Appendix<br />

°F<br />

GPM<br />

140<br />

130<br />

120<br />

110<br />

100<br />

90<br />

80<br />

70<br />

60<br />

134.2°F<br />

Figure 11: First Hour Rating Test – Rheem HP50 Normal Mode<br />

50<br />

0.0<br />

0 15 30 45 60 75 90 105 120 135 150<br />

5<br />

4<br />

3<br />

2<br />

1<br />

35.5 Gallons<br />

25°F<br />

25.1 Gallons<br />

First Hour Rating:<br />

60.6 Gallons<br />

Minutes<br />

491-09.17.doc A-6<br />

Six Tank Thermocouples (°F)<br />

Average Tank Temperature (°F)<br />

Water Inlet Temperature (°F)<br />

Water Outlet Temperature (°F)<br />

Water Flow Rate (GPM)<br />

Power (kW)<br />

Figure 12: DOE Standard Energy Factor Draw Profile<br />

DOE Draw Profile<br />

64.3 Gallons<br />

in 6 Draws<br />

GPM<br />

Gallons<br />

December 23, 2009<br />

0<br />

0<br />

12:00 AM 6:00 AM 12:00 PM 6:00 PM 12:00 AM<br />

8<br />

4<br />

4.5<br />

4.0<br />

3.5<br />

3.0<br />

2.5<br />

2.0<br />

1.5<br />

1.0<br />

0.5<br />

20<br />

16<br />

12<br />

GPM / kW<br />

Gallons / Draw