Change of Ownership Applicant Guide - Bright from the Start
Change of Ownership Applicant Guide - Bright from the Start
Change of Ownership Applicant Guide - Bright from the Start
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
WINDOWS<br />
WINDOW SPACE REQUIREMENTS FOR CENTERS WITHOUT CENTRAL HEAT & AIR<br />
(NOTE: THIS ONLY APPLIES IF YOU DO NOT HAVE A CENTRAL UNIT OR AIR CONDITIONER<br />
UNITS.)<br />
The window space in each child care room is determined in <strong>the</strong> following way:<br />
• When central heat and air is not provided total window space per<br />
room must be 5% <strong>of</strong> <strong>the</strong> useable floor space.<br />
• Multiply useable floor space by .05 to determine required window<br />
space.<br />
• 50% <strong>of</strong> required window space must be screened and operable.<br />
• To determine amount <strong>of</strong> space <strong>of</strong> <strong>the</strong> window multiply <strong>the</strong> length<br />
times (X) <strong>the</strong> width <strong>of</strong> <strong>the</strong> window to obtain <strong>the</strong> total square footage.<br />
WINDOW SPACE REQUIREMENTS FOR CENTERS HAVING NO VENT FANS OVER THE<br />
DIAPERING SURFACES<br />
• If no exhaust/ventilation fan is over <strong>the</strong> diapering area, operable<br />
window space must equal 2.5% <strong>of</strong> <strong>the</strong> useable floor space.<br />
Example: A room in <strong>the</strong> center has 1,259 square feet <strong>of</strong> usable floor space and will house<br />
diapered children.<br />
1,259 X 2.5%=31 square feet <strong>of</strong> screened and operable window space needed.<br />
To measure screened and operable window space:<br />
Open <strong>the</strong> window to <strong>the</strong> maximum opening position.<br />
Measure <strong>the</strong> screened open area.<br />
(Ex. 2’2” X 2’0”=4.3(round down) = 4 square feet <strong>of</strong> screened and operable space<br />
for this window.<br />
If this room needs 31 square feet <strong>of</strong> screened and operable space, <strong>the</strong>n you would<br />
need 8 windows screened and operable.<br />
Note: Screens should fit tightly to prevent insects.