Soil Vapor Extraction (SVE) and Air Sparging at Three Drycleaner<br />

Sites, Various Locations (continued)<br />

Costs:<br />

A design and implementation cost <strong>of</strong> $251,552 was provided for Hooker’s Cleaners. Cost information was not provided<br />

for the other two sites.<br />

Description:<br />

SVE and air sparging were conducted at three drycleaner sites in Michigan contaminated with chlorinated organic<br />

compounds from leaks, spills, or dumping <strong>of</strong> drycleaning solvents or wastewaters. Cleanup goals for groundwater were<br />

based on state regulatory cleanup level, and ranged from 5.0 µg/L to 34 µg/L for PCE. The cleanup goal for TCE was<br />

5.0 µg/L. Although all <strong>of</strong> the treatment systems removed contaminants from the subsurface, only one treatment reported to<br />

have achieved treatment goals for groundwater in a portion <strong>of</strong> the site.<br />