14.08.2013 Views

Indoor Unit Outdoor Unit CS-HE9NKE CS-HE12NKE CS ... - LMG

Indoor Unit Outdoor Unit CS-HE9NKE CS-HE12NKE CS ... - LMG

Indoor Unit Outdoor Unit CS-HE9NKE CS-HE12NKE CS ... - LMG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

15.4.12 H30 (Compressor Discharge Temperature Sensor Abnormality)<br />

Malfunction Decision Conditions<br />

• During startup and operation of cooling and heating, the temperatures detected by the outdoor discharge pipe<br />

temperature sensor are used to determine sensor errors.<br />

Malfunction Caused<br />

• Faulty connector connection.<br />

• Faulty sensor.<br />

• Faulty PCB.<br />

Troubleshooting<br />

71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!