Trace<br />

Configuration<br />

Table 2.3 Trace Collection Options with Description (continued)<br />

Option Sub-option Description<br />

The application<br />

configures the<br />

target and<br />

enables trace<br />

collection<br />

Stop trace collection<br />

when the core is<br />

suspended<br />

When trace<br />

collection stops,<br />

upload trace results<br />

If checked, stops trace collection<br />

automatically when the target is<br />

suspended. If you do not check this<br />

checkbox, you can stop trace collection<br />

either using the Stop Trace Collection<br />

button from the toolbar, or by using an<br />

Analysis Point.<br />

If you do not choose any of these options,<br />

the trace collection will stop after buffer is<br />

full or when application finishes<br />

execution.<br />

For details on Analysis points, refer to the<br />

Viewing Analysispoints topic. For details<br />

on the toolbar, refer to Figure 2.39 and<br />

Table 2.19.<br />

Automatically — Saves data<br />

to the Trace.dat file<br />

automatically after collection<br />

completes or is stopped.<br />

Manually from the toolbar —<br />

Lets you use the toolbar to<br />

save the trace data manually to<br />

the Trace.dat file.<br />

NOTE: For details on the toolbar, refer to<br />

Table 2.19.<br />

Lets you start collecting new trace data<br />

<strong>for</strong> the trace session using your<br />

application. In this case, all the above<br />

options are disabled.<br />

8. Per<strong>for</strong>m the following settings in the Trace Display group.<br />

a. Check the Display new trace data automatically checkbox to display the newly uploaded trace<br />

data automatically.<br />

b. In the Open trace at offset option, adjust the slider to select an approximate memory location <strong>for</strong><br />

opening the collected trace data. This setting is stored with the trace data, and thus will always<br />

control where the particular data is opened. The slider is approximate and provides selections<br />

from 0 to 100% in 10% increments. This option is normally set to 0%, but will be set to 100% if<br />

24 Tracing and Analysis Tools User Guide