Oil pumps<br />
Oil pumps – Delta<br />
Type Code no.<br />
Delta Relevant <strong>Danfoss</strong> types<br />
1-2<br />
pipe<br />
Type Code no. Comments/accessories<br />
VM VM3LR 14 (or F84-220 1 ➨ BFP 21 L5 071N01722) VM<br />
VM<br />
VM3LR 14<br />
VM3LR 24<br />
(or F84-220<br />
(or F84-220<br />
1<br />
2<br />
➨<br />
➨<br />
BFP 21 L5<br />
BFP 21 L5<br />
071N0172<br />
071N0172<br />
Delta: 80 l/h;<br />
BFP: 40 l/h at 10 bar<br />
2)<br />
VM VM3RL 14 (or F84-220 1 ➨ BFP 21 R5 071N0173<br />
VM VM3RL 24 (or F84-220 2 ➨ BFP 21 R5 071N0173<br />
VM VM1LR 24 (or M8-220 2 ➨ BFP 21 L3 071N0170<br />
VM VM1LR 14 (or M8-220 1 ➨ BFP 21 L3 071N01702) VM VM1LL 24 (or M8-220 2 ➨ BFP 21 L3 071N0170<br />
VM VM1LL 14 (or M8-220 1 ➨ BFP 21 L3 071N01702) VM VM1RL 24 (or M8-220 2 ➨ BFP 21 R3 071N0171<br />
VM VM1RL 14 (or M8-220 1 ➨ BFP 21 R3 071N01712) VM VD1RR 24 (or M8-220 2 ➨ BFP 21 R3 071N0171<br />
VM VM1RR 14 (or M8-220 1 ➨ BFP 21 R3 071N01712) VM VM2LR 24 (or M8-220 2 ➨ BFP 21 L5 071N0172*<br />
VM VM2LR 14 (or M8-220 1 ➨ BFP 21 L5 071N0172*2 )<br />
VM VM2LL 24 (or M8-220 2 ➨ BFP 21 L5 071N0172*<br />
VM VM2LL 14 (or M8-220 1 ➨ BFP 21 L5 071N0172*2 )<br />
VM VM2RL 24 (or M8-220 2 ➨ BFP 21 R5 071N0173*<br />
VM VM2RL 14 (or M8-220 1 ➨ BFP 21 R5 071N01732) VM VM2RR 24 (or M8-220 2 ➨ BFP 21 R5 071N0173*<br />
VM VM2RR 14 (or M8-220 1 ➨ BFP 21 R5 071N01732) VM VM3LR 14 (or M8-220 1 ➨ BFP 21 L5 071N01722) VM VM3LR 24 (or M8-220 2 ➨ BFP 21 L5 071N0172 Delta: 80 l/h;<br />
VM VM3RL 14 (or M8-220 1 ➨ BFP 21 R5 071N0173 BFP: 40 l/h at 10 bar<br />
2)<br />
VM VM3RL 24 (or M8-220 2 ➨ BFP 21 R5 071N0173<br />
*) Delta: 57 l/h; BFP: 40 l/h at 10 bar<br />
2) This pump is delivered for 2-pipe operation. A changeover to 1-pipe operation is possible, see Changeover 1 - 2 pipe.<br />
F84-220:<br />
See previous page<br />
M8-220: Indicates coil with fixed cable<br />
<strong>and</strong> for 220 V, 50 Hz.<br />
Generally the following cable should be<br />
ordered here:<br />
Cable no. 071G0200 L = 500 mm, or<br />
Cable no. 071G0204 L = 710 mm<br />
Cable no. 071G0202 L = 280 mm<br />
If using other voltages the following<br />
must be<br />
ordered extra (only for BFP21):<br />
Coil no. 071N0061 for 110/120 V a.c. or<br />
Coil no. 071N0062 for 24 V a.c.<br />
M8-220: See previous page<br />
38