8. Faults<br />
8.1 Forward speed too low<br />
8.2 Reverse speed too low<br />
8.3 No reverse motion<br />
8.4 Loss of hydraulic oil<br />
T01008GB.fm 43<br />
Cause Remedy<br />
To little hydraulic oil in the centre pole<br />
head.<br />
Top up hydraulic oil.<br />
Air in hydraulic control. Bleed system.<br />
Cause Remedy<br />
Too much hydraulic oil in centre pole<br />
head.<br />
Cause Remedy<br />
Faults<br />
Correct oil level in accordance with<br />
mark.<br />
Mechanical fault. Contact <strong>Wacker</strong> service dept.<br />
Cause Remedy<br />
Leaks, hydraulic hose defective. Contact <strong>Wacker</strong> service dept.