INSTALLATION INSTRUCTIONS<br />
Accessories<br />
Note: Except the above parts provided, the other parts needed during<br />
installation you must purchase.<br />
<strong>12</strong>cm above<br />
Number<br />
A<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
30cm above<br />
B<br />
Fig.3<br />
Seal (See Page 8 for details)<br />
Drain Joint(See<br />
page 8 for details)<br />
3<br />
Air Filter<br />
Air Outlet<br />
200cm above<br />
Name of Accessories<br />
Installation Plate<br />
Clip Anchor<br />
Self-tapping Screw A ST3.9X25<br />
Connecting<br />
pipe Assembly<br />
Remote controller<br />
2<br />
15cm above<br />
2.3m above<br />
60cm above<br />
1<br />
Liquid side<br />
Gas side<br />
8 Self-tapping Screw B ST2.9X10<br />
9 Remote controller holder<br />
<strong>12</strong>cm above<br />
60cm above<br />
6<br />
30cm above<br />
C<br />
6.35<br />
9.52<br />
<strong>12</strong>.7<br />
Loop the<br />
connective<br />
cable.<br />
¡This illustration is for explanation purposes only.<br />
¡ Copper lines must be insulated independently .<br />
4<br />
(£<strong>12</strong>000Btu/h model)<br />
(¡<strong>12</strong>000Btu/h model)<br />
1<br />
8<br />
8<br />
1<br />
CAUTION<br />
Ensure that the space around the left and<br />
right of the indoor unit is more than <strong>12</strong>cm.<br />
The indoor unit should be installed allowing<br />
a minimum clearance of 15cm from the<br />
ceiling.<br />
Use a stud finder to locate studs to prevent<br />
unnecessary damage to the wall.<br />
A minimum pipe run of 3 metres is required<br />
to minimise vibration & excessive noise.<br />
The indoor unit should be installed on the<br />
wall at a height of 2.3 metres or more from<br />
the floor .<br />
Two of the A, B and C directions should be<br />
free from obstructions.<br />
Remote Controller<br />
7<br />
(C)<br />
。<br />
SET TEMPERATURE<br />
AUTO<br />
FAN<br />
COOL<br />
HIGH<br />
DRY<br />
MED<br />
HEAT<br />
LOW<br />
TEMP<br />
MODE ON/OFF FAN SPEED<br />
SWING SLEEP TIMER ON<br />
TIMER OFF<br />
RESET LOCK<br />
AIR<br />
LED<br />
DIRECTION<br />
DISPLAY TURBO<br />
8<br />
Q¡ ty<br />
1<br />
Parts you must<br />
purchase (A minimum<br />
pipe wall-thickness<br />
of 0.7mm is required.)<br />
1<br />
2<br />
1<br />
Self-tapping screw B<br />
ST2.9x10-C-H<br />
Remote controller<br />
holder<br />
9