34169522 - heidenhain - DR. JOHANNES HEIDENHAIN GmbH
34169522 - heidenhain - DR. JOHANNES HEIDENHAIN GmbH
34169522 - heidenhain - DR. JOHANNES HEIDENHAIN GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Error Messages<br />
Message Cause and effect<br />
SIGNAL X Encoder signal is too small,<br />
e.g. when an encoder is<br />
contaminated.<br />
PROB. ERROR Before touching off on the<br />
workpiece, the tool must move<br />
by a distance of at least 0.2 mm.<br />
ERR. REF. X The spacing of the reference<br />
marks as defined in P43 is not<br />
the same as the actual spacing.<br />
FRQ. ERR. X The input frequency for this<br />
encoder input is too high. This<br />
can occur when the scale is<br />
moved too fast.<br />
ERR. MEMORY Check sum error: Check the<br />
datum, operating parameters and<br />
compensation values for multipoint<br />
axis error compensation.<br />
If the error recurs, contact your<br />
service agency!<br />
To erase error messages:<br />
After you have removed the cause of error:<br />
➤ Press the CL key.<br />
Error Messages<br />
29