong>on</strong>g>of</str<strong>on</strong>g>. P. Stephan, rapporteur<br />

Suisse<br />

2010


Abstract<br />

Horiz<strong>on</strong>tal falling film evaporators have the potential <str<strong>on</strong>g>of</str<strong>on</strong>g> displacing flooded evaporators<br />

in industry, due to advantages such as lower required refrigerant charge <str<strong>on</strong>g>and</str<strong>on</strong>g> lower<br />

pressure drop. However, there is a need to improve the underst<str<strong>on</strong>g>and</str<strong>on</strong>g>ing <str<strong>on</strong>g>of</str<strong>on</strong>g> falling film<br />

evaporati<strong>on</strong> mechanisms to provide accurate thermal design methods.<br />

In this work, the existing LTCM falling film facility was utilized to perform falling<br />

film evaporati<strong>on</strong> measurements <strong>on</strong> a single tube, a vertical row <str<strong>on</strong>g>of</str<strong>on</strong>g> horiz<strong>on</strong>tal tubes <str<strong>on</strong>g>and</str<strong>on</strong>g><br />

a small tube bundle. Two enhanced boiling tubes, namely the Wolverine Turbo-B5 <str<strong>on</strong>g>and</str<strong>on</strong>g><br />

the Wiel<str<strong>on</strong>g>and</str<strong>on</strong>g> Gewa-B5, were tested using R-134a <str<strong>on</strong>g>and</str<strong>on</strong>g> R-236fa. The tests were carried<br />

out at a c<strong>on</strong>stant saturati<strong>on</strong> temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> Tsat = 5 ◦ C, liquid film Reynolds numbers<br />

ranging from 0 to 3000, <str<strong>on</strong>g>and</str<strong>on</strong>g> heat fluxes between 15 <str<strong>on</strong>g>and</str<strong>on</strong>g> 90 kW/m 2 in pool boiling<br />

<str<strong>on</strong>g>and</str<strong>on</strong>g> falling film c<strong>on</strong>figurati<strong>on</strong>s. A visualizati<strong>on</strong> study was performed under adiabatic<br />

<str<strong>on</strong>g>and</str<strong>on</strong>g> diabatic c<strong>on</strong>diti<strong>on</strong>s (in both single-array <str<strong>on</strong>g>and</str<strong>on</strong>g> bundle c<strong>on</strong>figurati<strong>on</strong>s) to study the<br />

flow. The physical phenomena governing the falling film evaporati<strong>on</strong> process have been<br />

studied, <str<strong>on</strong>g>and</str<strong>on</strong>g> insight into their effects <strong>on</strong> the performance <str<strong>on</strong>g>of</str<strong>on</strong>g> tube bundles has been<br />

gained.<br />

Measurements <str<strong>on</strong>g>of</str<strong>on</strong>g> the local heat transfer coefficient were obtained <str<strong>on</strong>g>and</str<strong>on</strong>g> utilized to<br />

generate new predicti<strong>on</strong> methods, including a method for predicting the <strong>on</strong>set-<str<strong>on</strong>g>of</str<strong>on</strong>g>-dryout<br />

film flow rate during falling film evaporati<strong>on</strong>, local pool boiling <str<strong>on</strong>g>and</str<strong>on</strong>g> falling film heat<br />

transfer predicti<strong>on</strong> methods <str<strong>on</strong>g>and</str<strong>on</strong>g> a falling film multiplier predicti<strong>on</strong> method.<br />

Keywords: falling film evaporati<strong>on</strong>, pool boiling, enhanced boiling, heat transfer,<br />

two-phase flow, flow visualizati<strong>on</strong>, Wils<strong>on</strong> plot<br />

i


Versi<strong>on</strong> abrégée<br />

Les évaporateurs à film tombant <strong>on</strong>t le potentiel de déplacer les évaporateurs in<strong>on</strong>dés<br />

dans l’industrie, dû aux avantages tels que la charge réfrigérante requise inférieure et la<br />

chute de pressi<strong>on</strong> inférieure. Il est nécessaire d’améliorer au préalable la c<strong>on</strong>naissance<br />

des mécanismes d’évaporati<strong>on</strong> en film pour fournir des méthodes performantes de<br />

dimensi<strong>on</strong>nement pour ces échangeurs.<br />

L’installati<strong>on</strong> expérimentale pour les échanges en film tombant du LTCM a été<br />

utilisée pour faire des mesures d’ébulliti<strong>on</strong> sur un tube, une col<strong>on</strong>ne de tubes horiz<strong>on</strong>taux<br />

et un faisceau de tubes. Deux tubes améliorés, le Wolverine Turbo-B5 et le Wiel<str<strong>on</strong>g>and</str<strong>on</strong>g><br />

Gewa-B5 furent testés en utilisant R-134a et R-236fa. Les essais <strong>on</strong>t été effectués à une<br />

température de saturati<strong>on</strong> c<strong>on</strong>stante Tsat = 5 ◦ C, des nombres de Reynolds compris entre<br />

0 et 3000, des densités de flux de chaleur entre 15 et 90 kW/m 2 pour ébulliti<strong>on</strong> en vase<br />

et évaporati<strong>on</strong> en film tombant. Une étude de visualizati<strong>on</strong> fut éffectuée en c<strong>on</strong>diti<strong>on</strong>s<br />

adiabatiques et diabatiques pour étudier l’écoulement. Les phénomènes physiques qui<br />

régissent le processus d’ébulliti<strong>on</strong> en film tombant <strong>on</strong>t été étudiés, et la compréhensi<strong>on</strong><br />

des ces phénomènes et leurs influence sur la performance des évaporateurs à film tombant<br />

a été améliorée.<br />

Des mesures du coefficient de transfert de chaleur <strong>on</strong>t été obtenues et utilisées pour<br />

produire des méthodes de prédicti<strong>on</strong>, y compris une méthode pour prévoir l’appariti<strong>on</strong><br />

de la formati<strong>on</strong> de z<strong>on</strong>es sèches, des méthodes pour évaporati<strong>on</strong> en vase et en film<br />

tombant et une méthode pour le Kff.<br />

Mots clés: évaporati<strong>on</strong> en film tombant, ébulliti<strong>on</strong> en vase, ébulliti<strong>on</strong> améliorée,<br />

transfert de chaleur, écoulement biphasique, visualizati<strong>on</strong>, méthode de Wils<strong>on</strong><br />

iii


C<strong>on</strong>tents<br />

Abstract . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i<br />

Versi<strong>on</strong> abrégée . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iii<br />

Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii<br />

List <str<strong>on</strong>g>of</str<strong>on</strong>g> Figures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xv<br />

List <str<strong>on</strong>g>of</str<strong>on</strong>g> Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxi<br />

Nomenclature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . xxiii<br />

1 Introducti<strong>on</strong> 1<br />

1.1 Background . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1<br />

1.2 Motivati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the study . . . . . . . . . . . . . . . . . . . . . . . . . . . 2<br />

1.3 Objectives <str<strong>on</strong>g>of</str<strong>on</strong>g> the study . . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />

1.4 Layout <str<strong>on</strong>g>of</str<strong>on</strong>g> the dissertati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . 3<br />

2 Literature survey 5<br />

2.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5<br />

2.2 Mechanics <str<strong>on</strong>g>of</str<strong>on</strong>g> falling film flows . . . . . . . . . . . . . . . . . . . . . . . 5<br />

2.2.1 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film inter-tube modes <str<strong>on</strong>g>and</str<strong>on</strong>g> transiti<strong>on</strong>s . . . . . . . . . . . 5<br />

2.2.2 <str<strong>on</strong>g>Film</str<strong>on</strong>g> breakdown . . . . . . . . . . . . . . . . . . . . . . . . . . . 7<br />

2.2.3 Vapor–liquid interacti<strong>on</strong>s in tube bundles . . . . . . . . . . . . . 8<br />

2.3 <str<strong>on</strong>g>Heat</str<strong>on</strong>g> transfer mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

2.4 Natural c<strong>on</strong>vecti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10<br />

2.5 Nucleate pool boiling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11<br />

2.6 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film enhancement . . . . . . . . . . . . . . . . . . . . . . . . . . 12<br />

2.7 Single-array heat transfer studies . . . . . . . . . . . . . . . . . . . . . . 13<br />

2.7.1 Saturati<strong>on</strong> temperature effect . . . . . . . . . . . . . . . . . . . . 13<br />

2.7.2 <str<strong>on</strong>g>Heat</str<strong>on</strong>g> flux effect . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

ix


CONTENTS<br />

2.7.3 Flow rate effect . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14<br />

2.7.4 Tube diameter effect . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

2.7.5 Liquid feeder effect . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

2.7.6 Vapor flow effect . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<br />

2.7.7 Enhanced surfaces . . . . . . . . . . . . . . . . . . . . . . . . . . 16<br />

2.8 Tube bundle heat transfer studies . . . . . . . . . . . . . . . . . . . . . . 17<br />

2.9 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film heat transfer predicti<strong>on</strong> methods . . . . . . . . . . . . . . . 19<br />

2.10 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25<br />

3 Experimental set-up 27<br />

3.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

3.2 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film test facility . . . . . . . . . . . . . . . . . . . . . . . . . . . 27<br />

3.2.1 Refrigerant circuit . . . . . . . . . . . . . . . . . . . . . . . . . . 29<br />

3.2.2 Water circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30<br />

3.2.3 Water-glycol circuit . . . . . . . . . . . . . . . . . . . . . . . . . 32<br />

3.3 Test secti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33<br />

3.3.1 Liquid distributi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . 34<br />

3.3.2 Tube layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

3.4 Bundle modificati<strong>on</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36<br />

3.5 Measurement procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . 38<br />

3.6 Refrigerants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39<br />

3.7 Data acquisiti<strong>on</strong> <str<strong>on</strong>g>and</str<strong>on</strong>g> c<strong>on</strong>trol . . . . . . . . . . . . . . . . . . . . . . . . 39<br />

3.7.1 Data acquisiti<strong>on</strong> system . . . . . . . . . . . . . . . . . . . . . . . 39<br />

3.7.2 C<strong>on</strong>trol system . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

3.8 Measurements <str<strong>on</strong>g>and</str<strong>on</strong>g> accuracy . . . . . . . . . . . . . . . . . . . . . . . . 41<br />

3.8.1 Instrumentati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the test secti<strong>on</strong> . . . . . . . . . . . . . . . . . 41<br />

3.8.2 Physical properties estimati<strong>on</strong> . . . . . . . . . . . . . . . . . . . 42<br />

3.8.3 Saturati<strong>on</strong> temperature . . . . . . . . . . . . . . . . . . . . . . . 42<br />

3.8.4 Mass flow meters . . . . . . . . . . . . . . . . . . . . . . . . . . 43<br />

3.8.5 Water temperature pr<str<strong>on</strong>g>of</str<strong>on</strong>g>ile . . . . . . . . . . . . . . . . . . . . . 43<br />

3.8.6 Local heat flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45<br />

3.8.7 <str<strong>on</strong>g>Film</str<strong>on</strong>g> Reynolds number . . . . . . . . . . . . . . . . . . . . . . . 46<br />

3.9 <str<strong>on</strong>g>Visualizati<strong>on</strong></str<strong>on</strong>g> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46<br />

x


CONTENTS<br />

3.9.1 Single-array visualizati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . 46<br />

3.9.2 Bundle visualizati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . 47<br />

3.10 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48<br />

4 Wils<strong>on</strong> plot method 49<br />

4.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49<br />

4.2 <str<strong>on</strong>g>Heat</str<strong>on</strong>g> transfer calculati<strong>on</strong> principles . . . . . . . . . . . . . . . . . . . . 49<br />

4.3 Origins <str<strong>on</strong>g>of</str<strong>on</strong>g> the Wils<strong>on</strong> plot method . . . . . . . . . . . . . . . . . . . . . 50<br />

4.3.1 Wils<strong>on</strong> plot method (1915) . . . . . . . . . . . . . . . . . . . . . 50<br />

4.3.2 Modified Briggs <str<strong>on</strong>g>and</str<strong>on</strong>g> Young (1969) . . . . . . . . . . . . . . . . . 52<br />

4.3.3 Modificati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> Khartabil et al. (1988) . . . . . . . . . . . . . . . 53<br />

4.3.4 Rose direct method (2004) . . . . . . . . . . . . . . . . . . . . . . 54<br />

4.3.5 Styrylska method (2003) . . . . . . . . . . . . . . . . . . . . . . . 55<br />

4.4 LTCM implementati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the Wils<strong>on</strong> plot method . . . . . . . . . . . . 56<br />

4.4.1 Modified Briggs <str<strong>on</strong>g>and</str<strong>on</strong>g> Young method . . . . . . . . . . . . . . . . 57<br />

4.4.1.1 Tube-side formulati<strong>on</strong> . . . . . . . . . . . . . . . . . . . 58<br />

4.4.1.2 Shell-side formulati<strong>on</strong> . . . . . . . . . . . . . . . . . . . 58<br />

4.4.1.3 Uncertainty propagati<strong>on</strong> through the linear regressi<strong>on</strong> . 59<br />

4.4.2 Minimizati<strong>on</strong> algorithm . . . . . . . . . . . . . . . . . . . . . . . 59<br />

4.5 Results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61<br />

4.5.1 Experimental matrix . . . . . . . . . . . . . . . . . . . . . . . . . 62<br />

4.5.1.1 Modified Wils<strong>on</strong> plot results . . . . . . . . . . . . . . . 63<br />

4.5.1.2 Optimizati<strong>on</strong> algorithm results . . . . . . . . . . . . . . 65<br />

4.6 Measurement system validati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . 65<br />

4.6.1 Comparis<strong>on</strong> against the bundle boiling facility’s results . . . . . 65<br />

4.6.2 Water-to-water tests . . . . . . . . . . . . . . . . . . . . . . . . . 66<br />

4.6.2.1 Descripti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the water-to-water test facility . . . . . . 66<br />

4.7 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71<br />

5 Pool boiling <str<strong>on</strong>g>and</str<strong>on</strong>g> single-array experimental results 73<br />

5.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73<br />

5.2 Pool boiling <strong>on</strong> a single tube . . . . . . . . . . . . . . . . . . . . . . . . 73<br />

5.2.1 Pool boiling data reducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . 74<br />

5.2.2 Turbo-B5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76<br />

xi


CONTENTS<br />

5.2.3 Gewa-B5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84<br />

5.3 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film evaporati<strong>on</strong> <strong>on</strong> a single-array . . . . . . . . . . . . . . . . . 90<br />

5.3.1 Data reducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92<br />

5.3.2 Turbo-B5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93<br />

5.3.3 Gewa-B5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96<br />

5.4 C<strong>on</strong>clusi<strong>on</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100<br />

6 Bundle experimental results 101<br />

6.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101<br />

6.2 Experimental methodology . . . . . . . . . . . . . . . . . . . . . . . . . 101<br />

6.2.1 Variable states . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102<br />

6.3 Turbo-B5 results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103<br />

6.3.1 Fully active bundle heat transfer results . . . . . . . . . . . . . . 103<br />

6.3.2 Adiabatic side-array heat transfer results . . . . . . . . . . . . . 104<br />

6.3.3 Dry side-array bundle heat transfer results . . . . . . . . . . . . 105<br />

6.3.4 Utilized results <str<strong>on</strong>g>and</str<strong>on</strong>g> comparis<strong>on</strong> to the single-array data . . . . . 108<br />

6.4 Gewa-B5 results . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110<br />

6.4.1 Fully active bundle heat transfer results . . . . . . . . . . . . . . 110<br />

6.4.2 Adiabatic side-array heat transfer results . . . . . . . . . . . . . 112<br />

6.4.3 Dry side-array bundle heat transfer results . . . . . . . . . . . . 114<br />

6.4.4 Utilized results <str<strong>on</strong>g>and</str<strong>on</strong>g> comparis<strong>on</strong> to the single-array data . . . . . 115<br />

6.5 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117<br />

7 Flow visualizati<strong>on</strong> 119<br />

7.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119<br />

7.2 Single-array . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119<br />

7.2.1 Transiti<strong>on</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120<br />

7.2.2 Inter-column distance . . . . . . . . . . . . . . . . . . . . . . . . 123<br />

7.2.3 Diabatic flow visualizati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . 127<br />

7.3 Bundle high-speed videography . . . . . . . . . . . . . . . . . . . . . . . 129<br />

7.4 Probable causes for falling film enhancement <str<strong>on</strong>g>and</str<strong>on</strong>g> other phenomena seen 133<br />

7.5 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138<br />

xii


CONTENTS<br />

8 Predicti<strong>on</strong> methods 141<br />

8.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141<br />

8.2 Pool boiling predicti<strong>on</strong> method . . . . . . . . . . . . . . . . . . . . . . . 141<br />

8.3 Onset <str<strong>on</strong>g>of</str<strong>on</strong>g> dryout predicti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . 146<br />

8.4 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film evaporati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . 155<br />

8.4.1 Plateau heat transfer coefficient predicti<strong>on</strong> method . . . . . . . 156<br />

8.4.2 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film multiplier . . . . . . . . . . . . . . . . . . . . . . . . 159<br />

8.5 Accuracy <str<strong>on</strong>g>of</str<strong>on</strong>g> the predicti<strong>on</strong> methods . . . . . . . . . . . . . . . . . . . . 165<br />

8.6 Simulated refrigerant performance . . . . . . . . . . . . . . . . . . . . . 170<br />

8.7 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176<br />

9 C<strong>on</strong>clusi<strong>on</strong>s <str<strong>on</strong>g>and</str<strong>on</strong>g> recommendati<strong>on</strong>s 179<br />

9.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179<br />

9.2 C<strong>on</strong>solidati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the work performed . . . . . . . . . . . . . . . . . . . . 179<br />

9.2.1 Wils<strong>on</strong> plot method . . . . . . . . . . . . . . . . . . . . . . . . . 180<br />

9.2.2 Pool boiling results <str<strong>on</strong>g>and</str<strong>on</strong>g> new predictive method . . . . . . . . . . 181<br />

9.2.3 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film evaporati<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . 183<br />

9.2.3.1 Onset <str<strong>on</strong>g>of</str<strong>on</strong>g> dryout predicti<strong>on</strong> method . . . . . . . . . . . . 183<br />

9.2.3.2 Plateau heat transfer coefficient <str<strong>on</strong>g>and</str<strong>on</strong>g> Kff . . . . . . . . . 183<br />

9.2.4 <str<strong>on</strong>g>Visualizati<strong>on</strong></str<strong>on</strong>g> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185<br />

9.3 Aspects meriting further investigati<strong>on</strong> . . . . . . . . . . . . . . . . . . . 186<br />

9.4 Recommendati<strong>on</strong>s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187<br />

References 188<br />

A Experimental Uncertainty Analysis 201<br />

A.1 Introducti<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201<br />

A.2 Generalized uncertainty analysis methods . . . . . . . . . . . . . . . . . 201<br />

A.3 Uncertainty in temperature measurements . . . . . . . . . . . . . . . . 203<br />

A.4 Refrigerant mass flow rate uncertainty . . . . . . . . . . . . . . . . . . . 204<br />

A.5 Pressure measurement uncertainty . . . . . . . . . . . . . . . . . . . . . 205<br />

A.6 REFPROP uncertainty analysis . . . . . . . . . . . . . . . . . . . . . . . 205<br />

A.7 Temperature difference uncertainty . . . . . . . . . . . . . . . . . . . . . 206<br />

A.8 Uncertainty in the measurement <str<strong>on</strong>g>of</str<strong>on</strong>g> tube diameters . . . . . . . . . . . . 207<br />

xiii


CONTENTS<br />

A.9 Uncertainty in the measurement <str<strong>on</strong>g>of</str<strong>on</strong>g> heat transfer tube length . . . . . . 207<br />

A.10 Uncertainty in measurement <str<strong>on</strong>g>of</str<strong>on</strong>g> surface area . . . . . . . . . . . . . . . . 207<br />

A.11 Uncertainty in the value <str<strong>on</strong>g>of</str<strong>on</strong>g> thermal c<strong>on</strong>ductivity <str<strong>on</strong>g>of</str<strong>on</strong>g> the copper tubing . 208<br />

A.12 Uncertainty in the wall thermal resistance . . . . . . . . . . . . . . . . . 208<br />

A.13 Local heat flux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209<br />

A.14 Internal heat transfer coefficient . . . . . . . . . . . . . . . . . . . . . . . 211<br />

A.15 Overall heat transfer resistance . . . . . . . . . . . . . . . . . . . . . . . 213<br />

A.16 Local outside heat transfer coefficient . . . . . . . . . . . . . . . . . . . . 214<br />

A.17 <str<strong>on</strong>g>Falling</str<strong>on</strong>g> film multiplier . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215<br />

A.18 C<strong>on</strong>clusi<strong>on</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216<br />