• nanoe-G check mode<br />

o To enable nanoe-G check mode, during nanoe-G operation ON:<br />

SET<br />

Remote control normal mode<br />

Press continuously for 15s<br />

SET<br />

SET<br />

SET<br />

Transmit ECO demo code<br />

and after 2 seconds return to normal<br />

mode.<br />

Transmit check code<br />

and after 2 seconds return to normal<br />

mode.<br />

Transmit sunlight sensor check code<br />

and after 2 seconds return to normal<br />

mode.<br />

o If there is abnormal discharge, nanoe-G indicator blinks immediately.<br />

• Error detection control<br />

When nanoe-G indicator blinks, it indicates error listed below:<br />

o Nanoe-G connector at main PCB open<br />

Judgment method<br />

• During nanoe-G operation, nanoe-G connector at main PCB is opened.<br />

Troubleshooting method<br />

• Connect the connector or stop operation to cancel the blinking.<br />

o Abnormal discharge error<br />

Judgment method<br />

• During nanoe-G operation, the nanoe-G system has abnormal discharge due to short-circuit caused<br />

by water or dust adhesion and so forth, with Lo-feedback voltage (at microcontroller).<br />

• When abnormal discharge occurred, every 30 minutes the unit supplies power to the nanoe-G<br />

system.<br />

• When abnormal discharge occurs for 24 times continuously, nanoe-G indicator blinks.<br />

Troubleshooting method<br />

• Press nanoe-G button or OFF/ON button to stop the operation and check the nanoe-G connector at<br />

PCB.<br />

• After that, press nanoe-G button again to confirm the nanoe-G indicator do not blinks.<br />

• The 24 timer counter will be clear after 10 minutes of normal operation or when operation stops.<br />

Error reset method<br />

• Press “OFF/ON” button to OFF the operation.<br />

• Press AUTO OFF/ON button at indoor unit to OFF the operation.<br />

• OFF Timer activates.<br />

• Power supply reset.<br />