13.3.3 Overload Protection Control<br />

• The compressor operating frequency is regulated in accordance to indoor heat exchanger temperature as shown<br />

below.<br />

• If the heat exchanger temperature exceeds 60°C, compressor will stop.<br />

60°C<br />

52°C<br />

49°C<br />

<strong>Indoor</strong> Heat<br />

Exchanger Temp.<br />

13.3.4 Compressor Oil Return Control<br />

Free<br />

OFF<br />

Frequency Reduce<br />

Frequency Limited<br />

• When compressor starts, the compressor will be regulated for 240 seconds.<br />

13.3.5 Cold Draught Prevention Control<br />

• When indoor pipe temperature is low, cold draught operation starts where indoor fan speed will be reduced.<br />

13.3.6 Deice Operation<br />

• When outdoor pipe temperature and outdoor air temperature is low, deice operation start where indoor fan motor<br />

and outdoor fan motor stop and the operation LED deice indicator ON during this operation.<br />