Hindustan Petroleum Corporation Limited
Hindustan Petroleum Corporation Limited
Hindustan Petroleum Corporation Limited
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
HINDUSTAN PETROLEUM CORPORATION LIMITED<br />
LPG PROJECTS, HINDUSTAN BHAVAN-3, 8 S.V. MARG, BALLARD ESTATE,<br />
MUMBAI-400001<br />
20. ACTUATOR DETAILS (AUDCO / IMPORTED)<br />
MANUFACTURER VTS<br />
(APPROVED: AUDCO, BETTIS, KTM, ROTARK, BIFFI, EL-O-MATIC, HYTORQ, NELES-<br />
JAMESBERY,TYCO-KEYSTONE)<br />
MODEL VTS<br />
ACTION ON AIR FAILURE CLOSE<br />
OPERATOR TYPE PISTON<br />
SIZE VTS<br />
SPRING RETURN TO CLOSE<br />
TORQUE REQUIRED (MINIMUM TORQUE) 130% OF THE VALVE<br />
PREDICTED SOUND LEVEL 80 dB<br />
MIN. AIR PRESSURE REQD.(NOT MORE THAN VTS<br />
4 KG/SQ.CM)<br />
LIMIT SWITCH D P D T<br />
LIMIT SWITCH BOX EX.PROOF (IMPORTED)<br />
LIMIT SWITCH MAKE VTS<br />
INDICATION OPEN/CLOSE<br />
CONTACT RATING VTS<br />
MANUAL OVERRIDE REQUIRED<br />
QUICK CLOSING IN MANUAL MODE REQUIRED<br />
FILTER & REGULATOR GAUGE REQUIRED WITH OUTPUT<br />
PORTS 2<br />
FLP SOLENOID VALVE 3 WAY BRASS<br />
MAKER'S SERIES NUMBER VTS<br />
1. EQUIPMENT SHALL COMPLY WITH THIS DATA SHEET. DEVIATIONS (TO BE<br />
STATED AS SUCH) AND REMAINING INFORMATION SHALL BE CLEARLY<br />
SPECIFIED BY VENDOR.<br />
2. ALL THE TORQUE VALUES OF THE ACTUATOR (AIR BREAK, AIR END,<br />
SPRING BREAK AND SPRING END) SHALL BE HIGHER THAN THE 130%<br />
TORQUE REQUIREMENTS OF THE VALVE (VALVE BREAK TORQUE).