3.2 Mode of operation<br />

3 Functional description – Mode of operation<br />

<strong>HDG</strong> <strong>Navora</strong> 20/25/30 with <strong>HDG</strong> Lambda Control 1 boiler<br />

1<br />

Figure 3/3 - Boiler <strong>HDG</strong> <strong>Navora</strong> 20/25/30 with <strong>HDG</strong> Lambda Control 1<br />

Inside the <strong>HDG</strong> <strong>Navora</strong> 20/25/30 with <strong>HDG</strong> Lambda Control 1 boiler,<br />

fuel which has been manually placed in the fuelling chamber (2) and<br />

ignited is degassed through the addition of primary air.<br />

The resulting wood gas is mixed with secondary air in the<br />

combustion chamber (3) where it is burnt.<br />

Ashes are collected in the large ash compartments (5) for<br />

combustion ash and fly ash.<br />

The air necessary for combustion is supplied as required via the<br />

suction fan (1) and two servo drives with metering mechanisms (4).<br />

Via the oxygen sensor (7), the boiler temperature sensor (not visible<br />

in Figure 3/3 - Boiler <strong>HDG</strong> <strong>Navora</strong> 20/25/30 with <strong>HDG</strong> Lambda<br />

Control 1) and the flue gas temperature sensor (6):<br />

• the firing is permanently monitored,<br />

• the boiler output is adjusted,<br />

• emissions are minimised and<br />

• boiler efficiency is optimised.<br />

© <strong>HDG</strong> Bavaria GmbH 06/2008 <strong>HDG</strong> <strong>Navora</strong> 20/25/30 with <strong>HDG</strong> Lambda Control 1 - V 2 - en<br />