CENTER SAFETY EXIT<br />

W4<br />

G B A<br />

MS LINK<br />

CENTER SAFETY EXIT<br />

GG BB AA<br />

M/S M/S Link Link<br />

OMRON<br />

Retro-Reflective<br />

Photocell<br />

<strong>Elite</strong> Part #<br />

A OMRON<br />

UL Approved<br />

Conduit<br />

Mounted<br />

Reflector<br />

®<br />

SYSTEM ON<br />

SENSORS<br />

ALARM<br />

SENSOR<br />

1 3<br />

COMMAND<br />

PROCESSED<br />

OmniControl Surge Suppressor<br />

Center Center Safety Safety Exit Exit Fire Fire Dept Dept Strike Strike Open Open Radio Radio<br />

Loop Loop Loop Loop Loop Loop Key Key Switch Switch Push Push Button Button Receiver Receiver<br />

SAFETY PRECAUTIONS<br />

SECONDARY ENTRAPMENT WIRING<br />

P/N P/N Q410 Q410<br />

Patent Patent Pending Pending<br />

–– ++<br />

Class Class 22<br />

Supply Supply<br />

24 24 Volts Volts DC DC<br />

Surge Terminal Wiring for Electronic Box<br />

1 3<br />

FIRE<br />

DEPT.<br />

EXIT<br />

LOOP<br />

REVERSE<br />

SENSOR<br />

STRIKE<br />

OPEN<br />

SAFETY<br />

LOOP<br />

TIMER<br />

OFF<br />

OPEN LEFT<br />

RADIO<br />

RECEIVER<br />

CENTER<br />

LOOP<br />

60<br />

SECONDARY ENTRAPMENT PROTECTION<br />

Photocell Sensor<br />

Sensing Edges<br />

Danger<br />

3<br />

1 3<br />

ON<br />

OPEN RIGHT<br />

GATE<br />

LOCKED<br />

RESET<br />

MOTOR<br />

DC-BACKUP<br />

POWER<br />

OVERLOAD<br />

OPEN<br />

STOP<br />

CLOSE<br />

ALARM<br />

SENSOR<br />

Align with<br />

Reflector<br />

MADE IN USA<br />

Reflector<br />

Wiring for<br />

OmniControl<br />

Board<br />

Mount to Wall or Floor<br />

4 Wires go to Gate Operator<br />

Omni Control Board and<br />

Electronic Box Terminals<br />

P<br />

SENSOR ALARM<br />

Radio Receiver +<br />

Radio Receiver -<br />

Gate Open<br />

OMRON Retro-Reflective Photocell Wiring<br />

Danger<br />

Sensor<br />

Edges<br />

1 2 3 4 5 6 42 to 240VAC<br />

(C1) (NO1) (NC1) (NC2) (NO2) (C1) 24 to 240VDC<br />

Wall<br />

LIGHT ON DARK ON<br />

Top of Gate<br />

Photocell<br />

Sensor Head<br />

Important:<br />

This switch must<br />

be in the “Light<br />

On” position for<br />

the system to<br />

function properly<br />

ELITE Part #<br />

A OMRON<br />

If multiple sensors are being used, all of the photo<br />

beam sensors are to be connected in parallel at the<br />

sensor input on the Omni Control board.<br />

If you are going to use a non-contact sensor as a secondary entrapment protection you<br />

should use a recognized component to comply with the revised UL 325 intended to be used<br />

in class I or class II gate operator, like the following: OMRON Retro-Reflective Photocell,<br />

Model: E3K-R10K4-NR<br />

Wall