years, however, more and more utilities started to question this<br />
practice as the loads in current systems have become very<br />
sensitive to momentary interruptions. Auto-reclosing can create<br />
momentary interruptions to a large number of customers,<br />
yielding bad power quality consequences. As a result, some<br />
utilities are trying to eliminate the auto-reclosing practice.<br />
However, eliminating the practice implies a fundamental<br />
change in planning and operating a power distribution system.<br />
It seems that one cannot achieve simultaneous improvement on<br />
both power reliability and power quality using auto-reclosing.<br />
In view of the far-reaching impact of this issue, this work<br />
conducts a survey as a starting point to prepare industry to deal<br />
with the issue in a proactive and strategic manner.<br />
Keywords: Power quality, reliability, distribution<br />
systems, reclosers, overcurrent protection.<br />
Análise da necessidade de alteração dos ajustes<br />
dos relés de sobrecorrente de instalações<br />
industriais com geradores síncronos após a<br />
ocorrência de ilhamento<br />
F. Trindade, Madson Cortes De Almeida, Walmir De Freitas<br />
Filho<br />
In: XVIII Congresso Brasileiro de Automática (CBA 2010)-<br />
Antonio Padilha Feltrin(Ed.) - ISBN: 978-85-61507-02-2<br />
SBA - Sociedade Brasileira de Automática – Bonito(MS) -<br />
Brasil Sep-2010 pp:2441-2446<br />
Abstract: With the advance of digital relays, adaptive<br />
protection schemes have become reality. This type of protection<br />
schemes can be useful in industrial systems with synchronous<br />
generators that operate in both modes: parallel and isolated<br />
(islanded). In this context, it is important to select the relays<br />
that must have their settings automatically changed based on<br />
the system operation condition. This work presents a simple<br />
classification approach to select the relays to be used in the<br />
adaptive scheme. Indeed, the approach selects the branches<br />
protected by overcurrent protection whose relays must be<br />
adaptively set. This classification is based on short-circuit<br />
studies. This scheme improves the selectivity and coordination<br />
of overcurrent protection schemes since it is not necessary to<br />
find a solution to meet both parallel and islanded operation. The<br />
proposed approach is successful applied to a real Brazilian<br />
industrial plant with three cogeneration units.<br />
Keywords: Distributed Generation, Industrial Plants,<br />
Adaptive Protection Scheme, Synchronous Generator.<br />
Análise de redes de distribuição trifásicas com<br />
incertezas representadas por conjuntos<br />
nebulosos<br />
Patrícia L. Cavalcante, Carlos Alberto Favarin Murari, Silvio<br />
S. Segura<br />
In: XVIII Congresso Brasileiro de Automática (CBA 2010)-<br />
Antonio Padilha Feltrin(Ed.) - ISBN: 978-85-61507-02-2<br />
SBA - Sociedade Brasileira de Automática – Bonito(MS) -<br />
Brasil Set-2010 pp:2016-2023<br />
Abstract: The research and development of electric and<br />
mathematical models for the components of the electric<br />
networks and for the loads contribute for the computer<br />
simulation of the electric power systems that it happens in the<br />
smallest time and results in compatible values with the reality.<br />
This is the subject of this research that we describe in this<br />
article, where the main objective was the development of a<br />
three-phase load flow for the analysis of electric power<br />
distribution networks with some variables that are not<br />
deterministic, particularly the loads. In this sense, the imprecise<br />
variables were represented as fuzzy numbers (in the bell form)<br />
and it is presented a Specialized Three-Phase Load Flow that<br />
incorporates fuzzy sets and respective mathematical operations.<br />
The obtained results confirm the good performance of this new<br />
method.<br />
Keywords: Three-phase power flow, uncertainties, fuzzy<br />
numbers<br />
Aplicação do controlador ipfc para o<br />
amortecimento de oscilações eletromecânicas<br />
em sistemas de potência<br />
Danilo B. do Valle, Igor Kopcak, Vivaldo F. da Costa<br />
In: XVIII Congresso Brasileiro de Automática (CBA 2010)-<br />
Antonio Padilha Feltrin(Ed.) - ISBN: 978-85-61507-02-2<br />
SBA - Sociedade Brasileira de Automática – Bonito(MS) -<br />
Brasil Set-2010 pp:3383-3390<br />
Abstract: This paper evaluates the effectiveness of the<br />
Interline Power Flow Controller (IPFC) for improving smallsignal<br />
stability of electric power systems. The IPFC power<br />
injection model and its differential equations are included in the<br />
power flow. The dynamic analysis is performed using the<br />
power sensitivity model. Simulations in a two area test system<br />
show that the IPFC equipped with a POD can provide the<br />
damping of the critical oscillation modes, improving the system<br />
dynamic performance, in addition to the flexibility to control<br />
the transmission lines power flows.<br />
Keywords: FACTS, IPFC, POD, Power Systems, Smallsignal<br />
Stability<br />
Conteúdo Harmônico da Corrente e Tensão de<br />
Arcos Elétricos Gerados Artificialmente em<br />
Ambiente Não Confinado<br />
Maria Cristina Dias Tavares, Jonas Lemos Talaisys, Carlos<br />
Medeiro Portela, Alessandra Benevides Camara<br />
In: XVIII Congresso Brasileiro de Automática (CBA 2010)-<br />
Antonio Padilha Feltrin(Ed.) - ISBN: 978-85-61507-02-2<br />
SBA - Sociedade Brasileira de Automática – Bonito(MS) -<br />
Brasil Sep-2010 pp:1185-1192<br />
Abstract: In this paper the harmonic content of current and<br />
voltage between terminals of 543 electrical arcs artificially<br />
generated were obtained by applying the Windowed Fourier<br />
Transform. This application is based on shifting a window on<br />
the signs in study and calculating the coefficients of the<br />
Discrete Fourier Transform, allowing a time-frequency analysis<br />
of signals. A statistical analysis of the results has permitted the<br />
identification of a harmonic signature of electrical arc.<br />
Keywords: Secondary arc, harmonic analysis, singlephase<br />
autoreclosing, non-permanent faults<br />
Enhancement of Data Rate for User Cooperation<br />
Mitchell Omar Calderon Inga, Gustavo Fraidenraich<br />
In: IEEE/SBrT International Telecommunications Symposium<br />
ITS 2010-Rafael Dueire Lins(Ed.) - ISBN: 978-85-89748-05-6<br />
Manaus(AM) Brasil Sep-2010 pp:1 - 6<br />
Abstract: In this paper, we propose a different scheme based<br />
on user cooperation diversity, in which we obtain an increase in<br />
the data rate. In particular, we present performance analysis<br />
using conventional CDMA (code division multiple access)<br />
implementation for two users. Cooperation among users has<br />
been shown to achieve significant gains as compared to a noncooperative<br />
system. The results presented here show that the<br />
new scheme of cooperation achieves substantial increase of<br />
data rate, keeping the average bit error probability close to<br />
values obtained in [3]. Regarding the number of spreading<br />
codes, there are costs associated with our cooperative scheme,<br />
but even so our proposed strategy leads not only to an increase<br />
in throughput but also to a simpler system.<br />
Keywords: user cooperation, virtual MIMO, bit error<br />
probability.<br />
Estratégia de Controle e Análise do Filtro<br />
Híbrido Utilizando um Inversor de Potência<br />
Reduzida<br />
Newton Soares Da Silva, Jose Antenor Pomilio, Edson Adriano<br />
Vendrusculo<br />
In: XVIII Congresso Brasileiro de Automática (CBA 2010)-<br />
Antonio Padilha Feltrin(Ed.) - ISBN: 978-85-61507-02-2<br />
SBA - Sociedade Brasileira de Automática – Bonito(MS) -<br />
Brasil Sep-2010 pp:867-872<br />
78 Sinopse da <strong>FEEC</strong>