12.12.1.3 Judge Ambient Condition<br />

• According to sunlight intensity over a period of time, the system will analyze the ambient condition is sunny,<br />

cloudy or night.<br />

12.12.1.4 Temperature Shift<br />

Ambient condition<br />

COOL/DRY Mode<br />

Set Temperature<br />

Cloudy/<br />

Night<br />

Sunny<br />

Cloudy/<br />

Night<br />

+1°C<br />

Sunny<br />

HEAT Mode<br />

Set Temperature -1°C -1°C<br />

ECONAVI is activated while it is cloudy / night<br />

ECONAVI is activated while it is sunny<br />

12.12.1.5 Sunlight Sensor Check Mode<br />

• To enable sunlight sensor check mode, during unit is OFF (power standby):<br />

SET<br />

Remote control normal mode<br />

Press continuously for 15s<br />

SET<br />

SET<br />

SET<br />

Transmit ECO demo code<br />

and after 2 seconds return to normal<br />

mode.<br />

Transmit check code<br />

and after 2 seconds return to normal<br />

mode.<br />

Transmit sunlight sensor check code<br />

and after 2 seconds return to normal<br />

mode.<br />

• Operation details<br />

o The sunlight sensor check mode will be operated for 5 minutes.<br />

o During check mode, the ON and OFF timer will be memorized but it operation be ignored.<br />

o During check mode, if the sunlight sensor check code is retransmitted, the 5 minutes counter will be reset.<br />

o During check mode, if sunlight sensor detected the sunlight intensity value above minimum level, the<br />

ECONAVI indicator turns ON. Else if sunlight sensor detected sunlight intensity value below minimum level,<br />

the ECONAVI indicator is OFF.<br />

• To disable sunlight sensor check mode<br />

o After check mode is ended (5 minutes counter elapsed), press AUTO OFF/ON button at indoor unit.<br />

o If the sunlight sensor detected sunlight intensity is at abnormal range, the check mode will be ended.<br />