MXV4 25-2<br />

60 Hz<br />

MXV4<br />

Characteristic curves n 1750 rpm Dimensions and weights<br />

80<br />

H m<br />

60<br />

40<br />

20<br />

30<br />

20<br />

10<br />

0<br />

1,5<br />

0.5<br />

0<br />

0<br />

0<br />

0<br />

50<br />

η %<br />

NPSH<br />

m<br />

1<br />

Pump type<br />

U.S. g.p.m.<br />

Imp. g.p.m. 2 3 4<br />

MXV4 25-204-60/C<br />

MXV4 25-205-60/C<br />

MXV4 25-206-60/C<br />

MXV4 25-207-60/C<br />

MXV4 25-208-60/C<br />

MXV4 25-210-60/C<br />

MXV4 25-212-60/C<br />

MXV4 25-214-60/C<br />

MXV4 25-216-60/C<br />

MXV4 25-218-60/C<br />

MXV4 25-220-60/C<br />

MXV4 25-220-60<br />

3<br />

m /h<br />

Q l/min<br />

Q m /h<br />

Motor<br />

power<br />

kW<br />

0,55<br />

0,55<br />

0,55<br />

0,55<br />

0,55<br />

0,55<br />

0,55<br />

0,75<br />

0,75<br />

0,75<br />

1,1<br />

3 4 5 6 7 8 9 10 11<br />

0 3<br />

72.1025.60<br />

0.5<br />

Performance<br />

18<br />

16<br />

14<br />

12<br />

10<br />

8<br />

7<br />

6<br />

5<br />

4<br />

0.5<br />

10<br />

HP<br />

0,75<br />

0,75<br />

0,75<br />

0,75<br />

0,75<br />

0,75<br />

0,75<br />

Motor<br />

size<br />

Head and power values valid for liquids with density<br />

3<br />

2<br />

ρ = 1.0 kg/dm and kinematic viscosity ν = max 20 mm /sec.<br />

Pst = Power with reference to one stage.<br />

1<br />

1<br />

1<br />

1,5<br />

η<br />

1<br />

1<br />

Pst<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M490V1<br />

20<br />

3<br />

m /h<br />

Q<br />

l/min<br />

H<br />

m<br />

5 6 7 8 9<br />

1.5<br />

1.5<br />

0<br />

0<br />

16<br />

20,5<br />

24,5<br />

28,5<br />

32,5<br />

40,5<br />

49<br />

57<br />

65<br />

73<br />

81<br />

0,6<br />

10<br />

15<br />

18,5<br />

22<br />

26<br />

29,5<br />

37<br />

44,5<br />

52<br />

59<br />

66,5<br />

74<br />

30<br />

Vertical Multi-Stage In-Line Pumps<br />

0,9<br />

15<br />

14<br />

17,5<br />

21<br />

24,5<br />

28<br />

35<br />

42<br />

49<br />

56<br />

63<br />

70<br />

2<br />

2<br />

1,2<br />

20<br />

13<br />

16<br />

19<br />

22,5<br />

25,5<br />

32<br />

38,5<br />

45<br />

51<br />

57,5<br />

64<br />

1,5<br />

25<br />

11,5<br />

14,5<br />

17,5<br />

20,5<br />

23<br />

29<br />

35<br />

40,5<br />

46,5<br />

52<br />

58<br />

0<br />

2.5<br />

40<br />

0.06<br />

2.5<br />

Test results with clean cold water, without gas content.<br />

A safety margin of + 0.5 m is recommended for the NPSH value.<br />

Tolerances in accordance with ISO 9906, Annex A.<br />

102<br />

1,8<br />

30<br />

10<br />

12,5<br />

15<br />

17,5<br />

20<br />

25<br />

30<br />

35<br />

40<br />

45<br />

50<br />

250<br />

200<br />

0.04<br />

4<br />

2<br />

ft<br />

150<br />

100<br />

50<br />

Pst<br />

kW<br />

0.02<br />

0.01<br />

ft<br />

2,1<br />

35<br />

9<br />

11<br />

13<br />

15,5<br />

17,5<br />

22<br />

26,5<br />

31<br />

35<br />

39,5<br />

44<br />

G 1<br />

20<br />

(1)<br />

2,4<br />

40<br />

7<br />

8,5<br />

10<br />

12<br />

13,5<br />

17<br />

20,5<br />

24<br />

27<br />

30,5<br />

34<br />

(2)<br />

FM<br />

215<br />

12,5<br />

100<br />

150<br />

Counterflanges<br />

in stainless steel<br />

DN 25<br />

43<br />

MXV4<br />

without<br />

motor<br />

G 1<br />

h2<br />

372<br />

396<br />

420<br />

444<br />

468<br />

516<br />

564<br />

612<br />

660<br />

708<br />

766<br />

75<br />

h2<br />

180 210<br />

M (4) h3<br />

255<br />

255<br />

255<br />

255<br />

255<br />

255<br />

255<br />

255<br />

255<br />

255<br />

295<br />

(3)<br />

h3<br />

DN 25<br />

Dimensions<br />

mm<br />

627<br />

651<br />

675<br />

699<br />

723<br />

771<br />

819<br />

867<br />

915<br />

963<br />

1061<br />

(1)<br />

FM<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

SM<br />

3.93.011 3.93.011/1<br />

without<br />

motor<br />

SM (4)<br />

with<br />

Pump weight<br />

motor<br />

kg (5) kg (6)<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

18<br />

19<br />

20<br />

21<br />

22<br />

23<br />

25<br />

26<br />

28<br />

30<br />

32<br />

MXV4<br />

with motor<br />

(1) Filling<br />

(2) Draining<br />

(3) Standard position of terminal box.<br />

(for other positions rotate motor through 90° or 180°)<br />

M<br />

DN 25<br />

MXV4 (G) (2)<br />

MXV4 (F)<br />

threaded<br />

250 flanged<br />

ports<br />

ports<br />

G 1<br />

115<br />

85<br />

65<br />

25<br />

(4) With standard motor<br />

(5) Weight MXV4 (G) = weight MXV4 (F) - 1kg<br />

(6) Net weight pump with standard motor<br />

Flanges EN 1092-2<br />

PN 25-40<br />

30,2<br />

31,2<br />

32,2<br />

33,2<br />

34,2<br />

35,2<br />

37,2<br />

41,2<br />

43,2<br />

45,2<br />

50,5<br />

75<br />

14