05.08.2013 Views

Download - Calpeda

Download - Calpeda

Download - Calpeda

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

MXV4 40-8<br />

60 Hz<br />

MXV4<br />

Characteristic curves n 1750 rpm Dimensions and weights<br />

H<br />

80<br />

m<br />

60<br />

40<br />

20<br />

40<br />

20<br />

3<br />

NPSH<br />

m<br />

2<br />

0<br />

0<br />

1<br />

0<br />

Pump type<br />

MXV4 40-804-60/C<br />

MXV4 40-805-60/C<br />

MXV4 40-806-60/C<br />

MXV4 40-807-60/C<br />

MXV4 40-808-60/C<br />

MXV4 40-810-60/C<br />

MXV4 40-811-60/C<br />

MXV4 40-813-60<br />

MXV4 40-815-60<br />

MXV4 40-817-60<br />

MXV4 40-819-60<br />

U.S. g.p.m.<br />

Imp. g.p.m.<br />

Motor<br />

power<br />

kW<br />

0,55<br />

0,55<br />

0,75<br />

0,75<br />

1,1<br />

1,1<br />

1,1<br />

1,5<br />

1,5<br />

2,2<br />

2,2<br />

10 15 20<br />

HP<br />

0,75<br />

0,75<br />

Motor<br />

size<br />

Head and power values valid for liquids with density<br />

3<br />

2<br />

ρ = 1.0 kg/dm and kinematic viscosity ν = max 20 mm /sec.<br />

Pst = Power with reference to one stage.<br />

1<br />

1<br />

1,5<br />

1,5<br />

1,5<br />

2<br />

2<br />

3<br />

3<br />

10<br />

M480V1<br />

M480V1<br />

M480V1<br />

M480V1<br />

M490V1<br />

M490V1<br />

M490V1<br />

90 L4<br />

90 L4<br />

100 L4<br />

100 L4<br />

15<br />

0<br />

0<br />

0<br />

3 m /h<br />

Q l/min 40 60<br />

0<br />

432<br />

65<br />

7 8<br />

80 100 120 140<br />

60<br />

0.12<br />

Pst<br />

η % η<br />

kW<br />

0.08<br />

Q<br />

3<br />

m /h<br />

Performance<br />

MXV4 40-819-60<br />

17<br />

15<br />

13<br />

11<br />

10<br />

8<br />

7<br />

6<br />

5<br />

4<br />

Pst<br />

3<br />

m /h<br />

Q<br />

l/min<br />

H<br />

m<br />

0<br />

0<br />

17<br />

21,5<br />

26<br />

30<br />

34,5<br />

43<br />

47<br />

56<br />

64,5<br />

73<br />

82<br />

20<br />

25<br />

2,3<br />

38,3<br />

16<br />

20<br />

24<br />

28<br />

32<br />

40<br />

44<br />

52<br />

60<br />

68<br />

76<br />

3<br />

50<br />

15,5<br />

19<br />

23<br />

27<br />

31<br />

38,5<br />

42,5<br />

50<br />

58<br />

65,5<br />

73<br />

3,6<br />

60<br />

15<br />

18,5<br />

22<br />

26<br />

29,5<br />

37<br />

41<br />

48<br />

55,5<br />

63<br />

70,5<br />

35<br />

72.993.60<br />

432<br />

5 6 7 8<br />

Vertical Multi-Stage In-Line Pumps<br />

30<br />

25<br />

4,2<br />

70<br />

14<br />

18<br />

21,5<br />

25<br />

28,5<br />

35,5<br />

39<br />

46<br />

53<br />

60,5<br />

67,5<br />

30<br />

4,8<br />

80<br />

13,5<br />

17<br />

20<br />

23,5<br />

27<br />

33,5<br />

37<br />

43,5<br />

50<br />

57<br />

63,5<br />

Test results with clean cold water, without gas content.<br />

A safety margin of + 0.5 m is recommended for the NPSH value.<br />

Tolerances in accordance with ISO 9906, Annex A.<br />

104<br />

250<br />

200<br />

150<br />

100<br />

50<br />

0.06<br />

0.04<br />

0.02<br />

ft<br />

8<br />

4<br />

ft<br />

5,4<br />

90<br />

12,5<br />

16<br />

19<br />

22<br />

25<br />

31,5<br />

34,5<br />

41<br />

47<br />

53,5<br />

60<br />

G 1 1/2<br />

20<br />

(1)<br />

6<br />

100<br />

11,5<br />

14,5<br />

17,5<br />

20,5<br />

23<br />

29<br />

32<br />

37,5<br />

43,5<br />

49<br />

55<br />

(2)<br />

6,9<br />

115<br />

10<br />

12,5<br />

15<br />

17,5<br />

20<br />

25<br />

27,5<br />

32,5<br />

37,5<br />

42,5<br />

47,5<br />

FM<br />

225<br />

14<br />

130<br />

190<br />

Counterflanges<br />

in stainless steel<br />

DN 40<br />

43<br />

8,1<br />

135<br />

6,5<br />

8<br />

10<br />

11,5<br />

13<br />

16,5<br />

18<br />

21,5<br />

24,5<br />

28<br />

31,5<br />

MXV4<br />

without<br />

motor<br />

G 1 1/2<br />

h2<br />

401<br />

431<br />

461<br />

491<br />

531<br />

591<br />

621<br />

681<br />

741<br />

811<br />

871<br />

80<br />

h2<br />

215 246<br />

M (4) h3<br />

255<br />

255<br />

255<br />

255<br />

295<br />

295<br />

295<br />

282<br />

282<br />

313<br />

313<br />

h3<br />

DN 40<br />

(3)<br />

Dimensions<br />

mm<br />

656<br />

686<br />

716<br />

746<br />

826<br />

886<br />

916<br />

963<br />

1023<br />

1124<br />

1184<br />

(1)<br />

FM<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

200<br />

250<br />

250<br />

SM<br />

3.93.011 3.93.011/1<br />

without<br />

motor<br />

SM (4)<br />

with<br />

Pump weight<br />

motor<br />

kg (5) kg (6)<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

127,5<br />

128<br />

128<br />

135<br />

135<br />

21<br />

22<br />

23<br />

25<br />

27<br />

29<br />

30<br />

31<br />

33<br />

36<br />

39<br />

MXV4<br />

with motor<br />

(1) Filling<br />

(2) Draining<br />

(3) Standard position of terminal box.<br />

(for other positions rotate motor through 90° or 180°)<br />

M<br />

DN 40<br />

MXV4 (G) (2)<br />

MXV4 (F)<br />

threaded<br />

280 flanged<br />

ports<br />

ports<br />

G 1 1/2<br />

150<br />

110<br />

84<br />

40<br />

(4) With standard motor<br />

(5) Weight MXV4 (G) = weight MXV4 (F) - 1kg<br />

(6) Net weight pump with standard motor<br />

Flanges EN 1092-2<br />

PN 25-40<br />

33,2<br />

34,2<br />

38,2<br />

40,2<br />

45,5<br />

47,5<br />

48,5<br />

46<br />

48<br />

60<br />

63<br />

80<br />

19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!