Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
Power Analysers & Recorders cont'd. - Ferret
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
volume 37 issue 17<br />
techrentals<br />
your rental business partner<br />
TEST & MEASUREMENT<br />
Rental Solutions Guide
TechRentals A<br />
1800 632 652<br />
www.techrentals.com.au<br />
rent@techrentals.com.au<br />
<br />
169 South Road<br />
<br />
<br />
P 08 8302 8800 | F 08 8302 8899<br />
<br />
<br />
<br />
Queensland 4108<br />
P 07 3100 7650 | F 07 3100 7699<br />
<br />
<br />
<br />
<br />
P 08 8947 2860 | F 08 8947 2901<br />
TechRentals<br />
<br />
603 5632 1135<br />
<br />
SELANGOR D.E<br />
<br />
<br />
Selangor Darul Ehsan<br />
<br />
P +60 3 5632 1135<br />
F +60 3 5632 5409<br />
Gold Coast<br />
103-105 Spencer Road<br />
Nerang<br />
Queensland 4211<br />
P 07 5596 3451 | F 07 5596 4119<br />
<br />
6 Joseph Street<br />
<br />
<br />
P 03 9896 3000 | F 03 9896 3099<br />
Newcastle<br />
<br />
Thornton<br />
New South Wales 2322<br />
P 02 4966 5910 | F 02 4966 3586<br />
TechRentals<br />
New Zealand*<br />
0800 832 473<br />
www.techrentals.co.nz<br />
AUCKLAND<br />
669 Great South Road<br />
Penrose Auckland<br />
New Zealand<br />
P +64 9 589 2030<br />
F +64 9 589 2031<br />
<br />
<br />
Perth<br />
122 Kewdale Road<br />
Kewdale<br />
<br />
P 08 9441 3900 | F 08 9441 3999<br />
<br />
<br />
<br />
New South Wales 2116<br />
P 02 9933 1100 | F 02 9933 1199<br />
<br />
<br />
<br />
Queensland 4817<br />
P 07 4773 7788 | F 07 4723 5397<br />
TR VMS<br />
<br />
BRISBANE<br />
72 Donaldson Road<br />
Rocklea<br />
Queensland 4106<br />
P 07 3717 9100<br />
F 07 3717 9135<br />
SYDNEY<br />
<br />
Prestons<br />
New South Wales 2170<br />
P 02 8777 0800<br />
F 02 8783 5171
Contents<br />
<br />
1. stretch your budget<br />
<br />
<br />
<br />
<br />
2. utilise operating expense<br />
<br />
<br />
<br />
<br />
3. conduct product research before purchasing<br />
<br />
<br />
<br />
4. recover costs more quickly<br />
<br />
<br />
†<br />
5. eliminate running costs<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
7. respond to sudden demands<br />
<br />
<br />
<br />
8. apply new technologies & avoid obsolescence<br />
<br />
<br />
<br />
superseded.<br />
9. preserve credit<br />
<br />
<br />
<br />
10. technical support<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Measurement 44 - 57<br />
<br />
<br />
<br />
<br />
<br />
Other Products 78<br />
Visit TechRentals Wiki<br />
Save your time and reduce<br />
your real costs. Find out all<br />
<br />
<br />
This resource centre provides manuals,<br />
technical information and how-to videos.<br />
www.techrentals.com.au select Technical<br />
Tips and Videos.<br />
<br />
<br />
<br />
techrentals bearcom vidcom telecom<br />
minecom<br />
1
A<br />
AC See Electrical <strong>Power</strong> 29<br />
AC Electrical Chart <strong>Recorders</strong> 36<br />
AC Sources/Inverters/Generators 43<br />
AC Voltage Current Chart <strong>Recorders</strong> 36<br />
Accelerometer 62<br />
Adhesion Tester 58<br />
Air<br />
Flow 64, 65, 72<br />
Quality 56, 64, 65, 72<br />
Air Balancing Hood 64, 65<br />
Air Conditioner Valve Balancing 65<br />
Air Conditioning<br />
Coolant Flow 76<br />
Electronic Manifold 65<br />
Measurement 64<br />
Valve Balancing 65<br />
Air Conditioning & Air Flow 64<br />
Air Quality<br />
Monitoring 64, 70, 71, 72<br />
Particles 71<br />
Pressure & Humidity 64, 72<br />
Air Quality & Heat Stress 72<br />
Air Velocity Meter 64<br />
Airborne Dust & Particle Meter 71<br />
Airspeed and Altimeter Calibration Kit 48<br />
Alcohol Breath Analyser 71<br />
Alignment 48, 62<br />
Anemometer 64, 65<br />
Antenna & Cable Test 16, 18<br />
Antennas 21<br />
Appliance Tester 30, 31<br />
Area Air Quality 70<br />
Area Heat Stress 72<br />
Audio <strong>Analysers</strong> 18<br />
Autoclave Logger 54<br />
B<br />
Balances 61, 77<br />
Balances & Scales Below 8kg 77<br />
Balancing Machinery 65<br />
Balometer 64, 65<br />
Barometric Logger 75<br />
Bath<br />
Constant Temperature 48, 51<br />
Ultrasonic 57<br />
Battery Management Systems 43<br />
Blast Logger 62<br />
Body Vibration Measurement 62<br />
Bore Hole Water Quality 74, 75<br />
Borescopes 46, 47<br />
Bridge LCR 10<br />
C<br />
Cable<br />
Fault Locator 29<br />
LAN Test 22<br />
Locator 22, 29, 66, 67<br />
Tester 22, 29<br />
Cable & Fault Locator 66<br />
Cable & Pipe Tracers & Fault Locators 29<br />
Cable Locator 66, 67<br />
Calibrator<br />
Current 12, 48, 51<br />
Current Loop 12, 48, 49, 50, 51<br />
Dry Block Temperature 48, 51<br />
Hydraulic 48, 49, 51<br />
Industrial 48, 51<br />
Intrinscially Safe Loop 49<br />
Laboratory 12, 50<br />
Loop 48, 51<br />
Pneumatic Instruments 48, 51<br />
Pressure 48, 49, 50, 51<br />
Process 48, 49, 50, 51<br />
Resistance 12, 48, 49, 50, 51<br />
Temperature 48, 50, 51<br />
Voltage 12, 48, 49, 50, 51<br />
Caliper 60<br />
Camera<br />
Endoscope 46<br />
High Speed 47<br />
Pipe Inspection 46, 47, 67, 68<br />
Surveillance 78<br />
Thermal Imaging 45, 46<br />
Video 47<br />
Carbon Dioxide (CO 2 ) 57, 70, 72<br />
Carbon Monoxide & Nitrogen Dioxide Monitors 70<br />
Carbon Monoxide (CO) 57, 70, 71, 72<br />
Cat 5, 5E, 6 22<br />
Charge Amplifier 62<br />
Chart Recorder 52, 55<br />
Chemical & Analytical 77<br />
Circuit Breaker Analyser 42<br />
Circuit Tracer 29<br />
Clamp Meter 36<br />
Clamp-on Sensors 36<br />
Clean Room Monitor 71<br />
Cleaver - Fibre Optic 25, 26<br />
Coating Thickness 58, 60<br />
Combustion Gas Analysis 57<br />
Combustion, Flue & Industrial Gas <strong>Analysers</strong> 57<br />
Communication Test Sets 18<br />
Compressor Output<br />
Flow 72<br />
Quality 72<br />
Concrete Cover Meter 65<br />
Concrete Hardness Tester 66<br />
Concrete Testing<br />
Adhesion 58<br />
Cover Meter 65, 66<br />
Moisture Meter 66, 68<br />
Reo Depth 66<br />
Test Hammer 66<br />
Concrete Testing Equipment 65<br />
Conductivity & Salinity 75<br />
Conductivity Probe 75<br />
Confined Space Entry 70, 71<br />
Construction, Building Services & Survey 64<br />
Air Conditioner Valve Balancing 65<br />
Air Conditioning & Air Flow 64,65<br />
Concrete Testing Equipment 65, 66<br />
Distance Measurement & Surveying 68<br />
Ground Penetrating Radar 67<br />
Material Moisture Meters 68<br />
Pipeline & Cavity Inspection 67, 68<br />
Underground Service Location 66, 67<br />
Utility Leak Detection 67<br />
Counting Scales 61, 77<br />
Crane Scales 61<br />
Current<br />
Clamp 34, 35, 36, 37, 38, 42<br />
DC Source 10<br />
Injection 42<br />
Input Logger 53<br />
Loop 48, 50, 51<br />
Meter 34, 36, 37, 56, 76<br />
Primary Injection 42<br />
Probe 9, 30, 36, 37, 38<br />
Secondary Injection 42<br />
Transducer 36, 38<br />
Transformer (CT) 36<br />
Current Clamps Probes & Accessories 36, 37, 38<br />
Current Injectors 42<br />
D<br />
Data & Telecommunications 22<br />
DSL/POTS Test Set 24<br />
Ethernet Analyser 22<br />
Ethernet Loopback 22<br />
Ethernet Test Set 22<br />
Etherscope 22<br />
Fibre Optic Launch Cables & Patch Leads 27<br />
Fibre Optics 27<br />
Fusion Splicers 25, 26<br />
LAN Analyser 22<br />
LAN Cable Certifiers 22<br />
LAN Cable Testers 22<br />
LAN/WAN <strong>Analysers</strong> 22, 23<br />
Light Source 25<br />
Light Sources & <strong>Power</strong> Meters 24, 25<br />
Microwave Link <strong>Analysers</strong> 27<br />
OTDR, FC & Fibre Accessories 26, 27<br />
PDH/SDH <strong>Analysers</strong> 23, 24<br />
Permanent Link Adaptors 22<br />
WAN <strong>Analysers</strong> 22<br />
Data Loggers 53, 54, 55<br />
DC High Voltage 9, 36, 37, 38, 39<br />
DC <strong>Power</strong> Supplies 10, 12<br />
DC <strong>Power</strong> Supplies & Loads 10, 12<br />
Decade Resistance Box 12, 50<br />
Demand Analyser 32<br />
Dewpoint 72<br />
Digital Pressure Gauge 56<br />
Digital Storage Oscilloscopes 8, 9<br />
Dimension Measurement 60<br />
Dissolved Oxygen 75<br />
Distance Measurement 68<br />
Distance Measurement & Surveying 68<br />
Distortion <strong>Analysers</strong> 18<br />
Dry Block Calibrators 51<br />
DSL/POTS 24<br />
Ductor 31, 32<br />
2<br />
Dust Measurement 71, 72<br />
E<br />
E & H Field Strength Meter Gauss 13<br />
E & H Field Strength Meters 13<br />
E1/E3 Tester 23, 24<br />
Earth Leakage 30, 31, 36, 38, 39, 40<br />
Earth Testers 31<br />
Electrical Cable Test 31, 36, 38, 39, 40<br />
High Voltage 39<br />
Surge Generator 29<br />
TDR 29<br />
VLF 39<br />
Electrical Installation & Test<br />
Appliance Tester 30, 31<br />
Earth Leakage (RCD) 31, 36, 38, 39, 40<br />
High Voltage Test (Hipot) 39, 40<br />
Insulation Oil Tester 39<br />
Insulation Test 29, 30, 31, 32, 36, 38, 39, 40<br />
Resistance Test 31, 32, 38<br />
Soil/Ground Resistance 31<br />
VLF Testers 39<br />
Electrical <strong>Power</strong> 29<br />
AC Electrical Chart <strong>Recorders</strong> 36<br />
AC Sources/Inverters/Generators 43<br />
Battery Management Systems 43<br />
Cable & Pipe Tracers & Fault Locators 29<br />
Current Clamp Probes & Accessories 36, 37<br />
Current Injectors 42<br />
Electrical Testers 29, 30<br />
Insulation Testers & Meggers to 20kV 38, 39<br />
Micro-Ohm Meters & Earth Testers 31, 32<br />
Oil, Hipot & VFL Testers above 20kV 39, 40<br />
PAT Testers & RCD Testers 30, 31<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> 32, 34, 35, 36<br />
<strong>Power</strong> Line Conditioners/UPS 43<br />
<strong>Power</strong> Transformers 43<br />
<strong>Power</strong> Transformer Testers 40<br />
Protection Relay Testing Systems 42, 43<br />
Electrical <strong>Power</strong> Generation & Transmission 29<br />
Current Injection 42<br />
High Voltage Test (Hipot) 39<br />
<strong>Power</strong> Quality 29, 30, 32, 34, 35, 36<br />
Protection Relay Test 42<br />
VLF Test 39<br />
Electrical <strong>Power</strong> Quality<br />
Harmonics 29, 32, 35, 36<br />
<strong>Power</strong> Factor 29, 30, 32, 35, 36<br />
<strong>Power</strong> Quality Analyser 32, 34, 35, 36<br />
Voltage Current <strong>Recorders</strong> 36<br />
Electrical <strong>Power</strong> Sources<br />
Battery Management Systems 43<br />
Current Injectors 42<br />
Generators 43<br />
Line Conditioners 43<br />
Programmable 43<br />
UPS 43<br />
Electrical Testers 29, 30<br />
Electrical Transducers 29<br />
Electrochemistry 74<br />
Electrometer 8<br />
Electronic Load 10<br />
Electronics 8<br />
DC <strong>Power</strong> Supplies & Loads 10, 12<br />
Digital Storage Oscilloscopes 8, 9<br />
E & H Field Strength Meters 13<br />
EMC & <strong>Power</strong> Distrubance Simulators 13<br />
Function Generators 10<br />
Gauss/Tesla Meters 13<br />
Laborator Calibrators 12<br />
LCR Meters 10<br />
Logic <strong>Analysers</strong>/PROM Programmers 12<br />
Multimeters & Electrometers 8<br />
Probes and Accessories 9, 10<br />
Spectrum <strong>Analysers</strong> - Low Frequency 12<br />
TV Test Equipment 12<br />
Electrostatic Charge Measurement 8<br />
Electrostatic Meter 8<br />
EMC & <strong>Power</strong> Disturbance Simulators 13<br />
EMC Test Equipment 13<br />
EMC/EMI Test Equipment 13<br />
Endoscopes 46, 47, 68<br />
Endoscopes Borescopes Visual Inspection 46<br />
Environment,OHS, Chemical & Laboratory 70<br />
Air Quality & Heat Stress 72<br />
Airborne Dust & Particle Meters 71<br />
Balances & Scales below 8kg 77<br />
Chemical & Analytical - General 77<br />
Environment Flow Meters 76<br />
Environmental Gas & Vapour Meters 70, 71<br />
Floor Slip Testers 74
Laboratory & Hand-held Microscopes 77<br />
Laboratory Instruments, Spectroscopy 77<br />
Light Meters, UVA/B/C Measurement 76<br />
Moisture & Humidity Meters 72<br />
Noise & Sound <strong>Analysers</strong> 72, 73<br />
Personal Gas & Vapour Monitors 71<br />
Radiation Monitoring & Protection 74<br />
Water Quality, pH Meters & Electrochem 74, 75<br />
Weather Stations 76<br />
Environmental Chambers/Oven 57<br />
Environmental Flow Meters 76<br />
Environmental Gas & Vapour Meters 70<br />
Environmental Noise 72<br />
Environmental Noise Logger 72, 73<br />
Environmental Test Chambers/Ovens 57<br />
Ethernet Loopback 22<br />
Ethernet Test Set 22<br />
Excavator Cable Locator 66<br />
F<br />
Fault Locator 29, 67<br />
Fault Loop Impdenace Tester 30<br />
Fibre Inspection & Test Kit 27<br />
Fibre Inspection-Capture Probe 27<br />
Fibre Optic Launch Cables & Patch Leads 27<br />
Fibre Optics 27<br />
Cleaver 25, 26<br />
Fibre Inspection & Test Kit 27<br />
Fibre Inspection-Capture Probe 27<br />
Fusion Splicers 25, 26<br />
Fibrescope 68<br />
Field Strength Meters 13<br />
Flash Card 52, 53<br />
Floor Slip Testers 74<br />
Flow Hood 64, 65<br />
Flow Meters 56, 57, 76<br />
Compressed Air 56<br />
Doppler 56, 57<br />
Gas 56, 64<br />
Liquid 56, 57, 76<br />
Non-Intrusive 56, 57<br />
Open Channel 56, 76<br />
Transit Time 56, 76<br />
Ultrasonic 56, 57, 76<br />
Flow Meters for Liquids & Gases 56<br />
Flue Gas Analysis 57<br />
Flue Inspection 46, 68<br />
Force Gauges 60<br />
Formaldehyde Meter 70<br />
Frequency Counters 14<br />
Frequency Response Analyser 40<br />
Function Generators 10<br />
Fusion Splicers 25, 26<br />
G<br />
Gamma Radiation 74<br />
Gas 70<br />
Alcohol 71<br />
Carbon Dioxide (CO 2 ) 57<br />
Carbon Monoxide (CO) 57<br />
Flammable (LEL) 70, 71<br />
Formaldehyde 70<br />
Hydrogen Sulphide (H 2 S) 70, 71<br />
Methane (CH 4 ) 70<br />
Nitric Oxide (NO) 57<br />
Nitrogen Dioxide (NO 2 ) 57<br />
Oxygen (O 2 ) 57<br />
Ozone (O 3 ) 70<br />
Refrigerant 70<br />
Sulphur Dioxide (SO 2 ) 70<br />
VOC 70, 71<br />
Gas & Vapour Meters 70<br />
Gas Analysis & Monitoring 57, 70, 71<br />
Gauss/Tesla Meters 13<br />
General Industrial & Process Measurement 44<br />
Combustion, Flue & Industrial Gas <strong>Analysers</strong> 57<br />
Data Loggers 53, 54, 55<br />
Dry Block Calibrators 51<br />
Endoscopes Borescopes Visual Inspection 46, 47<br />
Environmental Test Chambers/Ovens 57<br />
Flow Meters for Liquids & Gases 56, 57<br />
High Speed Video Inspection Cameras 47<br />
High Speed Waveform <strong>Recorders</strong> 52, 53<br />
Industrial Process Calibrators 48, 49, 50, 51<br />
Infrared Thermal Imaging Cameras 45, 46<br />
Laser Rotational Shaft Alighment 48<br />
Pressure & Humidity Transducers 55<br />
Pressure Vacuum Gauges/<strong>Recorders</strong> 55, 56<br />
Strip Chart <strong>Recorders</strong> 52<br />
Tachometers/Stroboscopes 47<br />
Temperature Meters/IR Thermometers 44<br />
Ultrasonic Baths 57<br />
Generator (AC) 43<br />
Ground Penetrating Radar 67<br />
H<br />
Hardness Testers 58<br />
Harmonics (<strong>Power</strong>) 32, 34, 36<br />
Hart Communicators 49<br />
Heat Stress 72<br />
High Frequency Spectrum <strong>Analysers</strong> 14, 16<br />
High Speed Video Cameras 47<br />
High Speed Video Inspection Cameras 47<br />
High Speed Waveform <strong>Recorders</strong> 52<br />
High Voltage Insulation DielectricsTest Set 40<br />
Hipot Testers 39<br />
Holiday Detector 58<br />
Hot Wire Anemometer 64, 65<br />
Humidity<br />
Chamber 57<br />
Concrete 65<br />
High Temperature Probe 55<br />
Indoor Air 72<br />
Logging 53, 54, 55<br />
Natural Gas 72<br />
Thermohygrograph 72<br />
Transducers 55<br />
Weather 76<br />
HVAC & IAQ 56, 64, 65, 72<br />
Hybrid <strong>Recorders</strong> 52<br />
Hydraulic Pressure 48, 49, 58<br />
I<br />
Illuminance Meter 76<br />
Inclinometers 60<br />
Indoor Air Quality 72<br />
Industrial Process Calibrators 48, 51<br />
Infrared Cameras 45, 46<br />
Infrared Thermal Imaging Cameras 45<br />
Infrared Thermometers 44<br />
Injection Test Set 42<br />
Instrumentation Amplifier 52<br />
Insulation Testers 30, 31, 38<br />
Insulation Testers & Meggers to 20kV 38, 39<br />
Intrinsically Safe<br />
Current Loop Calibrator 48<br />
Digital Multimeter 8<br />
Gas Monitor 70, 71<br />
Moisture Analyser 72<br />
Photo-Ionisation Detector (PID) 70, 71<br />
Inverter 43<br />
Ionisation Testers 39<br />
IR Thermometers 44<br />
L<br />
Laboratory & Hand-held Microscopes 77<br />
Laboratory Calibrators 12, 50<br />
Laboratory Ovens 57<br />
LAN<br />
<strong>Analysers</strong> 22<br />
Cable Certification 22<br />
Cable Testers 22<br />
LAN <strong>Analysers</strong>/Management 22<br />
LAN Cable Testers 22<br />
LAN/WAN <strong>Analysers</strong> 22<br />
Laser<br />
Distance & Speed 62, 68<br />
Laser Rotational Shaft Alignment 48<br />
LCR Meters 10<br />
Leak Detector<br />
Gas Pipe 67, 70<br />
Microwave Oven 74<br />
Refrigerant 70<br />
Water 67<br />
Light Measurement 76<br />
Light Meters, UVA/B/C Measurement 76<br />
Light Source 25<br />
Light Sources & <strong>Power</strong> Meters 24, 25<br />
Linear Position Transducer 60<br />
Liquid Flow Loggers 76<br />
Liquid Flow Meters 56<br />
Load Cells 60, 61<br />
Logger See also <strong>Recorders</strong> 53<br />
Accessories 53<br />
Autoclave 53<br />
Data 53, 54, 55<br />
Explosion 62<br />
Flow 56<br />
Humidity 53, 54, 55<br />
Temperature 53, 54, 55<br />
Logic <strong>Analysers</strong> 12<br />
Logic <strong>Analysers</strong>/PROM Programmers 12<br />
3<br />
<br />
Logic Programmer 12<br />
Low Frequency Spectrum <strong>Analysers</strong> 12<br />
Luminance Meter 76<br />
Lux Meter 76<br />
M<br />
Magnetic Field Meter 13<br />
Manometer 64, 65<br />
Material Moisture Meters 68<br />
Material Testing 77<br />
Memory <strong>Recorders</strong> 52<br />
Metal Detectors 78<br />
Methane Monitor 70<br />
Micrometers 60<br />
Micro-Ohm Meters 31, 32<br />
Micro-Ohm Meters & Earth Testers 31<br />
Microscopes 77<br />
Microwave Leakage Detectors 74<br />
Microwave Link <strong>Analysers</strong> 27<br />
Microwave Oven Survey Meters 74<br />
Modified Atmosphere<br />
Packaging Test 57<br />
Moisture<br />
Concrete 66, 68<br />
Timber 68<br />
Wood 66<br />
Moisture & Humidity Meters 72<br />
Moisture <strong>Analysers</strong> 72<br />
Moisture Balance 77<br />
Multimeters 8<br />
Multimeters & Electrometers 8<br />
N<br />
Natural Gas 72<br />
Network <strong>Analysers</strong><br />
Antenna & Cable Test 16, 18<br />
Cable Test 16<br />
<strong>Power</strong> 32, 35<br />
RF 16<br />
Network <strong>Analysers</strong>/Antenna & Cable Test 16<br />
Noise & Sound 72<br />
Noise & Sound <strong>Analysers</strong> 72<br />
Noise Loggers 72, 73<br />
Non-Destructive Testing (NDT) 58, 60<br />
Non-tripping Loop Tester 32<br />
O<br />
Occupational Health & Safety 70<br />
Air Quality 56, 64, 65, 72<br />
Appliance Testing 30<br />
Confined Space Entry 70, 71<br />
Floor Slip Tester 74<br />
Formaldehyde 70<br />
Heat Stress 72<br />
Lighting 76<br />
Noise & Sound 72<br />
Ozone 70<br />
Radiation 13, 74<br />
UV Exposure 76<br />
Vibration 62<br />
Volatile Organic Compound 70<br />
ODM Optical Dispersion Measurement 27<br />
Oil Insulation Testers 39, 40, 42<br />
Oil, Hipot & VLF Testers Above 20kV 39<br />
Oscilloscopes<br />
Digital Storage 8, 9<br />
Portable 8, 9<br />
OTDR 26, 27<br />
OTDR, FC & Fibre Accessories 26, 27<br />
Other Products<br />
Prospecting Metal Detectors 78<br />
Retail Customer Traffic Flow Counters 78<br />
Security Equipment 78<br />
Oven 57<br />
Oxygen & CO 2 Analyser 57, 70, 71<br />
Oxygen (O 2 ) 57, 70, 71<br />
Ozone (O 3 ) 70<br />
P<br />
Particle Counters 71<br />
PAT 30, 31<br />
PAT Testers & RCD Testers 30<br />
PDH <strong>Analysers</strong> 23<br />
PDH/SDH <strong>Analysers</strong> 23<br />
Pen Plotter 9<br />
People Traffic Flow Counter 78<br />
Permanent Link Adaptors 22<br />
Personal Gas & Vapour Monitors 71<br />
pH Measurement 74, 75<br />
pH Meters 74<br />
pH reading for Meat Standards 75
pH, mV & Temperature Measurement 75<br />
Photo-Ionisation Detector (PID) 70, 71<br />
Physical Measurement 58, 60<br />
Force Gauges 60<br />
Inclinometers 60<br />
Load Cells 60, 61<br />
Material Hardness Testers 58<br />
Micrometers 60<br />
Non-Destructive Testing 58, 60<br />
Position Transducers 60<br />
Speed Measurement 62<br />
Vibration Analysis 62<br />
Weighing & Counting Scales over 8kg 61<br />
Pinhole Detector 58<br />
Pipe Locators 66, 67<br />
Pipeline & Cavity Inspection 67<br />
Pipeline Camera Inspection System 68<br />
Pipeline Inspection 46<br />
Pitot Tube 64<br />
Plotter 9<br />
Pobes & Accessories 9<br />
Portable Appliance Testers 30, 31<br />
Position Transducer 60<br />
Position Transducers 60<br />
POTS 24<br />
<strong>Power</strong> See Electrical <strong>Power</strong> 29<br />
<strong>Power</strong> <strong>Analysers</strong> 32, 36<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> 32, 34, 36, 37<br />
<strong>Power</strong> Demand Analyser 32<br />
<strong>Power</strong> Disturbance 29, 30, 32, 34, 35, 36, 37<br />
<strong>Power</strong> Line Conditioners 43<br />
<strong>Power</strong> Line Conditioners/UPS 43<br />
<strong>Power</strong> Loggers 37<br />
<strong>Power</strong> Meter - RF 19<br />
<strong>Power</strong> Meters 19<br />
<strong>Power</strong> Meters & Sensors 19<br />
<strong>Power</strong> Supplies - DC 10, 12<br />
<strong>Power</strong> Transformer Testers 40<br />
<strong>Power</strong> Transformers 43<br />
Pressure<br />
Calibrator 48, 49, 50, 51<br />
Circular Chart Recorder 55<br />
Indicator/Gauge 55, 56<br />
Logging Gauge 55, 56<br />
Transducers 55<br />
Pressure & Humidity Transducers 55<br />
Pressure Pump 51<br />
Pressure Transducer 49, 50<br />
Pressure Vacuum Gauge/<strong>Recorders</strong> 55<br />
Probe<br />
Current 9, 30, 36, 37, 38, 42<br />
High Voltage 9<br />
Line Logic 53<br />
Process Calibrator 49, 50, 51<br />
Programmer<br />
EPROM, EEPROM 12<br />
PROM Programmers 12<br />
Prospecting Metal Detectors 78<br />
Protection Relay Test 42, 43<br />
Protection Relay Testing Systems 42<br />
Pulse Porosity Detectors 58<br />
Pumps 48, 49, 51<br />
R<br />
Radar Speed Gun 62<br />
Radiation Monitor 13, 74<br />
Radiation Monitoring & Protection 74<br />
Radiation Monitors 74<br />
Radio Frequency 14<br />
Accessories - RF 21<br />
Amplifiers - RF 19<br />
Antennas 21<br />
Attenuators - RF 19, 21<br />
Communiation Test Sets 18<br />
Distortion <strong>Analysers</strong> 18<br />
Frequency Counters 14<br />
Network <strong>Analysers</strong>/Antenna & Cable Test 16, 18<br />
<strong>Power</strong> Meters - RF 19<br />
Signal & Sweep Generators - RF 14<br />
Spectrum <strong>Analysers</strong> - High Frequency 16<br />
Radiometer 76<br />
RCD Test 30, 38<br />
<strong>Recorders</strong> 53<br />
Chart 52, 55<br />
Hybrid 52<br />
Memory 52, 53<br />
Pressure 55<br />
Temperature Humidity 54<br />
Refrigerant Leak Detection 70<br />
Relay Test 40, 42, 43<br />
Resistance<br />
Calibration 12, 48, 50, 51<br />
Decade 12, 50<br />
Ground/Soil 31<br />
Micro-Ohm 31, 32<br />
Static 38<br />
Tester 30, 31, 36, 38, 39, 40<br />
Retail Customer Traffic Flow Counters 78<br />
RF See also Radio Frequency 14<br />
RF Accessories 21<br />
RF Amplifiers 19<br />
RF Attenuators 19, 21<br />
RF Signal & Sweep Generators 14<br />
RF Signal Generators 14<br />
RF Sweep Generators 14<br />
Rotating Balancing 62<br />
Roughness 58<br />
Router Test System 23<br />
RTD Calibrator 48<br />
S<br />
Safety Bolt Inspection System 60<br />
Salinity & Conductivity 75<br />
Scales 61, 77<br />
Scanning Receiver 18<br />
Scopemeter 8<br />
SDH <strong>Analysers</strong> 23<br />
Security<br />
Metal Detector 78<br />
Surveillance 78<br />
Security Equipment 78<br />
Sensors - RF 19<br />
Shaft Alignment 48, 62<br />
Shaker Table 62<br />
Signal Generators<br />
RF 14<br />
Smoke Generating Machine 64<br />
Soil Resistivity 31<br />
Sonde 66, 67<br />
Sound<br />
Measurement 72<br />
Signal Analysis 72<br />
Sound Level Meter 62, 72, 73<br />
Vibration 62<br />
Spectrophotometer 77<br />
Spectroscopy 77<br />
Spectrum Analyser<br />
High Frequency 14, 16<br />
Low Frequency 12<br />
RF 14, 16<br />
Spectrum Analyser – Low Frequency 12<br />
Spectrum <strong>Analysers</strong> – High Frequency 14<br />
Speed Measurement 62<br />
Splicer - Fibre Optic 25, 26<br />
Startup Current 34, 35, 36, 37, 38<br />
Static Discharge Generator 13<br />
Step Transformer 13<br />
STM1 ... STM64 23, 24<br />
Strip Chart <strong>Recorders</strong> 52<br />
Stroboscope 47<br />
Surface Roughness 58<br />
Surge Generator 29<br />
Surge Transient Generator<br />
EMC/EMI Test 13<br />
Sweep Generators 14<br />
T<br />
Tachometers 47<br />
Tachometers/Stroboscopes 47<br />
Tan Delta Measurement 40<br />
TDR 29<br />
Telecommunications<br />
Access Tester 23, 24<br />
<strong>Analysers</strong> 22, 23<br />
CDMA 19<br />
Communications <strong>Analysers</strong> 27<br />
PDH 23, 24<br />
POTS 24<br />
SDH 23, 24<br />
Temperature<br />
IR Thermometer 44<br />
Logging 54<br />
Probe 44<br />
Thermocouple 44<br />
Thermometer 44<br />
Temperature Meters 44<br />
Temperature Meters/IR Thermometers 44<br />
Tension 60<br />
Test & Tagging 30, 31<br />
Test Chamber 57<br />
Thermal Imaging Camera 45, 46<br />
Thermocouple 44<br />
4<br />
Thermohygrograph 72<br />
Thickness Gauge 58<br />
Time Domain Reflector 29<br />
TDR 29<br />
Torque Wrench 60<br />
Total Dissolved Solids (TDS) 75<br />
Tracking Generator 14<br />
Transducers<br />
Current 38<br />
Electrical 29<br />
Frequency 36<br />
Humidity 55<br />
Position 60<br />
Pressure 55<br />
Temperature 55<br />
Transformer Oil Test 42<br />
Transient Burst 13<br />
Transport<br />
Inclinometers 60<br />
Turbidity 74, 75<br />
TV Test Equipment 12<br />
U<br />
Ultrafine Particle Counter 71<br />
Ultrasonic Baths 57<br />
Underground Services Location 66<br />
Uninterruptable <strong>Power</strong> Supplies - UPS 43<br />
USB to RS232 Converter 10<br />
Utility Leak Detection 67<br />
UV Exposure 76<br />
V<br />
Valve Balancing (Air Conditioning) 65<br />
Variacs 43<br />
Ventilation Meter 65<br />
Vibration<br />
Accelerometer 62<br />
Analyser 62<br />
Blast Logging 62<br />
Impact Hammer 62<br />
Table 62<br />
Whole Body 62<br />
Vibration Analysis 62<br />
Video<br />
Endoscope 47<br />
High Speed 47<br />
Microscope 77<br />
Pipeline Inspection 46, 47, 67, 68<br />
Video Microscope Kit 77<br />
Video Microscopes 77<br />
Video Security 78<br />
Viscometer 77<br />
Visual Inspection 46, 47, 67, 68<br />
Visual Inspection Equipment 46<br />
VLF MV Cable Test 39<br />
VOC Monitor 70<br />
Volatile Organic Compound 70<br />
Volatile Organic Compounds (VOC) 70, 71<br />
Voltage Calibrator 48, 51<br />
W<br />
Walk Through Metal Detector 78<br />
WAN <strong>Analysers</strong> 22, 23<br />
Water<br />
Analysis 74<br />
Conductivity 75<br />
Depth 56, 74, 75, 76<br />
Depth Measurement 74<br />
Flow 56, 57, 76<br />
pH 74, 75<br />
Quality 74, 75<br />
Sampling 74<br />
Water Quality, pH Meters & Electrochem 74<br />
Water/Oil Bath Temp Calibrator 48, 51<br />
WBGT 72<br />
Weather 76<br />
Weather Stations 76<br />
Weighing & Counting Scales Over 8kg 61<br />
Wind Speed & Direction 65, 76<br />
Wind Turbine Lightning Protection Test Lead Set 32<br />
Wood & Masonry Testing<br />
Moisture Meter 66<br />
Workplace Safety<br />
See Environment,OH&S, Chemical & Laboratory 70<br />
X<br />
X-Ray Measurement 74
ABACUS<br />
ABA,301<br />
ACTERNA<br />
71<br />
ACT,ANT-5 - STM16 24<br />
ACT,ANT5 - STM4 23<br />
ACT,EDT-135 24<br />
ACT,MTS8000 24<br />
ACT,OLA-55<br />
ADVANTEST<br />
25<br />
ADV,TR1720 21<br />
ADV,U3771<br />
AERQUAL<br />
14<br />
AER,500L<br />
AGILENT<br />
(Also see Hewlett-Packard)<br />
70<br />
AGI,53151A 14<br />
AGI,MSO6104A 8<br />
AGI,MSOX3024A 8<br />
AGI,N9340A-TG 14<br />
AGI,N9912A<br />
AH SYSTEMS<br />
16<br />
AH,ANTENNA 21<br />
AH,SAS-200/550 21<br />
AH,SAS-200/571 21<br />
AH,SAS-571<br />
AIC<br />
21<br />
AIC,SG-AST-500<br />
AIRMAGNET<br />
60<br />
AIR,AIRMAG SPEC AN<br />
AIRFLOW<br />
16<br />
AIR,AV2 64<br />
AIR,AV2-NATA 64<br />
AIR,PITOT-36<br />
ALNOR<br />
64<br />
ALN,EBT-721-Z3<br />
AMETEK<br />
64<br />
AME,CADET-25N 60<br />
AME,HL2700N 48<br />
AME,PPCE-NATA<br />
A&D MERCURY<br />
48<br />
AND,FC-10K 61<br />
AND,FG-150KB 61<br />
AND,FS-15KA 61<br />
AND,HF-300G 77<br />
AND,HP-40KA 61<br />
AND,MX50<br />
ANRITSU<br />
77<br />
ANR,50-30-18 21<br />
ANR,ANTENNA 21<br />
ANR,CMA4000SM 26<br />
ANR,CMA4500SM-MM 26<br />
ANR,CMA5000SM-45 26<br />
ANR,ME538M 27<br />
ANR,MS2711A 16<br />
ANR,MS2711D 16<br />
ANR,MS2711D-31-25 16<br />
ANR,MS2721A 16<br />
ANR,MT9083B 27<br />
ANR,S331D 16<br />
ANR,S331E 18<br />
ANR,S332D 18<br />
ANR,S332E 18<br />
ANR,S332E-CMAP-MOD 18<br />
ANR,S820A 18<br />
ANR,S820D 18<br />
ANR,WAVEGUIDE-ADAP<br />
TELEWAVE<br />
18<br />
ANT,DIRECTIONAL YAGI 21<br />
VARIOUS MANUFACTURERS<br />
ANT,OMNIDIRECTIONAL<br />
APP-TEK<br />
21<br />
APT,ODA6000CP<br />
AQUA<br />
70<br />
AQU,SNAKEEYE3<br />
ARCHOS<br />
67<br />
ARC,AV500<br />
ARL<br />
68<br />
ARL,EL-315 72<br />
ARL,EL-316 72<br />
ARL,NGARA<br />
ATLAS<br />
72<br />
ATL,TCS-60<br />
AVE<br />
61<br />
AVE,VSIPLUS<br />
AVO<br />
78<br />
AVO,PENTA-PLUS-DMM<br />
BARFIELD<br />
29<br />
BAR,1811KIT<br />
BARLO<br />
48<br />
BAR,MTC-150 60<br />
BAR,STC-10000 60<br />
BAR,STC-25000 60<br />
BAR,STC-5000 60<br />
BAR,STC-500NATA<br />
BAUR<br />
61<br />
BAU,DPA75<br />
BEAMEX<br />
39<br />
BEA,BIC200 48<br />
BEA,MC5 48<br />
BEA,MC5-IS 48<br />
BEA,PUMPS<br />
BEHLMAN<br />
48<br />
BEH,BL1350C-2<br />
FW BELL (USA)<br />
43<br />
BEL,4190 13<br />
BEL,5180<br />
BIDDLE<br />
13<br />
BID,550005<br />
BIRD<br />
40<br />
BIR,43 19<br />
BIR,8080 21<br />
BIR,ELEMENT-HF 19<br />
BIR,ELEMENT-LF<br />
BRUEL & KJAER<br />
19<br />
BK,2237A 72<br />
BK,2238E-NATA 73<br />
BK,2238NMT-KIT 73<br />
BK,2239A-NATA 73<br />
BK,7815 73<br />
BK,8202<br />
BLASTRONICS<br />
62<br />
BLA,UMX-SM-6<br />
BRISTOL<br />
62<br />
BRI,10000-NATA<br />
HONEYWELL LIFE SAFETY<br />
55<br />
BW,BUMP 71<br />
BW,GA-SPAK 71<br />
BW,MICROCLIP 71<br />
CABLE DETECTION<br />
CAB,EZIDIG<br />
DVMR<br />
66<br />
CAM,DVMR-4C<br />
CASIO<br />
78<br />
CAS,EX-F1<br />
CASELLA CEL<br />
47<br />
CAS,MICROTHERM<br />
CATU<br />
72<br />
CAT,CL-8-36 PH STICK<br />
CCI<br />
30<br />
CCI,POWER-MATE 15A<br />
CHAUVIN ARNOUX<br />
32<br />
CHA,PROBE-I<br />
GRIDSENSE<br />
9<br />
CHK,CK1 36<br />
CHK,CK5 36<br />
CHK,CR100 36<br />
CHK,CR500 36<br />
CHK,CT1000L 36<br />
CHK,CT3000L 36<br />
CHK,LM05 31<br />
CHK,PM20 32<br />
CHK,PM30 32<br />
CHK,PM30PLUS 32<br />
CHK,PM35 34<br />
CHK,PM40PQA 34<br />
CHK,PM45<br />
CHLORIDE POWERLAND<br />
34<br />
CHL,ACTIVE3000<br />
CHROMA<br />
43<br />
CHR,61501 PAC-PS 43<br />
COM-POWER CORPORATION<br />
COM,AH-118<br />
SANDISK CORPORATION<br />
21<br />
COM,FLASH512MB 52<br />
COM,FLASH64MB<br />
CRYSTAL ENGINEERING<br />
CORPORATON<br />
53<br />
CRY,NVISION-30-NATA 48<br />
CRY,XP21-100-NATA 55<br />
CRY,XP21-10K-NATA 56<br />
CRY,XP21-300-NATA 56<br />
CRY,XP21-3K-NATA 56<br />
CRY,XP2I-1K-NATA 56<br />
CSCOPE INTERNATIONAL LTD<br />
CSC,CATXDSGA-KIT 67<br />
CSC,CATXDSGV-KIT 29<br />
CSC,CATXDSGV-KIT 67<br />
CSS,COLT4<br />
DATATAKER<br />
64<br />
DE,CANGATE 53<br />
DE,DT600 53<br />
DE,DT80 53<br />
DE,DT800 54<br />
DE,DT80M 54<br />
DE,DT85<br />
DEFELSKO<br />
54<br />
DEF,FNS2 58<br />
DEF,POS-200ADV 58<br />
DEF,POSITEST<br />
DETEC<br />
58<br />
DET,DH-50-KIT4<br />
DILLION<br />
78<br />
5<br />
DIL,ED2000-5K<br />
DKK<br />
61<br />
DKK,RC-24P-DP<br />
DIGITAL LIGHTWAVE<br />
74<br />
DLW,NICPLUS10G<br />
DRANETZ-BMI<br />
23<br />
DRA-BMI,CAF-ETHERNET 36<br />
DRA-BMI,DVMDS 37<br />
DRA-BMI,PG4400 34<br />
DRA-BMI,PR1500 37<br />
DRA-BMI,PR6035A/36 37<br />
DRA-BMI,PX5 34<br />
DRA-BMI,TR2021 37<br />
DRA-BMI,TR2501 37<br />
DRA-BMI,TR2510<br />
DRUCK<br />
37<br />
DRU,DPI603-2 49<br />
DRU,DPI603-20 49<br />
DRU,DPI610-2 49<br />
DRU,DPI610-20IS 49<br />
DRU,DPI610-20-NATA 49<br />
DRU,DPI610-2-NATA 49<br />
DRU,DPI610-400 49<br />
DRU,DPI610-400-NATA 49<br />
DRU,DPI615-20-NATA 49<br />
DRU,DPI620-AMC 49<br />
DRU,DPI705 64<br />
DRU,DPI705-IS 64<br />
DRU,PTX1400-25 55<br />
DRU,PTX1400-4 55<br />
DRU,PTX1400-40 55<br />
DRU,PTX1400-600 55<br />
DRU,PV411A 49<br />
DRU,UPS III-IS<br />
EBRO<br />
49<br />
EBR,EBI125A-BD-3<br />
ELCOMETER<br />
54<br />
ELC,331-B 65<br />
ELC,331-SH<br />
ELGAR<br />
66<br />
ELG,501<br />
EMERSON<br />
43<br />
EME,375 49<br />
EME,475<br />
ENI<br />
49<br />
ENI,604L<br />
ENVIRODATA<br />
19<br />
ENV,DL20WSD 76<br />
ENV,WM20<br />
ETM<br />
76<br />
ETM,9900<br />
EXCALIBER<br />
54<br />
EXA,1000<br />
EXFO<br />
78<br />
EXF,AXS-850 22<br />
EXF,PPM352_FIP400 25<br />
EXFO,ETS-1000L 22<br />
EXFO,FTB-860G 22<br />
EXFO,PPM350B<br />
FERGUSON<br />
24<br />
FER,115-2000<br />
FIBREOPTIC<br />
43<br />
FIB,LAUNCH MM 50UM 27<br />
FIB,LAUNCH MM 62.5UM 27<br />
<br />
FIB,LAUNCH SM 9UM 27<br />
FIB,MTFS15-1000<br />
FITEL<br />
46<br />
FIT,S123M12 25<br />
FIT,S178_S325 26<br />
FIT,S325A 26<br />
FIT,SPLICER-CLEAVER<br />
FIXTURELASER<br />
26<br />
FIX,DIRIGO 48<br />
FIX,PAT<br />
FLEXIM<br />
48<br />
FLE,G608<br />
FLIR SYSTEMS<br />
56<br />
FLI,E60 45<br />
FLI,I60 45<br />
FLI,T400 45<br />
FLOYD INSTRUMENTS PTY LTD<br />
FLO,PG 0-160BAR 56<br />
FLO,PG 0-250BAR<br />
FLUKE<br />
56<br />
FLU,1587 38<br />
FLU,1623-KIT 31<br />
FLU,1625-KIT 31<br />
FLU,1630-EARTH CLAMP 31<br />
FLU,1653 38<br />
FLU,177 8<br />
FLU,199C-SCOPEMETER 8<br />
FLU,2042 29<br />
FLU,289 8<br />
FLU,376 37<br />
FLU,481 74<br />
FLU,52-2 44<br />
FLU,54-2 44<br />
FLU,54-2FLUKEVIEW 44<br />
FLU,5500A-NATA 12<br />
FLU,576 44<br />
FLU,700P08-70BAR 49<br />
FLU,700P31-690BAR 50<br />
FLU,700PD6-7BAR 50<br />
FLU,700S/W-DPC-TRACK 50<br />
FLU,718-300G 50<br />
FLU,719-100G 50<br />
FLU,719-30G 50<br />
FLU,725 50<br />
FLU,725-NATA 50<br />
FLU,743B 50<br />
FLU,744 50<br />
FLU,773 50<br />
FLU,789 PROCESSMETER 50<br />
FLU,80K-40 9<br />
FLU,80TK 44<br />
FLU,810 62<br />
FLU,87-5 8<br />
FLU,990DSL 2/2+ 24<br />
FLU,DTX1800 22<br />
FLU,DTX-MFM2 22<br />
FLU,DTX-OTDR 22<br />
FLU,DTX-PLA 22<br />
FLU,DTX-SFM2 22<br />
FLU,DTX-TERA KIT 22<br />
FLU,EI-162BN 31<br />
FLU,ETHERSCOPE-EX 22<br />
FLU,FT650 27<br />
FLU,FTK1000 25
FLU,FTK150 25<br />
FLU,I1010AC/DC CLAMP 37<br />
FLU,I410 AC/DC CLAMP 37<br />
FLU,LS-13101550 25<br />
FLU,OPTIFIBER-MM 27<br />
FLU,OPTIFIBER-SM 27<br />
FLU,OPTIFIBER-SM-MOD 27<br />
FLU,OPTIVIEW-GIG 22<br />
FLU,PROB-TEMP-26 44<br />
FLU,PV350 55<br />
FLU,Ti25 45<br />
FLU,Ti32 45<br />
FLU,Ti32_TELEPHOTO 45<br />
FLU,Ti32_WIDE-ANGLE 46<br />
FLU,TiR32 46<br />
FLU,VR1710<br />
FOUIER SYSTEMS<br />
34<br />
FOU,DAQPRO-2 54<br />
FOU,MICROLOG-KIT<br />
FUJIKURA<br />
54<br />
FUJ,FSM60S-CT30<br />
GARRETT<br />
26<br />
GAR,CS5000<br />
GLOBAL WATER<br />
78<br />
GLO,FP101<br />
NETTEST<br />
76<br />
GNE,WINPHARAOH2 WAN 23<br />
GENRAD<br />
GR,1433-20 12<br />
GR,1433B-NATA 12<br />
GR,1433F-NATA<br />
GRANT<br />
12<br />
GRA,W6-NATA<br />
GUTERMANN<br />
51<br />
GUT,AQUASCOPE3<br />
HALOTEK<br />
67<br />
HAL,78000<br />
HALSTRUP WALCHER<br />
70<br />
HAL,KAL84<br />
HART<br />
50<br />
HAR,1521-NATA 44<br />
HAR,1523-NATA 44<br />
HAR,9107-NATA 51<br />
HAR,9141 51<br />
HAR,9141-NATA 51<br />
HAR,9150 51<br />
HAR,9170-R-NATA<br />
HEINE TECHNO<br />
51<br />
HEI,TECHNO-6X320<br />
HILTI<br />
47<br />
HIL,FERROSCAN 66<br />
HIL,PD38 68<br />
HIL,PS20 66<br />
HIL,PS200 FERROSCAN 66<br />
HIL,TESTER4<br />
HIOKI<br />
60<br />
HIO,2332-20RPMS 34<br />
HIO,3169-21 CT500AMP 34<br />
HIO,3169-21CLAMPONPT 35<br />
HIO,3169-21CT1000AMP 35<br />
HIO,3196-PQA 35<br />
HIO,3196PQA-CT1000 35<br />
HIO,3197PQA 35<br />
HIO,3283 CLAMP ON-LT 30<br />
HIO,3284 37<br />
HIO,3285 37<br />
HIO,3290 37<br />
HIO,332 POWERTESTER 36<br />
HIO,3404 47<br />
HIO,3423 76<br />
HIO,3454-51-3 39<br />
HIO,3455HVIT-5KV 39<br />
HIO,3551BATTERYTEST 43<br />
HIO,3641-20 54<br />
HIO,3641-20-KIT 54<br />
HIO,8421-01 54<br />
HIO,8421-51 54<br />
HIO,8422-51 55<br />
HIO,8826-32CRECORDER 52<br />
HIO,8835 52<br />
HIO,8835-01 52<br />
HIO,8835-HD520 52<br />
HIO,8841 52<br />
HIO,8842 52<br />
HIO,8860 52<br />
HIO,8870-20 53<br />
HIO,8938 53<br />
HIO,9132 36<br />
HIO,9305 53<br />
HIO,9306 53<br />
HIO,9320 53<br />
HIO,9321 53<br />
HIO,9322-KIT 55<br />
HIO,9335 53<br />
HIO,9660CT100A 37<br />
HIO,9661 CCT-500A 38<br />
HIO,9661-01 CCT-500A 38<br />
HIO,9667-FCT-5000A 38<br />
HIO,9669-CCT-1000A 38<br />
HIO,9670 Printer 38<br />
HIO,9694CT5A 38<br />
HIO,9725 53<br />
HIO,LCR 3532-50<br />
HIGH VOLTAGE INC<br />
10<br />
HIV,PFT303 39<br />
HIV,PFT503 39<br />
HIV,VLF6022 39<br />
HIV,VLF90 39<br />
HIRST MAGNETIC INSTRUMENTS<br />
HMI,GM04<br />
HOLADAY<br />
13<br />
HOL,HI-3002 13<br />
HOL,HI-3004 13<br />
HOL,HI-3604 13<br />
HOL,HI-3627<br />
HORIBA<br />
13<br />
HOR,U-52-10M<br />
HOUSTON<br />
74<br />
HOU,1850-40<br />
HEWLETT-PACKARD<br />
(Also see Agilent)<br />
60<br />
HP,1662A 12<br />
HP,33120A 10<br />
HP,33220A 10<br />
HP,33250A 10<br />
HP,34401A 8<br />
HP,35670A 12<br />
HP,53181A 14<br />
HP,5350A 14<br />
HP,5352B 14<br />
HP,7475A-I 9<br />
HP,83623B 14<br />
HP,8449B 19<br />
HP,8481B 19<br />
HP,8494/5B 21<br />
HP,8494B 19<br />
HP,8494B-8495B 19<br />
HP,8495B 21<br />
HP,8495D 21<br />
HP,8593E 16<br />
HP,8648C 14<br />
HP,8648D 14<br />
HP,8753D 18<br />
HP,8757D 18<br />
HP,8903B 18<br />
HP,8920A 18<br />
HP,E4407B 16<br />
HP,E4418B-001 19<br />
HP,E9300A 19<br />
HP,E9300B 19<br />
HP,E9300H 19<br />
HP,ESG-D4000A 14<br />
HEALTH PHYSICS INSTRUMENTS<br />
HPI,CYPHER5000<br />
HV DIAGNOSTICS<br />
74<br />
HVD,HVA TD60 40<br />
HVD,HVA30-DC/VLF 40<br />
HVD,HVA60-DC/VLF<br />
HYDROLAB<br />
40<br />
HYD,MS5<br />
HYDRAMOTION LTD UK<br />
74<br />
HYL,V700S-21<br />
HYDROLOGICAL SERVICES<br />
77<br />
HYS,OSSB1<br />
ICC<br />
76<br />
ICC,LD400 67<br />
ICC,LD408<br />
ICETECH<br />
67<br />
ICE,LV48<br />
INTERNATIONAL LIGHT<br />
12<br />
ILI,1400ABC<br />
INVENSYS<br />
76<br />
INV,MPS48DC2400W<br />
ION SCIENCE<br />
10<br />
ION,GASCHECK3000 70<br />
ION,GASCHECKG3<br />
ISC<br />
70<br />
ISC,MDU420<br />
ISCO<br />
70<br />
ISCO,6712 74<br />
ISK,6700-730<br />
IVIE<br />
74<br />
IVI,IE35-2P<br />
JDSU<br />
73<br />
JDSU,ANT20 24<br />
JDSU,ANT5-STM4 23<br />
JDSU,CSC-ETHTR-P2 24<br />
JDSU,EDT-135 24<br />
JDSU,FIBER_INSPECT 27<br />
JDSU,MTS8000 STM-64 24<br />
JDSU,MTS8000-ODM 27<br />
JDSU,OLS-55 25<br />
6<br />
JDSU,OLS-OLP 35 25<br />
JDSU,SMARTCLASS<br />
JOFFRA<br />
24<br />
JOF,C650 51<br />
JOF,C650 51<br />
JOF,DPC-1000-NATA<br />
JACOBS RADIO<br />
50<br />
JRC,NJJ-95B<br />
KELLER-DRUCK<br />
66<br />
KEL,MANORECORD<br />
KYORITSU ELECTRIC<br />
56<br />
KIK,PLZ1002W<br />
KINGFISHER<br />
10<br />
KIN,KI73410_LTS 25<br />
KIN,KI78010-7600 25<br />
KIN,KI7822B-7600A 25<br />
KIN,KI7827-7600 25<br />
KRAUTKRAMER GMBH & CO<br />
KRA,DMS 58<br />
KRA,DYNAPOCKET<br />
KURZ<br />
58<br />
KUR,2443-24<br />
LABEC<br />
64<br />
LAB,OTWMD18<br />
LAPLACE<br />
57<br />
LAP,SA1000<br />
LEICA<br />
13<br />
LEI,DISTOPRO<br />
LEM<br />
68<br />
LEM,CURRENT PROBE10A 38<br />
LEM,LEM-FLEXII 38<br />
LEM,TOPAS1000 36<br />
LEM,UNIGOR355<br />
LINEAR<br />
8<br />
LIN,LSPC-1<br />
LION<br />
62<br />
LIO,SD-400P 71<br />
MADGE TECH INCORPORATION<br />
MAD,ULTRASHOCK-EB<br />
MARCONI<br />
62<br />
MAR,2945 18<br />
MAR,6910 19<br />
MAR,6912 19<br />
MAR,6913 19<br />
MAR,6920 19<br />
MAR,6923 19<br />
MAR,6970 19<br />
MAR,ARGUS2<br />
RS COMPONENTS LTD<br />
46<br />
MAR,PSCI424-585<br />
MECMESIN<br />
30<br />
MEC,AFG-1000N 60<br />
MEC,AFG-1000NALC 60<br />
MEC,TW60<br />
MEGGER<br />
60<br />
MEG,10-01-10KV 39<br />
MEG,BM21 39<br />
MEG,DET2/2 31<br />
MEG,DET20C 31<br />
MEG,DET4TC2 31<br />
MEG,DLRO10 31<br />
MEG,DLRO-100LEAD 32<br />
MEG,DLRO10X 31<br />
MEG,DLRO200 32<br />
MEG,DLRO600 32<br />
MEG,DLRO-LEADSET 32<br />
MEG,FT6/12 39<br />
MEG,LT330 EN-AU 32<br />
MEG,LTW335-FLIT 30<br />
MEG,MIT1020-10KV DIT 39<br />
MEG,MMC850CLAMPMETER 36<br />
MEG,MPP1002-FAULT PP 29<br />
MEG,MPRT8430-BAS-3CH 42<br />
MEG,RCDT330 30<br />
MEG,S1-1052 10KVDIT 39<br />
MEG,S1-552 5KVDIT 39<br />
MEG,SK-MDP3 36<br />
MEG,TDR1000 29<br />
MEG,TDR2000/2RM 29<br />
MEG,TTR320-47<br />
MEL<br />
40<br />
MEL,M5-200<br />
METTLER<br />
60<br />
MET,15KG 61<br />
MET,60KG 61<br />
MET,PB8001<br />
METREL<br />
61<br />
MET,IT3017INSTALTEST 30<br />
MET,MI2121AUS<br />
METRIX<br />
30<br />
MET,MX2040 36<br />
MET,MX51EX<br />
METROSONICS<br />
8<br />
MET,PF-1-F<br />
MINOLTA<br />
36<br />
MIN,CL-200<br />
MINELAB<br />
76<br />
MIN,EX-1000 78<br />
MIN,X-TERRA-705<br />
MITUTOYO CORPORATION<br />
78<br />
MIT,500-172 60<br />
MIT,SJ201-NATA<br />
MONARCH INSTRUMENTS<br />
58<br />
MON,PALMSTROBE 47<br />
MON,PHASER 47<br />
MON,PLT200-KIT<br />
MORITEX<br />
47<br />
MOR,PALMSCOPE<br />
MULTIAMP<br />
47<br />
MUL,MS-2<br />
NARDA<br />
42<br />
NAR,8217 74<br />
NAR,8616 13<br />
NAR,NBM-550<br />
NOVATECH<br />
13<br />
NOV,1637-5 57<br />
NOV,1637-5CGA<br />
NTI AUDIO<br />
57<br />
NTI,NT-DAS<br />
OHAUS<br />
73<br />
OHA,EXP4100<br />
OLDHAM<br />
77<br />
OLD,MX21-SO2 70<br />
OLSON INSTRUMENTS INC<br />
OLS,FTG<br />
OLYMPUS<br />
66<br />
OLY,38DL 58<br />
OLY,IF8C5-30 47
OLY,IPLEX-MX 47<br />
OLY,IPLEX-MXII 47<br />
OLY,IV6C6-20-ZOOM<br />
OMICRON<br />
47<br />
OMI,CMA156-6PCA 42<br />
OMI,CMC256-6 42<br />
OMI,CMGPS 42<br />
OMI,CPC100PTS 40<br />
OMI,C-PROBE1 42<br />
OMI,CPSB1 40<br />
OMI,CP-TD1 40<br />
OMI,FRA<br />
OTT<br />
40<br />
OTT,KL010-150<br />
PANAMETRICS<br />
74<br />
PAN,26MG 58<br />
PAN,C-LP-40NM 56<br />
PAN,C-PT-10HB 56<br />
PAN,GC-RL302 56<br />
PAN,GC-RL319 56<br />
PAN,OKS 56<br />
PAN,PM880 72<br />
PAN,PT878 56<br />
PAN,PT878E 56<br />
PAN,PT878GC-01<br />
PCB<br />
57<br />
PCB,300A20<br />
PCTEL<br />
62<br />
PCT,EX-QUAD 18<br />
PCWI INTERNATIONAL PTY LTD<br />
PCW,DC30 58<br />
PCW,P40-PULSE<br />
PEARPOINT LTD<br />
58<br />
PEA,FLEXI-CAM<br />
ASTRO PRODUCTS<br />
68<br />
PHA,53550<br />
PHENIX TECHNOLOGIES<br />
62<br />
PHE,BK130<br />
PHILIPS<br />
40<br />
PHI,PM6666<br />
PHOTOVAC<br />
14<br />
PHO,2020PRO<br />
PHYNIX GMBH & CO<br />
70<br />
PHY,SURFIX FN<br />
POLYSONICS<br />
60<br />
POL,HYDRA-SX30-2<br />
PPM TECHNOLOGIES<br />
57<br />
PPM,FORM400<br />
PROCEQ<br />
70<br />
PRO,2000-ND 66<br />
PRO,EQUOTIP 58<br />
PRO,PROFOSCOPE 66<br />
PRO,SIL-UN<br />
PROFOUND<br />
66<br />
PRO,VIBRA<br />
PROGRAMMA<br />
62<br />
PRO,EGIL-CB ANALYZER 42<br />
PRO,MAGNUS-2.2KV 42<br />
PRO,SVERKER760 43<br />
PRO,TORKEL-840<br />
PROMAX<br />
43<br />
PRO,PRODIG-5 12<br />
PRO,PROLINK4C-PREM<br />
PROTEK<br />
12<br />
PRO,3290<br />
GE PROTIMETER PLC<br />
16<br />
PRO,MMS-PLUS 66<br />
PRO,SM<br />
PROSCOPE<br />
68<br />
PRO,SCA-12770<br />
PRUFTECHNIK<br />
77<br />
PRU,AL12.116 48<br />
PRU,ROT-PROEX 48<br />
PRU,ROT-ULTRA<br />
QUEST<br />
48<br />
QUE,2400<br />
RADIODETECTION<br />
73<br />
RAD,AFRAME FORRD4000 67<br />
RAD,FLEXISONDE 67<br />
RAD,RD4000TYPE7KIT 67<br />
RAD,RD400PXL 67<br />
RAD,STETH-L<br />
RAE SYSTEMS<br />
29<br />
RAE,MR2000 70<br />
RAE,MR3000<br />
RALSTON<br />
71<br />
RAL,XHGV-350<br />
RAYTEK<br />
51<br />
RAY,MX6<br />
REDLAKE<br />
44<br />
RED,S1000<br />
RION<br />
47<br />
RIO,CP-10 62<br />
RIO,NL-04 73<br />
RIO,NL-05 73<br />
RIO,NL-32RTA 73<br />
RIO,NL-32RTA-NATA 73<br />
RIO,VA-10 62<br />
RIO,VA-11<br />
ROHDE & SCHWARZ<br />
62<br />
RS,FSH3-TG 16<br />
RS,FSH3-TG-V 16<br />
RS,FSH6-TG 16<br />
RS,HL013 21<br />
RS,NRT 19<br />
RS,TYPE 461-313<br />
SE INTERNATIONAL<br />
55<br />
SE,MONITOR 4<br />
SENSOCON<br />
74<br />
SEN,VF01B<br />
SEVERN SCIENCES<br />
64<br />
SEV,TORTUSII<br />
SEWARD<br />
74<br />
SEW,PAC3760 30<br />
SEW,PT-300 30<br />
SEW,TROLLERY-3760PKIT 30<br />
SEW,XE3760PKIT+<br />
SCHAFFNER<br />
31<br />
SFN,438 13<br />
SFN,INA-6502 13<br />
SFN,MODULA 6100<br />
SCHAEVITZ<br />
13<br />
SHA,P1241-10000 55<br />
SHA,P3061-4D<br />
SHORTRIDGE<br />
55<br />
SHO,ADM-860 64<br />
SHO,CFM88-3 64<br />
SI PRESSURE INSTRUMENTS<br />
SI,PC6-20-NATA 51<br />
SI,PC6-35-NATA 51<br />
SI,PC6-40-NATA 51<br />
SI,PC6-700 51<br />
SI,PC6-700-NATA 51<br />
SI,PC6-PRO 350<br />
SKC<br />
51<br />
SKC,224-PCXR4<br />
SMC<br />
71<br />
SMC,PTE-100-C<br />
SOCOMEC<br />
42<br />
SOC,ENT-TW10<br />
SOLINIST<br />
43<br />
SOL,122<br />
SOLMETRIC<br />
74<br />
SOL,SUNEYE210<br />
SONICLEAN<br />
68<br />
SON,2000HT<br />
SORESEN<br />
57<br />
SOR,DCR10-120B 10<br />
SOR,DCS150-20E 10<br />
SOR,DCS60-50<br />
SPIRENT<br />
10<br />
SPI,SMB6000 23<br />
SPI,SPT-2000<br />
STANDFORD RESEARCH<br />
23<br />
SR,SR720<br />
HUBER & SUHNER<br />
10<br />
SUH,SUCOFLEX-104PE<br />
SUNRISE<br />
21<br />
SUN,SUNLITE E1<br />
SVANTEK<br />
24<br />
SVA,912A 62<br />
SVA,SV100 62<br />
T&R TEST EQUIPMENT PTY LTD<br />
T&R,200A3PHEDIT 42<br />
T&R,CIT 42<br />
T&R,DSM200 32<br />
T&R,DVS3-HP 43<br />
T&R,KV30-40 40<br />
T&R,PCU1-SP NLU5000A 42<br />
TOUR & ANDERSON<br />
TA,CBI<br />
TEKTRONIX<br />
65<br />
TEK,AFG3022 10<br />
TEK,AFG3102 10<br />
TEK,P6015 9<br />
TEK,TDS2024B 9<br />
TEK,TDS3052B 9<br />
TEK,TDS3054 9<br />
TEK,TDS3054B 9<br />
TEK,THS730A 9<br />
TEK,TPS2014<br />
TESTO<br />
9<br />
TES,177-H1 55<br />
TES,177-T4 55<br />
TES,300M 57<br />
TES,319 68<br />
TES,335 57<br />
TES,350XL 57<br />
TES,445 64<br />
TES,635-2 72<br />
TES,645-1 72<br />
TES,845 44<br />
7<br />
<br />
TES,880-3 V4<br />
TEXCEL<br />
46<br />
TEX,ATM<br />
TOPCON<br />
62<br />
TOP,BM-9-2 76<br />
TOP,IM-2D-NATA 76<br />
TOP,IM-5-NATA<br />
TORTECH<br />
76<br />
TOR,110-2000<br />
TPS<br />
43<br />
TPS,90FL-T 75<br />
TPS,LOW K PROBE 75<br />
TPS,REDOX 75<br />
TPS,WP-80 75<br />
TPS,WP-80M 75<br />
TPS,WP82 75<br />
TPS,WP-84 75<br />
TPS,WP-88<br />
TR<br />
75<br />
TR,12V-BAT-CIG 10<br />
TR,RF-CABLES 21<br />
TR,RF-CONN<br />
TRAFAG<br />
21<br />
TRA,8204-1D-20A<br />
TRAFFIC PRO<br />
55<br />
TRA,RETAILPACK<br />
KENWOOD<br />
78<br />
TRI,PD35-20<br />
TSI<br />
12<br />
TSI,7565 72<br />
TSI,8324 65<br />
TSI,8345 65<br />
TSI,8373 65<br />
TSI,8375 65<br />
TSI,8386A 65<br />
TSI,8520 71<br />
TSI,8520-1 71<br />
TSI,8525 71<br />
TSI,8530 71<br />
TSI,8530-ENC 71<br />
TSI,8533 71<br />
TSI,8554 72<br />
TSI,8705 65<br />
TSI,8710 65<br />
TSI,9535 65<br />
TSI,9555 65<br />
TSI,AM510<br />
UE SYSTEMS<br />
71<br />
ULT,UP100KT<br />
UNIDATA<br />
67<br />
UNI,6526B-21LCD<br />
UNIMEASURE<br />
76<br />
UNI,P75-3C<br />
UNIVERSAL TECHNIC<br />
38<br />
UNI,P75-3C HYBRID-DP<br />
UPSONIC POWER<br />
38<br />
UPS,BATTERY BANK-7AH<br />
USB<br />
43<br />
USB,232CONVERTER<br />
USRADAR<br />
10<br />
USR,SEEK-SPR<br />
VAISALA<br />
67<br />
VAI,HMP-135Y 55<br />
VAI,HMP-235Y 55<br />
VAI,WAA151<br />
VAN ESSEN<br />
65<br />
VAN,DI502<br />
VARIAC<br />
75<br />
VAR,3000 43<br />
VAR,6500-3<br />
AUSTRALIAN RECTIFIERS<br />
43<br />
VAR,D-283-OB<br />
VEEX<br />
43<br />
VEE,TX130<br />
VEGA<br />
24<br />
VEG,BAR20-1<br />
VERMASON<br />
55<br />
VER,222ES<br />
VIVAX<br />
8<br />
VIV,VCAM-60M 68<br />
VIV,VLOCPRO<br />
WEINSCHELL<br />
67<br />
WEI,23-10-34 21<br />
WEI,33-10-34 21<br />
WEI,34-30-34 21<br />
WEI,46-03-34 21<br />
WEI,46-06-34 21<br />
WEI,46-10-34 21<br />
WEI,46-20-43 21<br />
WEI,82-30-34 21<br />
WEI,AS6 21<br />
WEI,M2-20<br />
WEISS<br />
21<br />
WEI,WKL-100-40 57<br />
NARDA (WANDEL & GOLTERMANN)<br />
WG,ESM-20<br />
WOHLER<br />
74<br />
WOH,VIS2000PRO 68<br />
WOH,VIS250-S CAMERA 68<br />
WOH,VIS340<br />
WYLER<br />
68<br />
WYL,CL45<br />
WYLAM<br />
60<br />
WYL,PORTAPAINT<br />
XANTREX<br />
60<br />
XAN,XFR600-4 12<br />
XAN,XKW60-50<br />
X-RITE<br />
12<br />
XRI,SP60<br />
YOKOGAWA<br />
77<br />
YEW,3057-22 52<br />
YEW,3712-31 52<br />
YEW,3712-41 52<br />
YEW,3750 52<br />
YEW,51001-NATA 76<br />
YEW,DR130 52
ELECTRONICS<br />
Multimeters & Electrometers<br />
Digital Storage Oscilloscopes<br />
Probes & Accessories<br />
Function Generators<br />
LCR Meters<br />
DC <strong>Power</strong> Supplies & Loads<br />
Spectrum <strong>Analysers</strong> - Low Frequency<br />
TV Test Equipment<br />
Laboratory Calibrators<br />
Logic <strong>Analysers</strong>/PROM Programmers<br />
Gauss/Tesla Meters<br />
E & H Field Strength Meters<br />
EMC & <strong>Power</strong> Disturbance Simulators<br />
Multimeters & ElectrometersTe<br />
See also Electrical Testers on page 29-30<br />
Fluke 87-5 Industrial True-RMS Multimeter with Thermometer<br />
FLU,87-5 MY<br />
Unique function for accurate voltage and frequency measurements<br />
on adjustable speed. True-RMS AC voltage and current for accurate<br />
measurements on non linear signals. Built in thermometer. Measure up<br />
to 1,000VAC and DC. Measure up to 10A (20A for 30 seconds). 10,000uF<br />
capacitance range. Frequency to 200kHz and % duty cycle. Peak capture<br />
<br />
Fluke Multimeter with Backlight<br />
FLU,177 (1209) AU<br />
General purpose multimeter 0.09% basic accuracy.<br />
True RMS voltage & current measurements,<br />
digital display with analog bargraph & backlight,<br />
manual & automatic ranging, display Hold & Auto<br />
Hold, frequency & capacitance measurements.<br />
Overvoltage category EN61010-1 CAT III 1000V/<br />
CAT IV 600V.<br />
Fluke 289 True-RMS Industrial Logging<br />
Multimeter with TrendCapture<br />
FLU,289 (1208) AU<br />
<br />
dot matrix display. 0.025% Basic DC accuracy. CAT<br />
III 1000 V/CAT IV 600V safety rated.<br />
Agilent/HP 34401A Digital Multimeter<br />
<br />
<br />
<br />
<br />
functions including limits test. 512 point storage. RS232 & HPIB interfaces.<br />
8<br />
www.techrentals.com.au<br />
Multimeters & Electrometers cont’d.<br />
LEM Unigor 355 Hand-held Digital Multimeter/Signal<br />
Generator<br />
<br />
Measures DC, AC true RMS voltage & current, resistance,<br />
f<br />
<br />
voltage 300mV to 1kV, current 300μA to 10A, resistance<br />
<br />
temperature ºC/ºF, Pt 100 -200 to 100ºC, Pt 1000 100<br />
to 850ºC. Features automatic socket shutters, IR interface, split second<br />
chronograph, automatic measurement value storage, etc.<br />
Metrix MX51EX Intrinsically Safe Digital Multimeter<br />
<br />
Resolution 5,000 count with 0.1% basic accuracy. Measures AC/DC<br />
voltage & current, & resistance. Voltage sensitivity 100μV. Max voltage<br />
1kVDC, 750VAC. Max current 10A. Intrinsic safety limits of 60V & 500mA.<br />
Vermason 222541 Electrostatic Meter<br />
<br />
Electrostatic meter for periodic audits of facilities,<br />
monitoring packaging, materials, machines and other<br />
electrostatic generative equipment or processes. This<br />
precision field meter is designed to measure electrostatic<br />
voltage potentials over selected distances from 1 to 20cm.<br />
Range at the standard distance of 2cm is 20kV. Two range<br />
3 digit display in V or kV.<br />
Digital Storage Oscilloscopes<br />
Agilent MSOX3024A 200MHz<br />
Scope 4+16Ch with Logic<br />
Analyser<br />
<br />
<br />
<br />
update rate. Search and navigate capability. Integrated time-aligned digital<br />
and analog signal viewing. USB storage, LAN operability.<br />
Agilent MSO6104A 1GHz Digital Oscilloscope<br />
with Logic<br />
<br />
<br />
<br />
100,000 waveforms/s with 256 levels intensity.<br />
<br />
counter function. Triggering includes video, HDTV, I2C, SPI, LIN, CAN, &<br />
USB. FFT analysis included. LAN, USB, GPIB, & XGA interfaces standard.<br />
Fluke 199C Scopemeter 200MHz Hand-held<br />
FLU,199C-SCOPEMETER (1361) AU<br />
200MHz bandwidth 2 channel colour digital oscilloscope<br />
<br />
persistence feature. 2.5GS/s real time sampling. Input<br />
sensitivity 5mV/div to 100V/div. Glitch capture 3ns using<br />
pulse width triggering. Timebase range in scope mode<br />
5ns/div to 2min/div. Trigger types auto, free run, single<br />
shot, edge, delay, video, video line, selectable pulse<br />
width and external. Automatic capture and replay of last<br />
100 screens. Measures electrical power properties such<br />
as VA VAR, etc. Isolated inputs.
www.techrentals.com.au<br />
Digital Storage Oscilloscopes cont’d.<br />
Tektronix TDS2024B 200MHz Digital<br />
Oscilloscope<br />
<br />
<br />
storage oscilloscope. 2GS/s sampling rate.<br />
Sensitivity 2mV to 5V/div. Automatic waveform<br />
measurements. Includes FFT analysis as<br />
standard. Removable data storage via front<br />
panel USB port.<br />
Tektronix TDS3052B 2 Channel<br />
500MHz DSO<br />
<br />
Sampling rate 5GS/s. Memory length 10k.<br />
Sensitivity 1mV to 10V/div. Time base 1ns<br />
to 10s/div. Trigger functions include video.<br />
Automatic waveform measurements. FFT<br />
Analysis. Wave alert & e-scope web based control. Colour LCD with digital<br />
<br />
interfaces. In-built FDD.<br />
Tektronix TDS3054B 500MHz 4 Channel DSO<br />
<br />
<br />
Sampling rate 5GS/s. Memory length 10k. Sensitivity 1mV to 10v/div. Time<br />
base 1ns to 10s/div. Trigger functions include video. Extensive automatic<br />
waveform measurements. Including FFT, TV trigger, advanced analysis<br />
(TDS3AAM), and limit testing (TDS3LIM). Battery operation.<br />
Tektronix THS730A 200MHz Battery DSO<br />
TEK,THS730A (1360) AU/MY<br />
Dual channel battery portable 200MHz digital storage<br />
oscilloscope with digital multimeter facilities. Maximum<br />
RMS,<br />
maximum float 600V RMS. Waveform processing<br />
includes watts calculations. Video trigger. RS232<br />
interface.<br />
TRAINING FROM TECHRENTALS<br />
9<br />
Digital Storage Oscilloscopes cont’d.<br />
Tektronix TPS2014 100MHz 4 Channel<br />
<strong>Power</strong>scope<br />
<br />
<br />
isolated for floating measurements.<br />
Sensitivity 2mV to 5V/div. Measurements<br />
for current and voltage distortion and their spectral content, harmonics,<br />
instantaneous power, power factor and switching loss. Automatic waveform<br />
measurements. FFT, power analysis, low & high voltage power probes<br />
(P5120). Battery operation.<br />
Probes and Accessories<br />
ELECTRONICS<br />
Chauvin Arnoux Current Probe E3N 0 to 100 Amp<br />
<br />
Current probe for oscilloscopes which uses a Hall effect cell for the<br />
measurement of DC or AC current. Measures currents from 50mA to<br />
100A peak. A thumbwheel can be used to reset zero for adaption to the<br />
measurement environment. The clamp can be used with any measurement<br />
instrument which has a BNC input and an impedance of 1M,
ELECTRONICS<br />
Probes and Accessories cont’d.<br />
USB to RS232 Converter<br />
<br />
USB to RS-232 seriel converter with FTDI chip technology. For converting<br />
legacy peripherals to Universal Serial Bus (USB). Connects to a computer<br />
via the USB port and provides 1 high speed RS-232 serial port. Suitable for<br />
Windows 98, 2000, server 2003, XP, ME, CE, MAC-OS8, OS9, OSX and<br />
<br />
Function Generators<br />
See also RF Signal & Sweep Generators on page 14<br />
Agilent/HP 33120A 15MHz Function/Arbitrary Generator<br />
HP,33120A MY<br />
Function/Arbitrary Waveform Generator. Frequency 15MHz sine and square<br />
waveforms, and 100kHz triangle and ramp waveforms. Gaussian noise<br />
to 10MHz. Output into 50ohms 50mV to 10VP-P. AM, FM, FSK, and burst<br />
modulation. HP-IB and RS-232C interfaces both standard.<br />
Agilent/HP 33220A 20MHz Function/<br />
Arbitrary Generator<br />
HP,33220A (1613) AU<br />
Frequency range 20MHz sine & square<br />
waveforms, 200kHz pulse, triangle, ramp,<br />
noise, & DC waveforms. Gaussian noise to<br />
<br />
Includes option 001 external timebase reference. With optional Benchlink<br />
software waveforms can be captured & played back. HPIB, USB, & LAN<br />
interfaces.<br />
Agilent/HP 33250A 80MHz Function/<br />
Arbitrary Waveform Generator<br />
HP,33250A (1618) AU<br />
Frequency range 80MHz sine & square<br />
waveforms. 50MHz pulse waveforms with<br />
variable rise/fall times. 25MHz arbitrary<br />
waveforms, 1MHz triangle & ramp waveforms. White noise to 50MHz. Output<br />
<br />
software for programming arbitrary waveforms. HPIB & RS232C interfaces.<br />
Tektronix 3022/25MHz<br />
ArbitraryFunction Generator<br />
TEK,AFG3022 (1620) AU<br />
Dual channel function/arbitrary waveform<br />
generator. Frequency range 1mHz to<br />
25MHz sine, 12.5MHz square & pulse<br />
waveforms, 250kHz triangle, ramp, noise & DC waveforms. Arbitrary<br />
<br />
10mV to 10V P-P. AM, FM, FSK, & burst modulation. HPIB, USB, & LAN<br />
interfaces used with included software allows waveforms to be created on<br />
PC & imported into unit. Full screen display also allows display & editing of<br />
waveforms on unit itself.<br />
Tektronix 3102/100MHz<br />
Arbitrary Function Generator<br />
<br />
Dual channel function/arbitrary waveform<br />
generator. Frequency range 1mHz to 100MHz<br />
sine, 50MHz square and pulse waveforms, 1MHz triangle, ramp, noise, and<br />
DC waveforms. 50MHz Arbitrary waveform generation. Gaussian noise<br />
<br />
modulation. HPIB, USB, and LAN interfaces used with included software<br />
allows waveforms to be created on PC and imported into unit. Full screen<br />
display also allows display and editing of waveforms on unit itself.<br />
10<br />
LCR Meters<br />
Hioki 3532-50 5MHz LCR<br />
Meter<br />
HIO,LCR 3532-50 (1290) AU<br />
<br />
speed measurements. Basic accuracy of<br />
±0.08%. Memory for 30 sets of measurement<br />
conditions, including comparator values. Includes correlation correction<br />
function, interactive touch panel operation and enlarged display function.<br />
Applications include laboratory use for evaluation of operating characteristics,<br />
production line use or R&D. Measurement data captured by a personal<br />
computer can be displayed graphically by using standard spreadsheet<br />
software.<br />
Stanford Research SR720 LCR Bridge<br />
SR,SR720 (1297) AU<br />
<br />
inductance 0.0001μH to 99,999H; capacitance 0.0001pF<br />
<br />
frequencies 100/120Hz, 1/10/100kHz. Indicates value, deviation, % deviation,<br />
<br />
optional Kelvin leads.<br />
DC <strong>Power</strong> Supplies & Loads<br />
www.techrentals.com.au<br />
Invensys Intergy Mini <strong>Power</strong> System<br />
48VDC 2.4kW Supply<br />
<br />
Sub-rack mini system 19” rack mount<br />
range. For low power telecommunications<br />
applications (premises data networks &<br />
IP routers, local loop transmission systems & wireless) requiring flexible DC<br />
power supplies. Includes integral DC distribution panel and SM30 Series<br />
Intergy Supervisory Module. All system settings are fully adjustable in<br />
<br />
<br />
Kikisui PLZ1002W Electronic Load<br />
KIK,PLZ1002W (8120) AU<br />
Voltage range 3 to 110V. Current range 0 to 200A. In-built oscillator provides<br />
for dynamic load testing by switching between two different load levels. Load<br />
current may be remotely controlled by voltage or resistance signals. Multiple<br />
units may be operated in parallel. In-built digital volt/current meter. For DC<br />
inputs only.<br />
<br />
<strong>Power</strong> Supply<br />
SOR,DCS150-20E (8113) AU<br />
0-150V, 20A, 3KW. Applications<br />
range from manufacturing test and burn-in of automotive components,<br />
avionics electronics, telecommunications and consumer products to beam<br />
steering, process control, laboratory R&D use. Remote control via LAN or<br />
RS232.<br />
Sorensen DCR10-120B DC <strong>Power</strong> Supply<br />
SOR,DCR10-120B MY<br />
0 to 10V, 0 to 120A.<br />
<br />
<br />
<br />
<br />
TR Built 12V Battery Supply with Cigarette <strong>Power</strong> Connector<br />
TR,12V-BAT-CIG (8160) AU<br />
12V 20AH battery pack with built-in charger. Has cigarette outlet and banana<br />
plug connectors.
www.techrentals.com.au<br />
11<br />
SETUP AND DOWNLOAD<br />
Save your time and reduce your costs by using our data management services. Learning<br />
to operate unfamiliar equipment costs you time and can lead to fundamental errors<br />
in data capture processing. There is a better solution - our setup and download service.<br />
Our technical staff are equipped and trained to deliver you the downloaded data in a range of<br />
suitable output formats including USB drive, CD-ROM, printout, chart and DVD according to your<br />
need and the product’s functionality.<br />
When you nominate your output preferences and appropriate technical information, the rest is taken care of.<br />
<br />
The equipment marked with ‘S’ symbol is available to rent with this service. Fees vary depending on the<br />
complexity of operation and the level of detail involved.<br />
Data management services are available for many products. Below are some examples of what you can expect.<br />
SEWARD ProTag Optima 300<br />
(SEW,PT-300)<br />
FLUKE DTX1800<br />
(FLU,DTX1800)<br />
Setup:<br />
<br />
<br />
Results Downloaded:<br />
<br />
format<br />
<br />
software including database for<br />
end customer<br />
Setup:<br />
<br />
<br />
<br />
<br />
<br />
Results Downloaded:<br />
<br />
<br />
<br />
FLUKE Ti25 Thermal Camera<br />
(FLU,TI25)<br />
Results Downloaded:<br />
<br />
<br />
<br />
<br />
CHK PM30/ PM30PLUS - 3CTs<br />
[Note: Max current is 1000A for PM30]<br />
CHK PM40/ PM45 - 4CTs<br />
(CHK,PM30)<br />
FOURIER DAQPRO<br />
(FOU,DAQPRO-2)<br />
Setup:<br />
<br />
<br />
<br />
<br />
<br />
<br />
(Sag,Swell,Transient)<br />
<br />
Results Downloaded:<br />
<br />
<br />
<br />
<br />
<br />
<br />
Setup:<br />
<br />
measured (Out of 8 channels)<br />
<br />
eg Voltage - Current etc<br />
<br />
<br />
logging interval<br />
<br />
Results Downloaded:<br />
<br />
viewing software<br />
and editing
ELECTRONICS<br />
DC <strong>Power</strong> Supplies & Loads cont’d.<br />
Trio PD35-20 DC <strong>Power</strong> Supply<br />
TRI,PD35-20 (8109) AU<br />
Output 0 to 35V, 0 to 20A. Constant current, constant voltage. Multiple<br />
parallel or series operation. Remote programming of voltage or current by<br />
external voltage or resistance.<br />
Xantrex XFR 600-4<br />
<strong>Power</strong> Supply<br />
<br />
2.8kW programmable DC power<br />
<br />
Xantrek XKW60-50 60V 50A DC <strong>Power</strong> Supply<br />
XAN,XKW60-50 (8115) AU<br />
3 KW DC power supply, 0-60V, 0-50A. Constant current & constant voltage.<br />
Isolated analogue programming. Operation of multiple units in series or<br />
parallel is possible.<br />
Spectrum <strong>Analysers</strong> - Low Frequency<br />
See also Spectrum Analyser - High Frequency on page 14 & 16<br />
See also Noise & Sound <strong>Analysers</strong> on page 72-73<br />
Agilent/HP 35670A 100kHz Spectrum<br />
Analyser<br />
<br />
<br />
analyser. Up to 1600 line resolution. Displays<br />
frequency response, power spectrum, linear<br />
spectrum, coherence, cross spectrum, power<br />
<br />
waveform, random noise, chirp. Built-in disk drive. HPIB plotter interface.<br />
<br />
measurements respectively.<br />
TV Test Equipment<br />
See also Network <strong>Analysers</strong>/Antenna & Cable Test on page 16 & 18<br />
Promax TV Explorer Prodig-5<br />
PRO,PRODIG-5 (1727) AU<br />
For the installation, maintenance and surveillance<br />
of terrestrial, satellite and cable TV systems.<br />
Automatically provides information about the<br />
channels available in the network and their quality.<br />
Displays analogue and digital channel picture.<br />
Includes a high resolution spectrum analyser<br />
function and MPEG decoding. Foxtel approved.<br />
Promax Prolink 4C Premium<br />
Analogue/Digital TV Test Set<br />
<br />
Measures terrestrial, satellite and cable<br />
TV systems including analogue and digital<br />
VHF & UHF bands. Built in colour monitor provides measurement readout<br />
and can be used to display video signal. Measurement functions include<br />
spectrum analysis, direct signal level readout, carrier to noise, channel<br />
<br />
constellation. DVB digital TV channel identifier. Logs to PC and includes<br />
software for remote control and channel plan management.<br />
12<br />
Laboratory Calibrators<br />
See also Industrial Process Calibrators on page 48-51<br />
www.techrentals.com.au<br />
Fluke 5500A Multi Product<br />
Calibrator with<br />
NATA Calibration<br />
<br />
Calibrator sources direct voltage<br />
& current, alternating voltage and<br />
current, with multiple waveforms<br />
and harmonics, 2 simultaneous voltage outputs or voltage & current.<br />
Simulates power with phase control, resistance, capacitance, thermocouples<br />
and RTDs. Selectable ranges include the following outputs VDC from 0 to<br />
1.02kV, VAC from 1mV to 1.02kV with output from 10Hz to 500kHz. AC<br />
current from 0.01μA to 11A with output from 10Hz to 10kHz. DC current<br />
<br />
values from 330pF to 1,100μF. Temperature t/c B, C, E, J, K, L, N, R, S, T, U,<br />
<br />
<br />
Genrad 1433B 1.1 6 Decade Resistance<br />
<br />
<br />
Genrad 1433F 111k 7 Decade Resistance Box<br />
<br />
<br />
platinum resistance thermometer calibration. NATA calibrated.<br />
Genrad 1433-20 11.1111k<br />
6 Decade Resistor<br />
<br />
<br />
<br />
<br />
<br />
for RTD stimulation. Rack mount option.<br />
Logic <strong>Analysers</strong>/PROM Programmers<br />
HP 1662A 68 Channel Logic Analyser<br />
HP,1662A (1570) AU/MY<br />
<br />
<br />
<br />
<br />
RS232C ports. In-built DOS format FDD used to load inverse assemblers<br />
& transfer measurement data to a computer. Compatible with most HP<br />
preprocessors & inverse assemblers.<br />
IceTech LV48 Programmer<br />
<br />
Eprom programmer for single device with laptop & preloaded software.<br />
<br />
Our ex-rental sales list is sent electronically.<br />
To receive a copy please email your details to
www.techrentals.com.au<br />
Gauss/Tesla Meters<br />
FW Bell Gauss/Tesla Meter<br />
<br />
Handheld digital ELF gauss meter. Maintains<br />
accuracy regardless of orientation. Applications<br />
include detecting magnetic field emissions from<br />
overhead AC power lines, video display terminals,<br />
office equipment and household appliances.<br />
Analogue o/p, data logging, auto range 0.1 to 1999<br />
mG, minimum resolution 0.1mG/.01 uT.<br />
FW Bell 5180 Gauss/Tesla Meter<br />
BEL,5180 (1960) AU<br />
Magnetic measuring equipment, portable gaussmeter.<br />
Functions include Auto Zero, Min/Max/Peak Hold,<br />
Auto Range and Relative Mode. Displays in Gauss,<br />
Tesla or Ampere/Meter. With Hall effect transverse<br />
probe. Bandwidth DC to 30kHz, ranges 300G to<br />
30kG, resolution 0.1G. Analogue output (±3V FS) and<br />
USB interface. Battery operated.<br />
Hirst GM04 Microprocessor Controlled<br />
Gaussmeter<br />
<br />
<br />
Analogue peak with digital storage. Auto and<br />
manual ranges. Automatic reading conversion<br />
between different units. (Note 1mT = 10G).<br />
Ranges 0 to more than 3T resolution 1mT;<br />
299.9mT resolution 100μT; 29.99mT resolution<br />
10μT; 2.999mT resolution 2μT. Accuracy (at<br />
<br />
<br />
RMS max, & AC peak.<br />
E & H Field Strength Meters<br />
See also Radiation Montioring & Protection on page 74<br />
Holaday HI-3002 E & H<br />
Field Strength Meter<br />
<br />
Isotropic RF radiation monitor. E-field &<br />
H-field probes spanning 500kHz to 6GHz<br />
(E-field) & 5 to 300MHz (H-field). Operates<br />
from batteries.<br />
Holaday HI-3004 E Field Strength Meter<br />
<br />
Isotropic broadband field strength meter designed primarily to measure low<br />
level fields for EMI/EMC studies. Meter scale calibrated in v/m, with pointer<br />
deflection proportional to v 2 /m 2 . Supplied with HSE high sensitivity E-field<br />
<br />
<br />
to 6GHz. Recorder output (0 to 1VDC).<br />
Holaday HI-3604 LF E & H Field Monitor<br />
<br />
Low frequency field meter. Designed to evaluate electric and magnetic<br />
fields associated with 50Hz power lines. Frequency range 30 to 2,000Hz.<br />
Measures magnetic fields from 0.1mG to 20G. Measures electric fields<br />
from 1V/meter to 200kV/meter. LCD display. 127 reading data memory.<br />
Meets the interim requirements of the Australian Radiation Laboratory for<br />
normal levels of AC power exposure.<br />
13<br />
ELECTRONICS<br />
E & H Field Strength Meters cont’d.<br />
Holaday HI-3627 Magnetic Field Meter<br />
HOL,HI-3627 (1980) AU<br />
Three orthogonal field sensors. Dynamic<br />
range 0.2mG to 20G. True RMS detection.<br />
Frequency range 5Hz to 2kHz with an in-built<br />
30Hz high pass filter. Meets requirements of<br />
<br />
protocol.<br />
Narda 8616 Radiation Hazard Monitor<br />
NAR,8616 (1950) AU<br />
Radio frequency radiation monitor. Battery operated with analogue<br />
meter and recorder output (3VDC full scale). H field probe (8633) has<br />
a frequency range of 10 to 300MHz over a range of 0.05 to 100mW/cm 2 ;<br />
frequency range up to 200MHz is calibrated to NATA standard.<br />
Narda NBM-550 E Field Strength Meter<br />
NAR,NBM-550 (1930) AU<br />
Broadband field strength meter. Applications include<br />
measuring field strengths to comply with general safety<br />
regulations and actual radiated power. Measuring<br />
broadcasting, radar, cell towers, and other transmission<br />
sources. Includes GPS position, data logging and voice<br />
recording for comments.<br />
EMC & <strong>Power</strong> Disturbance<br />
Simulators<br />
Laplace SA1000 EMC Test System<br />
LAP,SA1000 (8370) AU<br />
Comprises PC controlled spectrum analyser 10kHz to 1.1GHz,<br />
SA1020 pre-amplifier, RF200 broadband antenna 30MHz to 1GHz,<br />
TTI LISN1600 LISN, and RF100 E-field & H-field probes. Supplied<br />
with notebook PC and EMC software. EMC compliance test system.<br />
Schaffner 438 30kV Static Discharge Generator<br />
<br />
Generates an electrostatic charge in a range<br />
from 2 to 30kV. This instrument is in a ‘gun’ form.<br />
Has a removable discharge network which can<br />
be interchanged with other (optional) impedance<br />
<br />
<br />
Schaffner Automated Step Transformer<br />
SFN,INA-6502 (8385) AU<br />
<br />
<br />
control switch.<br />
Schaffner Modula-6100<br />
Immunity Test System<br />
SFN,MODULA 6100 (8380) AU<br />
Multifunction generator to simulate<br />
electro-magnetic field interference effects<br />
for immunity testing in conformity with<br />
international, national and in house standards<br />
including the new IEC/EN standards.<br />
Generates Interference pulses such as burst<br />
and surge and power quality simulations.
RADIO FREQUENCY<br />
RF Signal & Sweep Generators<br />
Frequency Counters<br />
Spectrum <strong>Analysers</strong> - High Frequency<br />
Network <strong>Analysers</strong>/Antenna & Cable Test<br />
Communication Test Sets<br />
Distortion <strong>Analysers</strong><br />
<strong>Power</strong> Meters - RF<br />
<br />
RF Attenuators<br />
Antennas<br />
RF Accessories<br />
RF Signal & Sweep Generators<br />
See also Function Generators on page 10<br />
Agilent/HP 83623B 20GHz<br />
Synthesized Swept Signal/CW<br />
Generator<br />
HP,83623B (2340) AU<br />
Frequency range 0.01 to 20GHz.<br />
1Hz frequency resolution (Opt<br />
008), -110dB to +17dBm o/p power, (Opt 001, minimum setable output<br />
power is -110dBm). Maximum leveled output power is reduced by 1.5dB to<br />
20GHz). External AM, FM and Pulse modulation. For applications requiring<br />
the high performance and accuracy of a synthesized source and the speed<br />
and versatility of a sweep oscillator. Ideal for the demanding requirements<br />
of signal simulation, local oscillator, and stimulus/response component or<br />
subsystem test applications.<br />
Agilent/HP 8648C-1E5 3GHz Signal Generator<br />
HP,8648C MY<br />
Signal generator 9kHz to 3.2GHz with AM/FM/Phase modulation output range<br />
from +10 to -136dBm with ±1 accuracy up to 2.5GHz. 0.001Hz resolution.<br />
Agilent/HP 8648D-1E5 4GHz Signal<br />
Generator<br />
HP,8648D (2330) AU//MY<br />
Signal generator 9kHz to 4GHz with AM/<br />
FM/Phase modulation output range from<br />
+10 to -136dBm with ±1dB accuracy up<br />
to 2.5GHz. 0.001Hz resolution. Complete<br />
with option 1E5 high stability timebase<br />
(
Originally established in 1983 as the<br />
Computer Division of TechRentals,<br />
TR Vidcom is Australia’s vibrant company<br />
in the exciting IT and Audio Visual industry.<br />
Specialists in supplying IT hardware, project management, audio<br />
visual turn key solutions and facilitating short and long term projects on<br />
everything IT and AV, TR Vidcom delivers unparalleled levels of service<br />
and a comprehensive range of leading-edge products at competitive rates.<br />
Our product range includes:<br />
<br />
<br />
<br />
<br />
<br />
<br />
Our vision at TR Vidcom is to respond to clients’ needs by combining<br />
technology, equipment and technical expertise.<br />
To request a copy of TR Vidcom’s<br />
Guide to Rental Services and<br />
Solutions, call one of our experts<br />
on 1800 843 266.<br />
vidcom<br />
1800 843 266<br />
www.trvidcom.com.au<br />
rent@trvidcom.com.au<br />
<br />
<br />
Whiteboards<br />
<br />
<br />
<br />
VC0185
RADIO FREQUENCY<br />
Spectrum <strong>Analysers</strong> - High Frequency<br />
cont’d.<br />
Airmagnet Wi-Fi Spectrum Analyser<br />
AIR,AIRMAG SPEC AN (2520) AU<br />
Laptop based spectrum analyser. Specifically identify sources of interference<br />
in Wi-Fi bands 2.4-2.5GHz (802.11 b/g) and 4.9-5.9GHz (802.11a), and<br />
track them to their physical source. Automatic and real time identification<br />
of Bluetooth, cordless phones, microwaves, analogue video cameras, RF<br />
jammers and more. Immediately “see” and name each device.<br />
Anritsu MS2711A 3GHz Portable<br />
Spectrum Analyser<br />
ANR,MS2711A MY<br />
Portable spectrum analyser, 9kHz to 3GHz.<br />
Light weight battery powered spectrum<br />
analyser with LCD. Resolution bandwidth<br />
down to 10kHz. Suitable for cellular telephone<br />
walk or drive tests to determine coverage and base station positioning. Can also<br />
be used for VHF/UHF signal surveying. N type connector.<br />
Anritsu MS2711D 3GHz Colour Portable<br />
Spectrum Analyser<br />
ANR,MS2711D (2548) AU<br />
Light weight, battery powered with colour<br />
LCD. Range 9kHz to 3GHz. Resolution<br />
bandwidth from 100Hz to 1MHz. -135<br />
dBm Noise Floor. Can identify the type of<br />
interfering signal. Used in applications such as cellular telephone walk or drive<br />
tests to determine coverage and base station positioning and VHF/UHF signal<br />
surveying. N type connector.<br />
Anritsu MS2711D 3GHz Spectrum Analyser GPS & Interference Analysis<br />
ANR,MS2711D -31-25 (2547) AU<br />
9kHz to 3GHz. Resolution bandwidth from 100Hz to 1MHz. Interference<br />
Analysis opt provides spectrogram display, RSSI and signal strength with<br />
audio output for radio direction finding. GPS function provides Latitude,<br />
Longitude and Altitude with trace storage. Can be used in applications such as<br />
cellular telephone walk or drive tests to determine coverage and base station<br />
positioning and also VHF/UHF signal surveying. N type connector.<br />
Anritsu MS2721A 7.1 GHz Spectrum<br />
Analyser<br />
ANR,MS2721A (2549) AU<br />
For deploying, maintaining and<br />
troubleshooting wireless base stations and<br />
Wi-Fi (802.11a, b and g) systems, and general<br />
spectrum analysis. Smart measurements<br />
include channel power, adjacent channel power ratio, Carrier to Interference<br />
ratio (C/I), and field strength. AM/FM/SSB demodulator is included and internal<br />
speaker for monitoring. Store unlimited traces and setups.<br />
Agilent/HP E4407B 26.5GHz Spectrum<br />
Analyser<br />
HP,E4407B (2540) AU<br />
Frequency range 9kHz to 26.5GHz. Resolution<br />
bandwidth down to 30Hz. Noise level -105<br />
to -136dBm according to frequency. Centre<br />
frequency display with a resolution of up to 10Hz. Stores up to 200 traces in<br />
internal memory and 200 traces on disk.<br />
Agilent/HP 8593E 22GHz Spectrum Analyser<br />
HP,8593E MY<br />
Frequency range 9kHz to 22GHz. Max resolution 30Hz. Noise level -102 to<br />
-127dBm according to frequency. Centre frequency display with a resolution<br />
of up to 10Hz. Some assets include GPIB/parallel and narrow resolution<br />
bandwidth options (041 & 130).<br />
16<br />
Spectrum <strong>Analysers</strong> - High Frequency<br />
cont’d.<br />
Protek 3290 2.9GHz RF Analyser/Signal Meter<br />
PRO,3290 (2585) AU<br />
RF signal analyser and level meter. Provides spectrum<br />
display up to 2.9GHz, audio output, level measurement,<br />
and frequency measurement. Inbuilt antenna. Frequency<br />
range 100kHz to 2.9GHz with frequency steps from 5kHz.<br />
Modulation types narrow and wide band FM, AM, and SSB.<br />
Level measurement minimum frequency - narrow band FM<br />
1MHz, wide band FM, AM, SSB 10MHz. Bandwidth - narrow<br />
band FM 12.5kHz, wide band FM 180kHz, AM & SSB 2.4kHz.<br />
<br />
Rohde & Schwarz FSH3 3GHz Spectrum Analyser/Tracking Generator/<br />
Vector Measurement<br />
RS,FSH3-TG MY<br />
Handheld portable battery operated spectrum analyzer 100 kHz to 3 GHz.<br />
Resolution bandwidth 1 kHz to 1 MHz. Less than -105 dBm noise level (-116 dBm<br />
typical). Colour liquid crystal display. Suitable for RF surveying applications.<br />
Includes tracking generator, VSWR bridge and distance to fault (DTF) options<br />
making it suitable for antenna and cable testing. 4 hours of continuous operation<br />
on battery power. Comes with cable for data transfer to PC.<br />
Rohde & Schwarz FSH3 3GHz Spectrum Analyser/<br />
Tracking Generator/Vector Measurement<br />
RS,FSH3-TG-V (2536) AU<br />
Handheld portable battery operated spectrum analyser<br />
100kHz to 3GHz. Resolution bandwidth 1kHz to 1MHz.<br />
Less than -105dBm noise level (-114dBm typical).<br />
Suitable for RF surveying applications. Includes vector<br />
transmission and tracking generator options.<br />
Rohde & Schwarz FSH6 6GHz Spectrum Analyser/Tracking Generator<br />
RS,FSH6-TG (2537) AU<br />
Handheld battery operated spectrum analyser 100kHz to 6GHz. RBW 1kHz to<br />
1MHz. Noise level to 3GHz, -112dBm; 5 to 6GHz, -102dBm typically. Suitable<br />
for RF surveying applications. Includes, VSWR bridge and DTF options<br />
making it suitable for antenna and cable testing.<br />
Network <strong>Analysers</strong>/Antenna<br />
& Cable Test<br />
www.techrentals.com.au<br />
Agilent FieldFox 6GHz RF Analyser<br />
N9912A<br />
AGI,N9912A (2145) AU/MY<br />
Cable and antenna analyser. Frequency range 2MHz<br />
to 6GHz. Measures return loss, one-port cable loss,<br />
distance to fault, line sweeping, and VSWR. Applications<br />
include cable & antenna installation and maintenance<br />
for wireless service providers, contractors, military,<br />
aerospace, defence, and public safety applications.<br />
Anritsu S331D 4GHz Colour<br />
Sitemaster Antenna<br />
ANR,S331D (2120) AU/MY<br />
Antenna and cable test set. Frequency range<br />
2.5GHz to 4GHz. Measures return loss, SWR,<br />
cable loss, and distance to fault. Return loss<br />
range 0 to 60dB. SWR range 1 to 65. Distance<br />
to fault range 1,197m. Insertion loss range -120 to +100dB. Cable loss range<br />
(one port) 0 to 30dB. N(f) Type port. Analysis software discs included containing<br />
distance to fault and Smith chart tools. Complete with calibration standard,<br />
AC/DC adaptor, and 12VDC car cigarette lighter adaptor.
RADIO FREQUENCY<br />
Network <strong>Analysers</strong>/Antenna<br />
& Cable Test cont’d.<br />
Anritsu S331E 4GHz Sitemaster<br />
Cable & Antenna Tester<br />
ANR,S331E (2119) AU/MY<br />
Cable and antenna analyser, frequency range<br />
2MHz to 4GHz. Measures return loss, VSWR,<br />
cable loss, and Distance To Fault. Suitable for<br />
legacy networks in addition to the new 3G and<br />
4G networks being installed. Applications include cable & antenna installation<br />
and maintenance for wireless service providers, contractors, military,<br />
aerospace, defence, and public safety applications.<br />
Anritsu S332D Colour Sitemaster<br />
Antenna Tester<br />
ANR,S332D MY<br />
Antenna and cable test set including spectrum<br />
analyser. Frequency range 25 to 4,000MHz.<br />
RBW 100Hz to 1MHz. Measures return loss,<br />
SWR, cable loss, and distance to fault. N(f) Type port. Analysis software<br />
containing DTF and Smith chart tools included. Complete with calibration<br />
standard, AC/DC adaptor, and 12VDC car adaptor.<br />
Anritsu S332E Sitemaster<br />
including Spectrum Analyser<br />
ANR,S332E (2141) AU<br />
Antenna and cable analyser 2MHz to 4GHz<br />
and spectrum analyser 100KHz to 4GHz.<br />
DANL -152dBm. Measures return loss, VSWR,<br />
cable loss, and distance to fault. N(f) Type<br />
port. Analysis software containing DTF and Smith chart tools included.<br />
Complete with calibration standard, AC/DC adaptor, and 12VDC car adaptor.<br />
Cable & antenna installation and maintenance for wireless service providers,<br />
contractors, military, aerospace and defence, and public safety applications.<br />
Anritsu S332E Sitemaster<br />
Including Spectrum Analyser<br />
and Opt 431,31,509<br />
ANR,S332E-CMPA-MOD (2142) AU<br />
antenna and cable analyser 2MHz to 4GHz and<br />
spectrum analyser 100KHz to 4GHz. DANL<br />
-152dBm. Options included, indoor outdoor<br />
Coverage Mapping, GPS Receiver and AM/FM/PM Analyser. Measures<br />
return loss, VSWR, cable loss, and distance to fault. Analysis software<br />
containing DTF and Smith chart tools included. Cable, antenna, installation<br />
and maintenance spectrum analysis, coverage mapping and AM/FM/PM<br />
demod for wireless service providers, contractors, military, aerospace and<br />
defence, and public safety applications.<br />
Anritsu S820A Microwave Sitemaster 3 to 20GHz<br />
ANR,S820A (2160) AU<br />
Microwave antenna and cable test set. Portable (1.14kg) single post analyser,<br />
providing return loss (SWR) insertion loss and distance to fault measurements<br />
in the frequency range of 3.3GHz to 20GHz. Unit comes standard with RS232<br />
interface, Smith chart and software management tools, AC/DC and automotive<br />
adaptor. A comprehensive range of precision waveguide components and<br />
adaptors are available.<br />
Anritsu S820D Microwave Sitemaster<br />
25MHz to 20GHz<br />
ANR,S820D (2150) AU/MY<br />
Microwave antenna and cable test set. Portable<br />
single port analyser, providing return loss<br />
(SWR) insertion loss and distance to fault<br />
measurements in the frequency range of 25MHz to 20GHz. Unit comes<br />
standard with RS232 interface, Smith chart and software management tools,<br />
AC/DC and automotive adaptor. A comprehensive range of precision waveguide<br />
components and adaptors are available.<br />
18<br />
Network <strong>Analysers</strong>/Antenna<br />
& Cable Test cont’d.<br />
Anritsu Sitemaster Waveguide Components<br />
ANR,WAVEGUIDE-ADAP (2170) AU/MY<br />
Calibration components and wave guide to co-ax adaptors for Anritsu S820x<br />
Sitemaster. Set includes 1/8 and 3/8 shorts, termination, and waveguide to<br />
co-ax adaptor.<br />
Agilent/HP 8753D 6GHz Vector Network Analyser<br />
HP,8753D (2745) AU<br />
Vector network analyser with integral S-parameter test set. Frequency range<br />
30kHz to 6GHz with included option 006. In-built 1Hz resolution synthesized<br />
signal source. Calibration kit included.<br />
Agilent/HP 8757D Scalar Network Analyser<br />
HP,8757D (2700) AU<br />
Measures insertion loss, gain, return loss, SWR, and power from 10MHz to 110GHz.<br />
Supplied with 3x11664A detectors, 10MHz to 18GHz, Range +10dBm to -50dBm.<br />
Communication Test Sets<br />
Agilent/HP 8920A Communications Test Set<br />
HP,8920A (2375) AU<br />
Frequency range of 250kHz to 1GHz.<br />
Includes an AM/FM signal generator, AM/FM<br />
modulation analyser, duplex offset generator,<br />
SSB demodulator, RF power meter, frequency<br />
counter, AC/DC voltmeter, SINAD meter, distortion meter, oscilloscope<br />
and two variable audio sources. Includes spectrum analyser with tracking<br />
generator. Antenna & microphone are included.<br />
Marconi 2945 Communications Test Set<br />
MAR,2945 (2370) AU<br />
Communications service monitor. Output<br />
frequency range 400kHz to 1.05GHz. Input<br />
frequency range to modulation monitor and<br />
spectrum analyser 100kHz to 1.05GHz.<br />
Tracking generator with offset tracking<br />
inbuilt. <strong>Power</strong> measurement to 150W. Full duplex operation. Spectrum<br />
analyser with 1kHz resolution. AC mains, external 11 to 32V. RS232C remote<br />
control interface.<br />
PCTel Scanning Receiver<br />
PCT,EX-QUAD (2365) AU<br />
EX Scanner GSM 900/1800 WCDMA 2100/900.<br />
High speed Top N Scrambling Code Scanning.<br />
GSM colour code (BSIC) Scanning. Multiple<br />
concurrent measurements. RSSI and immediate RSSI reporting. Spectrum<br />
analysis measurements. Layer 3 BCH/BCCH decoding. High accuracy C/I<br />
measurements. Built-in GPS receiver.<br />
Distortion <strong>Analysers</strong><br />
www.techrentals.com.au<br />
Agilent/HP 8903B Audio Analyser<br />
HP,8903B (3020) AU<br />
Audio analyser for communications and other applications. Measures<br />
distortion, sinad, signal-to-noise, ACV, DCV, frequency. Low distortion<br />
programmable sine wave source. Frequency range 20Hz to 100kHz. Optional<br />
400Hz high pass and CCITT weighting filters fitted.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.
www.techrentals.com.au<br />
<strong>Power</strong> Meters - RF<br />
Agilent/HP 8481B <strong>Power</strong> Sensor 1mW to<br />
25W, 10MHz to 18GHz<br />
HP,8481B (2110) AU<br />
<strong>Power</strong> sensor for HP 436A, E4418 or E4419 series power meters. 10MHz to<br />
18GHz, 1mW to 25W.<br />
Agilent/HP E4418B E Series <strong>Power</strong> Meter<br />
HP,E4418B-001 (2103) AU<br />
100μW to 25W (-70dBm to 44dBm), 9kHz to<br />
18GHz (depending on power sensor), 4 digit<br />
display - watts, dBm, dB (rel). Battery or mains<br />
powered. <strong>Power</strong> sensor required, select and<br />
specify when ordering.<br />
Agilent/HP E9300A <strong>Power</strong> Sensor 1μW to 100mW, 10MHz to 18GHz<br />
HP,E9300A (2108) AU<br />
<strong>Power</strong> sensor for HP EPM series power meters. E-series average power<br />
sensor. 10MHz to 8GHz, 1μW to 100mW (-60dBm to 20dBm).<br />
Agilent/HP E9300B <strong>Power</strong> Sensor 1μW to<br />
25W, 10MHz to 8GHz<br />
HP,E9300B (2109) AU<br />
<strong>Power</strong> sensor for HP EPM series power meters.<br />
E-series average power sensor. 10MHz to<br />
18GHz, 1μW to 25W (-30dBm to 44dBm).<br />
Agilent/HP E9300H <strong>Power</strong> Sensor 10nW to 1W, 10MHz to 18GHz<br />
HP,E9300H (2108) AU<br />
<strong>Power</strong> sensor for HP EPM series power meters. E-series Average <strong>Power</strong><br />
Sensor. 10MHz to 18GHz, 10nW to 1W (-50dBm to 30dBm).<br />
Bird 43 <strong>Power</strong> Meter<br />
BIR,43 MY<br />
RF thruline power meter. Requires Bird element of specified frequency and<br />
power. Measures forward and reflected power by reversing the element.<br />
Bird RF Element<br />
BIR,ELEMENT-LF MY<br />
BIR,ELEMENT-HF MY<br />
RF elements for Bird watt meters. Available in various power and frequency<br />
ranges.<br />
Marconi 6910 <strong>Power</strong> Sensor<br />
MAR,6910 MY<br />
<br />
<br />
element semiconductor thermocouple. VSWR 1.25: 10MHz to 30MHz, 1.1:<br />
30MHz to 2GHz, 1.18: 2 to 16GHz, 1.28: 16 to 18GHz, 1.4: typical 18 to 20GHz.<br />
Linearity factor provided with sensor. Accuracy ±0.5% at 25C between 10<br />
& 20dBm. Improves by a factor of 10 for each lower range. Calibration factor<br />
provided with sensor. Accuracy uncertainty provided with sensor. Resolution<br />
<br />
Marconi 6912 <strong>Power</strong> Sensor<br />
MAR,6912 MY<br />
<br />
(100mW).<br />
Marconi 6913 <strong>Power</strong> Sensor<br />
MAR,6913 MY<br />
<br />
<br />
element semiconductor thermocouple. VSWR 1.40: 10MHz to 50MHz, 1.15:<br />
50MHz to 100MHz, 1.10: 100MHz to 2GHz, 1.15: 2 to 12.4GHz, 1.20: 12.4 to<br />
18GHz, 1.25: 18 to 26.5GHz. Calibration factor provided at 1GHz intervals<br />
(500MHz intervals above 20GHz) with each sensor. Accuracy uncertainty<br />
provided with each sensor. Resolution 0.01%. Linearity factor accuracy ±0.5%<br />
at 100mW, decreasing by 0.005% per 1mW.<br />
19<br />
<strong>Power</strong> Meters - RF cont’d.<br />
Marconi 6920 <strong>Power</strong> Sensor<br />
MAR,6920 MY<br />
High sensitivity diode sensor. Frequency range 10MHz to 20GHz. <strong>Power</strong><br />
<br />
<br />
1.4 to 1.2:10 to 40MHz, 1.20:40MHz to 10GHz, 1.35:10 to 18GHz, 1.40<br />
typical 18 to 20GHz. Calibration factor provided at 1GHz intervals with each<br />
sensor. Accuracy uncertainty provided with each sensor.<br />
Marconi 6923 RF <strong>Power</strong> Sensor<br />
MAR,6923 MY<br />
High sensitivity diode sensor. Frequency range 10MHz to 26.5GHz. <strong>Power</strong><br />
<br />
<br />
1.4 10 to 40MHz, 1.15 40 to 100MHz, 1.12 0.1MHz, 1.17 2 to 8GHz, 1.30 8<br />
to 18GHz, 1.50 typical 18 to 26.5GHz. Calibration factor provided at 1GHz<br />
intervals with each sensor. Accuracy uncertainty provided with each sensor.<br />
Resolution 0.01%. Linearity factor provided with each sensor. Accuracy<br />
<br />
Marconi 6970 Digital <strong>Power</strong> Meter<br />
MAR,6970 MY<br />
NiCd battery operated with digital display. Complete with AC adaptor. Requires<br />
sensor. Sensors available for 10MHz to 26.5GHz frequency range.<br />
Rohde & Schwarz NRT <strong>Power</strong> Reflection Meter<br />
RS,NRT AU<br />
Measures directional power forward and reverse under operational<br />
conditions. NRT-Z44 sensor included, range 3 mW to 120 W, 200 MHz to<br />
4 GHz. Measurement method is compatible with all common analog and in<br />
particular digital modulation standards. GSM/EDGE, 3GPP (W-/TD-CDMA),<br />
CDMA (IS-95), CDMA2000, PHS, NADC, PDC, TETRA, DECT, DAB, DVB-T<br />
and many more.<br />
<br />
ENI 604L 4W Wideband 1GHz RF Amplifier<br />
ENI,604L (2803) AU<br />
Linear wideband RF power amplifier. 4W output at an input of 0.13mW from<br />
0.5 to 1GHz. Saturated output 7W 0dBm input. Extended performance<br />
gives saturated output to a max of 16W at 10MHz and 12W at 100MHz<br />
typically.<br />
Agilent/HP HP8449B Preamplifier 1GHz to 26.5GHz<br />
HP,8449B (2805) MY<br />
High-gain (+30dB gain), low-noise preamplifier. Frequency range of 1 to<br />
26.5GHz. Increases sensitivity of any microwave spectrum analyser for<br />
detection and analysis of very low-level signals. Improved sensitivity can<br />
reduce measurement time.<br />
RF Attenuators<br />
RADIO FREQUENCY<br />
Agilent/HP 8494B 11 x 1dB 18GHz Coaxial Step Attenuator<br />
HP,8494B (2901) AU<br />
DC to 18GHz. 0 to 11dB in 1dB steps. 1W average power handling. Option 001.<br />
Type N(f) connectors.<br />
Agilent/HP 8494B/8495B Attenuator Set 81dB, 1 & 10dB steps 18GHz<br />
HP,8494B-8495B (2904) AU<br />
Coaxial step attenuator set. DC to 18GHz. 0-11dB in 1dB steps and 10-70dB in<br />
10dB steps. Type N(f) connectors. Comprises a connected set of types 8494B<br />
and 8495B with 11716A rigid interconnect kit.
PROJECT RENTALS<br />
Is your major project?<br />
<br />
<strong>Power</strong> Generation<br />
With over 35 years experience TechRentals technical sales staff will assist you in delivering the right test and<br />
measurement solution for your major project. Whatever the duration, the best solution will be tailored to your<br />
requirements, making this part of your project simple and easy.<br />
With access not only to our vast inventory but to our global partners’ inventory you can be assured we will deliver<br />
the best solution for you.<br />
20<br />
www.techrentals.com.au
www.techrentals.com.au<br />
RF Attenuators cont’d.<br />
Agilent/HP 8495B 70dB x 10dB Coaxial Step Attenuator<br />
HP,8495B (2902) AU<br />
DC to 18GHz. 0 to 70dB in 10dB steps.<br />
Agilent/HP 8494/5B Coaxial Step Attenuator Set 81dB x 1dB<br />
HP,8494/5B MY<br />
DC to 18GHz. 0 to 11dB in 1dB steps. 11 to 81dB in 10dB steps. Comprises a<br />
connected set of types 8494B & 8495B. Type N(f) connectors.<br />
Agilent/HP 8495D 70dB 26.5GHz Step Attenuator<br />
HP,8495D (2905) MY<br />
Frequency range DC to 26.5GHz. 70dB step attenuator in 10dB steps. Max<br />
continuous power 1W. 3.5mm connectors.<br />
Anritsu Attenuator 50W 30dB DC to 18GHz<br />
ANR,50-30-18 (2903) AU<br />
30dB, 18GHz, 50W. N Type connectors.<br />
<br />
BIR,8080 MY<br />
<br />
Weinschel 23-10-34 10W 10dB DC-18GHz RF Attenuator<br />
WEI,23-10-34 (2918) AU<br />
DC to 18GHz, 10dB, 10W. Type N connectors.<br />
Weinschell 33-10-34 25W 10dB 8.5GHz RF Attenuator<br />
WEI,33-10-34 (2919) AU<br />
DC to 8GHz, 10dB, 25W. Type N connectors.<br />
Weinschell 34-30-34 25W 30dB 4GHz RF Attenuator<br />
WEI,34-30-34 (2922) AU<br />
DC to 4GHz, 30dB, 25W. Type N connectors.<br />
Weinschell 46-03-34 50W 3dB 18GHz RF Attenuator<br />
WEI,46-03-34 MY<br />
Weinschell 46-06-34 50W 6dB 18GHz RF Attenuator<br />
WEI,46-06-34 MY<br />
DC to 18GHz, 6dB, average power 25W, 200W peak. Type N connector.<br />
Weinschell 46-10-34 50W 10dB 18GHz RF Attenuator<br />
WEI,46-10-34 MY<br />
DC to 18GHz, 10dB, average power 25W, 200W peak. Type N connector.<br />
Weinschell 46-20-43 25W 20dB 18GHz RF Attenuator<br />
WEI,46-20-43 (2921) AU/MY<br />
DC to 18GHz, 20dB, 25W. Type N connectors.<br />
Weinschel 82-30-34, 30dB 1000W 3GHz<br />
Coaxial Attenuator<br />
WEI,82-30-34 (2924) AU<br />
DC to 3GHz, 30dB, 1,000W.<br />
Weinschell AS6 Calibrated Attenuator Set<br />
WEI,AS6 MY<br />
Frequency range DC to 18GHz, set consists of 4 different nominal value 3, 6,<br />
10 & 20dB. Connector type N per mil-STD-348, power rating 5W.<br />
Weinschell M2-20 Attenuator<br />
WEI,M2-20 MY<br />
DC to 18GHz, 20dB, double male N type.<br />
21<br />
Antennas<br />
Advantest TR1720 100kHz to 30MHz Antenna<br />
ADV,TR1720 (1847) AU<br />
Loop and vertical antenna system. Frequency range 100kHz to 30MHz.<br />
Suitable for use with ADV,R4131D for field strength and EMI measurements.<br />
Antenna tuner included which can be used as an input/output filter to reject<br />
noise below the measuring frequency.<br />
AH Systems 300MHz to 12GHz Antenna System<br />
AH,ANTENNA (1834) AU<br />
Log periodic antenna system. Comprises two antennas: A: 300MHz to<br />
1.8GHz, power handling 1kW, antenna factor 15 - 32dB, B: 1 to 12GHz, power<br />
handling 10 W, antenna factor 25 - 44dB. Complete with tripod.<br />
AH Systems SAS-200/550-2B 100Hz to 60Mhz Rod Antenna<br />
AH,SAS-200/550 (1837) AU<br />
Monopole rod antenna. Frequency range 100Hz to 60MHz. Active unit with<br />
battery power. Rod height 220mm to 1.09m. Ground plane 450 x 450mm.<br />
Antenna factor 0 to 24.<br />
AH Systems SAS-200/571 Antenna<br />
AH,SAS-200/571 (1840) AU<br />
AH,SAS-571 MY<br />
Double ridge guide horn antenna. Frequency range 700MHz to 18GHz.<br />
<br />
N(f) connector.<br />
Anritsu Dipole Antenna Kit<br />
ANR,ANTENNA (1834) AU<br />
Comprises types MP534A and MP651A antenna covering 25 to 520MHz &<br />
470 to 1,700MHz. Complete with tripod type MB9A and coaxial cable.<br />
Directional Yagi Antenna<br />
ANT,DIRECTIONAL YAGI (1829) AU<br />
Various directional Yagi antennas. Frequency rangers from 824 M (UHF) to<br />
2.17 GHz (UHF).<br />
Omnidirectional Antenna<br />
ANT,OMNIDIRECTIONAL (1826) AU<br />
Various omnidirectional antenna types such as telescopic whip, folded dipole<br />
and monopole. Frequency ranges from 70MHz to 2.17GHz.<br />
COM <strong>Power</strong> Double Ridged Horn Antenna 1 to 18GHz<br />
COM,AH-118 MY<br />
Frequency range 1 to 18GHz, VSWR 2.0:1, Polarization: Linear, Output<br />
<br />
Rohde & Schwarz HL013 80MHz to 1.3GHz Log-Periodic Antenna<br />
RS,HL013 (1848) AU<br />
Complete with tripod.<br />
RF Accessories<br />
RADIO FREQUENCY<br />
RF Cables - Various Lengths and Connectors<br />
TR,RF-CABLES (2817) AU<br />
RF cables. Various lengths and connectors<br />
RF Connector Kit N, BNC, TNC, SMA, APC7<br />
TR,RF-CONN (2816) AU<br />
RF connection adaptors. Comprises couplers with interchangeable<br />
connectors; DIN 7/16, N Type, BNC, SMA, TNC, APC-7 and UHF<br />
Huber & Suhner Sucoflex 104PE 26.5GHz RF Cable<br />
SUH,SUCOFLEX-104PE MY<br />
Fexible high performance microwave cable with frequency range up to<br />
26.5GHz. Length 1.0 meter and comes with 3.5mm connectors.
DATA & TELECOMMUNICATIONS<br />
LAN Cable Testers<br />
LAN/WAN <strong>Analysers</strong><br />
PDH/SDH <strong>Analysers</strong><br />
DSL/POTS Test Set<br />
Light Sources & <strong>Power</strong> Meters<br />
Fusion Splicers<br />
OTDR, FC & Fibre Accessories<br />
Fibre Optic Launch Cables & Patch Leads<br />
Microwave Link <strong>Analysers</strong><br />
LAN Cable Testers<br />
Fluke DTX1800 Cable Analyser<br />
900MHz Cat 7<br />
FLU,DTX1800 (3260) AU/MY<br />
Category 7 cable certification tester up to 900MHz.<br />
Tests to Category 3, 4, 5, 5E, 6, 6a and 7. Cable analyser<br />
for use with shielded and unshielded twisted pair Cat 6<br />
Autotest time of 12 seconds. Linkware PC software, and<br />
USB cable included. Internal memory stores results.<br />
Optional multimode & single mode OTDR module.<br />
Fluke DTX-MFM2 Multimode<br />
Fibre Adaptor for DTX Cable<br />
Analyser<br />
FLU,DTX-MFM2 (3270) AU<br />
FLU,DTX-MFM2 MY<br />
DTX1200/1800 multimode fibre interface. Tests<br />
fibre installations in local area networks. Fits in the slot on the back of DTX<br />
cable analyser (standard copper cable adaptors can be connected but not<br />
used simultaneously). Provides fibre testing and certification. Bi-directional<br />
testing at 850nm & 1300nm at the same time. Measures optical power loss,<br />
length, and propagation delay for multimode fibres. Pass/fail results based<br />
on common fibre standards. Includes in built visual fault locator. (VFL).<br />
Fluke DTX Compact OTDR SM-MM<br />
FLU,DTX-OTDR (3280) AU<br />
Full featured multimode & single mode OTDR module that<br />
snaps onto a DTX Cable Analyser. Shoots and analyses<br />
traces on single mode 9nm and multimode 62.5 & 50nm<br />
fibre.<br />
Fluke DTX Permanent Link Adaptor Analyser<br />
FLU,DTX-PLA (3295) AU<br />
Fluke PLA001 Permanent Link Adaptor.<br />
Fluke DTX-SFM2 Multimode<br />
Fibre Adaptor for DTX Cable<br />
Analyser<br />
FLU,DTX-SFM2 AU/MY<br />
DTX1200/1800 single mode fibre interface.<br />
Use for testing fibre installations in local area networks. Fits in the slot<br />
on the back of DTX cable analyser (standard copper cable adaptors can<br />
be connected but not used simultaneously). Provides fibre testing and<br />
certification. Bi-directional testing at 1310nm and 1550nm at the same<br />
time. Measures optical power loss, length, and propagation delay for single<br />
mode fibres. Pass/fail results based on common fibre standards. SC optical<br />
connectors. Includes in built visual fault locator. (VFL)<br />
22<br />
LAN Cable Testers cont’d.<br />
LAN/WAN <strong>Analysers</strong><br />
www.techrentals.com.au<br />
Fluke Siemon Tera Class F Cat 7 Adaptor Kit<br />
FLU,DTX-TERA KIT (3285) AU<br />
Includes 2 TERA channel adaptors and 2 TERA<br />
permanent link adaptors to test Siemon TERA<br />
class F, Cat 7 systems.<br />
EXFO AXS-200-850 Ethernet Test Set<br />
EXF,AXS-200_850 (3228) AU/MY<br />
For installing, turning up or maintaining ethernet and IP<br />
services. Bi-directional RFC 2544 testing. Applications<br />
include performance assessment of carrier ethernet<br />
services, activation and maintenance of metro ethernet<br />
networks, deployment of active ethernet (point-to-point)<br />
access services, traffic generation and monitoring for<br />
network performance testing Bit-error-rate testing (BERT) up to layer<br />
4. Pass/fail results with user-defined thresholds. QoS, ToS and diffserv<br />
capabilities.<br />
EXFO ETS-1000L 10/100/1000 Ethernet Loopback<br />
EXFO,ETS-1000L MY<br />
Ethernet/Gigabit ethernet loopback unit ETS-1000L is intended for performing<br />
loopback at the physical, data link, network and transport layers of the OSI<br />
model. It allows carrying out loopback control via OAM protocol and remote<br />
control via TELNET protocol.<br />
EXFO FTB-860G NetBlazer<br />
10G Ethernet Tester<br />
EXF,FTB-860G (3223) AU<br />
Performs 10 Gbps RFC 2544 measurements<br />
and EtherSAM (ITU-T Y.156sam), for turnkey<br />
deployment, validation, and troubleshooting of<br />
access and metro ethernet services. IPv6 testing<br />
capabilities BERT, RFC, traffic gen and through mode. NetBlazer offers<br />
GUI navigation, dedicated quick-action buttons, and clear notifications for<br />
accurate interpretation of test results.<br />
Fluke Networks Etherscope<br />
Gigabit LAN Analyser<br />
FLU,ETHERSCOPE-EX (3226) AU<br />
<br />
analyser. Complete RFC-2544 SLA testing.<br />
Discover network elements and fault location<br />
even in a switched and wireless environment.<br />
IP analysis of carrier ethernet services. VLAN discovery, connected host<br />
details and trending data. Document and report network performance. Comes<br />
complete with cable ID accessory for tracking cable routes.<br />
Fluke Optiview Pro Gigabit<br />
10/100/Gigabit LAN Analyser<br />
FLU,OPTIVIEW-GIG (3227) AU<br />
Provides network analysis on 10/100/Gigabit<br />
ethernet networks (multimode fibre & copper).<br />
Features active discovery in switched networks,<br />
full 7 layer analysis, ITO (Internetwork Throughput<br />
Option), trace switch route, free string match,<br />
reporting and documenting, address-to-name<br />
mapping, packet capture and decode, SNMP device analysis, RMON II traffic<br />
analysis, application level traffic analysis and much more.
<strong>Power</strong>ful, Comprehensive and<br />
Fast Multiservice Testing<br />
The FTB-880 NetBlazer offers comprehensive<br />
and simple test suites for field technicians<br />
to easily turn up, validate and troubleshoot<br />
DSn/PDH, SONET/SDH and Ethernet services<br />
up to 10 Gbit/s in converged optical networks.<br />
View product demo at www.EXFO.com<br />
Multiservice Tester<br />
FTB-880 NetBlazer<br />
Meet the future<br />
of 10G testing<br />
DATA & TELECOMMUNICATIONS<br />
LAN/WAN <strong>Analysers</strong> cont’d.<br />
Nettest Winpharaoh 2Mbps WAN Analyser<br />
GNE,WINPHARAOH2 WAN (3232) AU<br />
Description - WAN analyser up to 2 Mbit<br />
with the following interfaces: RS232, RS422,<br />
RS423, RS449, RS530, V.35, X.21/V.11. Has<br />
BERT testing for WAN. Full line rate capturing,<br />
statistical analysis, time stamping and emulation<br />
capabilities.<br />
Spirent Communications SPT-2000A Test Centre<br />
SPI,SPT-2000 (3242) AU<br />
Network performance analysis systems that Includes software and hardware<br />
components to simplify and accelerate the testing process from 10 Mb/s to 100<br />
Gb/s. Multiple interface cards, mainframes and software packages available.<br />
Spirent Smartbits SMB6000B with<br />
Interface Modules<br />
SPI,SMB6000 (3243) AU<br />
High port density network performance<br />
analysis test system. Determine router<br />
and network performance including<br />
latency, latency variation and jitter. Can be used to load network with definable<br />
traffic to determine routing performance and discover throughput bottlenecks.<br />
Supplied with standard software and 30 day version of Smartflow application.<br />
2x LAN-3101B, LAN-3201B, LAN-3310A interfaces included.<br />
PDH/SDH <strong>Analysers</strong><br />
Digital Lightwave NICPlus 10G SDH Tester<br />
with Gb Ethernet<br />
DLW,NICPLUS10G (3460) AU<br />
Gigabit/OC-192/STM-64 Network Information<br />
Computer (5 slot chassis). Multirate interface<br />
for STS-1 OC-1/3/3c/12/12c/48/48c STM-<br />
0e/1e/0/1/1c/4/4c/16/16c and interface for<br />
OC-192/192c STM-64/64c with the ability<br />
to monitor down to the STS-1/STM-0 level inside of any supported optical<br />
rate. Used for verifying and qualifying the performance of SDH and DWDM,<br />
and Gigabit Ethernet, telecommunications networks. Electrical and optical<br />
interfaces (1550nm for 10G, all other rates 1310/1550). Includes concatenated<br />
payload support and OC-48/STM-16 add/drop. G.709/975 OTU 1/OUT 2<br />
FEC software installed 10.4 inch active matrix touch screen GUI operation.<br />
Measures optical power and frequency. PCMCIA slots available for memory<br />
cards and peripherals.<br />
JDSU ANT 5 SDH/PDH Access Tester<br />
JDSU,ANT5-STM4 (3445) AU<br />
ACT,ANT5 - STM4 MY<br />
Field tester for the installation, commissioning<br />
and fault finding of fibre and copper SDH/PDH<br />
networks. Electrical interfaces for PDH/SDH:<br />
E1, E3, DS3, E4, STM-0e/1e; Optical interfaces<br />
for SDH/SONET: STM-1/OC-3, STM-4/OC-12.<br />
BERT, round trip delay measurement, error performance analysis: G.821,<br />
G.826, G.828, G.829, M.2100,M.2101 and ANSI. Autoconfig functionality for<br />
automatic traffic detection, line rate, structure and mapping. Offline Viewer<br />
SW provides result analysis and report generation.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.
DATA & TELECOMMUNICATIONS<br />
PDH/SDH <strong>Analysers</strong> cont’d.<br />
Acterna ANT 5 Access Tester<br />
ACT,ANT-5 - STM16 MY<br />
Smallest and lightest test solution for interfaces from 1.544Mbps up to<br />
2.5Gbps. Optical testing at dual wave lengths at STM-1, STM-4, and STM-16.<br />
Electrical testing at DS1/E1/E3/DS3/E4 and STM-1 interfaces. Full analysis of<br />
concatenated mappings with SDH signals VC-4-4C, VC-4-16C. In-depth PDH<br />
analysis with Sabit generation and flexible MUX/DEMUX test configuration.<br />
Optical power measurement capability for easy detection of physical layer<br />
integrity. ATM analysis for service verification of ATM and 3G/UMTS networks<br />
testing new ATM services carried over PDH, SDH – ECLNRZ port enables<br />
nonintrusive direct monitoring of optical networks.<br />
JDSU/Acterna ANT 20 SDH/PDH Analyser<br />
JDSU,ANT20 (3465) AU<br />
Interfaces for PDH data streams at 2, 8, 34, & 140Mbps,<br />
electrical and optical interfaces for SDH at STM1<br />
(155Mbps). Jitter and wander generators and analyser<br />
options are fitted. Internal PC with FDD for transferring<br />
results. Serial, parallel, keyboard and pen interfaces.<br />
JDSU EDT-135 E1 and Data Tester<br />
JDSU,EDT-135 (3450) AU<br />
ACT,EDT-135 MY<br />
Field service tester for commissioning,<br />
maintenance and troubleshooting of E1<br />
PCM2Mbps and V.11/RS-442, V.24/RS-232,<br />
V.35,V.36/RS-449, EIA-530 data circuits<br />
operating at 50bps to 2Mbps. Provides framed<br />
& unframed monitoring, end-to-end testing, drop<br />
& insert, channel associated signalling; error & alarm analysis, S bit, NFAS<br />
& NMFAS monitoring & generation. Round trip delay measurement, G.821,<br />
G.826 & M.2100 quality of service measurements. Signal level measurement<br />
& primary multiplexer testing.<br />
Acterna MTS 8000/T-BERD Transport<br />
Module<br />
ACT,MTS8000 MY<br />
Multirate interface for PDH-DS1/DS3/<br />
E1/E3/E4,STS-1 OC-3/12/48/48, STM-<br />
1e/1/4/16 and interface for OC-192 STM-<br />
64 with the ability to monitor down to the<br />
STS-1 level inside of any supported optical<br />
rate. Used for verifying and qualifying the performance of SDH and Gigabit<br />
ethernet, telecommunications networks. Electrical and optical interfaces at<br />
rates 1310/1550nm). Also supports the NewGen (ethernet over Sonet/SDH)<br />
and able to perform RFC2544. Ethernet IP testing with 10/100/100Mbps<br />
electrical RJ-45 Interfaces. Supports VLAN, Q-in-Q,VPLS,MPLS Tunnelling<br />
application. Comes with touch screen GUI operation. Measures optical power<br />
and frequency. Floppy drive installed.<br />
JDSU MTS8000 Transport Module<br />
JDSU,MTS8000 STM-64 (3499) AU<br />
MTS8000 and Transport Module. This instrument is<br />
used for verifying and qualifying the performance of<br />
PDH, SONET/SDH telecommunications networks<br />
up to 10Gb/s. Also supports the NewGen (ethernet<br />
over Sonet/SDH) and able to perform RFC2544,<br />
network connectivity, throughput, quality of service<br />
and SLAs.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
Download solutions on page 11.<br />
24<br />
PDH/SDH <strong>Analysers</strong> cont’d.<br />
JDSU SmartClass E1/Datacom Tester<br />
JDSU,SMARTCLASS (3440) AU/MY<br />
Handheld field tester for the installation and<br />
commissioning of E1 and Datacom services. Applications<br />
include (not limited to), G.703 - 2Mb/s testing, 2<br />
M (Bulk), n x 64kb/s BERT, audio monitoring (VF drop<br />
& insert),ABCD/Sa monitoring, alarms (defects) and<br />
errors (anomalies) insertion, round-trip delay, DTE / DTE<br />
emulation and monitor mode. Interfaces with X.21, V.24<br />
(RS-232), V.35, V.36 (RS-449), and EIA-530.<br />
JDSU SmartClass Ethernet Optical Package<br />
JDSU,CSC-ETHTR-P2 MY<br />
SmartClass ethernet offers a unique, economical combination of featurespecific<br />
functionality, while providing an easy-to-use, cost-effective ethernet<br />
solution for physical layer cable testing, layer 2 and layer 3 traffic generation,<br />
and full RFC-2544 testing. Rugged and battery-operated. It is configurable<br />
as either a far-end loopback device only or a full RFC-2544 compliant traffic<br />
generator.<br />
Sunrise SunLite E1 Tester<br />
SUN,SUNLITE E1 MY<br />
World’s smallest 2Mbps telecom network tester. Performs and stores a<br />
variety of vital tests. Bright LED indicators provide immediate circuit status,<br />
and internal speaker/microphones provide talk and listen capabilities. <strong>Power</strong><br />
options include charger with two AA rechargeable batteries. 2.048Mbps<br />
transmit, receive and external clock. Bit error rate testing (ITU-T G.821).<br />
ITU-T G.826, M.2100 analysis.<br />
DSL/POTS Test Set<br />
www.techrentals.com.au<br />
VeEX VePAL TX130/e+<br />
VEE,TX130 MY<br />
Offers a single, multifunctional access network<br />
diagnostic tool. Equipped with PDH/DSn and Datacom.<br />
Performs traditional ITU-T/ANSI transmission tests<br />
required by large telcos and wireless/mobile operators,<br />
Datacom tests for networks operating “V” type interfaces.<br />
Designed for field engineers that need an easy-to-use,<br />
handheld and battery-powered field unit. To simplify and<br />
ensure rapid testing, the unit auto-configures itself to the<br />
signal detected, minimizing operator involvement.<br />
Line and DSL Test Set<br />
FLU,990DSL 2/2+ (3470) AU<br />
CopperPro broad range Plain Old Telephone<br />
Services (POTS) troubleshooting, fault location and line<br />
qualification capabilities. Includes Wideband/TDR option<br />
which adds high frequency transmission testing and<br />
qualification functions for services like ADSL 2/2+, VDSL,<br />
HDSL, HDSL2 & 4, ISDN, T1, E1 and DDS. TDR feature<br />
adds precise fault location and analysis. Includes TN2100<br />
remote terminator.<br />
Light Sources & <strong>Power</strong> Meters<br />
EXFO PPM-350B-EG PON <strong>Power</strong> Meter<br />
EXFO,PPM350B MY<br />
OptimiSed for FTTx E & GPON. PPM350B has 10 user-definable<br />
threshold sets, each set consisting of three wavelengths (1310, 1490 and<br />
1550 nm) having their own pass/warning/fail analysis features. Simultaneous<br />
measurement and display of all PON signals voice, data and video.
www.techrentals.com.au<br />
Light Sources & <strong>Power</strong> Meters<br />
cont’d.<br />
EXFO PON/FTTx <strong>Power</strong> Meter & Inspection Probe<br />
EXF,PPM352_FIP400 (3370) AU<br />
Kit includes PPM-352B-EG-ER optimized for FTTx E<br />
& GPON & FIP-400 inspection probe with handheld<br />
display. PPM352 has 10 user-definable threshold sets, as<br />
well as pass/warning/fail analysis features. Simultaneous<br />
measurement and display of all PON signals voice, data and<br />
video.<br />
Fluke FTK1000 Multimode Fibre<br />
Optic Light Source & Meter<br />
FLU,FTK1000 (3365) AU<br />
Light source is multimode 850nm and 1300nm.<br />
<strong>Power</strong> meter has 850/1300nm multimode and<br />
1310/1550nm single mode. Manage results and<br />
print reports via <strong>Power</strong> meter memory, PC and<br />
supplied software.<br />
Fluke FTK150 Optical Fibre<br />
Light Source/Meter<br />
FLU,FTK150 (3366) AU<br />
Fibre test kit. Light source is multimode 850nm and<br />
1300nm. <strong>Power</strong> meter has calibrated measurements<br />
at 850/1300nm multimode and 1310/1550nm single<br />
mode. +3dBm to -55dBm measurement range with<br />
0.01dB resolution. Manage results and print reports<br />
via <strong>Power</strong> meter memory, PC and supplied software.<br />
Supplied with various connectors and patch leads.<br />
Fluke Single Mode 1310/1550nm Laser Source<br />
FLU,LS-13101550 (3368) AU<br />
Single mode 1310/1550 dual laser source. O/P power -10dBm. Compatible with<br />
any single mode power meter.<br />
JDSU/Acterna OLA-55 Single Mode Optical<br />
Attenuator<br />
ACT,OLA-55 MY<br />
Adjustable wavelength from 1260 to 1650nm (1nm<br />
increments). Calibrated wavelengths 1310nm, 1550nm<br />
& 1625nm. Maximum permitted level =23dBm. Optical<br />
Interface: FC-PC.<br />
JDSU OLSP-55<br />
(BN 2279/01)<br />
Optical Laser Source<br />
JDSU,OLS-55 MY<br />
Operates on dual wavelength of 1310nm and 1550nm.<br />
Output power is from -7 to 0 dBm. Optical Interface: FC-<br />
PC.<br />
JDSU Single Mode OLS<br />
OLP-35 Light Source &<br />
<strong>Power</strong> Meter<br />
JDSU,OLS-OLP 35 (3361) AU<br />
Light source (OLS-35) and power meter (OLP-35)<br />
fibre optic test set for single mode applications 1310<br />
and 1550nm. OLS-35 has interchangeable FC, SC<br />
and LC adapters and -7dBm power output. OLP-<br />
35 has universal 2.5 and 1.25mm connectors, auto<br />
wavelength detection, internal data storage and report<br />
software included.<br />
25<br />
DATA & TELECOMMUNICATIONS<br />
Light Sources & <strong>Power</strong> Meters<br />
cont’d.<br />
Kingfisher 73410 2 Way<br />
Loss Test Set with ORL<br />
KIN,KI73410_LTS (3358) AU<br />
Two-way insertion and Return Loss Test Sets for 1310,<br />
1550 and 1625nm APC. Performs bi-directional loss<br />
measurements simultaneously. LTS are used to test<br />
cabling losses and single operator pass / fail operation in<br />
a PON type environment is easily achieved. Average fibre<br />
optic link loss and ORL from each end is automatically displayed in real time<br />
on both instruments, at multiple wavelengths via a single fibre. Applications<br />
include fibre optic attenuation, system power, ORL and Fibre Characterisation.<br />
Kingfisher KI78010<br />
Single Mode APC LS and<br />
KI7600 PM<br />
KIN,KI78010-7600 (3360) A U<br />
Light source (KI78010) and power meter (KI7600) optical<br />
fibre test set for single mode network and DWDM testing<br />
at 1310, 1550 and 1625nm. LS (KI78010) has Angled SC,<br />
FC and ST interchangeable connectors. PM (KI7600) with InGaAs detector<br />
has large user memory and flexible real-time PC reporting software. Autotest<br />
provides automatic multi wavelength loss testing. <strong>Power</strong> meter can be used for<br />
multiple single and multimode wavelengths.<br />
Kingfisher KI7822B- KI7600A SM Light<br />
Source & <strong>Power</strong> Meter<br />
KIN,KI7822B-7600A (3362) AU<br />
Light source (KI7822B) and <strong>Power</strong> meter (KI7600A)<br />
optical fibre test set for single mode applications (1310nm<br />
and 1550nm). <strong>Power</strong> meter has large user memory<br />
and flexible real-time PC reporting software. Autotest<br />
provides automatic multi wavelength loss testing. The meter displays mW,<br />
μW, nW, dB, dBm to 0.01dB resolution, with no range changing delays. <strong>Power</strong><br />
meter can be used for multiple single and multimode wavelengths. Laser<br />
output power 0dBm.<br />
Kingfisher KI7827 Single Mode APC LS<br />
and KI7600 PM<br />
KIN,KI7827-7600 (3364) AU<br />
L light source (KI7827) and power meter (KI7600) optical<br />
fibre test set for single mode applications such as FTTH<br />
(1310, 1490 and 1550nm). LS (KI7827) has Angled SC,<br />
FC and ST interchangeable connectors. PM (KI7600)<br />
with InGaAs detector has large user memory and flexible real-time PC<br />
reporting software. Autotest provides automatic multi wavelength loss testing.<br />
<strong>Power</strong> meter can be used for multiple single and multimode wavelengths.<br />
Fusion Splicers<br />
Fitel S123M12 Ribbon Fusion<br />
Splicer<br />
FIT,S123M12 AU<br />
Can splice from 1 to a maximum of 12-ribbon fibre.<br />
Protection sleeve shrink time is 35 seconds for ribbon<br />
fibre sleeve, while splicing requires only 15 seconds for<br />
8 or 12 ribbon fibre allowing up to 160 splicing cycles<br />
(splicing/heating) by 2 battery packs installed in the<br />
main body.
DATA & TELECOMMUNICATIONS<br />
Fusion Splicers cont’d.<br />
Fitel S178 Fusion Splicer and S325 Cleaver<br />
FIT,S178_S325 (3325) AU<br />
S178 hand-held, core-alignment fusion splicer and<br />
S325 cleaver. Splicer provides typical losses of 0.02dB<br />
& 0.01dB on single & multimode fibre respectively. 7<br />
second splice time, built in heater and tension test. Can<br />
be operated from battery or AC source. Precision fibre<br />
cleaver can be used with single and multimode fibres and features a built in sharps<br />
collection bin which automatically stores fibre off-cuts.<br />
Fitel S325A Precision Fibre Cleaver<br />
FIT,S325A (3324) AU<br />
Can be used with precision splicers for single and multi<br />
mode fibres. Features a built in sharps collection bin which<br />
automatically stores fibre offcuts as each fibre is cleaved.<br />
Fitel Fusion Splicer & Cleaver Kit<br />
FIT,SPLICER-CLEAVER (3326) AU<br />
Contains the S177A splicer and S325A cleaver. Splicer<br />
provides typical losses of 0.02dB & 0.01dB on single<br />
& multimode fibre respectively. 9s splice time, built in<br />
heater & tension tester. Can be operated from battery<br />
or AC source. Precision fibre cleaver can be used with<br />
single & multimode fibres. Features a built in sharps<br />
collection bin which automatically stores fibre off-cuts.<br />
Fujikura FSM60S Splicer & CT30 Cleaver<br />
FUJ,FSM60S-CT30 (3328) AU/MY<br />
For splicing multimode & single mode optical fibre.<br />
Battery and mains operated. Features splice protection<br />
heater, detachable work table and arc free calibration<br />
system. Includes CT30 fibre cleaver.<br />
26<br />
OTDR, FC & Fibre Accessories<br />
See also LAN Cable Testers on page 22<br />
Anritsu CMA4000 Single Mode OTDR<br />
ANR,CMA4000SM MY<br />
Includes mainframe and 1310/1550nm and 1625nm (38/40 & 39dB) single mode<br />
module (module part number TD-14M25003 Model 4453M). Instrument had built<br />
in FDD and supplied with SC/PC, FC/PC, and ST/PC connectors.<br />
Anritsu CMA 4500 Single &<br />
Multimode 5/25dB OTDR<br />
ANR,CMA4500SM-MM (3338) AU<br />
Single mode and multimode OTDR. Includes<br />
wavelengths multimode 850/1300nm (24/26dB)<br />
and single mode 1310/1550 (35dB). Single mode<br />
port is SC/APC. Ethernet, USB connectivity, 20GB<br />
HD and PS2 ports. Touch screen and hard key<br />
interfaces.<br />
Anritsu CMA 5000 Single Mode<br />
43/45dB OTDR<br />
ANR,CMA5000SM-45 (3342) AU<br />
Single mode OTDR with SC/APC (angled) adaptor.<br />
1310/1550/1625 Dynamic range 43/45/43dB. +20<br />
dBm Meter and Light Source and VFL (Visual<br />
Fault Locator). OTDR has built in CD-R/W and<br />
20GB hard drive. Dedicated touch screen and hard key user interfaces. Mains<br />
and battery operation, battery life >3 hours. 10/100MB Ethernet port for network<br />
connectivity. USB ports.<br />
Accelerate Performance. Upgrade to Digital Now!<br />
Bluetooth Technology<br />
Now Available<br />
for MotoTRBO<br />
The next generation professional two way radio communications solution is here.<br />
With increased performance, superior voice quality and greater opportunities for you,<br />
Motorola’s new Professional Digital MotoTRBO range delivers:<br />
Versatility and ease of use<br />
Extended battery life<br />
Increased calling capacity<br />
Easy migration from<br />
analogue to digital<br />
Please contact TR Bearcom now to tailor a rental<br />
or sales solution to meet your needs.<br />
Check Out Our New<br />
Online Store<br />
www.trbearcom.com.au<br />
Integrated data applications<br />
A wide range of audio accessories including:<br />
remote speaker microphones,<br />
earpieces and light-weight headsets<br />
www.techrentals.com.au<br />
bearcom<br />
no1 in radio solutions<br />
www.trbearcom.com.au<br />
BS0349
www.techrentals.com.au<br />
OTDR, FC & Fibre Accessories<br />
cont’d.<br />
Anritsu MT9083B Access<br />
Master Single Mode<br />
ANR,MT9083B (3336) AU<br />
Complete testing of PON-based FTTx networks<br />
featuring up to 1x64 splits or single fibre runs.<br />
1310, 1550 and 1625nm wavelengths. Intelligent<br />
analysis software identifies problem splices, connectors and even macrobends.<br />
Dynamic range up to 42dB. Active fibre verification. Store up to 1,000 traces in<br />
internal memory and up to 30,000 via your USB device.<br />
Fibre Inspection Video Probe X 250 & 400<br />
Magnification<br />
FLU,FT650 (3348) AU<br />
Fibre inspection probe for use with Fluke Optifibre<br />
OTDR. Has switchable 250 and 400 times<br />
magnification.<br />
Fluke Optifibre Multimode OTDR<br />
FLU,OPTIFIBER-MM (3344) AU<br />
Short range multimode OTDR designed<br />
for testing, troubleshooting and certifying fibre optics<br />
at 850/1300nm, 62.5μm and 50μm (requires 50μm<br />
launch cable). Unit has an SC interface. Typically 3<br />
and 7Km range for 850 and 1300nm respectively,<br />
event dead zone from 0.5m and attenuation dead zone<br />
from 4.5m. Battery operated, 62.5μm launch lead and<br />
LinkWare download and reporting software included.<br />
Fluke Optifibre Single<br />
Mode OTDR<br />
FLU,OPTIFIBER-SM (3345) AU<br />
Single mode OTDR designed for testing,<br />
troubleshooting and certifying network fibre optics<br />
at 1310/1550. Equipment has SC interface and VFL.<br />
Typically, 60Km range for 1310/1550nm, event dead<br />
zone 1m and attenuation dead zone 8m. Battery<br />
operated, launch lead and LinkWare download and<br />
reporting software included.<br />
Fluke Optifibre Single Mode OTDR Module<br />
FLU,OPTIFIBER-SM-MOD (3346) A U<br />
1310/1550nm with SC connectors. Attenuation dead zone<br />
1310/1550nm: 10.5m typical, 15m max. Event dead zone 1310/1550nm: 2.5m<br />
typical, 3m max. Maximum distance 10km. For use with Optifibre OTDR<br />
mainframe, launch lead included.<br />
RENTAL PURCHASE OPTION<br />
27<br />
DATA & TELECOMMUNICATIONS<br />
OTDR, FC & Fibre Accessories<br />
cont’d.<br />
JDSU Fibre Inspection-Capture Probe<br />
JDSU,FIBER_INSPECT (3340) AU<br />
Handheld display, dual magnification (200/400x) probe<br />
and USB adaptor for fibre end-face image analysis and<br />
capture. Includes software and various probe tips<br />
JDSU ODM Optical Dispersion Measurement System<br />
JDSU,MTS8000-ODM (3399) AU<br />
An Optical Dispersion Measurement system combines chromatic dispersion (CD),<br />
polarization mode dispersion (PMD) and attenuation profile (AP) measurements<br />
for fibre characterisation of new technologies, such as CWDM/DWDM with<br />
ROADM and high speed 10GigE, 10Gbps and 40Gbps+ networks. Mainframe<br />
included. Requires separate light source.<br />
Fibre Optic Launch Cables & Patch<br />
Leads<br />
Launch Fibre Multimode 50μm 100m<br />
FIB,LAUNCH MM 50UM (3380) AU<br />
100 metres of 50μm OM3 fibre terminated with SC<br />
connectors. A launch fibre enables an OTDR to<br />
measure the loss of the first connector and adapts a<br />
62.5μm OTDR to a 50μm network.<br />
Launch Fibre Multimode 62.5μm 300m<br />
FIB,LAUNCH MM 62.5UM (3382) AU<br />
300 meter SC multimode 62.5μm launch fibre.<br />
Launch Fibre Single Mode 9μm<br />
FIB,LAUNCH SM 9UM (3378) AU<br />
Single mode 9μm SC launch fibre.<br />
Microwave Link <strong>Analysers</strong><br />
Anritsu ME538 MLA TX & RX Microwave Link Analyser<br />
ANR,ME538M (3485) AU<br />
Measures group delay, modulator/demodulator linearity & sensitivity,<br />
differential gain & phase, IF/BB amplitude response, IF/BB return loss,<br />
frequency spectrum & deviation, am to pm conversion coefficient, power, gain<br />
attenuation and DC characteristics. Features: LED display, autorange CRT,<br />
push button parameter selection and remote monitoring. 70/140MHz bands:<br />
83.333, 250, 500kHz & 2.4, 3.58, 4.43, 5.6, 8.2, 12.39MHz.<br />
Our rental with purchase option scheme is available to approved business customers.<br />
Generally the rates quoted on the rental purchase option are based on a 12 month rental period<br />
after which you may purchase the equipment by paying an amount equal to month’s rental.<br />
However these plans can often be tailored to suit your particular timeframe requirements.<br />
<br />
take advantage of this option. If you have any questions about this scheme or the type of equipment<br />
that would apply please call our technical representatives to discuss your requirements.
www.techrentals.com.au<br />
Cable & Pipe Tracers & Fault Locators<br />
Electrical Testers<br />
PAT Testers & RCD Testers<br />
Micro-Ohm Meters & Earth Testers<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong><br />
AC Electrical Chart <strong>Recorders</strong><br />
Current Clamps Probes & Accessories<br />
Insulation Testers & Meggers to 20kV<br />
Oil, Hipot & VLF Testers above 20kV<br />
<strong>Power</strong> Transformer Testers<br />
Current Injectors<br />
Protection Relay Testing Systems<br />
AC Sources/Inverters/Generators<br />
<strong>Power</strong> Transformers<br />
<strong>Power</strong> Line Conditioners/UPS<br />
Battery Management Systems<br />
Cable & Pipe Tracers<br />
& Fault Locators<br />
See also Ground Penetrating Radar on page 67<br />
See also Oil, Hipot & VLF testers above 20kV on page 39 & 40<br />
See also Underground Services Location on page 66 & 67<br />
CScope CATXDSGV-KIT Cable and Pipe Locator<br />
CSC,CATXDSGV-KIT (3664) AU/MY<br />
Cable location tool. Includes 33kHz generator with<br />
touch button controls and LCD, XD receiver/locator<br />
with 33kHz, power or radio modes. Direct connection<br />
cable, stake and 75mm tong set. The transmitter<br />
can operate with direct connection, tongs or<br />
induction. Will also determine cable depth, range<br />
0.2m to 3m. It will operate with the Radiodetection<br />
33kHz sondes.<br />
Fluke Cable Locator<br />
FLU,2042 (3625) AU<br />
General purpose cable locator. Ideal for tracing<br />
cables in walls and underground, locating fuses/<br />
breakers on final circuits and locating interruptions<br />
and short-circuits in cables and electrical floor<br />
heating systems. Can also be used for tracing<br />
metallic water and heating pipes. Supplied as<br />
a complete kit comprising of a transmitter and<br />
receiver in a purpose-made carry case. The<br />
receiver also incorporates a torch function for<br />
working in dimly lit locations.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
29<br />
Cable & Pipe Tracers<br />
& Fault Locators cont’d.<br />
Megger MPP1002 Cable Fault<br />
Pinpoint Locator<br />
MEG,MPP1002-FAULT PP (3626) AU<br />
Pinpoints faults in shielded and direct buried<br />
primary cables via a single Geophone or dual<br />
Geophone probe. Stand-alone unit (without<br />
probes) measures electromagnetic surge<br />
and supplies the amplitude of that surge which aids in finding the fault. The<br />
versions can successfully detect both the electromagnetic and acoustic<br />
pulses emitted from an arcing fault when it is surged. Can be used with any<br />
Megger PFL <strong>Power</strong> Cable Fault Locating system (or) any surge generator.<br />
Fault detection up to 23m away and extended battery life, ballistic pulse<br />
scale provides thump magnitude and surge period, background interference<br />
elimination via selectable acoustic frequency band.<br />
Megger TDR1000 TDR Cable Fault Locator<br />
MEG,TDR1000 (3636) AU<br />
For cable consisting of 2 insulated metallic elements, one of which may be the<br />
armouring or screen of the cable. Internal matching networks to allow testing<br />
of 25, 50, 75 & 100 cables. Can be matched to the cable using the balance<br />
control allowing long lengths of cable to be easily tested and faults close to the<br />
instrument to be seen. Propagation velocity value can be similarly adjusted to<br />
match the cable, ensuring an accurate distance measurement can be directly<br />
read. Gain of the instrument is also variable, allowing more minor faults to<br />
be identified over length of the cable. Range 10m to 3km. Display: Large<br />
high-resolution backlit [LCD]. Batteries 6 x LR6 (AA), alkaline, NiCd or NiMH<br />
cells. 20/30h continuous use depending on backlight use. Dust and shower<br />
proof to IP54.<br />
Megger TDR20002RM Dual Channel TDR Cable Fault Locator<br />
MEG,TDR2000/2RM (3624) AU<br />
Range 20km at VF =0.90. Backlit display, dual cursor measurement, output<br />
pulse amplitude and width control. No blocking filter required for direct<br />
connection to live systems up to 300VAC. 15 memory trace storage, down<br />
loadable to PC via RS232C interface, software supplied. Ranges 50m, 100m,<br />
200m, 400m, 1km, 2km, 4km, 8 km & 16km. Resolution 0.1m up to 200m,<br />
0.2m up to 400m, 0.1% of range above 400m. Measurement accuracy 0.1%<br />
of range. Input impedance 120. Velocity factor variable from 0.300 to 0.999 in<br />
steps of 0.001. <strong>Power</strong>ed via rechargeable NiMH powerpack, charger supplied.<br />
Radiodetection Stethoscope Antenna for RAD,RD400 Series<br />
RAD,STETH-L (3634) AU<br />
Concave head fitted to flexible goose neck with handle. Length 480mm, head<br />
46mmØ. Frequency range 50Hz to 65kHz. Connect to any RD400 series<br />
Radio detection receiver fitted with accessory socket.<br />
Electrical Testers<br />
ELECTRICAL POWER<br />
See also Current Clamps Probes & Accessories on page 36-38<br />
AVO Penta-Plus DMM Analyser<br />
AVO,PENTA-PLUS-DMM (8470) AU<br />
Multifunction meter for measuring 1 & 3ph Volts AC,<br />
primary and secondary current, true and reactive power,<br />
amplitude and phase angle, and also frequency. Easily<br />
configured to measure the amplitude and phase angle<br />
between any 2 current or voltage inputs. Displayed simultaneously on a<br />
backlight graphic LCD screen. Internal memory records up to 60 test<br />
results. Logging via RS232C port. Parallel printer port. Voltage 0 to 650VAC,<br />
9 ranges with 0.1% resolution. Max 1kV. Current 0 to 100A AC in 11 ranges,<br />
with 0.1% resolution. Phase angle 0 to 360° with 0.1° resolution. <strong>Power</strong> true<br />
and reactive ±0 to 100kW & ±0 to 100kVAr. Frequency 45 to 65Hz. Timer 0<br />
to 999.999 seconds. Line or battery operated, 3h continuous operation on full<br />
charge.
ELECTRICAL POWER<br />
Electrical Testers cont’d.<br />
CATU C-8-36 Phasing Stick - Two Pole Phase<br />
Comparator for Indoor Use<br />
CAT,CL-8-36 PH STICK (8728) AU<br />
Detects differences in voltage between any two<br />
points of an installation indicated by LED’s. It also<br />
enables assessment of the order of magnitude<br />
of the residual voltage induced by nearby live lines or circuits, and thus<br />
differentiates it from the one provided directly from a high voltage source. Main<br />
features are wide range of voltages 2kV to 36kV, high luminosity, compact:<br />
620mm with probes dismounted, high dielectric quality insulating material. Two<br />
1.25m elements with removable probes, connected via a high-insulation lead,<br />
maximum use distance: 2.25m (with probe extenders). Operation testing: with<br />
a checking device.<br />
Hioki 3283 Clamp on Leak HiTester<br />
HIO,3283 CLAMP ON-LT (8804) AU<br />
Easily monitor leak current fluctuations. Wide bandwidth,<br />
5Hz to 15kHz (Waveform output), high-sensitivity with a full<br />
scale of 10mA (resolution:10μA). High-accuracy at ±1 %,<br />
True RMS measurement, analyser functions, for filtering<br />
and output signals. AC current range; 10mA to 200A AC, 5<br />
ranges (±1.0 % rdg. ±5 dgt. at 50 or 60Hz), and 200A AC,<br />
1 ranges (±1.5 % rdg. ±5 dgt. at 50 or 60Hz), effective value<br />
rectifier. Frequency characteristics (at AC current /voltage)<br />
40 to 2kHz.<br />
Martindale Phase Sequence & Continuity<br />
Indicator 100 to 600V, 50/60Hz<br />
MAR,PSCI424-585 (1233) AU<br />
Tester may be used, on 3ph circuits, to check the<br />
presence & sequence of the phases. Important<br />
on motor circuits as a phase reversal will cause a<br />
motors direction to reverse. Tester will give visual<br />
indication of loss of phase or an incorrect sequence.<br />
Tester is supplied in 2 forms - Probe style, the<br />
connection to the tester is via 3 insulated cables to<br />
3 fused test probes, 1 with an insulated crocodile<br />
clip. Plug style, a 16A, 4 pin, 3ph & earth, BS4343<br />
plug is fitted to the tester. Use as a socket tester prior to plugging in 3ph<br />
equipment. Testers supplied in a plastic wallet, with full instructions. Caution,<br />
the unit should be checked for correct operation using a known voltage before<br />
use.<br />
PAT Testers & RCD Testers<br />
Megger LTW335 Fault Loop<br />
Impedance Tester<br />
MEG,LTW335-FLIT (2612) AU<br />
2 Wire Non-tripping loop tester. 50V to 440V<br />
operation, 110V centre-tap loop testing,<br />
CATIV installation testing, AUTO start -<br />
<br />
<br />
Megger RCDT330 Residual Current Device Tester<br />
MEG,RCDT330 (2618) AU<br />
Tests standard, DC, selection and programmable RCDs. Ramp testing. Auto<br />
(remote) testing. Auto sequence test feature. 3ph safe. Enables testing on 110V<br />
centre tapped supplies. Performs 1/2I, 1xI & 50xI tests on RCDs rated at 10mA,<br />
30mA, 100mA, 300mA, 500mA & 1,000mA on general and selective (time<br />
delayed) RCDs. Weatherproof to IP54. USB interface for test results download.<br />
30<br />
www.techrentals.com.au<br />
PAT Testers & RCD Testers cont’d.<br />
Metrel IT3017- Installation<br />
Tester for Testing to AS/<br />
NZS3000<br />
MET,IT3017INSTALTEST (2610) AU<br />
Multifunction installation tester with<br />
measurement functions and Pass/Fail<br />
<br />
storing of test results for printing compliance test reports. In-built Australian<br />
measurements and Pass/Fail limits, and guarantees accountability and<br />
traceability with storing of test results. Simply conduct the test, press the<br />
Memory button to save the result and assign the result to a location, then<br />
download results to PC software and print-out compliance test reports with<br />
actual test results. Earth Continuity & Resistance, Insulation Resistance,<br />
Polarity, Correct Circuit Connections, Fault Loop Impedance and RCD<br />
Testing. “Auto-Sequence Test” mode further speeds up compliance testing<br />
and reporting.<br />
Metrel MI 2121 AUS Advanced RCD Tester<br />
MET,MI2121AUS (2620) AU<br />
<br />
Stores upto 1,000 tests. Interface RS232 Software. Fast<br />
testing of 10,30, 100, 300, 500, 1,000mA RCD’s both<br />
standard (I, II, III) and selective (IV) AC types. With 50%, 100%, 200% and<br />
500% nominal test current for all ranges. Sinusoidal trip current for reliable<br />
operation. Selectable phase angle 0 degree (positive) and 180 degree<br />
(negative). Measures RCD trip time and current, phase voltage to 470V.<br />
1,000 test result memory logging. Results download software.<br />
Seaward PAC 3760 Appliance Checker<br />
SEW,PAC3760 (2605) AU<br />
Performs the following tests in conformance to AS/<br />
<br />
tests, also leakage current tests for Class I & Class II<br />
appliances and leads (leakage current testing of<br />
appliances, which requires power to “switch” them on,<br />
<br />
pass/fail indication. Unique 3 button operation. Class I,<br />
class II and leakage current. Automatic test sequence<br />
senses an IEC or extension lead then performs a<br />
polarity test. Detects that the appliance under test is<br />
switched “On”. Earth bond test is set at 10A and is capable<br />
of fusing a poor earth.<br />
Seaward ProTag OPTIMA-300 Testing<br />
and Tagging System<br />
SEW,PT-300 (2603) AU<br />
Comprises the Seaward PrimeTest 300 appliance and<br />
RCD tester, ProTag Optima test tag printer and the BCS-<br />
Blue bar code scanner. Battery powered, weighs around<br />
<br />
for appliances and leads, and 30mA RCD tests. Operates<br />
as a handheld data logging device by recording any type<br />
of test, inspection or risk assessment with user defined<br />
inspection routines and an in-built library of measurement<br />
and engineering units for recording actual results.<br />
Trolley Suitable for SEW,XE3760PKIT+ Supernova PAT Tester<br />
SEW,TROLLEY-3760PKIT (2608) AU<br />
<br />
5 socket extension board socket 240V/10A, extension cable approximately<br />
25 meters, 2 elastic tie ropes and a plastic bin.
www.techrentals.com.au<br />
PAT Testers & RCD Testers cont’d.<br />
Seaward Supernova XE3760+<br />
PAT System with Printer and<br />
Scanner<br />
<br />
Includes results label/tag printer and barcode<br />
<br />
2001/2003 compliant tests, including class<br />
1 & class 2 leakage current 5mA/1mA, an<br />
earth conductor bond test up to 25A at 3V<br />
(approx. 100W) and 250VDC MOV insulation<br />
resistance tests. Stores 5,000 tests in internal memory by appliance ID,<br />
including test type, detailed results, test time & date,<br />
next test due date, site & location. Calibrated resolution better<br />
than the required 5% of full scale across all ranges as specified by<br />
the Standard. Full QWERTY keyboard, and bar code reader for input.<br />
Durable plastic adhesive test label/tags printed to attach to<br />
appliances and leads includes user ID (logo optional on request) and test<br />
barcode ID, saves transcription. Compatible with Seaward PATGuard plus<br />
software package.<br />
Micro-Ohm Meters & Earth Testers<br />
CHK LM05 Micro-Ohm Meter 10A<br />
CHK,LM05 (1262) AU/MY<br />
Operates from internal batteries or external power supply. Maximum test<br />
<br />
Includes power supply/charger, duplex helical test leads, length 2m.<br />
Fluke 1623 KIT GEO Earth Ground Tester<br />
FLU,1623-KIT (8435) AU<br />
Performs the following tests: 3 & 4-pole ‘Fall<br />
of Potential’ using stakes, 4-pole soil resistivity<br />
testing using stakes. Selective testing using<br />
1 clamp and stake. Stakeless testing using 2<br />
<br />
<br />
Fluke 1625 KIT GEO Earth Ground Tester<br />
FLU,1625-KIT (8434) AU<br />
Performs the following tests: 3 & 4-pole ‘Fall of Potential’ using stakes, 4-pole<br />
soil resistivity testing using stakes. Selective testing using 1 clamp and stake.<br />
<br />
Stakeless measurement range 0.001 to 199.9. Includes the capability AFC<br />
(Automatic Frequency Control), to reduce interference, calculates resistance<br />
at 50Hz and has settable limits to allow go/no go testing.<br />
Fluke 1630 Earth Ground Clamp<br />
FLU,1630-EARTH CLAMP (8443) AU<br />
Earth ground loop testing and continuity testing without breaking<br />
the circuit. Uses the stakeless testing method; eliminates<br />
the need to disconnect parallel ground rods and find suitable<br />
locations for placing auxiliary ground stakes. Performs earth<br />
ground loop tests in locations where it is not possible to use<br />
other techniques, including inside buildings or on power pylons.<br />
Fluke Clamp for Ground Loop Resistance<br />
around <strong>Power</strong> Pylons<br />
FLU,EI-162BN (8436) AU<br />
Selective clamp for ground loop resistance<br />
measurement around power pylons. Inner diameter<br />
of the clamp is 320mm. Includes the split core<br />
transformer and all necessary adapters/connections<br />
for the Fluke 1623 and Fluke 1625.<br />
31<br />
ELECTRICAL POWER<br />
Micro-Ohm Meters & Earth Testers<br />
cont’.<br />
Megger High Accuracy<br />
Configurable Diagnostic Earth<br />
Tester<br />
MEG,DET2/2 (8412) AU<br />
Provides a wide resistance range from<br />
<br />
complex grounding systems and for difficult<br />
<br />
control and advanced filtering simplify testing in environments with high levels<br />
of interference.<br />
Megger DE20C Digital Earth Test Clamp<br />
MEG,DET20C (8417) AU<br />
<br />
<br />
Automatic self calibration. Auto ranging. High and low alarms.<br />
Large memory. Download to Megger Download Manager.<br />
Measures earth resistance in installations such as buildings,<br />
pylons and RF transmitter sites. Use for the inspection and<br />
verification of lightning protection systems. Large jaw opening.<br />
Megger DET4TC2 Digital Earth<br />
Tester With Kit<br />
MEG,DET4TC2 MY<br />
<br />
voltage measurement from 1V to 100V and ground<br />
current from 1mA to 20A. Accurate results can be<br />
obtained in electrically noisy environments since it<br />
is capable of rejecting noise voltages of 40V peak to<br />
peak and the user can select different test frequencies to minimise the effect of<br />
interference. <strong>Power</strong>ed from 8 AA batteries. Supplied with ICLAMP augments<br />
the traditional fall-ofpotential measurement method with ART (Attached Rod<br />
Technique) which allows electrode testing without disconnection and also<br />
leakage current measurements down to 1mA. The VCLAMP enables true<br />
stakeless measurements to be made in situations where driving stakes is not<br />
practical.<br />
Megger DLRO10 Micro-Ohm Meter<br />
MEG,DLRO10 (1267) AU<br />
Self contained automatic micro-ohm meter, selecting the most suitable test<br />
<br />
seven ranges. Instrument is built into a strong, lightweight case. Light enough<br />
to be worn around the neck, small enough to be taken into areas which were<br />
previously too small to access. Uses a large, bright 4-1/2-digit LED display.<br />
Resolution: 0.1microhms. Battery: rechargeable NiMH, typical life 1,000 tests<br />
at full load.<br />
Megger DLRO10X Digital Low Resistance Ohm<br />
<br />
MEG,DLRO10X (1266) AU/MY<br />
Self contained automatic micro-ohm meter,<br />
selecting the most suitable test current, up<br />
to 10A DC to measure resistance from 0.1μ-<br />
2k in seven ranges. Real-time download of<br />
results on on-board storage for later review.<br />
Automatically detects continuity in potential<br />
and current connections. Visible warning of<br />
high voltages present at the terminals. Visible warning of current flowing<br />
in the test sample. Multiple operating modes including fully automatic.<br />
Alpha-numeric keypad for entering test notes. User selectable high and low<br />
limits. Autoranging with manual option.
ELECTRICAL POWER<br />
Micro-Ohm Meters & Earth Testers<br />
cont’d.<br />
Megger DLRO200 200A Micro-Ohm Meter<br />
MEG,DLRO200 (1265) AU<br />
Test currents from 10A to 200ADC. 0.1 microohm<br />
resolution. Weight 14.5kg On board memory for<br />
up to 300 test results and notes. RS232 download<br />
of stored results onto PC or printer.<br />
Megger DLRO600 Digital Micro-Ohm Meter - High current<br />
MEG,DLRO600 (1268) AU/MY<br />
<br />
currents from 10A to 600A subject to the load resistance and supply voltage.<br />
A large backlit liquid crystal display provides all the information needed to<br />
perform a test; all test parameters and measurement results are displayed.<br />
<br />
Accuracy: Voltage ±0.5% ± 0.1mV. Current ±0.5% ± 0.1A. Resistance:<br />
<br />
detail]. <strong>Power</strong> supply for: full output: 207 to 265V 50/60Hz with a load less than<br />
<br />
load]. Reduced output: Down to 100V 50/60Hz [refer to data sheet for detail].<br />
Test Current Range: 10A to 600A unsmoothed DC in 1A steps. Accuracy:<br />
±2% ±2A. Test Modes: Manual, Auto, Continuous. Test Time: 7 seconds<br />
normal /auto mode. Refreshed every 2 seconds in continuous mode. Voltmeter<br />
input impedance: >200kW. Data Transfer: Real time or batch download<br />
via RS232 using AVO Download Manager. Storage Capacity: 300 result sets.<br />
Megger DLRO Wind Turbine<br />
Lightning<br />
Protection Test Lead Set<br />
MEG,DLRO-100LEAD (1263) AU<br />
For Megger DLRO 10 series digital microohm<br />
meters. Specially designed for measuring<br />
resistance of lightning protection circuit between<br />
wind turbine blade tip and ground. Kelvin clip<br />
and hook ends on 100m cable reel. 5m DH2<br />
lead with duplex hand spikes and hook end.<br />
Megger DLRO lead set Current & Voltage Leads<br />
MEG,DLRO-LEADSET (1263) AU<br />
For Megger DLRO digital micro-ohm meters potential spike lead set x2 and<br />
current clip lead set x2. Leads are used to separate the C & P connections.<br />
This avoids the erroneously high readings taken due to a high resistance<br />
contact. Current clip lead set 2m (242041-7) and Potential Spike set 2m<br />
(242021-7).<br />
Megger LT330 Non-tripping Loop Tester, 3Ph Safe,<br />
1ph or ph-ph<br />
MEG,LT330 EN-AU (8445) AU<br />
Non-tripping loop tester. 3 phase safe, single or phase-phase loop testing. 2<br />
wire test (high current). Single phase loop testing. Phase - Phase loop testing.<br />
L-N-E polarity indicators. PFC display. Phase rotation indicator. Frequency<br />
<br />
storage & download via USB. IP54 weatherproof. IEC61010-1 300v CAT III.<br />
EN61557.<br />
T&R DSM200 200A Micro-Ohm Meter<br />
T&R,DSM200 (1264) AU<br />
<br />
with RS232 output. AC mains operation. Complete with 3m leads.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
32<br />
www.techrentals.com.au<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong><br />
See also Current Clamps Probes & Accessories on page 36-38<br />
CCI <strong>Power</strong>-Mate 15A Single Phase<br />
<strong>Power</strong>/Energy Measurements<br />
CCI,POWER-MATE 15A (8803) AU<br />
Can accurately measure and calculate power, volts, amps and<br />
energy being used by an electrical appliance. Also measures<br />
the greenhouse gas emission created by an appliance. Can<br />
determine the actual running cost, how much energy the<br />
appliance used in kilowatt-hours and how many kilograms of<br />
greenhouse gas emissions it produced all in hourly, yearly,<br />
quarterly and accumulated figures. Features an LED display for easy reading<br />
and high visibility at all times. 15 amp version - to a maximum continuous<br />
capacity of 15A, but readings are accurate to 18A and the cable is rated to<br />
15A. Provides a variety of measurements including: power in watts, voltage<br />
and current. Provides the minimum, maximum as well as instantaneous<br />
readings.<br />
CHK PM20 <strong>Power</strong> Quality<br />
Analyser/Logger<br />
CHK,PM20 MY<br />
Three phase, weatherproof IP65 field unit. Three voltage<br />
channels 63 to 440V (isolated). Four current<br />
channels 0 to 3kA RMS (3ph & neutral). Supplied with<br />
3 x 1kA clamp-on CTs (cable capacity 50mm), 3kA<br />
for large conductors and 500A for neutrals clamp-on<br />
CTs are available. Memory 4Mb. In-built 2 line LCD<br />
display. Records V, A, pf, f(Hz), kW, kVA, kVAr, THD, total energy and tariffs,<br />
high speed RMS waveform capture events outside preset limits (10ms intervals).<br />
Software provides graphs and summaries to PC. Download files while<br />
logging. RS232 interface. PC using Win 95, 98 or NT4 O/S, is required with the<br />
CHK POWERview software to configure this unit before operating.<br />
CHK Gridsense PM30 3 Phase<br />
<strong>Power</strong>monic <strong>Power</strong> Logger<br />
CHK,PM30 (8788) AU/MY<br />
Weatherproof IP65 field unit. Channels 3 voltage, 63<br />
to 440V (isolated), 4 current 0 to 3kA (3ph & neutral)<br />
RMS. Supplied with 3 x 1kA clamp-on CTs (cable<br />
capacity 50mm). Clamp-on CTs of 3kA, 1kA for large<br />
conductors and 500A & 100A for neutral conductor<br />
current measurement are available. Memory 4Mb.<br />
In-built 2 line LCD display. Records V, A, pf, f(Hz), kVA, kVAr, kW, harmonics,<br />
(THD and individual to 48th). Total energy, tariffs, max demands, transient<br />
and sub-cycle disturbances. Software provides graphs and summaries to PC.<br />
Download files while logging via RS232 interface. PC using Win 95, 98, NT4,<br />
2000, XP, O/S, is required with the CHK POWERview software to configure<br />
this unit before operating.<br />
CHK Gridsense PM30<br />
Plus 3 Phase <strong>Power</strong>monic Logger<br />
CHK,PM30PLUS (8778) AU/MY<br />
Weatherproof IP65 field unit. Channels: 3 Voltage,<br />
63 to 440V (isolated). 3 current 30 to 3,000A (3ph)<br />
rms. Supplied with 3 flexible 3,000A clamp-on CTs<br />
(flexible CT length 600mm and 190mmØ). (In addition,<br />
clamp-on CTs of 3,000A, 1,000A for large conductors<br />
and 500A and 100A for neutral conductor current<br />
measurement are available.) Memory: 4Mb. Inbuilt<br />
two line LCD display. Records: V, A, pf, f(Hz), kVA,<br />
kVAr, kW, harmonics, (THD and individual to 48th). Total energy, tariffs,<br />
maximum demands, transient and sub-cycle disturbances. Included software<br />
provides graphs and summaries to PC. Download files while logging RS-232<br />
interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required<br />
with the CHK POWERview software to configure this unit before operating.
AUSTRALIA’S LEADING CALIBRATION LABORATORY. ESTABLISHED 1989.<br />
Booking Calibration Service – Minimise downtime and<br />
optimise utilisation of your equipment<br />
TR VMS Booking Service<br />
To minimise downtime, TR VMS provide a Booking Service<br />
<br />
<br />
and arrange a date for the next available time slot.<br />
A quote will be provided stating that the equipment is to arrive<br />
<br />
done. Simply sign the acceptance of the quote and return.<br />
HyperCal Calibration Service - When your need is urgent<br />
You also have the choice of a Hypercal Calibration Service,<br />
for when the calibration is urgent, and your job will be “next<br />
on the bench” and in most cases with a one day turnaround.<br />
There is a surcharge for this service.<br />
Otherwise utilise the standard calibration service which may<br />
take 10 business days for calibration.<br />
Ask about out Mobile Calibration Laboratory.<br />
www.trvms.com.au<br />
Call now for all your calibration requirements.<br />
1300 790 480<br />
Locations in Brisbane and Sydney<br />
<br />
“The best service, at the best price,<br />
in the best time!”<br />
33<br />
Distributors of Honeywell<br />
Aerospace Zing Products.<br />
Used in vibration monitoring of both<br />
<br />
VM0072
ELECTRICAL POWER<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
CHK PM35 <strong>Power</strong> Quality<br />
Analyser/Logger<br />
CHK,PM35 (8788) MY<br />
<strong>Power</strong> logger and disturbance analyser. Weatherproof<br />
IP65 field unit. 3 Voltage (55 to 520VAC) and 4 current<br />
(0 to 3,000A) channels. Supplied with 4 flexible<br />
3,000A clamp-on CTs (flexible CT length 600mm<br />
and 190mmØ). Memory: 15Mb. Inbuilt two line LCD<br />
display. Records: V, A, pf, f(Hz), kVA, kVAr, kW,<br />
harmonics, (THD and individual to 48th ). Flicker (Pst & Plt), Total energy,<br />
tariffs, maximum demands, transient and sub-cycle disturbances. Included<br />
software provides graphs and summaries to PC. Download files while logging.<br />
High speed USB interface. A PC using Windows 95, 98, NT4, WIN2000 or<br />
XP (Vista in compatability mode)O/S, is required with the software to configure<br />
this unit before operating.<br />
CHK Gridsense PM40 <strong>Power</strong> Quality<br />
Analyser<br />
CHK,PM40PQA (8779) AU<br />
Weatherproof IP65 field unit. Channels: 3 Voltage,<br />
63 to 440V (isolated). 4 current 0 to 3,000A (3ph<br />
and neutral) RMS. Supplied with 4 flexible 3,000A<br />
clamp-on CTs (flexible CT length 600mm and Diameter<br />
190mm). Memory: 15Mb. Inbuilt Graphic 128x64 bits<br />
LCD display, 7 rows x 20 characters. Records: V, A,<br />
pf, f(Hz), kVA, kVAr, kW, harmonics, Inter harmonics,<br />
voltage and current imbalance (THD and individual<br />
to 48th ) and Flicker. Total energy, tariffs, maximum<br />
demands, and transient and sub-cycle disturbances. Included software<br />
provides graphs and summaries to PC. Download files while logging USB<br />
interface. A PC using Windows 95, 98, NT4, WIN2000 or XP O/S, is required<br />
with the CHK <strong>Power</strong>View software to configure this unit before operating.<br />
CHK PM45 <strong>Power</strong> Quality Analyser<br />
CHK,PM45 (8779) AU<br />
Suitable for low voltage investigations,<br />
power profiling and load studies, harmonic analysis,<br />
power factor studies & flicker and imbalance<br />
monitoring. Features IEC61010 Cat IV 600V safety<br />
certificate, weatherproof IP65 case, 4 channel<br />
voltage and 4 channels current. Supplied with 4 x<br />
Flexi F3000-6 clamps. VA,B & C 0 to 600VAC VGnd<br />
0 to 60VAC, Current input 0 to 3,000A.<br />
Dranetz-BMI <strong>Power</strong> Guide 4400<br />
DRA-BMI,PG4400 (8700) AU<br />
Provides the full range of<br />
measurements include V, I, W, VA, VAR,<br />
TPF, DPF, demand, energy, harmonics &<br />
inter-harmonics, THD, harmonics spectrum<br />
<br />
factor, K factor, transformer de-rating etc.<br />
<br />
range 30/300/3,000A AC only. Can be extended to different ranges of<br />
measurement AC/DC by selecting appropriate current clamps. Has the full<br />
range of arithmetic, vector and sequence parameters to evaluate distorted and<br />
<br />
active parameter can trigger logging. Voltage & current disturbances. DRA-<br />
BMI,PG4400 analysers can be used for power quality measurements, current<br />
inrush fault recording long term monitoring and continuous logging at 1s intervals.<br />
DRA-BMI,PG4400 is Class A compliant with IEC Standard 61000-4-30,<br />
AS61000-4-7 and AS61000-4-15.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
34<br />
www.techrentals.com.au<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
Dranetz-BMI <strong>Power</strong> Xplorer PX5<br />
DRA-BMI,PX5 (8701) AU<br />
Provides the full range of measurements<br />
include V, I, W, VA, VAR, TPF, DPF, Demand,<br />
Energy, Harmonics & Inter-harmonics, THD,<br />
Harmonics spectrum (V, I, W) to the 63rd,<br />
Flicker (Pst, Plt), Crest factor, K factor, Transformer de-rating etc. Min/Max/<br />
Avg values are determined in ½ cycle RMS steps. Complete with A/C Flexible<br />
Current Clamp DRA-BMI,RR3035A/24, Current Range:- 30/300/3,000A AC<br />
only. Can be extended to mentioned different ranges of measurement both<br />
AC/DC by selecting appropriate current clamps. High-speed transient capture<br />
(1MHz sampling rate) and full range of arithmetic, vector and sequence<br />
parameters to evaluate distorted and un-balanced loads as defined in IEEE<br />
1459. Exceeding high/low limits of any active parameter can trigger logging.<br />
Voltage and current disturbances can be triggered by peak value, wave-shape<br />
change and cycle-by-cycle RMS value change. Pre-event and post-event<br />
waveform capture cycles are user adjustable. Voltage and current channels<br />
can be cross-triggered. Can be used for power quality measurements,<br />
current inrush (cycle-by-cycle current logging), fault recording (cycle-bycycle<br />
voltage logging), long term monitoring and continuous logging at 1s<br />
intervals. The four differential voltages and current channels can also be<br />
used independently. Class A compliant with IEC Standard 61000-4-30 ‘<strong>Power</strong><br />
Quality Measurement Methods’ (also AS DR04066), AS61000-4-7 ‘Harmonic<br />
& Inter-harmonic Measurements’ and AS61000-4-15 ‘Flicker-meter’. All data<br />
is collected at 256 samples/cycle/channel.<br />
Fluke VR1710 Single-Phase Voltage<br />
Quality Recorder<br />
FLU,VR1710 (8734) AU<br />
Single phase power quality analyser. Records RMS,<br />
transients, flicker & harmonics up to the 32nd. Selectable<br />
logging periods from 1s to 20min. Provides continuous<br />
recording with no gaps. Includes software for download,<br />
analysis and automatic reporting.<br />
Hioki 2332-20 RPMS SmartSite Remote<br />
<strong>Power</strong> Measurement System<br />
HIO,2332-20RPMS (8715) AU<br />
For multi-channel power recording 1ph 2 wire up to 6 circuits or 1ph 3<br />
wire & 3ph 3 wire up to 3 circuits. Provides via a PC, management of<br />
measurement data to support energy and environmental management.<br />
Modulated measurement units take advantage of a variety of infrastructure<br />
to collect measurement data. Use as a stand alone logger and for remote<br />
monitoring. Use as a PC measurement logger keeps measuring and continuously<br />
saves the data. Measurement modules comes with memory and clock.<br />
Build a customised and remote measuring system by utilizing existing data<br />
network. Modules for temperature, humidity, instrumentation and pulse, power<br />
module for multiple circuits. Large internal memory. Communication module<br />
with built-in real-time clock tracks - resolution 1s. Air Module for constructing<br />
SS wireless systems.<br />
Hioki 3169-21 Clamp-On<br />
<br />
500 Amps CT’s<br />
HIO,3169-21 CT500AMP (8718) AU<br />
Measurement of single-phase to<br />
three-phase 4-wire circuits with a single<br />
unit. In addition to measuring standard parameters such voltage, current,<br />
power, power factor, and integrated values, can simultaneously perform<br />
demand measurements required for carrying out power management and<br />
energy-saving measures, as well as harmonic measurements. Features:<br />
Measure up to 3-phase, 3-wire system (displays voltage and current for<br />
three lines), Measure up to four single-phase, 2-wire systems, up to 500A<br />
range, compact and light weight, power recording for individual waveforms,<br />
simultaneousrecording of demand values and harmonics. RS-232C interface<br />
for PC communications, supplied with Hioki 9625 <strong>Power</strong> Measurement<br />
Support Software for data analysis. Includes 4 x Hioki 9667 500A CTs.
www.techrentals.com.au<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
Hioki 3169-21 Clamp-On <strong>Power</strong><br />
<br />
HIO,3169-21CT1000AMP (8719) AU<br />
Measure up to 3-phase, 3-wire system (displays voltage and current for<br />
three lines), Measure up to four single-phase, 2-wire systems, 5A to 1,000A<br />
range. Compact and light weight, PC card data storage, power recording for<br />
individual waveforms, simultaneous recording of demand values and<br />
harmonics. Complete with RS232C interface for PC communications.<br />
Supplied with Hioki 9625 <strong>Power</strong> Measurement Support Software for data<br />
analysis. Includes 4 x Hioki 9669 1,000A CTs.<br />
Hioki 3169-21 Clamp-On <strong>Power</strong> HiTester<br />
HIO,3169-21CLAMPONPT (8717) AU<br />
Measure up to 3-phase, 3-wire system (displays voltage and<br />
current for three lines), Measure up to four single-phase, 2-wire systems, 5A<br />
to 5,000A range. Compact and light weight, PC card data storage, power<br />
recording for individual waveforms, simultaneous recording of demand values<br />
and harmonics. Complete with RS232C interface for PC communications.<br />
Supplied with Hioki 9625 <strong>Power</strong> Measurement Support Software for data<br />
analysis. Includes 4 x Flexible Hioki 9667 CTs (500A, 5,000A switchable).<br />
Hioki 3196 3 Phase<br />
<strong>Power</strong> Quality Analyser<br />
HIO,3196-PQA (8775) AU/MY<br />
High speed (0.5μs 2MHz) field unit. Channels 4 voltage,<br />
150 to 600V RMS 4 ranges (isolated), 4 current<br />
0 to 5kA (3ph and neutral) RMS 2 ranges. Supplied with 4 x 5kA flexible clampon<br />
CTs (length 945mm). Memory 13Mb internal, 512Mb compact flash card.<br />
Display internal high resolution colour LCD. Records V, A, pf, f(Hz), kVA, kVAr,<br />
kW, harmonics, (THD and individual to 50th order) flicker IEC6100-4-15. Total<br />
energy, tariffs, max demands, transient and sub-cycle disturbances. Software<br />
provides graphs and summaries to PC. Interfaces RS232 and 10base ethernet.<br />
PW3198 <strong>Power</strong> Quality Analyser<br />
NEW<br />
Cat IV 600V<br />
Class A<br />
IR5001 Temperature<br />
Humidity Logger<br />
ELECTRICAL POWER<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
Hioki 3196 <strong>Power</strong> Quality<br />
Analyser with Clamp-on CT<br />
1,000 Amps<br />
HIO,3196PQA-CT1000A (8774) AU<br />
Measures power factor, sags, swells,<br />
flicker, transients, harmonics to the 50th,<br />
high frequency transient, detection and<br />
waveform display, 4 current and 4V channels.<br />
Measurement ranges: Voltage ch1 to ch3: 150 to 600VAC RMS-3 ranges,<br />
ch4: 60 to 600VAC RMS-4 ranges, or 60/600VDC-2 range. Supplied with<br />
4 x 1,000A clamp on CT’s HIOKI 9669. Measurement method: Transient<br />
overvoltage: 2Ms/sec, Harmonic wave: 2048 point (10 cycle @ 50Hz, or 12<br />
cycle @ 60Hz), other effective value: 256 point/one cycle.<br />
Hioki 3197 <strong>Power</strong> Quality<br />
<br />
Clamp-on CTs<br />
HIO,3197PQA (8779) AU<br />
Comprehensive portable PQA. Monitor for:<br />
inrush current, voltage swell, voltage dips,<br />
transient over-voltage and interruptions.<br />
Measure and record: power and power factor,<br />
active/reactive energy, demand, load changes (with graph display), voltage and<br />
current. Measures Impulsive voltage quality: transient over voltage (Impulse).<br />
RMS voltage quality: voltage swell, voltage dips, voltage interruption. <strong>Power</strong><br />
quality: frequency, voltage, current, current peak, active/reactive/apparent<br />
power, power factor (displaced power factor). Three phase quality: voltage<br />
unbalance ratio, current unbalance ratio. Harmonic quality (up to 50th order) :<br />
harmonic voltage, harmonic current, harmonic power, harmonic voltage/current<br />
phase angle, total harmonic voltage distortion, total harmonic current distortion<br />
(THD-F, THD-R).<br />
QUALITY PRODUCTS<br />
QUALITY RESULTS<br />
<strong>Power</strong> Analysis<br />
<br />
<br />
<br />
Data Logging<br />
<br />
<br />
<br />
<strong>Power</strong> Parameters Pty Ltd<br />
83 Northern Road, Heidelberg West, Vic 3081<br />
www.parameters.com.au power@parameters.com.au<br />
Freecall: 1800 623 350 Freefax: 1800 067 263<br />
3169-20 <strong>Power</strong> Analyser<br />
8870-20 Memory HiCorder
ELECTRICAL POWER<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
Hioki 3332 <strong>Power</strong> HiTester Suitable for Standby <strong>Power</strong> Single Phase<br />
HIO,3332 POWERTESTER (8776) AU<br />
Suitable for measuring very low effective power, for stand -by mode of home<br />
equipment. Ultra high-sensitive measurement. Use to measure effective<br />
power of equipment in standby mode: Current 1mA with 0.1μA resolution.<br />
Wide Measurement range, up 5A direct input and auto range facilities are<br />
available. Suitable for single-phase/two wire power measurement. Voltage<br />
measuring ranges from 15V to 600V six ranges, <strong>Power</strong> 15mW to 30kW 90<br />
ranges. Integration range 0 to ± 999999MAh/MWh, integration time up to<br />
10,000 hours. RS232C interface. Other features includes measurement of<br />
inrush current during device start-up, measurement of standby power under<br />
1W, precise calculations of minute stand by power, when 150V/1mA range is<br />
selected, integration from ± 000.000mWh can be performed. Low numbers/<br />
units are automatically switched to a 6 digit display, allowing measurement in<br />
high resolution.<br />
LEM Topas 1000<br />
<strong>Power</strong> Network Analyser<br />
LEM,TOPAS1000 (8762) AU<br />
Measures all relevant parameters in one<br />
measurement system. Inputs (isolated) voltage<br />
4 channels, 200mV to 1kV, current 4 channels,<br />
supplied with 4 x 0 to 10A, 10 to 100A AC<br />
clamp-on CTs and 4 x (unit powered) 0 to 3kA LEM-Flex current sensors.<br />
Can be configured for 8 voltage channels. Measuring functions RMS, V(U)<br />
voltage imbalance, positive, negative & zero phase sequence, phasor (vector)<br />
diagrams, amps (I)a, pf, kVA, kVAr, f(Hz), energy, on-line oscilloscope, power<br />
and multimeter, harmonics (by power/direction, magnitude & phase), interharmonics,<br />
THD, flicker, transients (100kHz to 10MHz), will capture events<br />
from 0.1μs in duration. Software configured manual or auto trigger levels,<br />
ethernet or serial interface, memory >540Mb/HDD.<br />
Megger MMC850 Multi/Single Core AC<br />
Clampmeter - 200 Amps<br />
MEG,MMC850CLAMPMETER (8776) AU<br />
Multi/Single Core AC. Clampmeter single, two or three core<br />
cable measurement. Flat or round section cables; no need<br />
to split wires. Measures up to 200A on single-core, 100A on<br />
multi-core cables. Cable centralising clamp, backlit display,<br />
50Hz and 60Hz supplies, IEC 1010-2-032, CAT III 600V<br />
safety protection.<br />
Megger SK-MDP3 Distribution<br />
Profiler 1000Amps/35kV<br />
MEG,SK-MDP3 (8727) AU<br />
Records currents up to 1,000A, plus 200A over-range.<br />
Waveform capture and harmonic analysis up to the 32nd<br />
order. <strong>Power</strong> factor/power and relative voltage RMS<br />
magnitude, overhead line spring attachment, accurate data<br />
capture via advanced MDP software, Lightweight battery<br />
operated, weather resistant. Easy plug-in for quick data<br />
retrieval.<br />
<br />
MET,MX2040 (8811) AU<br />
Measures A, V, Hz, kW, kVA, kVAR, kWH, PF and resistance.<br />
Ranges 200A & 2kA, 600V & 1kV, 20, 200kW & 2MW &<br />
kWH. Scale length 3,000. 1 & 3ph operation. Motor rotation<br />
indication. Peak, min, max, average, RMS, and crest factor<br />
indication. Peak response time 1μs. Analogue output option<br />
fitted giving dynamic signals and calculated parameters<br />
(energy, etc). Jaw opening 55mm for 22 x 64 bars.<br />
36<br />
<strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> cont’d.<br />
Metrosonics PF-1-F Overhead Profiler<br />
MET,PF-1-F (8726) AU<br />
Distribution line profilers for current measurement on power lines. Logs current<br />
consumption to internal memory. Set of 3 profilers with one display module.<br />
Windows software included. Current range 5 to 1,000A. Resolution 1A.<br />
Accuracy 1.5% ±5A. Conductor voltage to 69kV nominal. Sample rate 1s to<br />
10min. Memory 64k readings. Data storage modes: stop when full or wrap<br />
around. Data retention after low battery shutdown 30d. Min conductor spacing<br />
600mm.<br />
AC Electrical Chart <strong>Recorders</strong><br />
Hioki 9132 Clip-on AC Current Transducer<br />
HIO,9132 (8604) AU<br />
Ranges 20 to 1kA fs. Short term overload capability 2kA. Output 0.2VAC. For<br />
use with Hioki 8800 series recorders, for current waveform recording.<br />
Current Clamp Probes & Accessories<br />
See also Electrical Testers on page 29 & 30<br />
See also <strong>Power</strong> <strong>Analysers</strong> & <strong>Recorders</strong> on page 32-36<br />
www.techrentals.com.au<br />
CHK 3 Phase Converter for CTs 1A Input to 200mA Output<br />
CHK,CK1 (8791) AU<br />
Adaptor for CTs with 1A secondary outputs, this unit suits CHK,PM30/20.<br />
CHK 3 Phase Converter for CTs 5A Input to 200mA Output<br />
CHK,CK5 (8785) AU<br />
Adaptor for CTs with 5A secondary outputs, unit suits CHK,PM30/20.<br />
CHK CR100 Clamp-on CT<br />
CHK,CR100 (8782) AU/MY<br />
Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to<br />
measure neutral current. Accuracy Class 1.<br />
CHK CR500 Clamp-on 500 CT<br />
CHK,CR500 (8789) AU<br />
Jaws 43mmØ inside. Use with CHK,PM20 or PM30 for use as fourth CT to<br />
measure neutral current. Accuracy Class 1.<br />
CHK CT1000L Large 1kA Primary Clamp-on CT<br />
CHK,CT1000L (8796) AU<br />
Large 123 x 35mm 1kA primary clamp-on CT for CHK,PM20/30.<br />
CHK CT3000L Large 3kA Primary Clamp-on CT<br />
CHK,CT3000L (8790) AU<br />
Large 123 x 35mm 3kA primary clamp-on CT for CHK,PM20/30.<br />
Dranetz Communications Adapter<br />
- Fibre to Ethernet with Node Link<br />
Software<br />
DRA-BMI,CAF-ETHERNET (8709) AU<br />
Communications Adapter-Fibre to Ethernet<br />
with NodeLink Software and Moxa<br />
Networking Software for the following<br />
Dranetz-BMI Models: DRA-BMI,PX5, DRA-<br />
BMI, PX5-400, DRA-BMI,PG4400.
www.techrentals.com.au<br />
Current Clamp Probes &<br />
Accessories cont’d.<br />
Dranetz View Math Driver Software (Add On)<br />
DRA-BMI,DVMDS (8703) AU<br />
In 4 essential areas, the Math Package will improve measurements:- Rescue<br />
Kit. Ever hooked up a probe the wrong way? May be forgotten to check if<br />
the actual time in your instrument is running correctly? Or could you have<br />
possibly forgotten to set the correct K-factors? The Math Package helps<br />
you to correct these errors, re-calculate parameters from available waveform<br />
data, invert waveforms and much more. Improve Measurements /<br />
Reports. Calculate additional parameters for your Multi-DAQ TASK Card,<br />
fault-recorder/inrush mode measurements, with the math driver the following<br />
additional trends will be created for Multi-DAQ data files: V RMS, Watts,<br />
VAR’s, VA, True PF, V thd (%fundamental), I thd (abs current) Voltage<br />
Frequency (for internal trigg) and Net Totals V RMS, Amps, W, VAR & VA.<br />
Generate More parameters from waveform data. Showing Displacement<br />
<strong>Power</strong> Factor (DPF) instead of K-factor. Rename inputs. Energy ON/OFF<br />
peak calculations. Advanced mathematical expressions and formulas can be<br />
used to plot additional user-defined channels within both the time-plot chart<br />
and the waveform chart. Advanced analysis, watt harmonics, symmetrical<br />
components, etc.<br />
Dranetz AC/DC Current Clamp 3 to 1500A RMS<br />
DRA-BMI,PR1500 (8708) AU<br />
Max conductor size is 52mmØ. Current clamp<br />
is suitable for any of Dranetz-BMI models<br />
DRA-BMI,PG4400, DRA-BMI,PX5. Current<br />
clamp/probe is very useful for current<br />
measurement through CT current transformer. CT<br />
Ratio can be selected on the Dranetz-BMI abovementioned<br />
models.<br />
<br />
Current Clamp 60/600/6,000A<br />
DRA-BMI,PR6035A/36 (8704) AU<br />
Set of 3 flexible current clamps 60/600/6,000A<br />
RMS, max conductor size/length of clamp is 36”.<br />
Current clamps are suitable for any of Dranetz-<br />
BMI Models. DRA-BMI,PG4400/DRA-BMI,PX5. Current clamp/probe is very<br />
useful for current measurement through CT current transformer. CT Ratio can<br />
be selected on the Dranetz-BMI above-mentioned models.<br />
Dranetz TR2021 Current Clamp 1 to 30A 48Hz to 10kHz<br />
DRA-BMI,TR2021 (8706) AU<br />
Set of 3 current clamps 1 to 30A RMS, 48Hz to 10kHz. Max conductor<br />
size 12mmØ. Current clamps are suitable for DRA-BMI,PG4400, DRA-<br />
BMI,PX5 and DRA-BMI,PX5-400 models and are very useful for current<br />
management through CT current transformer. CT Ratio can be selected on the<br />
above-mentioned models.<br />
Current Clamp Probe 0 to 1A RMS<br />
DRA-BMI,TR2501 ( 8705) AU<br />
Set of 4 current clamp/probes, range 0.05 to 1.2A RMS. Max conductor<br />
size 12mm dia. Suitable for power quality analysers DRA-BMI,PG4400,<br />
DRA-BMI,PX5 and DRA-BMI,PX5-400. For current measurement through<br />
CT current Transformer. CT Ratio can be selected on the above mentioned<br />
models.<br />
Dranetz TR2510 Current Clamp Probe 0 to 10A RMS<br />
DRA-BMI,TR2510 (8705) AU<br />
Set of 3 current clamp/probes, range 0 to 10A RMS. Max conductor size 12mm<br />
dia. Suitable for power quality analysers DRA-BMI,PG4400, DRA-BMI,PX5<br />
and DRA-BMI,PX5-400. For current measurement through CT current<br />
Transformer. CT Ratio can be selected on the above mentioned models.<br />
37<br />
Current Clamp Probes &<br />
Accessories cont’d.<br />
ELECTRICAL POWER<br />
Fluke True RMS Clamp Meter 1000A<br />
<br />
FLU,376 (8733) AU<br />
Includes a flexible current probe. will record Min Max and<br />
Average. Measures AC Volts(1000V), DC Volts (1000V),<br />
Resistance, Capacitance (1uF to 1000uF) & Continuity.<br />
Fluke i1010 AC/DC Current Clamp 1,000A DC<br />
and 600A AC<br />
FLU,I1010AC/DC CLAMP (8737) AU<br />
Battery-powered Hall-effect probe measures 1A to<br />
1,000A. 1mV/Amp output guarantees easy reading<br />
on your meter. Take accurate current readings without<br />
breaking the circuit.<br />
Fluke i410 AC/DC Current Clamp 400A AC/DC<br />
FLU,I410 AC/DC CLAMP (8738) AU<br />
Battery-powered Hall-effect probe measures 1A to 400A. 1mV/Amp output<br />
guarantees easy reading on your meter. Take accurate current readings<br />
without breaking the circuit. Maximum conductor Ø 32mm. CAT III 600V<br />
safety rating.<br />
Hioki AC/DC Clamp on Meter with Analog Output 20/200A<br />
HIO,3284 (8756) AU<br />
Can also measure volts, ranges 30V, 300V, 600V AC/DC. Frequency ranges<br />
10Hz, 100Hz, 1,000Hz. Display LCD, counts max 2,500 current, 3,750<br />
voltage, 1,250 frequency. Output voltage 1V for 2,000 count on full scale for<br />
each current range, can select Rec rms output, response time about 250ms<br />
rise time, fall about 500ms. Select Mon for waveform output. 1V is produced<br />
for 1,000 count on full scale frequency range. Output not available for voltage<br />
measurements. Supplied with signal output cord, 4mm to BNC convertor,<br />
carry case and AC adaptor. Note: Can be powered with internal 9V battery or<br />
AC adaptor. (AC adaptor not supplied.)<br />
Hioki 3285 AC/DC Clamp-on Meter<br />
with Analog Output<br />
HIO,3285 (8755) AU<br />
Ranges 200A/2kA AC/DC. Measure volts, ranges 30V,<br />
300V & 600V AC/DC. Frequency ranges 10Hz, 100Hz<br />
& 1kHz. Display LCD, counts max 2,500 current, 3,750<br />
voltage and 1,250 frequency. Output voltage 1V for<br />
2,000 count fs for each current range, can select Rec<br />
RMS output, response time about 250ms rise time, fall<br />
about 500ms. Waveform output. 1V is produced for 1,000<br />
count on full scale frequency range. Output not available<br />
for voltage measurements. Supplied with signal output<br />
cord, 4mm to BNC convertor, carry case and AC adaptor.<br />
<strong>Power</strong>ed with internal 9V battery or AC adaptor. (AC<br />
adaptor not supplied) adaptor.<br />
Hioki 3290 Clamp-On AC/DC HiTester<br />
HIO,3290 MY<br />
Current Measurement at DC and from 1Hz<br />
AC to 1,000Hz. Current Clamp Hioki 9693<br />
Clamp-on AC/DC sensor ranges: 20, 200 &<br />
2,000A, jaw opening 55mm.<br />
Hioki 9660 Clamp-on 100A AC CT<br />
HIO,9660CT100A (8740) AU<br />
Rated primary current 100A AC. Amplitude accuracy: ±0.5% rdg. ±0.2%fs<br />
(at 45 to 66Hz). 66Hz-5kHz ±1% or less. Max circuit voltage 300V RMS/<br />
insulated wire. Core jaw: 15mmØ. Size: 46w x 21d x 135hmm, cord length 3m.
ELECTRICAL POWER<br />
Current Clamp Probes &<br />
Accessories cont’d.<br />
Hioki 9661 CCT-500A Clamp-On<br />
Sensors 500A, 500mVAC Output<br />
HIO,9661 CCT-500A (8742) AU<br />
500A rated, 500mVAC f.s. output,<br />
core jaw dia 46mmØ. Designed with<br />
a safety barrier to protect the user<br />
from being in direct contact with live<br />
conductors and completely meet all CE<br />
marking requirements. Basic specifications: Rated input current 500A AC,<br />
rated output current 0.5VAC, accuracy (at 45 to 66Hz), amplitude: ±0.5%<br />
rdg ±0.2% f.s. Full scale (f.s.) is the 3196 range value, phase: ±0.5° or less,<br />
frequency characteristics 66Hz to 5kHz (±1% or less from accuracy), max<br />
allowable input continuous 550A RMS (45 to 66Hz), max circuit voltage<br />
600VAC RMS (insulated wire), core jaw Ø46mm, dimensions, mass 77mm W<br />
x 151mm H x 42mm D, 360g, cord length 3m.<br />
Hioki 9661-01 CCT-500A Clamp-on<br />
Sensors<br />
HIO,9661-01 CCT-500A (8742) AU<br />
500A rated, 500mVAC fs output, jaw 46mmØ.<br />
Rated input current 500A AC, rated output<br />
current 0.5VAC, accuracy (at 45 to 66Hz).<br />
Amplitude ±0.5%rdg, ±0.2%f.s., fs is the 3196<br />
range value, phase ±0.5° or less, frequency<br />
characteristics 66Hz to 5 kHz (±1%), max. Allowable input continuous<br />
550A RMS (45 to 66Hz), max circuit voltage 600VAC RMS (insulated wire).<br />
Dimensions 77mm W x 151mm H x 42mm D, cord 3m. Suitable for Hioki<br />
models: 3196PQA, 3197PQA, 3169-20CLAMPONPT, 2331-20RPMS,<br />
8715-01, any data logger/scope which takes up to 1.7mVAC input.<br />
<br />
HIO,9667-FCT-5000A (8792) AU<br />
10Hz to 20kHz, 500/5,000A rated, 500mV AC f.s. output, 254mm diameter<br />
maximum. Designed with a safety barrier to protect the user from being<br />
in direct contact with live conductors and completely meet all CE marking<br />
requirements. Basic specifications: Rated input current 500A AC, 5,000A<br />
AC, rated output current 0.5V AC, accuracy (at 45 to 66Hz). Amplitude:<br />
±2% rdg ±1.2mV, full scale (f.s.) is the 3196 range value, phase: ±1° or less,<br />
frequency characteristics 10Hz to 20kHz, maximum allowable input<br />
continuous 1,0000A rms (45 to 66Hz), maximum circuit voltage 1,000V AC rms<br />
(insulated wire), core jaw dia Ø254mm(10in). Dimensions: mass 254mmW x<br />
86mmH x 30mmD, 140g. Sensor length: 910 mm. Suitable for the following<br />
Hioki Models: HIO,3196PQA, HIO,3197PQA, HIO,3169-20CLAMPONPT,<br />
HIO,2331-20RPMS, HIO,2331-20RPMS, HIO,8715-01, any data logger/scope<br />
which takes up to 1.7mV AC input.<br />
Hioki 9669-CCT-1000A Clamp-on<br />
Sensors<br />
HIO,9669-CCT-1000A (8744) AU<br />
Jaw 55mmØ, 80mm x 20mm busbar.<br />
Rated input current 1,000A AC, rated output<br />
current 0.5VAC, accuracy (at 45 to<br />
66Hz) amplitude ±1% rdg, ±0.01% fs, fs is<br />
the 3196 range value, phase ±1° or less,<br />
frequency characteristics 66Hz to 5kHz<br />
(±1%), max. Allowable input continuous 1,000A RMS (45 to 66Hz), max circuit<br />
voltage 600VAC RMS (insulated wire). Dimensions 99.5mm W x 188mm<br />
H x 42mm D, cord 3m. Suitable for Hioki models 3196PQA, 3197PQA,<br />
3169-20CLAMPONPT, 2331-20RPMS, 8715-01, any data logger/scope which<br />
takes up to 1.7mVAC input.<br />
38<br />
Current Clamp Probes &<br />
Accessories cont’d.<br />
www.techrentals.com.au<br />
Hioki 9670 Thermal Printer, Input RS232C,<br />
suitable for most of the Hioki Series<br />
HIO,9670 PRINTER (8759) AU<br />
Operates from a computer or the other host system.<br />
Battery operated. Prints 16 x 16 dots and 24 x 24 dots<br />
(as well as Japanese characters JIS Level I and II), and<br />
can print bar codes. Provides various settings such as<br />
enlarged-character printing. Graphics can be printed<br />
using bit images. Suitable for most of the Hioki Series.<br />
Hioki 9694 Clamp-on CT 5A<br />
HIO,9694CT5A (8741) AU<br />
Rated primary current 5A AC. Amplitude accuracy ±0.5% rdg. ±0.2% fs (at 45<br />
to 66Hz), 66Hz to 5kHz ±1% or less. Max circuit voltage 300V RMS/insulated<br />
wire. Core jaw 15mmØ. Size mm: 46w × 21d × 135h, cord length 3m.<br />
LEM Current Probe 10A to 1A Suitable for LEM,TOPAS 1000 PQA<br />
LEM,CURRENT PROBE10A (8763) AU<br />
10A to 1A suitable for LEM Topas 1000 power quality analyser.<br />
LEM FLEXII 30, 300 & 3,000A Transducer<br />
LEM,LEM-FLEXII (8638) AU<br />
Flexible wrap-around AC current transducer. Length 600mm. Ranges 30,<br />
300A & 3kA. Frequency response 1 to 20kHz. Accuracy 1%. Phase error<br />
0.5°. Output 3V RMS @ full scale. Requires 3 units for 3ph. Designed for<br />
multimeters and oscilloscopes (4mm banana plug or BNC connectors). Other<br />
instruments may be attached providing the correct adaptor/transducer and<br />
connection is available. Operates for 100h from 2 x 9V batteries.<br />
Universal Technic P75.3C DC/AC Amp Clamp<br />
UNI,P75-3C (8712) AU<br />
Max current 7,500A DC & AC peak. Bandwidth 1kHz. Min range 1kA.<br />
Accuracy at 75A 10% of reading. FS accuracy 2% of reading. Max bus size<br />
122 x 54mm or 100 x 64mm. Max cable size 83mm. Battery 9V, life 100h.<br />
Output sockets 4mm. DC current gives DC output, AC current gives AC<br />
output, 4kA range 0.5mV per amp, 7.5kA range 0.2mV per A.<br />
Universal Technic Clamp-On AC/DC Current<br />
Probe 4000/7500A<br />
UNI,P75-3C HYBRID-DP (8713) AU<br />
Ranges 7,500A/1.5V & 4,000A/2V with hybrid<br />
power fitted for battery and external power supply,<br />
3V operation. Safety sockets 4mm. Clamp is<br />
suitable for use with any instrument with an input<br />
range of 2VAC or DC, and an input impedance<br />
<br />
oscilloscopes, and power quality analysers.<br />
Insulation Testers & Meggers to 20kV<br />
Fluke 1587 Insulation Multimeter<br />
FLU,1587 MY<br />
<br />
50V, 100V, 250V, 500V, 1,000V Multimeter: Voltage 1mV to 1,000VAC/DC,<br />
<br />
1nF to 9999microF, frequency 0.01Hz to 99.99kHz.<br />
Fluke 1653 Electrical Installation Tester<br />
FLU,1653 MY<br />
Tester verify the safety of electrical installations, according to IEC 60364, HD<br />
384 standards. Functions available: voltage and frequency measurement,<br />
insulation resistance testing, continuity testing, loop impedance, RCD tripping<br />
time, RCD tripping current, Earth resistance and Phase sequence.
www.techrentals.com.au<br />
Insulation Testers & Meggers<br />
to 20kV cont’d.<br />
<br />
HIO,3454-51-3 (8404) AU<br />
Continuity function with 200mA and 3 range voltage selectable 250V, 500V<br />
& 1kV. Digital display, auto-discharge, live-wire warning, safety system for<br />
high voltage measurement, sliding cover. Backlit LCD. Checks ground wire<br />
continuity with a short circuit current of 200mA. Ground continuity testing<br />
<br />
@ 1kV. Other functions:- insulation and low resistance mode - comparator,<br />
measurement value hold, insulation resistance mode - auto discharge,<br />
insulation and AC voltage mode. Maximum rated working voltage 600VAC.<br />
Hioki 3455 High Voltage<br />
Insulation Tester<br />
HIO,3455HVIT-5kV (8403) AU/MY<br />
PI and DAR function to check insulation quality and<br />
step voltage test to detect for signs of deterioration.<br />
Generates test voltages from 250V to 5kV in commonly<br />
used presets of 250V, 500V, 1kV, 2.5kV & 5kV, or set<br />
to desired level by increments or decrements of 25V<br />
or 100V. Insulation diagnoses for automatic calculation and indication of PI<br />
(Polarisation index) and DAR (Dielectric absorption ratio), step voltage testing<br />
and temperature correction. Large memory stores up to 100 manual records<br />
and a logging function for 10 data (360 times). Stored data with date and time<br />
may be displayed on the LCD or down-loaded.<br />
Megger 10-01 10kV Insulation Tester<br />
MEG,10-01-10kV (8424) AU<br />
Compact, Microprocessor controlled<br />
high voltage DC Insulation tester. Test voltage:<br />
500V to 10kV.<br />
Megger BM21 500V/1/2/5kV Insulation Test Set<br />
MEG,BM21 MY<br />
<br />
<br />
measurement. Capacitance measurement at end of test. Automatic discharge<br />
of capacitance. In-built test timer. Insulation burn mode - short circuit current<br />
1mA nominal. Battery life 8h, in-built charger for charging from mains or<br />
12VDC.<br />
Megger FT6/12 Ionisation, Leakage & Breakdown Tester<br />
MEG,FT6/12 (8433) AU<br />
AC ranges 0 to 2kV, 0 to 6kV, DC ranges 0 to 4kV, 0 to 12kV. Output currents<br />
7.4mA, 8.9mA AC & 2.1mA, 2.5mA DC. Breakdown and flashover indication<br />
by latching indicator for periods exceeding 1ms. Current threshold 100μA to<br />
1mA. Ionisation indication by internal speaker. Meter indication of AC, DC and<br />
AC capacitive currents. Complete with probes.<br />
Megger MIT1020 Diagnostic 10kV<br />
Insulation Resistance Tester<br />
MEG,MIT1020-10kV DIT (8425) AU<br />
Backlit display, variable test voltage from 50 to<br />
10,000V, Automatic IR, PI, DAR, SV and DD tests,<br />
<br />
results. IEEE 43-2000 recommends the use of 10kV for<br />
motor windings rated above 12kV. Protection rating of<br />
IP54. Mains or battery powered.<br />
Megger S1-1052 High Current<br />
Insulation Resistance Tester 10kV<br />
MEG,S1-1052 10kV-DIT (8413) AU<br />
High output current 5mA for fast charging of capacitive loads. Testing<br />
up to 10kV, mains or battery powered, digital/analogue backlit display,<br />
variable test voltage from 50 to 10,000V, automatic IR, PI, DAR, SV and DD<br />
<br />
39<br />
ELECTRICAL POWER<br />
Insulation Testers & Meggers to<br />
20kV cont’d.<br />
Megger S1-552 High Current<br />
Insulation Resistance Tester 5kV<br />
MEG,S1-552 5kVDIT (8415) AU<br />
High output current 5mA for fast charging of capacitive<br />
loads. Testing up to 5kV, mains or battery powered,<br />
digital/analogue backlit display, variable test voltage<br />
from 50 to 5,000V, automatic IR, PI, DAR, SV and DD tests. Measures to<br />
<br />
Oil, Hipot & VFL Testers above 20kV<br />
See also Cable & Pipe Tracers & Fault Locators on page 29<br />
Baur DAP75 Insulating Oil Tester<br />
BAU,DPA75 (4626) AU<br />
Fully automatic insulation oil tester. Output voltage 0 to 75kV RMS. Selectable<br />
programmes to international standards. Integral printer. RS232 interface. One<br />
transit case on wheels. Total weight is 35kgs.<br />
High Voltage Inc PFT303 Test Set<br />
30kV/50Hz AC Hi Pot Tester<br />
HIV,PFT303 (8401) AU<br />
Rated 1kVA into resistive load, 3kVA into<br />
capacitive load. Duty cycle at 3kVA ½h on 2h off,<br />
at 2kVA 1h on 1h off. Tests the integrity of items<br />
including insulating materials, isophase bus duct,<br />
switchgear, transformers, vacuum bottles & interrupters, vacuum switches,<br />
automatic circuit reclosers, bushings, fuses, arrestors, circuit breakers,<br />
transformers, capacitors, motor and generator windings.<br />
High Voltage Inc PFT503, 50kV AC Test Set<br />
HIV,PFT503 (8400) AU<br />
Rated 1kVA into resistive load, 3kVA into capacitive load. Duty cycle at 3kVA<br />
½h on 2h off, at 2kVA 1h on 1h off.<br />
High Voltage Inc Very Low Frequency<br />
(VLF) 6022 60kV Hi-pot Test Set<br />
HIV,VLF6022 (8461) AU<br />
For field testing of AC high/medium voltage<br />
cables, bushings, and insulators. Input<br />
230V, 50Hz, 6A peak, 2.5A average.<br />
Output sinusoidal, 0 to 60kV AC peak,<br />
frequency 0.1, 0.05 & 0.02Hz. Duty continuous. Test load capacitance 1.1μF<br />
(approx 3kms of cable at 0.1Hz), 2.2μF (approx 9kms of cable at 0.05Hz)<br />
& 5.5μF (approx 13kms of cable at 0.02Hz). Display 0 to 60 peak kV.<br />
Interconnect cable length 3m, control unit to HV transformer. RG8/U output<br />
cable length 3m. Shorting stick braid 6m. HV tank and control units shipped in<br />
travel cases weighing 70 & 40kg respectively.<br />
High Voltage Inc VLF-90CM 90kV Test Set<br />
HIV,VLF90 (8462) AU<br />
Very low frequency (VLF-90CM) AC hipot test set<br />
with 90kVAC peak output, is suitable for testing<br />
cables up to 50kV. High load capacity enables it<br />
to test up to approx 7 miles of cable, depending<br />
on type. Includes a charging current and load<br />
capacitance meter, test dwell timer, and polarity<br />
indicating lights. Output voltage and frequency, sinusoidal 0 to 90kVAC<br />
peak & selectable, 0.1, 0.05, 0.02Hz. Test frequency and rated loads with<br />
approximate cable lengths are: -0.1Hz/0.55μF 1,673m of cable, 0.05Hz/1.1μF<br />
3,353m of cable, 0.02Hz/2.2μF 6,706m of cable. Kilovoltmeter scaled 0 to<br />
100kVAC peak, ammeter scaled 0 to 100mA AC and 0-6μF load capacitance.<br />
Weight of the unit 167kgs. HV Cable output is 6m flexible, shielded x-ray with<br />
alligator clamp, inter connect cable length 3m, shorting stick 6m lead with clip.
ELECTRICAL POWER<br />
Oil, Hipot & VFL Testers above 20kV<br />
cont’d.<br />
HV Diagnostics HVA TD60 Portable TanDelta<br />
Measurement System<br />
HVD,HVA TD60 (4620) AU<br />
Tan Delta or <strong>Power</strong> Factor tester used to determine the power<br />
factor of cables, transformers, capacitors, rotating machines<br />
and other switchgear. This test allows the detection of insulation<br />
defects before they fail inservice. Used in conjunction with the<br />
HVD,HVA60 VLF tester.<br />
HV Diagnostics HVA30 30kV-15mA<br />
DC/VLF High Voltage Insulation<br />
DielectricsTest Set<br />
HVD,HVA30-DC/VLF (4622) AU<br />
VLF (0.1Hz), DC (±), cable fault conditioning<br />
(burning), and sheath/jacket testing modes all<br />
included. 0.1Hz & 0.02Hz. For solid dielectric<br />
cables such as XLPE and EPR. Fully automatic<br />
or manual cable test sequences complying<br />
with International Standards/Guides such as IEEE 400.2, VDE<br />
0296, CENELEC, etc. True symmetrical sinusoidal, load independent,<br />
output waveform across the full load range. Real-time display of<br />
actual output waveform. Easy to use, menu guided. Large output load<br />
capability (up to 5μF). Automatic and integrated load capacitance<br />
measurement with optimum frequency selection. Data storage for review or<br />
download. Short circuited protected.<br />
HV Diagnostics HVA60 60kV-50mA DC/<br />
VLF High Voltage<br />
Insulation Dielectrics Test Set<br />
HVD,HVA60-DC/VLF (4624) AU<br />
True sine wave low frequency output. 0.1Hz &<br />
0.02Hz. For VLF, DC and jacket/sheath testing. Fault<br />
conditioning capability. Test result storage capability.<br />
Short circuit protection. Complies with CENELEC,<br />
IEEE 400.2, VDE 0296 and other international standards. Manual or fully<br />
automatic test sequence selection. Real time display of actual output<br />
waveform. High voltage power source suitable for testing electrical plant<br />
including cables: XLPE, PE, EPR, PILC etc, capacitors, switchgear,<br />
transformers, rotating machines, insulators and bushings.<br />
Megger OTS80PB Transformer<br />
Oil Tester Insulation<br />
Dielectrics Test Set<br />
MEG,OTS80PB (4628) AU<br />
Test voltage 80kV max at 61.8Hz. Fully automatic<br />
operation. Rechargeable batteries. RS232C<br />
interface.<br />
<br />
PHE,BK130 (8406) AU<br />
Tests elevating boom as well as the work platform and linings<br />
to ANSI A92.2 draft standard. Can also he used in many other<br />
Hipot applications that require the sort of voltage and current<br />
this instrument is capable of. Can supply 0 to 130kVAC @<br />
50mA and 0 to 35kVAC at 171mA. The whole system is built<br />
into a trolley cart for ease of use. Measurement accuracy 1%<br />
FS for 10 to 100% of range.<br />
T&R kV30-40, 30kV AC Hipot Test Set<br />
T&R,kV30-40 (8402) AU<br />
0 to 30kV, max output 40mA with a duty cycle of 5min<br />
on & 15min off. Max continuous current 20mA. Overload<br />
<br />
operated safety features.<br />
40<br />
<strong>Power</strong> Transformer Testers<br />
www.techrentals.com.au<br />
Biddle 550005 Turns Ratio Test Set<br />
BID,550005 (8421) AU<br />
Single phase (can be used on 3ph individual phase windings). Turns ratio<br />
0.001 to 129.999. Exciting current 0 to 1A. Accuracy 0.1%. Hand cranked<br />
operation.<br />
Megger 3Ph Transformer Tester<br />
MEG,TTR320-47 (8422) AU<br />
3 phase transformer turns ratio test set.<br />
Automatic operation, graphical user interface.<br />
Stores upto 100,000 data sets.<br />
Omicron CPC 100 PTS for CTs/VTs/<strong>Power</strong><br />
Transformer<br />
OMI,CPC100PTS (4606) AU<br />
Allows multifunctional primary test system for substation<br />
commissioning and maintenance. Automated testing<br />
of power transformers, CTs, VTs, resistance testing,<br />
and more. Providing up to 800A (or 2,000A with current<br />
booster) and 2,000V and comes complete with an<br />
integrated PC. Its software routines test a wide range of substation equipment,<br />
and automatically creates customizable reports. Total weight: 112kg including<br />
all the accessories. Analog voltages and currents can be measured with<br />
very high precision. Its Ohm meters automatically switch ranges from μOhm<br />
to kOhm to allow for a wide variety of applications. Testing of unconventional<br />
equipment, such as Rogowski Coils or current sensors completes the<br />
spectrum. Safety features: emergency shut off button, safety key lock (block<br />
unauthorised use).<br />
<br />
OMI,CPSB1 (4605) AU<br />
Switch Box to allow fully automated 3 phase transformer<br />
testing, accessory for the CPC100.<br />
Omicron CP TD1 Tangent Delta & <strong>Power</strong><br />
Factor Measuring Test Set<br />
OMI,CP-TD1 (4619) AU<br />
Provides automatic testing of transformer parameters<br />
within one portable system. Comprises of CPC 100<br />
Multifunction Primary Test System and the CP TD1<br />
Tangent Delta unit. CPC 100 is the main control unit for<br />
the test system and the CP TD1 unit is used for testing<br />
of insulation condition. All test results stored in one<br />
device and in the same format. Excellent line-frequency suppression in the<br />
presence of electrical and magnetic interference. High precision components<br />
for measuring voltages and currents and a gas-insulated reference capacitor<br />
for capacitance and Tan delta measurement. Portable, heaviest component<br />
29kg. Automated Testing and Reporting; Test plans and parameters can be<br />
prepared off-line on the computer. Reports are generated automatically.<br />
Omicron FRA Frequency Response<br />
Analyser<br />
OMI,FRA (4621) AU<br />
For power transformer diagnosis. Applies a<br />
voltage across a range of frequencies (10Hz to<br />
20MHz) to the device under test. The measurements<br />
can subsequently be used to evaluate the<br />
mechanical integrity of cores, windings and clamping structures within power<br />
transformers by measuring their electrical transfer functions over a wide frequency<br />
range. Each electrical network has got its unique frequency response,<br />
the so-called fingerprint. Faults, mechanical shocks (i.e. earthquakes) or<br />
transportation cause deviations of this frequency response. Comparing measurements<br />
of different phases, sister units or the actual fingerprint with earlier<br />
measurements done on the same transformers allows to indicate positional or<br />
electrical variations of the internal components.
SMRT36<br />
The SMRT solution<br />
for your testing<br />
needs.<br />
The SMRT36 is the<br />
smallest, lightest,<br />
highest output powered,<br />
complete 3-phase<br />
protective relay test<br />
system in the world<br />
today. This rugged<br />
test system may be<br />
customized by adding<br />
the voltage current<br />
generator modules<br />
needed for specific test<br />
applications. Manual<br />
operation is simple<br />
through the use of<br />
the Smart Touch View<br />
Interface (STVI), with<br />
a large color high<br />
resolution TFT LCD<br />
touch-screen.<br />
Rugged, small and lightweight<br />
Up to 60 Amps per phase<br />
Up to 6 currents with convertible channels<br />
Thermally controlled fans for quiet operation<br />
New Smart Touch View Interface (STVI) provides manual control<br />
New STVI Overcurrent Test includes over 100 relay specific<br />
time-curves built-in<br />
With these comprehensive capabilities and extensive testing options the SMRT36 is<br />
conceivably the easiest to use 3-phase protective relay test system available today.<br />
For more information on the SMRT36 Relay Test Set contact us today to<br />
receive a SMRT36 brochure and Megger <strong>Power</strong> Catalogue.<br />
Megger Pty Limited<br />
Unit 1, 11-21 Underwood Road<br />
Homebush Australia NSW 2140<br />
T +61 (0)2 9397 5900<br />
F +61 (0)2 9397 5911<br />
E ausales@megger.com<br />
The word “Megger” is a registered trademark<br />
41<br />
WWW.MEGGER.COM
ELECTRICAL POWER<br />
Current Injectors<br />
Multi-Amp MS-2 High Current Test Set<br />
MUL,MS-2 (8415) AU<br />
Designed to test overload relays, circuit<br />
breakers and earth fault trip devices.<br />
Input 240V 50/60Hz. Output continuously<br />
adjustable in 4 ranges 120V/5A, 24V/25A,<br />
6V/120A & 3V/240A. Short term over<br />
current of several times the rated current ranges is possible. Digital current<br />
meter has read and hold facilities for short duration currents. Digital timer<br />
measures elapsed time between energisation and the test device operating.<br />
Programma Magnus 2.2kV Step Up<br />
Transformer for Testing CT’s<br />
PRO,MAGNUS-2.2kV (8464) AU<br />
Use in high-voltage substations and industrial<br />
environments. Protected with thermal<br />
cut-outs, mains voltage 230Vac ±10%, 50 to<br />
60Hz, power consumption is 2.3kVA. Used<br />
for preparing excitation curves for instrument<br />
transformers and for demagnetizing current transformer cones. Safety key<br />
lock (block unauthorised use).<br />
SMC PTE-100-C<br />
Secondary Current Test Set<br />
SMC,PTE-100-C (8414) AU<br />
AC current and voltage outputs in 4 ranges<br />
200V/5A, 40V/25A, 20V/50A & 10V/100A.<br />
Additional outputs AC voltage 0 to 220V at 1A<br />
(4A 1min), DC voltage 0 to 350V at 0.7A (2.8A<br />
1min), DC voltage 0 to 250V at 0.25A, fixed 110V AC at 0.3A. Timer 1ms<br />
to 99,999s. Additional functions include measurement of the phase angle<br />
between the voltage and the current output tap selected, and the measurement<br />
of the impedance of the load connected in the current output taps.<br />
T&R 200A-3PH/ED Current injection tester<br />
T&R,200A3PHEDIT (8464) AU<br />
0 to 200A/phase output capacity. <strong>Power</strong> supply 4 wire<br />
5A/phase 3ph 240/415V. Typically 10A 5 pin 3 phase<br />
socket outlet HPM.<br />
T&R CIT/LU2000 Primary Current Injection<br />
Test Set<br />
T&R,CIT (8481) AU<br />
Comprises control unit and 2kA loading unit<br />
(LU). Control unit includes timer, current and<br />
voltage meters, and variable output transformer.<br />
External loading unit output 0 to 2kA, duty 5min<br />
on 15min off at 6VAC, continuous 0 to 1kA at<br />
3VAC. Two units weight 35 & 45kg plus 2 quad<br />
70mm2 cable sets each 3m long. Control unit<br />
connects to LU with supplied interface cable.<br />
T&R PCU1-SP with CT Ratio/<br />
Polarity and NLU5000A Loading Unit<br />
T&R,PCU1-SP NLU5000A (8482) AU<br />
Medium powered primary current injection system.<br />
Features 5kA maximum output current (higher overload<br />
current for 2s). Multi-function digital timing system.<br />
Digital true RMS memory ammeter. Solid state switching.<br />
2,000A and 5,000A load units. Three range outputs on<br />
loading units. Rugged, compact design. Secondary injection up to 100A.<br />
Direct reading CT ratio and polarity. May be configured to either give a<br />
maximum current of 5,000A on the 2.3V range, 2,500A on the 4.6V range or<br />
1,250A on the 9.2V range.<br />
42<br />
www.techrentals.com.au<br />
Protection Relay Testing Systems<br />
Megger Protective Relay Test System<br />
IEC 61850<br />
MEG,MPRT8430-BAS-3CH (4607) AU<br />
Performs routine testing of protective relays.<br />
The standard configuration delivers three<br />
voltages and three currents, or six currents.<br />
Specifications: AC current output: 0 to 90A, AC voltage output: 0 to 600V,<br />
DC voltage output: 0 to 600V, frequency range: 0.001 to 9999.999Hz. The<br />
TouchView Interface Controller features a full color, touch screen interface.<br />
Includes AVTS software.<br />
<br />
OMI,CMA156-6PCA (4604) AU<br />
Six-phase current amplifier for tests requiring higher currents and/or higher<br />
power in the current path than is delivered by the CMC 156/256 or more than<br />
3/6 current channels (e.g., for testing three-winding transformer differential<br />
protection). Contains six independent current channels. Arranged in two<br />
isolated groups (A, B) and can be used independently of those of the CMC<br />
156/256. Connected to the CMC by means of a control cable. With a CMLIB<br />
F the available output power can be increased by a factor of 3 (210 VA at 7,5 A<br />
instead of 70 VA) for all single-phase fault loops.<br />
Omicron CMC256-6 Advanced Protection Relay Test Set<br />
OMI,CMC256-6 (4612) AU<br />
Advanced 3ph dynamic automatic protection relay test system.<br />
Current, integral 3ph current source max 140VA, 6 output sources,<br />
resolution 500μA, suitable for most relay types, including some high<br />
burden units. Voltage, 3ph 0 to 300RMS. Auxiliary DC supply, 0 to 264V, 0.2A.<br />
Relay monitoring trip, monitoring 6 isolated inputs, can be configured to be voltage<br />
free or 0 to 250V. Contact outputs 6 isolated change-over relay contacts<br />
(software controlled). Max 250VAC, 10A or 125VDC 1A. Interface connector,<br />
16 TTL digital inputs and outputs. Scope analogue inputs, 2 isolated analogue<br />
inputs ±500V peak max 12 bit resolution. Input supply 90 to 260VDC, 400Hz.<br />
Intuitive on-line help. Laptop and Test-Universe software up to TU V 2.01 supplied<br />
with test set, interface parallel port.<br />
Omicron CMGPS Syncronisation Control Unit<br />
OMI,CMGPS (4616) AU<br />
Accessory for the Omicron CMC etc. A single GPS unit, if used to sych relay<br />
tests when performing end-to-end tests of line protection systems two are<br />
required. The unit provides a start signal pulse based on the GPS clock time<br />
base. Software is both integrated in the testing modules (State Sequencer)<br />
and can also be used as a stand-alone application.<br />
Omicron C-Probe-1 Clamp-on CT AC/DC<br />
OMI,C-PROBE1 (4614) AU<br />
An active AC & DC current probe with voltage output. Recommended<br />
accessory for measuring currents with the CMC 256. Two measuring ranges:<br />
10A & 80A. Frequency range DC 10kHz. Accuracy error < 2% for currents up<br />
to 40A and frequencies up to 1kHz. Phase error < 0.5O @ 50/60Hz. Length<br />
230mm. Output: 0-10A range 100mV/A, 0-80A range 10mV/A.<br />
Programma EGIL Circuit Breaker Analyser<br />
<br />
One main contact per phase. Three time channels are<br />
connected together on one side. Events at parallel<br />
contacts equipped with pre-insertion resistors<br />
are recorded and displayed simultaneously.<br />
Two separate time channels for measurement of auxiliary contacts. On-site<br />
hookup comes with ready-made multi-cable sets for both main and auxiliary<br />
contacts. Coil currents are measured automatically, presented together with<br />
other readings immediately after testing on the display window or via the builtin<br />
printer. A built-in sequencer (program unit) sets the instrument automatically<br />
for the next sequential breaker operation. Intended primarily for measuring<br />
travel (motion). Can be equipped with an optional serial interface (RS232C) for<br />
communication with a PC and the CABA Win Breaker Analysis Software.
www.techrentals.com.au<br />
Protection Relay Testing Systems<br />
cont’d.<br />
Programma Sverker 760 Relay Test Set<br />
PRO,SVERKER760 (4602) AU<br />
Relay test set for 1ph protective relay equipment. Three phase relays<br />
can be tested 1 phase at a time or by synchronising more than one unit.<br />
Current ranges to 100A with full load current to 250A. AC outputs to 250V &<br />
DC outputs to 300V. In-built capacitor and resistors for current output phase<br />
shifting (3,600). In-built timer, ammeter, and voltmeter. Measures phase angle,<br />
PF, and impedance.RS232 communications and control interface.<br />
T&R DVS3-HP Static Relay<br />
Test System<br />
T&R,DVS3-HP (4608) AU<br />
Test system for testing voltage and frequency<br />
protection relays and transducers. Tests<br />
Automatic Voltage Regulating (AVR) relays with line drop compensation,<br />
under and over voltage relays, directional over-current relays, df/dt (ROCOF)<br />
relays, vector surge (step change of phase) relays and check synchronising<br />
relay. Generates a 3ph voltage output from a 1ph supply, and may be used in<br />
conjunction with a current source to test directional protection. Requires 1ph<br />
50/60Hz supply of 115V or 230V (±15%)..<br />
AC Sources/Inverters/Generators<br />
Behlman BL1350C-2 1350 VA <strong>Power</strong> Amp<br />
BEH,BL1350C-2 (8211) AU<br />
AC power amplifier with oscillator. Maximum power output 1350VA. Maximum<br />
current 10A on 0 to 135V range, 5A on 0 to 270V range. Output frequency<br />
45 to 500Hz. External frequency synchronising input. Remote 0 to 10VDC<br />
programming of output frequency and voltage. Digital true rms readout of<br />
voltage and current.<br />
Chroma 61501 Programmable AC <strong>Power</strong> Source<br />
CHR,61501 PAC-PS (8214) AU<br />
<strong>Power</strong>: 500VA. Voltage: 0-150V/0 to 300V/AUTO. Compact size<br />
<br />
mode. Programmable output impedance for IEC 61000-3-3. IEC 61000-4-11<br />
voltage dips and variation simulation. Harmonics, inter-harmonics waveform<br />
synthesizer for IEC 61000-4-13 testing. <strong>Power</strong> line disturbance simulation<br />
capability. Programmable voltage, current limit. Comprehensive measurement<br />
capability, including current harmonics. High output current crest factor, ideal<br />
for inrush current testing. Turn on, turn off phase angle control. TTL signal<br />
which indicates output transient. Software for IEC regulation test. Analog<br />
programmable interface. Optional GPIB and RS232 interface.<br />
Elgar 501 AC <strong>Power</strong> Source<br />
ELG,501 (8209) AU<br />
AC power amplifier. Operates from 240V 1ph AC. Output ranges on tapped<br />
transformer 0 to 65, 0 to 130, 0 to 260VAC. Output power 500VA. Amplifier<br />
output rated over 45Hz to 5kHz. Two units may be connected for 1kVA output. .<br />
<strong>Power</strong> Transformers<br />
Ferguson 115-2000 2kVA 240/115V Transformer<br />
FER,115-2000 (8203) AU<br />
240 to 115VAC, 1kVA stepdown transformer.<br />
Tortech 240-110 2000 VA Transformer<br />
TOR,110-2000 AU<br />
Step-down transformer. 240 to 110 VAC. 2,000 VA.<br />
Variac 3kVA 0 to 260VAC Output Variable Transformer<br />
VAR,3000 MY<br />
3kVA 0 to 260VAC output.<br />
43<br />
ELECTRICAL POWER<br />
<strong>Power</strong> Transformers cont’d.<br />
Variac 6500-3 3ph 6.5kVA Transformer<br />
VAR,6500-3 (8208) AU<br />
Variac 3ph 6.5kVA. 0 to 470VAC output for 415VAC input, max current 8A/ph.<br />
Dimmer Dot Variable AC Voltage Auto Transformer 3 Phase 23-28A<br />
VAR,D-283-OB (8210) AU<br />
Manual operated air cooled; Input 400/415V, 50Hz. Output 0 to 415/470V. 23<br />
to 28A. Total Weight 95kgs..<br />
<strong>Power</strong> Line Conditioners/UPS<br />
Chloride Active 3kVA UPS<br />
CHL,ACTIVE3000 (8559) AU<br />
Double conversion sinewave output. Dual PC interfaces. Typical run time<br />
<br />
<br />
H. Weight 81kg. MopUPS Professional software for system monitoring<br />
and shutdown included. USB port & RS232 communication port for UPS<br />
monitoring and management.<br />
Socomec Sicon ENT-TW10 1kVA UPS On-Line Double Conversion<br />
SOC,ENT-TW10 (8515) AU<br />
Suitable for mainly Business Server, Internet/Intranet Server, Critical<br />
Applications, Domestic and Industrial Automation, Networking and ISP/ASP<br />
Application etc. On-line double conversion technology, high stability of output<br />
voltage and frequency, high input power factor, automatic battery test, optional<br />
battery pack expansion, minimal desktop space and easy to install, RS232<br />
and USB communication interface, high efficiency, automatic by-pass, 4<br />
output sockets and slot for insertion of SNMP/WEB Manager or relay card.<br />
Upsonic <strong>Power</strong> Conditioner 3000VA<br />
UPC,3000 (8500) AU<br />
3kVA <strong>Power</strong> Conditioner single phase with 230V/15A power cord and output<br />
leads with 230V/15A socket. High energy surge absorbers, LC filter, EMI filter.<br />
Fast response time 4ms per step, precise voltage regulation. Flexibility for<br />
any loads, like pure resistive load/capacitive load/inductive load. Automatic<br />
electronic bypass protection, overload protection, over range protection. Wide<br />
input voltage range.<br />
Upsonic Battery Bank - 7AH Suitable for UPS, IH3000 3kVA UPS<br />
UPS,BATTERY BANK-7AH (8544) AU<br />
Battery Pack 32 x 12V 7Ah suitable for UPS,IH3000 3kVA UPS unit. Fitted with<br />
in-built charger card IH 3kVA 500W 120VDC. Back-up run time 2 to 3h at<br />
1,000W load..<br />
Battery Management Systems<br />
Hioki Battery HiTester<br />
HIO,3551BATTERYTEST (8655) AU<br />
Takes on-the-spot measurements of the<br />
internal resistance, voltage and temperature of<br />
lead-acid batteries, principally for UPS and similar<br />
applications, without needing to shut off the battery. Instantaneous results, on<br />
a three-rank scale of Pass, Warning, or Fail, using a composite decision based<br />
<br />
for high capacity batteries (of at least 500Ah). Includes Hioki 9460 clip type<br />
temperature leads.<br />
Programma Torkel 840 Battery Load Units<br />
<br />
PRO,TORKEL-840 (8654) AU<br />
For battery systems ranging from 12 to 250V. Discharging<br />
can take place at up to 110A. Tests can be conducted at<br />
constant current, constant power, constant resistance or<br />
in accordance with a pre-selected load profile.
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Temperature Meters/IR Thermometers<br />
Infrared Thermal Imaging Cameras<br />
Endoscopes Borescopes Visual Inspection<br />
High Speed Video Inspection Cameras<br />
Tachometers/Stroboscopes<br />
Laser Rotational Shaft Alignment<br />
Industrial Process Calibrators<br />
Dry Block & Temperature Calibrators<br />
Strip Chart <strong>Recorders</strong><br />
High Speed Waveform <strong>Recorders</strong><br />
Data Loggers<br />
Pressure & Humidity Transducers<br />
Pressure Vacuum Gauges/<strong>Recorders</strong><br />
Flow Meters for Liquids & Gases<br />
Combustion, Flue & Industrial Gas <strong>Analysers</strong><br />
Environmental Test Chambers/Ovens<br />
Ultrasonic Baths<br />
Temperature Meters/<br />
IR Thermometers<br />
Fluke 52-2 Digital Thermometer<br />
FLU,52-2 MY<br />
Dual input thermocouple thermometer supplied with two K<br />
type thermocouples for differential measurements. Sampling<br />
rate of 1Hz (1 probe) or 1.7Hz (2 probes). Will continuously<br />
record max and min measurements. It also can take K,J,T<br />
and E type Thermocouple inputs. Temperature range: K type:<br />
-200°C to 1,372°C<br />
Fluke 54-2 Dual Input TC<br />
FLU,54-2 (4507) AU<br />
D series 2, dual input digital thermometer with data logging.<br />
Takes J, K, T, E, R, S, N T C inputs. Accuracy ±0.05% +0.3ºC.<br />
500 point logging with date and time stamp. Records min,<br />
max or avg. Logged data can be reviewed on meter or downloaded<br />
via IR port.<br />
Fluke 54-2 Dual Input TC with Flukeview<br />
Logging Software<br />
FLU,54-2FLUKEVIEW (4511) AU<br />
Series 2, dual input digital thermometer with data logging.<br />
Will take most TC inputs. Accuracy ±0.05% +0.3ºC. 500 point<br />
logging with date & time stamp. Also records min, max or avg.<br />
Logged data can be reviewed on meter or downloaded via IR<br />
port RS232 interface, (using cable and Flukeview software<br />
included).<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
44<br />
Temperature Meters/<br />
IR Thermometers cont’d.<br />
www.techrentals.com.au<br />
Fluke 576 Photographic Temperature Infrared<br />
Thermometer Built in Camera<br />
FLU,576 (4519) AU/MY<br />
Range -30 to 900ºC. Minimum measurement 19mmØ,<br />
laser class II, 3 point spot. Includes adjustable emissivity<br />
from 0.1 to 1 by 0.01. Target size 1/60 of distance. Max,<br />
min, dif and av displayed on backlit lcd with bar graph.<br />
Data output USB or 1mV/ºC, windows software and<br />
cable included. Accuracy ±0.75% of reading or ±1ºC<br />
whichever is greater. Response time 250ms. Display<br />
resolution 0.1ºC. Continuous measure mode. Digital<br />
camera and flash built in.<br />
Fluke 80TK Thermocouple Module<br />
FLU,80TK (4531) AU<br />
Use with DVM’s and recorders. Accepts K thermocouples. Temperature range<br />
-50 to 1,000ºC. Output 1mV/ºC. Type 80KP-1 probe included.<br />
Fluke 80PK-26 Type-K Thermocouple Probe<br />
FLU,PROBE-TEMP-26 (4535) AU<br />
Type-K thermocouple with tapered tip for use in air, non-caustic gas and<br />
surface applications. Measurement range -40 to 816ºC.<br />
Hart 1521 NATA Precision Handheld<br />
Thermometer<br />
HAR,1521-NATA (4515) AU<br />
Accuracy 0.025ºC. Includes 5615 probe ¼”Ø x 12” long.<br />
Calibrated in the -183 to 500ºC range. Probe operating range<br />
-200 to 420ºC (cable and transition to 150ºC max).<br />
Hart 1523 NATA Precision Handheld<br />
Thermometer<br />
HAR,1523-NATA (4514) AU<br />
Precision, portable, electronic thermometer with trending<br />
and 25 memory positions for NATA-traceable calibration<br />
and high accuracy. Includes 5616 probe 298mm x 6.35mm<br />
100ohm platinum resistance thermometer probe (PRT) -200<br />
to 420°C, stability +/-10mK, accuracy +/-0.012°C at -200°C,<br />
+/-0.011°C at 0°C, +/-0.028°C at 420°C.<br />
Raytek MX6 Photographic Temperature Infrared<br />
Thermometer with built in Camera<br />
RAY,MX6 (4523) AU<br />
Range -30 to 900ºC with built in digital camera. Min<br />
measurement 19mmØ, laser class II, 16 point circle spot.<br />
Includes adjustable emissivity from 0.1 to 1 x 0.01. Target<br />
size 1/60 of distance. Max, min, dif and av display with<br />
backlit lcd with bar graphData output USB or 1mV/ºC,<br />
windows software and cable included. Accuracy ±0.75%<br />
of reading or ±1ºC whichever is greater. Response time<br />
250m/s. Display resolution 0.1ºC. Continuous measure<br />
mode. Digital camera and flash built in.<br />
Testo 845 IR Thermometer with<br />
Humidity Probe and T/C Probe<br />
TES,845 (4527) AU<br />
Temperature measurement -35 to 950°C. Relative humidity<br />
probe 0 to 100%RH. Fast-action surface probe with sprung<br />
thermocouple strip, also for uneven surfaces. Switchable<br />
optical resolution: far field: 75:1 (16mm at a distance<br />
of 1200mm). Close focus: 1mm at a distance of 70mm.<br />
Adjustable emissivity from 0.1 to 1, max, min, displayed<br />
on backlit LCD. Continuous measure mode. Data output<br />
software and cable included. Accuracy ±0.75% of reading<br />
100 to 950°C. Display resolution 0.1°C.
www.techrentals.com.au<br />
Infrared Thermal Imaging Cameras<br />
Flir E60 Infrared Thermal<br />
Imaging Camera<br />
FLI,E60 (4550) AU<br />
-20°C to 650°C, IR resolution 320x240, 60Hz, visual image<br />
3mpix, built in LED lamps for poorly lit environments, laser<br />
locator, scalable picture in picture. MPEG4 recording, touch<br />
screen, composite video out, Wi-Fi, and USB. Applications<br />
include electrical distribution, mechanical (belts, rollers,<br />
couplings, gaskets/seals, compressors etc), product development, HVAC/R,<br />
automotive. Bluetooth support for voice annotations and selected Extech<br />
equipment. PC software provided. iPhone/iPad app available.<br />
Flir I60 Infrared Thermal Imaging Camera<br />
FLI,I60 (4552) AU<br />
-20°C to 350°C, visual image 2.3Mpix, built<br />
in LED lamps, laser locator, scalable picture in picture.<br />
Applications include electrical distribution, mechanical<br />
(belts, rollers, couplings, gaskets/seals, compressors etc),<br />
product development, HVAC/R, automotive. Bluetooth<br />
support for voice annotations and selected Extech<br />
equipment. PC software provided.<br />
Flir T400 Infrared Thermal Image Camera<br />
FLI,T400 (4557) AU<br />
-20°C to 1200°C with MPEG 4 video, is suitable for<br />
almost any application such as electrical surveys,<br />
building diagnostics and mechanical inspections. With<br />
a 3.5” touch screen, Fusion functionality (visible image<br />
with IR overlay), auto and manual focus, target illuminator, laser locator,<br />
emissivity list of predefined materials, voice text and sketch annotation.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Professional thermographer?<br />
Building inspector? Electrical inspector?<br />
FLIR Systems - the world leader in infrared<br />
cameras - has the camera that’s right for you.<br />
FLIR i-Series<br />
The revolutionary FLIR i3, produces<br />
powerful snapshots of temperature<br />
differences equal to 3,600 readouts from<br />
a single spotmeter – the i5 and i7 models<br />
even more!<br />
FLIR E-Series<br />
The ground-breaking FLIR E-Series<br />
is even more affordable packed with<br />
features like Bluetooth and industryfirst<br />
Wi-Fi connectivity, 3.5” touchscreen<br />
and iPhone/iPad App. Add to this<br />
MeterLink, the pioneering wireless<br />
connection that connects your IR camera<br />
with your ClampMeter.<br />
Infrared Thermal Imaging Cameras<br />
cont’d.<br />
Fluke Ti25 Infrared Thermal<br />
Image Camera<br />
FLU,TI25 (4567) AU/MY<br />
Temperature range -20°C to 350°C, accuracy<br />
±2°C or 2% (whichever is greater). Manual<br />
focus. SD memory card (2GB memory card will<br />
store at least 1200 fully radiometric (.is2) IR and<br />
linked visual images each with 60s voice annotations or 3,000 basic (.bmp)<br />
IR images). Export file formats JPEG, BMP, GIF, P, TIFF, WMF, EXIF, and<br />
EMF. IP54 rating.<br />
Fluke Ti32 Infrared Thermal Image Camera<br />
FLU,TI32 (4559) AU<br />
-20°C to 600°C, resolution 320x240. Applications<br />
include inside and outside electrical distribution, motors,<br />
pumps, generators, mechanical (belts, rollers, couplings,<br />
gaskets/seals, compressors etc). Process industry tanks/<br />
vessels, pipes, valves, traps, reactors, and process insulation,<br />
HVAC/R.<br />
Fluke Telephoto Infrared Lens<br />
FLU,TI32_TELEPHOTO (4564) AU<br />
Field swappable, telephoto thermal lens allows the<br />
user to see and measure the temperature of objects at<br />
greater distances, such as power transmission lines,<br />
or smaller objects at normal distances. Field-of-View<br />
(FOV) is 11.5° x 8.7°. For use with the Ti32 and TiR32<br />
FLIR T-Series<br />
The new T600-Series takes quality<br />
of image and ergonomics to a whole<br />
new level with a long list of impressive<br />
features including Wi-Fi connectivity,<br />
4.3” touchscreen, MeterLink and iPhone/<br />
iPad App.<br />
Local Service Network<br />
Who else would you trust to calibrate<br />
and service your FLIR camera but FLIR<br />
Australia? It makes perfect sense. We are<br />
a factory certified service centre for all<br />
FLIR IR cameras. Many FLIR cameras are<br />
eligible for FLIR’s industry leading 2-10<br />
year product and detector warranties.*<br />
*Terms and conditions apply<br />
FLIR Systems Pty Ltd. 10 Business Park Drive, Notting Hill, Victoria 3168, Australia<br />
VIC: 03 9550 2800 NSW: 02 8853 7870 WA: 08 6263 4438 QLD: 07 3861 4862 SA: 08 8274 3747<br />
Tel AU: 1300 729 987 NZ: 0800 785 492 Email: info@flir.com.au www.flir.com<br />
ISO No. FLIR20850
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Infrared Thermal Imaging Cameras<br />
cont’d.<br />
Fluke Telephoto Wide-Angle Lens<br />
FLU,TI32_WIDE-ANGLE (4559) AU<br />
Field swappable, wide angle thermal lens allows the user<br />
to have a wider field of view for working in tight spaces,<br />
small rooms, etc. Field-of-View (FOV) is 46° x 34°. For<br />
use with the Ti32 and TiR32.<br />
Fluke TiR32 Infrared Thermal<br />
Image Camera<br />
FLU,TIR32 (4563) AU<br />
Infrared thermal image camera. -20°C to 150°C,<br />
resolution 320x240. Applications include energy audits,<br />
building maintenance, restoration and remediation.<br />
Locate damaged or unsealed components of HVAC/R, air<br />
leakage from worn seals on windows and doors. Also<br />
features a Dew point alarm.<br />
Marconi Argus2 Black & White Thermal Camera<br />
MAR,ARGUS2 (4575) AU<br />
Live thermal image, quick and clear image. Good for fast assessment.<br />
Applications include general industrial work, electrical work, surveillance<br />
work. Video out is an NTSC grey scale. Range is 0 to 500ºC. Dust and water<br />
proof to IP67.<br />
46<br />
Infrared Thermal Imaging Cameras<br />
cont’d.<br />
Testo 880-3 V4 Professional Set Thermal<br />
Imaging System<br />
TES,880-3 V4 (4571) AU<br />
-20 to 350 ºC switchable. Display resolution 0.1ºC. Continuous<br />
measure mode. Plug in T/C 350 ºC (Switchable). Infrared<br />
camera with integrated digital camera equipped with power<br />
LEDs for dark area illumination. Applications include (but not limited to) In<br />
building thermography, electrical, mechanical and preventative maintenance,<br />
production and R&D monitoring, technical diagnostics, underfloor heating and<br />
mould growth detection. Includes software for report creation.<br />
Endoscopes Borescopes<br />
Visual Inspection<br />
See also Pipeline & Cavity Inspection on page 67 & 68<br />
www.techrentals.com.au<br />
Fibrescope MTFS15-1000 1.5mm x 1m Endoscope<br />
FIB,MTFS15-1000 (5127) AU<br />
Working length 1.5mmØ x 1,000mm. Includes light source. Operating<br />
temperature -20 to 60ºC at atmospheric pressure.
www.techrentals.com.au<br />
Endoscopes Borescopes<br />
Visual Inspection cont’d.<br />
Heine Techno 6mm x 320mm T.05.26.302 Borescope<br />
HEI,TECHNO-6X320 (5175) AU<br />
Direction of view 70º, with angled extension tube 120º x 120º.<br />
Battery pack included, dc supply cord, battery charger and<br />
mains power pack.<br />
Moritex PalmScope Video Capture Device for<br />
JPEG & Movie Clip Recorder Inspection<br />
MOR,PALMSCOPE (5149) AU<br />
Digital Video Recorder, image capture and storage.<br />
Used in conjunction with an endoscope, borescope<br />
or videoscope the PalmScope is an alternative to a VCR for onsite inspection<br />
applications. Unit records, store video sequences and full frame resolution<br />
jpeg images on supplied 512Mb Compact Flash Card. View images on built<br />
in 6.4” TFT LCD screen. Stores jpeg still images and or mjpeg movie clips.<br />
Signal input video NTSC or PAL, auto-selecting.<br />
Olympus IF8C5-30 8mm Diameter, 3m Length Optical Fibre<br />
Endoscope<br />
OLY,IF8C5-30 (5160) AU<br />
3.25m long (effective 3m), 8mm diameter, angulation range, 4 direction,<br />
Up, Down 120º, Right, Left 100º, light guide cable length 2m. Optical<br />
adaptor fitted AT60DFF, field of view 60º, forward viewing, depth of field<br />
20mm to infinity. Outer diameter 8.4mm. Operating temperature in air<br />
-10 to 80ºC, in water 10 to 30ºC. Operating pressure in air/water 1013 to<br />
1317hPa (1-1.3 atm) In air 1013hPa (1-1.3atm). Fluid resistance insertion tube<br />
withstands machine oil, light oil. Can insert insertion tube only in water.<br />
Supplied with eye piece and light source.<br />
Olympus IPLEX- MX Portable Industrial<br />
Videoscope<br />
OLY,IPLEX-MX (5170) AU<br />
Battery powered industrial videoscope,<br />
lightweight just 4.5kg out of transit case.<br />
6mmØ, 3m length tungsten insertion tube, articulation 4 way up/down/left/<br />
right 120º. Field of view 120º, depth of field 18mm to infinity, illumination<br />
method LED. Brightness adjustment 11 step, long exposure up to 1sec,<br />
zoom electronic linear up to 3x, built in 5.6inch TFT full colour display, image<br />
recording built in, image format JPEG, over 230 images with supplied CF card.<br />
<strong>Power</strong>ed from either rechargable Li-ion 2 x battery packs (4h) or AC adaptor.<br />
Olympus IPLEX- MX II Portable<br />
Industrial Videoscope<br />
OLY,IPLEX-MXII (5169) AU<br />
Battery powered industrial videoscope,<br />
lightweight just 2.5kg out of transit case.<br />
6mmØ, 3m length tungsten insertion tube,<br />
articulation 4 way UP/DOWN/LEFT/RIGHT 120º. Field of view 120º, depth<br />
of field 18 to 1,000mm, illumination method LED. Brightness adjustment<br />
and digital zoom, built in 6.5inch TFT colour display, record JPEG images<br />
to USB flash device. RCA composite video output. Battery or AC powered.<br />
Olympus IV6C6-20-ZOOM<br />
Videoscope 6mm x 2m Long<br />
OLY,IV6C6-20-ZOOM (5167) AU<br />
Fitted with AT120D/NF optical adaptor, field of view<br />
120º, direction of view forward, depth of field 5mm to<br />
infinity. Angulation 4 way, 150º up/down & left/right,<br />
heavy duty tungsten insertion braid tube. Operating<br />
temperature for insertion tube in air -10 to 80ºC, in water 10 to 30ºC. Liquid<br />
resistance for insertion tube - withstands machine oil, light oil and 5% salt<br />
water. Supplied with IV-6A video control unit, which has zooming and virtual<br />
scrolling (panning) with moving images function, extended exposure time<br />
for darker areas, built in image enhancement and freeze frame. ILH-2B light<br />
source, Panasonic 7” LCD colour monitor mounted on extension arm all fitted<br />
to transit case for ease of use. Video VHS recorder also included in package.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
47<br />
High Speed Video Inspection<br />
Cameras<br />
Casio Exilim Ex-F1 High Speed Camera<br />
& Lighting Kit<br />
CAS,EX-F1 (5133) AU<br />
Has two operating modes one as a high speed video<br />
camera it will record 1200 frames per sec @ 336x96<br />
pixels resolution. Secondly as a high speed still<br />
camera it will record 60 frames per second @ 2816 x<br />
2112 pixels resolution. This gives considerable detail<br />
at a high frame rate. The fastest shutter speed is 1/40,000 sec. It includes a<br />
x12 zoom and complete lighting setup and stands.<br />
Redlake 1000 Frames/Sec Motion Scope<br />
RED,S1000 (5135) AU<br />
Triggering facilities similar to a digital oscilloscope. 4,096 frames can be<br />
captured at up to 1,000 frames/s. Images can be viewed from a frame by frame<br />
basis to real time. Shutter speeds 1/60 to 1/10,000s. Monochrome image 336<br />
x 243 x 8bit pixels. Weight 5.5kg. PAL video output. Trigger input TTL. Use any<br />
standard oscilloscope to supply the signal. Adaptor can be used with<br />
endoscope.<br />
Tachometers/Stroboscopes<br />
Hioki 3404 Optical/Contact Tachometer<br />
HIO,3404 (5105) AU/MY<br />
Autoranging 4 digit display. Ranges in RPM mode 30 to 99.9, 1,000 to 9,999 &<br />
1,000 to 9,999 x 10. Ranges in RPS mode 0.5 to 99.99, 100 to 999.9 & 1,000<br />
to 1,600. Analogue output 1mV/10RPM or 1mV/100RPM, accuracy 4%. Tripod<br />
mounting. Internal battery or external AC operation. Contact adaptor included<br />
with cone and peripheral ring.<br />
Monarch Palmstrobe Compact Size<br />
Portable Stroboscope<br />
MON,PALMSTROBE (5103) AU<br />
Compact size portable stroboscope, flash rate from<br />
100 to 12,500FPM, 6 digit alphanumeric backlit<br />
LCD. Tachometer range 5 to 250,000RPM (only with<br />
external sensor connected, not included). External<br />
sensor input TTL only. Supplied with 2 x removable<br />
rechargeable battery packs, charger and transit case.<br />
Monarch Phaser Strobe Battery Operated<br />
MON,PHASER (5101) AU<br />
Phaser-stroboscope includes optical and magnetic pickup. Operates from<br />
internal re-chargable batteries or mains. Auto step mode provides slow<br />
motion appearance for high speed repetitive events. Stores and recalls last<br />
3 full settings in memory. Specifications: 30 to 30,000 fpm or 0.5-533.33 fps.<br />
Accuracy ±0.01%. Flash rate external triggering: 30 to 9,999.9 fpm, 0.5 to<br />
533.33 fps, 10,000 to 32,500 fpm. Phase delay facility.<br />
Monarch PLT200-KIT Digital<br />
Contact/Non Contact Tacho<br />
MON,PLT200-KIT (5106) AU<br />
Hand held digital contact/non-contact tacho kit.<br />
Ranges optical/non-contact 5 to 200,000 RPM,<br />
contact 0.5 to 20,000 RPM. Display 5 digits, 5 alpha<br />
numeric LCD. Non contact operating range 90cm,<br />
tripod mounting. Direct contact tips and contact wheel<br />
supplied. Programmable for IPM, FT/M, YPM, cm/M,<br />
m/M, RPM, RPS, RPH and Totaliser up to 200,000.<br />
Output TTL pulse.
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Laser Rotational Shaft Alignment<br />
Fixturlaser Dirigo Laser Bases Shaft<br />
Alignment System<br />
FIX,DIRIGO (4940) AU<br />
Measurement resolution to .01mm Shaft diameter<br />
range 40 to 150mm using an extension chain 150 to<br />
500mm. Maximum distance between measurement<br />
units 0.85m. Very simple to use and operate as<br />
shims are applied the alignment can be monitored<br />
in real time. 20h of operation from alkaline<br />
batteries.<br />
Fixturlaser PAT Pulley Alignment System<br />
FIX,PAT (4941) AU<br />
Laser based alignment system for pulley systems. Measurement accuracy<br />
0.5mm (0.2º). 20hrs of operation on AAA batteries. Mechanically self centres<br />
on pulley, will operate successfully even on worn pulley systems.<br />
Pruftechnik 1500mm length Tension Chains<br />
PRU,AL12.116 (4946) AU<br />
1500mm length tension chains for PRU,ROT-ULTRA<br />
Pruftechnik Rotalign Pro Laser<br />
Shaft Alignment Ex<br />
PRU,ROT-PROEX (4943) AU<br />
Laser based rotating shaft alignment system. Maximum<br />
separation between emitter and receiver 10m. Aligns<br />
horizontal and vertical machines, aligns coupled<br />
and uncoupled shafts equally well. Intrinsically safe<br />
system.<br />
Pruftechnik Rotalign Ultra Laser<br />
Shaft Alignment<br />
PRU,ROT-ULTRA (4945) AU<br />
Laser based rotating shaft alignment<br />
system. Maximum separation between<br />
emitter and receiver 10m. Aligns<br />
horizontal and vertical machines, aligns<br />
coupled and uncoupled shafts equally<br />
well. Ultra modern computer design, backlit colour display, Intel XScale<br />
400MHz CPU, USB for peripheral devices, PC, printer, also Bluetooth<br />
communication. Backlit keyboard, rechargeable Li-Ion battery pack. Machine<br />
train alignment - 14 machines. Alignment results in 3 quick steps, thermal<br />
growth computation. Rotalign Ultra Reader software included.<br />
Industrial Process Calibrators<br />
See also Laboratory Calibrators on page 12<br />
Ametek PPCE 700Bar Pressure Calibrator with NATA Certification<br />
AME,PPCE-NATA (4780) MY<br />
High pressure calibrator with pump 700Bar (10,000psi). Digital display with<br />
5 digit resolution. Accuracy over 70Bar ±0.07. Accuracy below 70Bar ±0.35.<br />
Current and voltage measurement ranges 4 to 20mA, 0 to 50mA & 0 to 30V.<br />
Ametek Hydralyte HL2700N Dead Weight Tester<br />
AME,HL2700N MY<br />
Dual range interchangeable piston: 100 to 4,500kPa, 0.5kPa increments,<br />
500 to 22,500kPa, 1kPa increments. Accuracy 0.05% of reading.<br />
Includes special calculator for high accuracy pressure calculations and also<br />
conversion of units.<br />
48<br />
www.techrentals.com.au<br />
Industrial Process Calibrators cont’d.<br />
Barfield Airspeed and<br />
Altimeter Calibration Kit<br />
BAR,1811KIT (4788) AU<br />
Replacement gauges for the 1811<br />
pitot static tester. This kit will keep<br />
an 1811 calibration system operational during calibration downtime. The<br />
DAS650 is a 650 knot range. The DALT55 is for 55k feet.<br />
Beamex BIC200 Instrument Calibrator<br />
BEA,BIC200 (4752) AU<br />
For both electronic and pneumatic instruments. Output ranges settable<br />
to 119.9% of range 0 to 10V, 1 to 5V, 4 to 20mA, 0 to 20mA, 10 to 50mA<br />
& 0 to 50mA. Output source for current ranges 24 & 48V. Input ranges to<br />
<br />
measurement ranges 0 to 1Bar & 0.2 to 1Bar. Operates from internal NiCd<br />
batteries or external AC.<br />
Beamex MC5 Multifunction NATA Calibrator<br />
BEA,MC5 (4751) AU<br />
Provides calibration capability for pressure,<br />
temperature, electrical and frequency signals.<br />
HART communication and CMX software provided.<br />
Calibration results can be stored or printed.<br />
Performs as a field-entry device (FED) allowing for<br />
the recording of non-calibration related maintenance<br />
results. Pressure modules included, -1 to 20 bar<br />
and 600 bar (up to 1,000 bar with optional external<br />
transducers). DC voltage and current, frequency, and pulse measurement.<br />
RTD, thermocouple, and resistance simulation and measurement.<br />
Beamex MC5 Intrinsically Safe<br />
Multifunction NATA Calibrator<br />
BEA,MC5-IS (4750)<br />
Provides calibration capability for pressure,<br />
temperature, electrical and frequency signals.<br />
HART communication and CMX software provided.<br />
Calibration results can be stored or printed. Performs<br />
as a field-entry device (FED) allowing for the recording of non-calibration<br />
related maintenance results. Pressure measurement range, -1 to 20 bar<br />
and 600 bar (up to 1,000 bar with optional external transducers). DC voltage<br />
& current, frequency, and pulse measurement. RTD, thermocouple, and<br />
resistance simulation & measurement.<br />
Beamex PGXH, PGM and PGV<br />
BEA,PUMPS (4797) AU<br />
Hand pumps includes hand-held, lightweight pressure<br />
and vacuum sources for field use. The PG series of<br />
hand pumps are ideal pressure/vacuum generators<br />
to be used as accessories for pressure and vacuum<br />
calibration. Kit contains PGXH 0 to 700 bar, PGM 0 to<br />
20 bar, PGV 0 to -0.95 bar.<br />
Crystal nVision Pressure<br />
Calibrator 30b IS NATA<br />
CRY,NVISION-30-NATA (4716) AU<br />
Intrinsically safe pressure calibrator. Displays real-time<br />
recorded data graphically on a high res screen with<br />
ability to zoom into specific events. 500,000 data point<br />
memory records all data from all enabled screens from<br />
two modules simultaneously. Fastest logging interval<br />
10 readings/sec. Configured with MA20 current, voltage and switch test<br />
module and 30 bar pressure module, accuracy to 0.025% of reading. Includes<br />
hand pump and CPF (finger tight to 700 bar) fittings.
www.techrentals.com.au<br />
Industrial Process Calibrators cont’d.<br />
Druck DPI603 2Bar Pressure Calibrator<br />
DRU,DPI603-2 MY<br />
2Bar pressure calibrator. 0.075% FS Accuracy includes<br />
pump for vacuum and pressure. Unit will pump up to 2Bar<br />
pressure and -850mBar vacuum. Measurements can be<br />
made to 2Bar positive pressure and -1Bar vacuum.<br />
The unit has a 24V energising voltage. Monitors loop<br />
current to 55mA DC loop voltage to 50V. Sealed to IP65.<br />
Rechargeable battery operated. Unit can display in 24<br />
different units. BSP 1/8 interface.<br />
Druck DPI603 2-NATA 2Bar Pressure Calibrator<br />
DRU,DPI603-2-NATA (4766) AU<br />
0.075% FS Accuracy includes pump for vacuum and pressure. Unit will<br />
pump up to 2Bar pressure and -850mBar vacuum. Measurements can<br />
be made to 2Bar positive pressure and -1Bar vacuum. The unit has a 24V<br />
energising voltage. Monitors loop current to 55mA DC loop voltage to 50V.<br />
Sealed to IP65. Rechargeable battery operated. Unit can display in 24<br />
different units. BSP 1/8 interface.<br />
Druck DPI603 20Bar Pressure Calibrator<br />
DRU,DPI603-20 MY<br />
Accuracy 0.075%fs. Pumps up to 20Bar pressure & -850mBar vacuum.<br />
Measures up to 20Bar pressure & -1bar vacuum. In-built 24V energising<br />
voltage. Monitors loop current to 55mA. Loop voltage to 50V. Interface 1/8”<br />
bsp. Battery operated.<br />
Druck DPI610-2-NATA 2Bar Pressure Calibrator<br />
DRU,DPI610-2-NATA (4767) AU<br />
DRU,DPI610-2 MY<br />
Pneumatic pressure calibrator including pump and<br />
current voltage standard. Pressure range -1 to 2Bar,<br />
±0.025%fs. Voltage input ±50VDC, ±0.05%rdg,<br />
±0.004%fs. Current input ±55mA, ±0.05%rdg,<br />
±0.004%fs. Temperature -10 to 40°C, ±1 (ambient)<br />
switch open/closed. Voltage output 10VDC, ±0.1% or<br />
24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger stores<br />
up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />
flexible hose kit. Pump includes screw adjustment.<br />
Druck DPI610-20-NATA 20Bar Pressure Calibrator NATA Certification<br />
DRU,DPI610-20-NATA (4773) AU<br />
Pneumatic pressure calibrator including pump and current voltage standard.<br />
Pressure range -1 to 20Bar ±0.025%fs. Voltage input ±50VDC, ±0.05%rdg,<br />
±0.004%fs. Current input ±55mA, ±0.05%, rdg ±0.004%fs. Temperature -10<br />
to 40°C ±1°C (ambient) switch open/closed. Voltage output 10VDC ±0.1%<br />
or 24V ±5%. Current output 0 to 24mA ±0.05% rdg ±0.01%fs. Data logger<br />
stores up to 10,000 values. mA ramp configurable. Pressure port G 1/8f,<br />
includes flexible hose kit. Pump includes screw adjustment.<br />
Druck DPI610-20IS 20Bar Pressure Calibrator<br />
DRU,DPI610-20IS MY<br />
Ranges -1 to 20Bar. Accuracy 0.025% fs all ranges. Integral combined<br />
pressure/vacuum pump. Dual readout: input & output. 4 to 20mA loop test:<br />
auto step and ramp. RS232 interface and fully documenting version. Remote<br />
pressure sensors. Intrinsically safe version.<br />
Druck DPI610-400-NATA 400Bar Pressure Calibrator<br />
DRU,DPI610-400-NATA (4779) AU<br />
DRU,DPI610-400 MY<br />
Hydraulic pressure calibrator including pump and current voltage standard.<br />
Pressure range 0 to 400Bar ±0.025%fs. Voltage input 50VDC, ±0.05%rdg,<br />
±0.004%fs. Current input 55mA, ±0.05%rdg, ±0.004%fs. Temperature -10 to<br />
40ºC ±1ºC (ambient) switch open/closed. Voltage output 10VDC ±0.1% or 24V<br />
±5%. Current output 0 to 24mA, ±0.05% rdg, ±0.01%fs. Data logger stores<br />
up to 10,000 values. mA ramp configurable. Pressure port G 1/8” (f), includes<br />
flexible hose kit. Pump includes screw adjustment.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
49<br />
Industrial Process Calibrators cont’d.<br />
Druck DPI615-20-NATA 20Bar<br />
Pressure Calibrator<br />
DRU,DPI615-20-NATA (4773) AU<br />
Pneumatic pressure calibrator including pump and<br />
current voltage standard. Pressure range 0 to 20Bar<br />
±0.025% FS. Voltage input ±50VDC ±0.05% rdg<br />
± 0.004% FS. Current input ±55mA ±0.05%rdg<br />
±0.004%FS. Temperature -10 to 40ºC ±1ºC (ambient)<br />
switch open/closed. Voltage output 10VDC ±0.1% or<br />
24V ±-5%. Current output 0 to 24mA ±0.05%rdg<br />
±0.01%FS. Data logger stores upto 10,000 values. mA ramp configurable.<br />
Pressure port G 1/8 female, includes flexible hose. Pump includes screw<br />
adjustment.<br />
Druck DPI620 Advanced Modular<br />
Calibrator<br />
DRU,DPI620-AMC MY<br />
Can measure and source mA, mV, V, Ohms, frequency<br />
and a variety of RTDs and T/Cs. Accuracy from 0.0025%rdg + 0.002%FS. It<br />
provides an isolated 24V loop power supply to energize devices and control<br />
loops and a stabilized dc voltage supply for ratio metric transducers. A HART<br />
digital communicator is provided for set-up and calibration adjustment of<br />
HART devices.<br />
Druck PV411A Multifunction Hand Pump Kit<br />
DRU,PV411A (4717) AU/MY<br />
Provides up to 700Bar hydraulic, 40Bar pneumatic<br />
pressures and vacuum to -950 mBar. Built-in stroke<br />
adjuster, lower pressure fine control and tamper proof<br />
overpressure protection.<br />
Druck UPS III-IS Intrinsically Safe<br />
Loop Calibrator<br />
DRU,UPS III-IS (4748) AU<br />
Measure or source 0 to 24mA and provide 24V loop power.<br />
50 VDC measurement and continuity. Accuracy 0.015% of<br />
reading, Hart compatible. Dual mA and % readout, linear<br />
or flow. It is an essential tool for loop testing, instrument<br />
maintenance and valve set-up, with an easy-to-read<br />
display and simple-to-use time saving features.<br />
Emerson Process Management 375<br />
Field Communicator<br />
EME,375 (4798) AU/MY<br />
Will configure, test, and diagnose your<br />
HART® and Foundation FieldBus devices.<br />
Able to communicate with any device, by<br />
any manufacturer. Intrinsically safe. Easy<br />
upgrade over the Internet. Interfaces with<br />
AMS PC Suite Software.<br />
Emerson 475 Hart Communicator<br />
EME,475 (4799) AU/MY<br />
Will configure, test, and diagnose your HART® and<br />
Foundation FieldBus devices. Able to communicate with<br />
any device, by any manufacturer. Intrinsically safe. Easy<br />
upgrade over the Internet. Interfaces with AMS PC Suite<br />
Software.<br />
Fluke 70Bar Pressure Transducer to suit Fluke<br />
Calibrators 725 & 744<br />
FLU,700P08-70BAR (4723) AU<br />
For use with the Fluke 744 & 725 industrial calibrators.<br />
Pneumatic system range 0 to 70Bar, resolution 7mBar,<br />
reference uncertainty 0.025%. Connection 1/4NPT<br />
and 1/4 ISO Includes 700PTP-1 pressure pump (Note<br />
the pump will operate to 41Bar).
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Industrial Process Calibrators cont’d.<br />
Fluke 690Bar Pressure Transducer to suit<br />
Calibrators 744 & 725<br />
FLU,700P31-690BAR (4724) AU<br />
For use with the Fluke 744 & &25 industrial<br />
calibrators. Range 100 to 690kPa, reference<br />
uncertainty .025%. Connection 1/4NPT and 1/4 ISO<br />
Includes 700LTP-1 pressure pump.<br />
Fluke 7Bar Pressure Transducer & Pump to suit FLU,744 & FLU,725<br />
FLU,700PD6-7BAR (4722) AU<br />
For use with the Fluke 744 & &25 industrial calibrators. Range 100 to 690kPa,<br />
reference uncertainty .025%. Connection 1/4NPT and 1/4 ISO Includes<br />
700LTP-1 pressure pump.<br />
Fluke 700S/W-DPC-TRACK Software for 744 Process Calibrator<br />
FLU,700S/W-DPC-TRACK (4720) AU<br />
Provides means of building and maintaining an instrumentation maintenance<br />
database for Fluke 743B & 744 Documenting Process Calibrators.<br />
Fluke 718 300G Pressure Calibrator<br />
FLU,718-300G (4761) AU<br />
Pressure source and milliamp measurement. Pressure<br />
specs -83 to 2068kPa ±0.05% of range. Max pressure<br />
2.6MPa. Current specs: 0.0001mA resolution, accuracy<br />
0.015%. Calibrate P/I (pressure to current) transmitters,<br />
measures pressure via a 1/8 inch NPT pressure fitting<br />
and an internal pressure sensor, source pressure,<br />
measure current up to 24mA, simultaneously display<br />
pressure and current measurements, supplies loop<br />
voltage, calculates percentage in percent mode,<br />
calculates mA error in percent error mode.<br />
Fluke 719 2Bar-30G Pressure Calibrator including Electric Pump<br />
FLU,719-30G (4763) AU<br />
2Bar, includes pump and precision 4 to 20mA measurement and source<br />
capability. The pump in this instrument is electric. Uncertainty 0.025%.<br />
Precision pressure adjustment vernier. Range -850mBar to 2Bar. Resolution<br />
1mBar. 4 to 20mA resolution .001mA .015%rdg + 2 counts.<br />
Fluke Pressure Calibrator 8Bar Includes<br />
Electric Pump<br />
FLU,719-100G (4762) AU<br />
8Bar, includes pump and precision 4 to 20mA measurement<br />
and source capability. The pump in this instrument is<br />
electric. Uncertainty 0.025%. Precision pressure<br />
adjustment vernier. Range -850mBar to 8Bar. Resolution<br />
1mBar. 4 to 20mA resolution 0.001mA 0.015%rdg + 2<br />
counts.<br />
Fluke 725 Process Calibrator<br />
FLU,725-NATA (4719) AU<br />
FLU,725 MY<br />
DC voltage measurement 0.025%, 300V max, source<br />
0.02%, 11V max. DC current measurement 0.025%,<br />
110mA max, source 0.01%, 22mA max. Resistance<br />
<br />
<br />
50kHz, source 1 count 20Hz to 5kHz. ‘K’ thermocouple<br />
measurement 0.3ºC, source 0.3ºC. Pt100 RTD<br />
measurement 0.5ºC, source 0.2ºC. Measures and<br />
simulates 4 to 20mA, t/c E,N, J, K, T, B, R, S, & C, 2,<br />
3 & 4 wire RTDs and frequency. Operates from drycell<br />
batteries. (Includes NATA calibration - AU).<br />
50<br />
www.techrentals.com.au<br />
Industrial Process Calibrators cont’d.<br />
Fluke 743 Calibrator<br />
FLU,743B MY<br />
Includes RS232 interface. DC voltage measurement 0.025%, 300V max,<br />
source 0.01%, 15V max. DC current measurement 0.025%, 110mA max,<br />
<br />
<br />
1 count 20Hz to 5kHz. ‘K’ thermocouple measurement 0.3ºC, source 0.3ºC<br />
Pt100. RTDs measurement 0.3ºC, source 0.1ºC. Measures and simulates 4<br />
to 20mA, t/c E, N, J, K, T, B, R, S, & C, 2, 3 & 4 wire RTDs, frequency, test<br />
limit switches. Can use scaling factors for measurement & source. Built in<br />
calculator. Autostep function. Allows user entered values. Operates as an 8k<br />
point data logger. Note PC software only supports 15 tags.<br />
Fluke 744 DOC Calibrator with Hart<br />
FLU,744 (4725) AU/MY<br />
Documenting process calibrator which includes HART communication<br />
protocols for communicating with and setting up smart transmitters. RS232<br />
interface. DC voltage measurement 0.025%, 300V max, source 0.01%, 15V<br />
max. DC current measurement 0.025%, 110mA max, source 0.01% 22mA max.<br />
Resistance measurement 0.05%, 11kOhm max, source 0.01% 11kOhm max.<br />
Frequency measurement 0.5%, +5, 40~500Hz, source 1 count 20~5kHz. ‘K’<br />
thermocouple measurement 0.3ºC, source 0.3ºC Pt100. RTDs measurement<br />
0.3ºC, source 0.1ºC. Measures and simulates 4~20mA, t/c E, N, J, K, T, B, R,<br />
S & C, 2, 3 & 4 wire RTDs, frequency, test limit switches. Uses scaling factors<br />
for measurement & source. Built in calculator. Autostep function. Allows user<br />
entered values. Operates as an 8k point data logger. Note PC software only<br />
supports 15 tags.<br />
Fluke 773 Milliamp Process Clamp Meter<br />
FLU,773 (4751) AU<br />
Measure 4 to 20mA control lines, PLC loops, transmitters<br />
or any 4 to 20mA line without breaking the loop. Capable<br />
of 0 to 20.99mA and 24 to 100mA with clamp. Source<br />
and simulate mA and voltage signals in circuit. 4 to 20mA<br />
scaled o/p.<br />
Fluke 789 Process Meter<br />
FLU,789 PROCESSMETER (4718) AU<br />
Standard multimeter functions with 2 to 20mA sink and source capability,<br />
including a 24V supply. HART 250 resistor, 20mA drive into 1,200.<br />
Simultaneous mA and % of scale readout on mA output. 25% manual step<br />
plus auto step and auto ramp on mA output. Min/max/average/hold/relative<br />
modes. Double size dual display. Accuracy, VDC 0.1% +1, VAC 0.7% +2, mA<br />
DC 0.05% +2, frequency 0.005% +1.<br />
Halstrup KAL84 0-1kPa Portable<br />
Pressure Calibrator<br />
HAL,KAL84 (4792) AU<br />
Portable battery operated 0-1kPa (0-10mBar)<br />
low pressure calibrator. Linearity ±0.5% ±1<br />
digit, hysteresis 0.1%, medium - air and all non<br />
aggressive gases, pressure connections 6.5mm hose NW5, interior tubing<br />
5mmØ. Analogue output 0 to 1V, display 4.5 digit, power supply via mains<br />
adaptor 100 to 240VAC & NiCd rechargable battery pack.<br />
Jofra DPC-500 Documenting Pressure<br />
Calibrator 1000Bar NATA<br />
JOF,DPC-1000-NATA (4782) AU<br />
Documenting pressure calibrator is used for<br />
high precision calibration of pressure gauges,<br />
pressure transmitters, digital manometers,<br />
pressure switches, overpressure protection valves<br />
etc. Measure pressure at 1,000Bar or 14,500psi, voltage 0 to 10V, current<br />
0 to 20mA and 4 to 20mA, and supplies 24VDC as source for transmitters.<br />
Accuracy ±0.025% F.S. Supplied with Druck PV212 1000Bar hand pump<br />
and calibration software. 15 user selectable engineering units including user<br />
defined. Nata Calibrated.
www.techrentals.com.au<br />
Industrial Process Calibrators cont’d.<br />
Ralston Pressure Pump 350Bar Pump only<br />
RAL,XHGV-350 (4786) AU<br />
Pressure pump, operate with hydraulic oil. Pumps to 350Bar.<br />
SI PC6 20 bar NATA Pressure Calibrator & Pump<br />
SI,PC6-20-NATA (4774) AU<br />
Basic accuracy 0.025%. Range output pressure to 20Bar, output vacuum<br />
to -1Bar. NATA certified Instrument. Measures voltage 0~100mV (1μV<br />
resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) and current<br />
0~50mA (1μA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />
resolution) & 0~50mA (1μA resolution) also at 0.025% accuracy. Voltage<br />
output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />
±10% current 50mA. Pressure switch status. Battery operation 10h or mains<br />
operation via charger.<br />
SI PC6 35 bar NATA Pressure Calibrator & Pump<br />
SI,PC6-35-NATA (4775) AU<br />
Basic accuracy 0.025%. Range is 35 bar. Measures voltage 0~100mV (1μV<br />
resolution), 0~5V (0.1mV resolution) & 0~50V (1mV resolution) & current<br />
0~50mA (1μA resolution) all at 0.025% accuracy. Sources 0~10V (0.2mV<br />
resolution) & 0~50mA (1μA resolution) also at 0.025% accuracy. Voltage<br />
output regulated 10V ±0.1% current 30mA and unregulated supply 24V<br />
±10% current 50mA. Pressure switch status. Complete with a full range of<br />
pressure connection adaptors. Record logging capability 444 and RS232<br />
interface download to spread sheet files. Battery operation 10h or mains<br />
operation via charger.<br />
SI PC6-40-NATA Pressure Calibrator & Pump NATA Certified<br />
SI,PC6-40-NATA (4775) AU<br />
Basic accuracy 0.025%. Range is 40Bar. Measures voltage 0 to 100mV (1μV<br />
resolution), 0 to 5V (0.1mV resolution) & 0 to 50V (1mV resolution)<br />
& current 0 to 50mA (1μA resolution) all at 0.025% accuracy.<br />
Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1μA resolution)<br />
also at 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />
30mA and unregulated supply 24V ±10% current 50mA.<br />
Pressure switch status. Complete with a full range of pressure connection<br />
adaptors. Record logging capability 444 and RS232 interface download to<br />
spread sheet files. Battery operation 10h or mains operation via charger.<br />
SI PC6 700Bar Pressure Calibrator<br />
& HTP1 Hydraulic Pump NATA Calibrated<br />
SI,PC6-700-NATA (4781) AU<br />
SI,PC6-700 MY<br />
Range 0 to 700Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV<br />
resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all<br />
@ 0.025% accuracy. Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1uA<br />
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1% current<br />
30mA and unregulated supply 24V ±10% current 50mA. Pressure switch<br />
status. Pressure media oil, water & non corrosive gases. Battery operation<br />
10h or mains operation via charger.<br />
SI PC6-PRO 350Bar Pressure Calibrator & HTP1 Hydraulic Pump<br />
SI,PC6-PRO 350 MY<br />
Range 0 to 350Bar. Measures 0 to 100mV (1μV resolution), 0 to 5V (0.1mV<br />
resolution), 0 to 50V (1mV resolution) & current 0 to 50mA (1μA resolution) all<br />
@ 0.025% accuracy. Sources 0 to 10V (0.2mV resolution) & 0 to 50mA (1μA<br />
resolution) @ 0.025% accuracy. Voltage output regulated 10V ±0.1%<br />
current 30mA & unregulated supply 24V ±10% current 50mA. Pressure<br />
switch status. Pressure media oil, water & non corrosive gases. Battery<br />
operation 10h or mains operation via charger. Complete with a full range of<br />
pressure connection adaptors.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
51<br />
Dry Block Calibrators<br />
Grant W6 Temperature Bath NATA Certified<br />
GRA,W6-NATA (4744) AU<br />
Water/oil bath calibrator for calibrating temperature<br />
probes. Ranges water ambient 100ºC; silicon oil ambient;<br />
150ºC. Requires 3L oil (not supplied). Digital temperature<br />
controller and display. Stability 0.004ºC. Uniformity<br />
0.01ºC. Display resolution 0.1ºC. Tank size 300mm W x<br />
150mm D x 150mm H.<br />
Hart 9107 Dry Block Temperature Calibrator -45 to 140ºC NATA<br />
HAR,9107-NATA (4736) AU<br />
Range -45 to 140ºC, accuracy ±0.1°C, resolution 0.01°C, stability ±0.02°C.<br />
RS232 interface for ramp and soak programming. Well dimensions 150mm<br />
deep, 19, 5, 3 & (2x) 6mmØ. Heats and cools in less than 10min. NATA<br />
certified.<br />
Hart 9141 Dry Block Temperature Calibrator 50 to 650ºC<br />
HAR,9141-NATA (4738) AU<br />
HAR,9141 MY<br />
Range 50 to 650°C, basic accuracy 0.5%. Insert hole sizes 1.6mm(1/16”),<br />
3.2mm(1/8”), 4.8mm(3/16”), 6.4mm(1/4”), 9.5mm(3/8”) and 12.7mm(1/2”).<br />
Includes PC software and interface cable. Heating time 1min to 650°C.<br />
Cooling 25min from 650 to 100°C. Well depth 4.875”. Stabilization time 7min.<br />
Hart 9150 Furnace 150-1200ºC<br />
HAR,9150 (4739) AU<br />
Temperature range 150 to 1200ºC. Stability ±0.5ºC,<br />
display accuracy of ±5ºC across entire range. Display<br />
resolution 0.1º to 999.9ºC, 1º above 1,000ºC. Well<br />
diameter 1.25”, well depth 5.5”, insert type A. 1/16”, 1/4”,<br />
3/8”, 3/16”, 1/8”, 1/2”. Heating time 35min to 1,200ºC,<br />
cooling time 140min.<br />
Hart 9170-R Dry Block Temp Calibrator -45 to 140°C<br />
HAR,9170-R-NATA (4732) AU<br />
Temperature range -45 to 140°C with built in reference<br />
thermometry. Reference input accepts (not supplied)<br />
100, 25 and 10 ohm PRT’s. Display accuracy ±0.1°C,<br />
stability ±0.005°C full range, resolution 0.001°C. Well<br />
depth 160mm (6.3”), insert type A, 3 x 6.4mm(1/4”),<br />
4.8mm(3/16”), 3.2mm(1/8”), 5.9mm(3/8”). Large LCD,<br />
numeric keypad and on screen menus.<br />
Jofra CTC-1200A Temperature<br />
Calibrator<br />
JOF,CTC-1200A MY<br />
Compact temperature calibrator. Lightweight, portable for<br />
lab and general use. Temperature range: 572 to 2200ºF<br />
(300 to 1205ºC). Excellent Performance Characteristics.<br />
Accuracy: +/-4.0ºF (+/-2.0ºC). Stability: +1.0ºF (+0.5ºC).<br />
Stability Time: 20 minutes. Display in F or C to 0.1 resolution. Fast cooling and<br />
heating. User-selectable Slope Rates for controlled. Thermo switch testing.<br />
Self Diagnostics includes Semi-Auto Switch Test and Hysteresis Test. Size of<br />
thermowell/insert: 6.5mm & 10mm. 1/4” probe. 1/2” probe.<br />
Jofra C650 Calibrator<br />
JOF,C650 MY<br />
A fast, timesaving, and reliable true temperature<br />
calibrator designed for on-site use. Produces<br />
temperatures between 33 to 650°C. Display resolution<br />
±0.1°C, accuracy ±0.9°, stability 0.1°C. Well depth<br />
120mm x 28Ømm. Comes with a multi-hole insert of<br />
3/2”,1/4”, 3/16” & 1/8” Ø holes. Light weight and portable.
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Strip Chart <strong>Recorders</strong><br />
Yokogawa 3057-22 2 Pen Portable Recorder<br />
YEW,3057-22 (4011) AU<br />
Twelve input ranges 10mV to 50V fs, 150mm x 15m Z fold or roll chart, speeds<br />
20mm/h to 600mm/min. Accuracy 0.5%. <strong>Power</strong> 240/50Hz, rechargeable<br />
NiCad battery or 12VDC external.<br />
Yokogawa 3712-31 3 Pen Vertical Chart Recorder<br />
YEW,3712-31 (4004) AU<br />
Input ranges DC voltage 10mV to 200V fs. Thermocouples including type T &<br />
K. Chart speed 10mm/h to 20mm/s. Pen offset compensation. Memory card<br />
optional.<br />
Yokogawa 3712-41 4 Pen Vertical Chart Recorder<br />
YEW,3712-41 (4006) AU<br />
Input ranges: DC voltage 10mV to 200V fs. Thermocouples including type T &<br />
K. Chart speed 10mm/h to 20mm/s. Pen offset compensation. Memory card<br />
optional.<br />
Yokogawa 3750 10 Channel Multipoint Recorder<br />
YEW,3750 (4009) AU<br />
Ten channel hybrid recorder. Input ranges DC 20mV to 20V,<br />
thermocouple, RTD. Scans 10 channels in 2s. AC mains operation.<br />
Yokogawa DR130 Hybrid 20 Channel Recorder FDD<br />
YEW,DR130 (4010) AU<br />
Includes 3.5” FDD. Input unbalanced floating 20mV to 50VDC, TC, RTD and<br />
contact. Accuracy 0.05%. Reads 20 channels in 2s. Recording width 150mm.<br />
Data can be saved to 500k of internal RAM either directly or due to alarm<br />
conditions. The saved data can be copied to a 3.5” FDD file suitable for<br />
inclusion in standard spreadsheet programmes.<br />
High Speed Waveform <strong>Recorders</strong><br />
Sandisk Compact Flash Card 512MB with PCMCIA Adaptor<br />
COM,FLASH512MB (4160) AU<br />
Compact Flash Card 512Mb type 1 with PCMCIA Adaptor.<br />
Hioki 8826 32 Channel Memory<br />
Recorder with all Isolated Inputs<br />
HIO,8826-32CRECORDER (4151) AU<br />
32 channel recorder with all isolated inputs.<br />
400V dc input range. Simultaneous sampling,<br />
display and recording of all 32 analogue and<br />
32 logic channels. Large capacity memory of<br />
max. 16M word Memory expandable four times (option). High resolution of<br />
12bit, 1M sampling/second. B4 size (paper width 264mm) wide printer. Highvisibility<br />
waveforms displayed on a 10.4” colour TFT liquid crystal display.<br />
Hioki 8835 4 Channel<br />
Waveform & 16 Channel<br />
Memory Recorder<br />
HIO,8835 (4116) AU<br />
Memory 12bits x 100k per<br />
channel or 500k for a single<br />
channel. Analogue input channel<br />
ranges 10mV to 50V/div, 10X div, 400VDC, 240VAC RMS max. Inbuilt<br />
FDD and type-III PC card slot. Fastest sampling rate 1MHz.<br />
Paper 110mm x 30m. Colour TFT display. Additional functions include<br />
waveform parameter calculation including RMS values, area value, rise and<br />
fall times. AC mains operation.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
52<br />
www.techrentals.com.au<br />
High Speed Waveform <strong>Recorders</strong><br />
cont’d.<br />
Hioki 8835-01 4 Analogue,<br />
16 Logic Channel<br />
Waveform Recorder<br />
HIO,8835-01 (4128) AU<br />
Memory 12 bits x 1 megaword per<br />
channel or 4 megaword for a single<br />
channel. Analogue input channel ranges 10mV to 50V/div, 10X div, 400VDC,<br />
240VAC RMS max. In-built FDD & type-III PC card slot. Fastest sampling rate<br />
1MHz. Paper 110mm x 30m. Colour TFT display. Additional functions include<br />
waveform parameter calculation including RMS values, area value, rise and<br />
fall times. AC mains operation. Logic probes must be rented separately.<br />
Hioki 8835-HD520 520Mb PCMCIA Hard Disk for HIO,8835 & 8841<br />
HIO,8835-HD520 (4122) AU<br />
PCMCIA interface complete with 520Mb card. Data can be stored in several<br />
formats: as a binary memory file for replay on the recorder; as a CSV text file<br />
compatible with Excel; as a BMP screen dump for a Word document, etc; as<br />
a single or dual FFT binary file for replay on the recorder. The recorder setup<br />
can be saved for future applications requiring the same settings. Data media<br />
is PCMCIA Type III compatible with many laptop computers.<br />
Hioki 8841 8 Analogue, 16<br />
Channel Memory Recorder<br />
HIO,8841 (4117) AU<br />
Memory 12bits x 4 megawords/ch<br />
for 2 analogue ch, to 1 megawords/<br />
ch for 8ch. In-built FDD, type III<br />
PCMCIA card slot (for flashcard<br />
& HDD up to 520Mb). Sampling rate of 1MHz max. Functions memory,<br />
real time record, RMS, real time/memory, X-Y memory, FFT. Trigger<br />
functions level, window in, window out, voltage drop, RMS level,<br />
cycle, logic pattern trigger 1,0 or X (disregard). When using logic channels,<br />
logic probes must be rented separately. Measurement range 400VDC, 240V<br />
RMS, low pass filters 5Hz, 500Hz, 5kHz or 100kHz, input coupling DC, GND,<br />
AC. Large 10.4” colour TFT display for settings and waveform display, wide<br />
thermal printer fitted. On screen help function. All settings and waveforms<br />
can be saved to media, waveforms can be saved as binary, text or bmp files.<br />
Hioki 8842 16 Analogue, 16<br />
Logic Channel Waveform<br />
Recorder<br />
HIO,8842 (4150) AU<br />
Memory 12bits x 16 megawords/ch for<br />
2 analogue ch, to 2 megawords/ch for<br />
16 ch. Analogue input channel ranges<br />
10mV to 50V per div, 10X div, 400VDC, 240VAC RMS max. In-built FDD,<br />
type III PCMCIA card slot (for flashcard & HDD up to 520Mb). Sampling rate<br />
of 1MHz max. Functions memory, real time record, RMS, real time/memory,<br />
X-Y memory. Trigger functions level, window in, window out, voltage drop,<br />
RMS level, cycle, logic pattern trigger 1,0 or X (disregard). When using logic<br />
channels, logic probes must be rented separately. Measurement range<br />
400VDC, 240V RMS, low pass filters 5Hz, 500Hz, 5kHz, or 100kHz, input<br />
coupling DC, GND, AC. Large 10.4” colour TFT display for settings and<br />
waveform display, wide thermal printer fitted. On screen help function. All<br />
settings and waveforms can be saved to media, waveforms can be saved as<br />
binary, text or bmp files.<br />
Hioki 8860 8 Channel High Speed Memory<br />
Recorder<br />
HIO,8860 (4129) AU<br />
High speed memory recorder, 20MS/s sampling<br />
rate, 8 analogue channels, 16 logic channels,<br />
built in printer. 512MW or direct access memory,<br />
60GB hard drive built-in, PC card type II slot<br />
up to 4GB ATA flash card (optional) USB, LAN<br />
interface and large colour screen.
www.techrentals.com.au<br />
High Speed Waveform <strong>Recorders</strong><br />
cont’d.<br />
Hioki 8870-20 Memory Hicorder 2<br />
Analogue & 4 Logic Channels<br />
HIO,8870-20 (4101) AU<br />
Channels; 2 analogue and 4 logic (standard<br />
equipment, logic grounds are common<br />
with instrument ground), 10mV to 50V/<br />
div, 12 ranges, resolution: 1/100 of range,<br />
DC 400V, DC to 50kHz (-3dB). 100μs/<br />
div to 5 min/div, 20 ranges, at 100 points/<br />
div resolution, three steps of time-axis magnification from 2× to 10×, and<br />
nine steps of time-axis compression from 0.5× to 0.001. MEM (high-speed<br />
recording), 12bits × 2M-Words/ch, CF Card Type I slot × 1, up to 1GB. Display<br />
4.3-inch WQVGA-TFT colour LCD (480 × 272 dots). One USB 2 high speed<br />
mini-B receptacle: transfers files from the installed CF card to a PC when<br />
connected. Numerical calculation, cursor readout, scaling function, screen<br />
copy, gauge display, waveform data/setting configurations backup, start<br />
condition retention, auto-save, instantaneous value or RMS value display<br />
(only DC and 50/60Hz). Use with the AC adapter, 100 to 240VAC (50/60Hz)<br />
30VA max. Battery pack; continuous use 2h (AC adapter has priority when<br />
both are used). 12VDC supply: 10 to 16V, 10VA Max.<br />
Hioki 8938 FFT Input Signal<br />
Module<br />
HIO,8938 (4138) AU<br />
FFT Module with anti-aliasing filter.<br />
Frequency range DC to 400kHz,<br />
sampling rate 1MS/s. Maximum input<br />
voltage 400VDC, 240V RMS.<br />
Hioki 9305 Trigger Cord for Hioki Memory <strong>Recorders</strong><br />
HIO,9305 (4135) AU<br />
Plug each end of cable 3.5mm. Trigger cord enables master slaving of the Hioki<br />
8835, 8810 and 8811 memory recorders. One end connected to the trigger<br />
output socket of master recorder the other end connects to the trigger input<br />
socket of the second recorder which is the slave. Trigger pattern set up for the<br />
master and the slave recorder set just to external trigger.<br />
Hioki 9306 4 Channel Contact & Digital Logic Probe<br />
HIO,9306 (4123) AU<br />
Contact interface for HIO, 8811, 8835, 8835-01, 8841 & 8842 memory<br />
recorders. Threshold digital >1.4V maximum input 50V. Contact closure input,<br />
2k input resistance 30V allowable input. Response time 2μs.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Hioki 9320 4 Channel Contact &<br />
Digital Logic Probe<br />
HIO,9320 (4140) AU<br />
For HIO, 8811, 8835, 8835-01, 8841 &<br />
8842 memory recorders, 4 channels<br />
per probe, max of 4 probes per<br />
recorder. Threshold digital selectable<br />
1.4V, 2.5V & 4V. Response time 500ns<br />
max. Relay dry contact detection. Max<br />
allowable input 50VDC.<br />
Hioki 9321 Line Logic Probe<br />
HIO,9321 (4124) AU<br />
Four channels (insulated) per probe.<br />
Detection of 60 to 150VAC, 170 to<br />
250VAC, 20 to 150VDC & 70 to 250VDC<br />
in 2 ranges. Response time slope rise<br />
1ms, fall 3ms. Max input low range<br />
150V RMS, high range 250V RMS.<br />
Max rated voltage to earth 250V RMS.<br />
Connector cable 1.5m. Probe tip cable 1m.<br />
53<br />
High Speed Waveform <strong>Recorders</strong><br />
cont’d.<br />
Hioki 9335 Wave Processor Software for Hioki 8835, 8835-01,<br />
8841, 8842<br />
HIO,9335 (4155) AU<br />
Waveform Processor software, displays, converts to CSV, calculates and<br />
prints waveforms with a PC. Review stored binary files from Hioki 8835,<br />
8835-01, 8841 and 8842 memory recorders. Only way stored binary files can<br />
be viewed on a PC without having to re save them with memory recorder as<br />
text files.<br />
Hioki 9725 Memory Viewer Software<br />
HIO,9725 (4157) AU<br />
Data processing software for Hioki 8860 High Speed Memory Recorder.<br />
Functions: file loading, maximum loadable data size 2GW file saving,<br />
measurement of data binary, partial saving between A/B cursors is<br />
possible. Screen images BMP and PNG, calculation results. Display of<br />
saved binary files, displayable channels per sheet analogue 32, logic 16<br />
channels. Displayable sheets 16.<br />
Data Loggers<br />
Compact Flash card 64MB with PCMCIA adaptor<br />
COM,FLASH64MB (4239) AU/MY<br />
64MB Compact Flash card with PCMCIA card adaptor.<br />
Datataker CANGATE Gateway &<br />
Garmin 5Hz GPS<br />
DE,CANGATE (4236) AU<br />
Interface to allow dataTaker loggers and PC<br />
(via RS232) to access CANBUS networks<br />
including J1939 & OBD2. The device also<br />
includes a Garmin 5Hz GPS system.<br />
DataTaker DT600 Data Logger<br />
DE,DT600 MY<br />
Includes LCD display enabling use as a measuring instrument if<br />
pre-programmed for channel parameters. 10 differential or 30 single-ended<br />
channels. 25 channel/sec. 4 TTL/CMOS digital inputs. 3 counter channels up<br />
to 1MHz. Up to 120 alarms with 1 digital I/O and 3 front panel LEDs. Internal<br />
memory for up to 13,000 data points with optional memory card to 170,000<br />
readings. RS-232C data communications port and RS-485 port for networking<br />
up to 32 loggers. Maths processing included. Input ranges 25mV to 2.5VDC.<br />
Maximum sensitivity 2μV. Current 0.25 to 25ma. Current loop 4-20mA.<br />
Resistance up to 7,000 ohms. Thermocouples types B,C,D,E,G,J,K,N,R,S, &<br />
T from -250 to 1800ºC. Thermistors and RTD’s. Strain gauges. Supplied with<br />
determinal & decipher plus software. Operates from internal battery, external<br />
battery, or ac mains.<br />
DataTaker DT80M 5 to 15 Channel Logger<br />
with USB Memory Stick Download<br />
DE,DT80 (4232) AU<br />
Measures voltage, current, resistance and frequency. Up to 15 analogue<br />
(±30V) sensor inputs. Each channel is independent and supports: one<br />
isolated 3-wire or 4-wire input, or two isolated 2-wire inputs, or three common<br />
referenced 2-wire inputs. 12 flexible digital channels. Expandable to 300<br />
analogue inputs. Store up to 10 million data points in user defined memory.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Data Loggers cont’d.<br />
DataTaker DT80M 5<br />
to 15 Channel Logger<br />
with Built in Modem<br />
DE,DT80M (4234) AU<br />
Includes a built in GSM modem for internet<br />
access to the device. Measures voltage, current,<br />
resistance and frequency. Up to 5 analogue (±30V) sensor inputs. Each<br />
channel is independent and supports: one isolated 3-wire or 4-wire input,<br />
or two isolated 2-wire inputs, or three common referenced 2-wire inputs.<br />
Store up to 10 million data points in user defined memory. Generally used at<br />
frequencies of 1Hz and slower.<br />
DataTaker DT800 Data Logger<br />
DE,DT800 (4231) AU/MY<br />
Universal input channels 12<br />
balanced or 42 unbalanced analogue<br />
channels. Eight bi-directional digital channels<br />
and 8 digital input channels. Solid state multiplexer protected to ±40V. Max<br />
in/out voltage ±12V. Serial sensor channel can be used with GPS systems.<br />
Measures V, 4 to 20mA, strain, TC, RTD etc. Sampling rate 200Hz up<br />
to 100kHz in burst mode. Instrument has RS232, RS422, USB, Ethernet<br />
(10baseT) & PC card modem communications. Pluggable 64Mb memory<br />
card stores up to 300,000 (compressed) readings per Mb. Instrument stores<br />
600,000 (compressed) readings in internal memory. Total memory capacity<br />
10.2Mb (compressed).<br />
Datataker DT85 48 Channel Logger with<br />
USB Memory Stick Download<br />
DE,DT85 (4233) AU<br />
Analogue inputs 32 isolated and 48 single<br />
ended inputs. 2 x 4 digital input types. 2 x<br />
serial sensor ports, Modbus capability, 4 x SDI12 channels, USB memory<br />
stick interface for easy data and programming etc. Operating time on the<br />
internal battery is 1s sample 2.4h. 5s sample 3 days, 1min sample 1 month.<br />
Ebro Bowie Dick Autoclave Logger<br />
EBR,EBI125A-BD-3 (4250) AU<br />
Autoclave logger designed to be placed inside an autoclave and provide the<br />
pass/fail criteria. The logger includes an internal pressure transducer 0~5<br />
bar, and two PT1000 RTD sensors. The operating temperature range is -40<br />
+125ºC. Resolution 0.1 deg C 1 mBar. Accuracy 0.3ºC +/- 1 digit, 25 mBar.<br />
Memory 3 x 6000 readings. Sample rate 1sec to 8 hrs. The system includes<br />
software to enable the download of measured values. To determine F0<br />
values a spreadsheet calculation is required.<br />
ETM 9900 Intelligent Modem and IO. Sends<br />
SMS Messages<br />
ETM,9900 (4290) AU<br />
Can send a user defined alarm message via SMS.<br />
Has 7 IO channels. Will provide alarm messages<br />
for instruments such as the ARL,NGARA,<br />
PRO,VIBRA & the TSI,8520 & 30. Will operate for around 4 months on 2xD<br />
cell batteries when the alarm status is checked once per hour. Can be put on<br />
site and remotely programmed.<br />
Fourier DAQPRO8 Batter Operated Hand Held 8<br />
Channel Data Logger<br />
FOU,DAQPRO-2 (4282) AU<br />
Portable, hand held, battery operated 8 channel data logger. 16-bit<br />
resolution, built in graphic LCD, for setting up, graphical display of logged data.<br />
PC communications via USB interface. Signal inputs 0 to 24mA, 0 to 50mV,<br />
<br />
range -200 to 400ºC, T/C ranges J type, -300 to 1500ºC, K type -250 to 1100ºC,<br />
T type -200 to 400ºC. Frequency input one channel only, 20 to 4,000Hz,<br />
sensitivity 20mV, pulse counter one input 0 to 65,000 counts. Memory<br />
capacity 512KB, sampling rates from 1s/h to 4,000s/s. Supplied with analysis<br />
and setting up software.<br />
54<br />
Data Loggers cont’d.<br />
www.techrentals.com.au<br />
Fourier Microlog Temp/Hum Logger Kit with Wireless Cradles<br />
FOU,MICROLOG-KIT (4263) AU<br />
Set of 5 temperature and humidity loggers mounted in RF<br />
transmitter cradles, one receiver for PC. Transmission range up to 300m<br />
or RS232C & USB interface also included if direct connection to PC for<br />
down loading required. Temperature range -30 to 50ºC, accuracy ±1º, 0 to<br />
100%RH accuracy ±3%RH, 2 digit LCD, memory capacity 16,000 data points<br />
between 2 channels. User defined sampling rate from 10s to 2h. MicroLog Plus<br />
management control software included to control and monitor all the loggers<br />
remotely on PC within transmission range.<br />
Hioki 3641-20 Temperature/Humidity Logger<br />
with RS-232C & USB<br />
HIO,3641-20 (4255) AU/MY<br />
Includes 1 x RS232C and 1 x USB communication base, utility software,<br />
RS232C and USB interface cables. Environment conditions for operation -20<br />
to 70ºC, 80%RH (no condensation). Accuracy: Temperature -20 to -0.1ºC<br />
±1.0ºC, 0.0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity typical<br />
between ±5 to ±10% depends on temperature and humidity range.<br />
Hioki 3641-20-Kit of<br />
8 Temperature & Humidity Loggers<br />
HIO,3641-20-KIT (4256) AU<br />
Kit of 8 x temperature and humidity loggers. Includes<br />
1 x RS232C and 1 x USB communication base,<br />
utility software, RS232C and USB interface cables.<br />
Environment conditions for operation -20 to 70ºC,<br />
80%RH (no condensation) Accuracy: Temperature -40 to<br />
-0.1ºC ±1ºC, 0 to 35ºC ±0.5ºC, 35.1 to 70ºC ±1ºC. Humidity typical between<br />
±5 to ±10% depends on temperature and humidity range. 8000 data points x<br />
2 channels, recording interval 2,5,10,15,20,30s and 1,2,5,10,15 ,20,30,60min.<br />
Hioki 8421-01 16 Channel Data Logger with Colour Display<br />
HIO,8421-01 (4270) AU<br />
16 analogue, 4 pulse input channels data logger with colour<br />
display, PCMCIA card slot, LAN interface built in, TCP/IP communication<br />
supports real time PC logging, FTP, SMTP and HTTP. Signal inputs 100mVDC,<br />
1VDC, 10VDC, 60VDC, 1 to 5VDC fs. Thermocouples K,E, J, T, N, W (WRe5<br />
to 26) R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100<br />
-200 to 800ºC. Pulse input, accumulation 50,000 counts fs, 500,000 counts<br />
fs, 5M counts fs, 100M counts fs, 2,500M counts fs. Rotation 5,000/n (r/s)<br />
fs. Recording interval is selectable from 100, 200, 500ms, 1, 2, 5, 10, 20,<br />
30s, 1, 2 & 5min. Max sampling rate is dependent upon type of input signal.<br />
Internal Memory 8Mb, 256Mb Flashcard, 9334 logger communicator<br />
software, 9642 LAN cable, 9641 pulse signal input cable all supplied.<br />
Hioki 8421-51 16 Channel Data Logger with Colour Display<br />
HIO,8421-51 (4271) AU<br />
16 analogue, 4 pulse input channels data logger with colour display, PCM-<br />
CIA card slot, LAN interface built in, TCP/IP communication supports real<br />
time PC logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1VDC,<br />
10 VDC, 60VDC, 1-5VDC f.s. Thermocouples K, E, J, T, N, W (WRe5-26),<br />
R, S, B, -100 to 100ºC, -200 to 500ºC, -200 to 2,000ºC, RTD Pt100 -200<br />
to 800ºC. Pulse input, accumulation 50,000C f.s, 500,000C f.s, 5MC f.s,<br />
100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s) f.s. Recording interval<br />
selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s, 10s, 20s, 30s, 1min,<br />
2min, 5min. Max sampling rate is dependent upon type of input signal.<br />
Internal Memory 16MW, 512MB PCMCIA FLASH card, 9334 Logger<br />
Communicator software, 9642 LAN cable, 9641 pulse signal input<br />
cable all supplied. Improved common mode rejection -100dB or better<br />
when 50/60Hz, 140dB or better when 50Hz, using ch1 to ch16, interval 5s,<br />
digital filter 50Hz selected. Faster sampling when using Pt100, improved<br />
temperature characteristics.
www.techrentals.com.au<br />
Data Loggers cont’d.<br />
Hioki 8422-51 32 Channel Data Logger<br />
HIO,8422-51 (4273) AU<br />
32 analogue, 4 pulse input channels data logger with colour display, PCMCIA<br />
card slot, LAN interface built in, TCP/IP communication supports real time PC<br />
logging, FTP, SMTP and HTTP. Signal inputs- 100 mVDC, 1 VDC, 10 VDC, 60<br />
VDC, 1-5V DC f.s. Thermocouples K,E, J, T, N, W (WRe5-26) R, S, B, -100 to<br />
100ºC, -200 to 500ºC, -200 to 2,000ºC, Pulse input, accumulation 50,000C<br />
f.s, 500,000C f.s, 5MC f.s, 100MC f.s, 2,500MC f.s. Rotation 5,000/n (r/s)<br />
f.s. Recording interval is selectable from 100ms, 200ms, 500ms, 1s, 2s, 5s,<br />
10s, 20s, 30s, 1min, 2min, 5min. Max sampling rate is dependent upon type<br />
of input signal. Internal Memory 8MB, 512MB PCMCIA FLASH card, 9334<br />
Logger Communicator software, 9642 LAN cable, 9641 pulse signal input<br />
cable all supplied.<br />
Hioki Kit of Three 9322 Differential Probe High Voltage<br />
True RMS Interface<br />
HIO,9322-KIT (4119) AU<br />
Used with many memory recorders, eg. Hioki 8835. Operating modes 3.<br />
DC mode for waveform monitor output DC to 3MHz, AC mode detection of<br />
power surge noise 1kHz to 10MHz. Rectified true RMS output of DC & AC<br />
voltages. 40Hz to 100kHz response speed 200ms or less. Max voltage DC<br />
2kV, AC 1kV CATII, AC/DC 600V CATIII, balanced differential input 1/1,000<br />
divider.<br />
Testo 177-H1 Logger with Display<br />
TES,177-H1 MY<br />
Parameters: humidity/temperature/dew point. Sensors: humidity sensor/<br />
NTC (internal). Number of channels: 4. Measuring range: 0 to 100%RH and<br />
-20 to 70ºC (internal). Memory: 48,000 readings.<br />
Testo 177-T4 Logger with Display<br />
TES,177-T4 MY<br />
Parameters: temperature (C/F). Sensors: thermocouple type-K. Number<br />
of channels: 4 (external). Measuring range: -100 to 1,000 ºC (external).<br />
Memory: 48,000 readings.<br />
Pressure & Humidity Transducers<br />
Druck PTX1400 4Bar Pressure Transducer<br />
DRU,PTX1400-4 (4307) AU<br />
Output 4 to 20mA. Requires 9 to 36VDC. Supplied with 12V<br />
plug pack. Pressure input connector G ¼” female.<br />
Druck PTX1400-25 25Bar Pressure Transducer 4 to 20mA<br />
DRU,PTX1400-25 (4302) AU<br />
Output 4 to 20mA output, 0 to 25Bar input. Requires 9 to 28VDC, supplied<br />
with 12V, 500mA power pack.<br />
Druck PTX1400 40Bar Pressure Transducer 4 to 20mA<br />
DRU,PTX1400-40 (4303) AU<br />
Output 4 to 20mA. Requires 9 to 36V DC, supplied with 12V plug pack.<br />
Druck PTX 1400 600Bar Pressure Transducer<br />
DRU,PTX1400-600 (4305) AU<br />
Output 4 to 20mA. Requires 9 to 32VDC, supplied with 12V plug pack.<br />
Fluke PV350 Vacuum/Pressure Indicator<br />
FLU,PV350 (4321) AU<br />
Can be used with a digital multimeter (eg Fluke 189)<br />
to act as an indicator. Range, pressure to 4137kPa<br />
and vacuum 0 to 76cmHg. Results in either psi or kPa.<br />
Connector ½”NPT (m). Cable 2.4m provided. Battery<br />
powered.<br />
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
55<br />
Pressure & Humidity Transducers<br />
cont’d.<br />
RS Type 461-313 Pressure Transducer Range<br />
-1 to 24Bar G<br />
RS,TYPE 461-313 (4301) AU<br />
Range -1 to 24Bar G. Output 4 to 20mA.<br />
Schaevitz P1241 10,000PSI 0 to 5V Pressure Transducer incl Snubber<br />
SHA,P1241-10000 (4322) AU<br />
10,000psi, includes snubber, 0 to 5V output.<br />
Schaevitz P3061-4D 4PSI Differential Pressure Transducer<br />
SHA,P3061-4D (4313) AU<br />
4psi. LVDT type with built-in amplifier. Output 0 to 5VDC. Operates from 10 to<br />
32VDC or AC mains.<br />
Trafag 8204 1Bar, 4 to 20mA, Differential Pressure Transducer<br />
TRA,8204-1D-20A (4311) AU<br />
Accuracy ±0.3% FS. Overpressure 10Bar. Output 4 to 20mA. Pressure<br />
connection G ¼” male. Bandwidth 1kHz. Media temperature 125ºC. IP65<br />
rated. <strong>Power</strong> supply 10 to 30V.<br />
Vaisala HMP 135Y 160ºC Humidity Probe<br />
VAI,HMP-135Y (4581) AU<br />
High temperature humidity and temperature transmitter. Sensor head<br />
operates from 0 to 180ºC. Measurement range 0 to 100%RH. Accuracy of<br />
1%RH at 20ºC. Output 0 to 5V DC. Other outputs easily set including 4 to<br />
20mA. Operates from 0 to 160ºC.<br />
Vaisala HMP 235Y 180ºC Humidity Probe<br />
VAI,HMP-235Y (4582) AU<br />
High temperature humidity and temperature transmitter. Sensor head<br />
operates from 0 to 160ºC. Measurement range 0 to 100%RH. Accuracy of<br />
1%RH at 20ºC. Output 0 to 5VDC. Other outputs easily set including 4 to<br />
20mA. Operates from 15 to 30V DC or AC mains.<br />
Vega Bar 20 0 to 1Bar Transducer with Display<br />
VEG,BAR20-1 (4314) AU<br />
Output 4 to 20mA. LCD display and is rated IP65. Over pressure resistant to<br />
10Bar & -1Bar. Measurement accuracy 0.5%, linearity deviation 0.085%. May<br />
be set to bar, psi, kpa, mpa,mmH 2 O, mH 2 O & mbar. Output can be 4 to 20mA<br />
or 20 to 4mA. Integration time 0 to 10s. Density factor may be entered for mm<br />
and m, output simulation indication module has 20 segment bar graph and 4<br />
digit display which may be scaled (has factory default reset). Supply required<br />
12 to 36VDC.<br />
Pressure Vacuum Gauges/<strong>Recorders</strong><br />
Bristol Babcock 10,000PSI Mech Chart Recorder<br />
BRI,10000-NATA (4328) AU<br />
Circular pressure chart recorder 10,000psi. 12”Ø. Accuracy ±0.5% NATA<br />
calibrated. Fitted with 2 speed spring wound chart drive giving 7d or 24h<br />
recording. Pressure connection ¼”NPT.<br />
Crystal XP2i Digital Logging Pressure<br />
Gauge 7Bar NATA calibrated<br />
CRY,XP2I-100-NATA (4341) AU<br />
Range 7Bar resolution 0.1mBar. Accuracy 1.4 to 7Bar<br />
±0.1% of reading. 0 to 1.4Bar ±1.4mBar. Vacuum<br />
±17.5mBar. Has a 6000 point logging capability. Logging<br />
intervals from 1s up can be set. Logs either actual<br />
pressure, average pressure or average pressure with
GENERAL INDUSTRIAL & PROCESS MEASUREMENT<br />
Pressure Vacuum Gauges/<strong>Recorders</strong><br />
cont’d.<br />
Crystal XP2i Digital Logging Pressure Gauge 20Bar<br />
NATA calibrated<br />
CRY,XP2I-300-NATA (4341) AU<br />
Range 20Bar resolution 1mBar. Accuracy 4 to 20Bar<br />
±0.1% of reading. 0 to 4Bar ±4mBar. It Has a 6000 point<br />
logging capability. Logging intervals from 1s up can be set.<br />
Logs either actual pressure, average pressure or average<br />
pressure with max and min. Also logs on demand.<br />
Crystal XP2i Digital Logging Pressure Gauge 70Bar NATA calibrated<br />
CRY,XP2I-1K-NATA (4342) AU<br />
Range 70Bar resolution 0.001Bar. Accuracy 14 to 70Bar ±0.1% of Reading<br />
0 to 14Bar ±14mBar. Has a 6000 point logging capability. Logging intervals<br />
from 1s up can be set. Logs either actual pressure, average pressure or<br />
<br />
Crystal XP2i Digital Logging Pressure Gauge 210Bar NATA calibrated<br />
CRY,XP2I-3K-NATA (4343) AU<br />
Range 210Bar resolution 0.01Bar. Accuracy 40 to 200Bar ±0.1% of reading. 0<br />
to 40Bar ±0.04Bar. Has a 6000 point logging capability. Logging intervals from<br />
1s up can be set. Logs either actual pressure, average pressure or average<br />
<br />
Crystal XP2i Digital Logging Pressure Gauge 700Bar NATA calibrated<br />
CRY,XP2I-10K-NATA (4344) AU<br />
Range 700Bar resolution. 0.01Bar accuracy. 1% of reading. Has logging<br />
capability. 6000 point pressure logging capability. Logging interval can be<br />
set from 1s up. Logs either Actual Pressure, Average Pressure, or Average<br />
<br />
connector.<br />
Floyd 160Bar 100mm Pressure Gauge<br />
FLO,PG 0-160BAR (4332) AU<br />
Analogue pressure gauge filled with fluid 0-160Bar 100mm 3/8”BSPT<br />
graduations 5Bar. Accuracy ±1% full scale definition.<br />
Floyd 250Bar 100mm Pressure Gauge<br />
FLO,PG 0-250BAR (4333) AU<br />
Analogue pressure gauge filled with fluid 0-250Bar 100mm 3/8”BSPT<br />
Graduations 10Bar. Accuracy ±1% full scale definition.<br />
Keller Mano Digital Pressure Gauge<br />
KEL,MANORECORD (4342) AU<br />
Microprocessor controlled pressure gauge. Displays pressure and<br />
temperature. Logging capability with RS232 download. 0 to 30Bar range<br />
±0.1% of range accuracy (@ 20°C).<br />
Flow Meters for Liquids & Gases<br />
See also Environmental Flow Meters on page 76<br />
Flexim Ultrasonic Gas<br />
Flow Meter<br />
FLE,G608 (6156) AU<br />
Transit time ultrasonic gas flow meter includes a<br />
built in datalogger. Supplied with GLK, GLM & GSM<br />
transducers and thickness gauge. The GLK will do<br />
4~9mm wall thickness, GLM 2~5mm wall thickness<br />
& the GSM 2.5mm and greater. This uses one of either two technologies to<br />
generate a signal, either Shear wave or Lamba wave. The shear wave is the<br />
normal technique. The Lamba wave involves creating a resonance on the<br />
surface of the pipe thus greatly increasing the signal strength the effect of<br />
this is that for gas measurement it will operate at significantly lower pressures<br />
than the standard Shear wave instruments. Can also be used to measure<br />
liquid flow.<br />
56<br />
www.techrentals.com.au<br />
Flow Meters for Liquids & Gases<br />
cont’d.<br />
Panametrics 12 to 50mm Transducers<br />
PAN,C-LP-40NM (6108) AU//MY<br />
Transducer pair for PAN,PT868/878 transit-time flowmeter to suit pipe 12 to<br />
50mmØ. Complete with CF-LP-50M mounting bracket. Temperature range<br />
-40 to 120°C.<br />
Panametrics -20 to 210°C Transducers<br />
PAN,C-PT-10HB (6110) AU<br />
High temperature transducer pair for PAN,PT868/878 transit-time flowmeter.<br />
Operates on pipe sizes 50mm to 2mØ. Working temperature range -20 to<br />
210°C.<br />
Gas-flow Small Pipe Transducer Kit for PT878GC<br />
PAN,GC-RL302 (6153) AU<br />
Advanced clamp-on ultrasonic transducer pair for use with Panametrics gas<br />
flowmeters. Operation at 1MHz for pipes in the range 20 to 55mm typical.<br />
General purpose use for process temperatures -40 to 176°C. Supplied with<br />
two precision gauged clamping fixtures for pipe range.<br />
Gas-flow Medium Pipe Transducer Kit for PT878GC<br />
PAN,GC-RL319 (6155) AU<br />
Advanced clamp-on ultrasonic transducer pair for use with Panametrics gas<br />
flowmeters. Operation at 500kHz for pipes in the range 75-300mm typical.<br />
General purpose use for process temperatures -40 to 176°C. Supplied with<br />
set of three precision gauged clamping fixtures for pipe range.<br />
Panametrics -200 to 400°C Transducers<br />
PAN,OKS (6112) AU<br />
Very high temperature, wide range transducer pair for PAN,PT868/878<br />
transit-time flowmeter. Temperature range -200 to 400°C, for pipe 80mm to<br />
600mmØ. Uses special clamp system supplied. Appropriate protection and<br />
safe-handling equipment is required for fitting and operation at very high or<br />
low temperatures.<br />
Panametrics PT878<br />
Ultrasonic Flowmeter<br />
PAN,PT878 (6101) AU/MY<br />
Portable non-contact liquid flowmeter<br />
using transit-time principle. Includes<br />
transducers for pipe 50mm to 2mØ &<br />
temperatures -40 to 130°C (various<br />
alternative transducers available) with<br />
clamping fixture. Flow velocity range<br />
0.03 to 12.2m/s. Accuracy typically 1%.<br />
Data logging for over 100K data points.<br />
Analogue inputs compatible with temperature transmitters for energy-flow<br />
calculations. Outputs analogue 4 to 20mA, digital (pulse or frequency) and<br />
printer/computer (Infrared port). Large LCD display for velocity, volumetric and<br />
energy flow rate, totalised flow and trend data in alphanumeric and graphical<br />
formats. Rechargeable NiMH batteries and AC power supply/charger.<br />
See also GLO,FP101 Global FP101 Digital Water Velocity Meter<br />
on page 76<br />
Panametrics PT878E Ultrasonic Liquid Flow Energy Meter<br />
PAN,PT878E (6102) AU<br />
Portable non-contact liquid flowmeter using transit-time principle.<br />
Includes transducers to measure energy and transducers for pipe 50mm to<br />
2mØ & temperatures -10 to 130°C (various alternative transducers available)<br />
with clamping fixture. Flow velocity range 0.03 to 12.2m/s. Accuracy typically<br />
1%. Data logging for over 100K data points. Outputs analogue 4 to 20mA,<br />
digital (pulse or frequency) and printer/computer (Infrared port). Large LCD<br />
display for velocity, volumetric and energy flow rate, totalised flow and trend<br />
data in alphanumeric and graphical formats. Rechargeable NiMH batteries<br />
and AC power supply/charger.
www.techrentals.com.au<br />
Flow Meters for Liquids & Gases<br />
cont’d.<br />
GE Panametrics PT878GC Ultrasonic Gas Flow Meter<br />
PAN,PT878GC-01 (6151) AU<br />
Portable non-contact gas flowmeter using transit-time principle. For<br />
operation with ultrasonic transducer-kits (PAN,GC-RL302 & PAN,GC-<br />
RL319) - available separately. Compatible with metal or plastic pipes in the<br />
range 20 to 300mm. Suitable for use with compressed air, natural gas and<br />
other gases. Readout for flow velocity, actual or standard volumetric flow or<br />
mass-flow in numerical or graphic format. Internal logging for 100K flow data<br />
points. Infrared communications port for download to PC or printer interface.<br />
Rechargeable battery for 8h continuous operation.<br />
Polysonics Hydra SX30 Dual<br />
Frequency Doppler Liquid Flowmeter<br />
POL,HYDRA-SX30-2 (6132) AU<br />
Dual frequency doppler ultrasonic non-contact<br />
flowmeter. Velocity range 0.06 to 10m/s, accuracy<br />
±1%. Pipe size range 12 to 5,000mm diameter. Data<br />
logging for 90,000 points, with PC software and<br />
interface cable for download via RS232C interface.<br />
Transducer temperature range -40 to 122°C.<br />
Analogue output 4 to 20mA. Battery operated, 12h<br />
continuous use (8h recharge).<br />
Combustion, Flue & Industrial<br />
Gas <strong>Analysers</strong><br />
See also Environmental Gas & Vapour Meters on page 70-71<br />
Novatech O 2 and CO 2 Analyser/Transmitter<br />
NOV,1637-5 (5954) AU<br />
Oxygen and carbon dioxide analyser for packaging<br />
atmosphere, general industrial and research use.<br />
Oxygen sensor reading 1ppm to 100% with 1%<br />
accuracy. NDIR carbon dioxide analysis 0 to<br />
100% ±3% of full scale. 2 x 4 to 20mA outputs,<br />
1 common & 3 selectable alarm relays. Gas connection 1/8 Swagelok. Flow<br />
rate with internal pump 100 to 500cc/min. AC operation.<br />
Novatech O 2 & CO 2 Combustion Gas Analyser<br />
NOV,1637-5CGA (5926) AU<br />
Oxygen and carbon dioxide analyser for flue gas/<br />
combustion gas applications. Special version of<br />
model 1637-5, with steel transfer tubing, closed IR<br />
cell (sapphire windows) and ruggedised internal<br />
flow path. Fitted with filtration system for moisture<br />
protection. 240V, 50Hz.<br />
Testo 300M Combustion Gas<br />
Analyser<br />
TES,300M MY<br />
Flue gas analyser for combustion efficiency<br />
measurement. Temperature range -40 to 1200°C<br />
±0.5 (100) with gas probe<br />
operation to 1,000°C max. Draught/pressure<br />
range 80mBar, ±0.03. Gases measured: O 2 0<br />
to 21%, ±0.2%; CO 2 [calculated] 0 to CO 2 max<br />
vol ±0.2%; CO 0 to 8,000ppm, ±20 (
PHYSICAL MEASUREMENT<br />
Material Hardness Testers<br />
Non-Destructive Testing<br />
Micrometers<br />
Position Transducers<br />
Inclinometers<br />
Force Gauges<br />
Load Cells<br />
Weighing & Counting Scales over 8kg<br />
Vibration Analysis<br />
Speed Measurement<br />
Material Hardness Testers<br />
Krautkramer DynaPocket<br />
Rebound Hardness Tester<br />
KRA,DYNAPOCKET (4932) AU<br />
Based on the Leeb’s method HL,<br />
utilising a 3mm tungsten carbide<br />
ball. Other hardness scales can<br />
be selected, HS Shore, HB Brinell, HRB Rockwell B, HRC Rockwell C, HV<br />
Vickers and N/mm 2 tensile strength. Choice of 9 material groups can be<br />
selected, they are St Low-alloy/unalloyed steel and cast steel, ASt Tool steel,<br />
SSt Corrosion resistant steel, GCI Gray cast iron, NCI Nodular graphite cast iron,<br />
AL Aluminium cast alloys, brS Brass, brZ Bronze, Cu Wrought copper alloys.<br />
Proceq Equotip Hardness Tester<br />
PRO,EQUOTIP (4931) AU<br />
Test probe on a flexible lead. Probe type D is<br />
standard catering for most materials. Measurement<br />
ranges steels 80 to 650HB, 80 to 940HV, 20 to<br />
68HRC, aluminium castings 20 to 160HB, cast iron<br />
90 to 380HB, brass 40 to 170HB & copper wrought alloys 43 to 315HB. Test<br />
hardness must not exceed 940HV. Battery operated.<br />
Non-Destructive Testing<br />
Defelsko FNS2 Ferrous & Non Ferrous Coating<br />
Thickness Tester<br />
DEF,FNS2 (4802) AU<br />
Storage of up to 250 readings. Supplied with external probe,<br />
calibration standards and carry pouch. Measurement<br />
range 0 to 1500μm or 0 to 60mils (selectable), tolerance<br />
0 to 50mm ±1mm, +1% of reading, greater than 50mm<br />
±2μm, +1%, resolution 0.1mm. Back glow display, HiLo<br />
limits audible and visible alerts when measurements exceed specified limits.<br />
Continually displays updates average, standard deviation, min/max thickness<br />
and number of readings while measuring. Hi resolution mode for greater<br />
precision. Built in infra red port for down loading data.<br />
PosiTector 200 B & C Ultrasonic<br />
Coating Thickness Gauge<br />
DEF,POS-200ADV (4805) AU<br />
Ultrasonic coating thickness gauge with type B & C Probes.<br />
Measures coating thickness over wood, concrete, plastics,<br />
composites etc. Will measure up to 3 individual layer thickness<br />
in a multi-layer system and features a graphic readout.<br />
Supplied with both B, 13 to 1000μm for wood, plastic and<br />
composites and C probes 50 to 3800μm for coatings on<br />
concrete, fibreglass etc. Accuracy is ±2um +3% of reading.<br />
58<br />
www.techrentals.com.au<br />
Non-Destructive Testing cont’d.<br />
Defelsko Positest Pull Off Adhesion Tester for Concrete & Metal<br />
DEF,POSITEST (4817) AU<br />
Measures the force required to pull a specified test diameter of coating away<br />
from its substrate using hydraulic pressure. Pressure is displayed in both MPa<br />
and PSI on a precision dial indicator and can be related to the strength of<br />
adhesion to the substrate. Suitable for coatings on both metal and concrete<br />
surfaces. Conforms with standards ASTM D4541 and ISO 4624.<br />
Krautkramer DMS Thickness Gauge<br />
KRA,DMS (4912) AU<br />
Complete with echo verification and logger. Includes high temperature<br />
probe and cable. Incorporates a wave form display for accurate assessment<br />
of material under test, measurement of thickness whilst ignoring external<br />
paint. Probe will operate to 200ºC without cooling, up to 540ºC with cooling.<br />
Measurement ranges 0.75mm to 250mm (for different ranges other probes<br />
are available). Resolution 0.01mm. Stores up to 80,000 readings or 1,200<br />
readings with full waveform information.<br />
Mitutoyo SJ-201 Surface Roughness<br />
Tester<br />
MIT,SJ201-NATA (4906) AU<br />
Comprises LCD display and a detachable<br />
detector/drive unit. Parameters measured in<br />
Ra, Rq, Ry, Rz, Rt, Rp, R3z, Rk, Rpk, Rvk,<br />
S, Sm, Pc, mr, Mr1, Mr2, A1, A2, Vo units. Ranges: 350, 100, 50μm & 10μm,<br />
resolution from 0.01 to 0.4μm. Tip radius 5mm. Data output. NiCd batteries.<br />
Olympus Ultrasonic Thickness<br />
Gauge<br />
OLY,38DL (4905) AU<br />
Operates with dual and single element transducers, has<br />
colour transflective VGA screen. Includes datalogging<br />
capability. Does echo echo measurements. Supplied<br />
with transducers to measure steel, cast, corroded<br />
steel, rubber, fibreglass & composites. Includes<br />
D7906-SM, M1036, M2008 M109-RM (inc Delay line<br />
M202-RM) transducers.<br />
Olympus 26mg Pocket Thickness Gauge<br />
PAN,26MG (4910) AU/MY<br />
Range 1 to 500mm, fast min mode. Resolution 0.01mm. Probe operates -20<br />
to 150ºC.<br />
PCWI 30kVDC Porosity Holiday Detector<br />
PCW,DC30 (4812) AU<br />
DC Porosity (Holiday) detector. Detects pinholes in coatings above 150um<br />
on metal substrates such as pipes and tanks. 0-30kV, 3.5 digit LCD display<br />
with battery indicator, display of voltage level. Alarm indicated on front panel,<br />
supplied with rechargeable battery, 10h charger, probe handle with neon<br />
and 2m length cable, 60mm connector for flat brushes, 7m earth cable with<br />
clamp, fan brush, 250mm flat brass wire brush, 450mm probe extension. Dry<br />
conditions.<br />
PCWI 40kV Pulse Porosity Holiday<br />
Detector<br />
PCW,P40-PULSE (4814) AU<br />
Pulse porosity (Holiday) detector. Detects<br />
pinholes in coatings and wrapping above<br />
150μm on metal substrates such as pipes and<br />
tanks. Can be used on dry or wet surfaces. 0<br />
to 40kV output, 4 digit LED display of voltage,<br />
alarm sensitivity setting between dry and<br />
wet. Supplied with rechargeable battery, 10h<br />
charger, red probe handle and 2m length of rubber coated cable, 60mm<br />
connector for flat brushes, 7m earth cable with clamp, fan brush, 250mm flat<br />
brass wire brush, 450mm probe extension and 80mm probe extension.
Olympus<br />
ultrasound | phased array | eddy current | eddy current array | remote visual inspection | X-ray fluorescence<br />
Olympus designs, manufactures, and globally markets a range of innovative nondestructive<br />
testing and remote visual inspection instruments developed with a commitment to technology,<br />
design, and user friendliness.<br />
These products are used for inspection and maintenance in industrial and research fields<br />
ranging from aerospace and energy to transportation and manufacturing. Olympus instruments<br />
contribute to product quality and add to the safety of infrastructure and facilities. Olympus has<br />
earned industry-wide reputations for providing cost-effective solutions and<br />
Solutions<br />
Corrosion Testing<br />
Weld Inspection<br />
Security<br />
Flaw Detection<br />
Thickness Measurements<br />
Automated Testing<br />
Image Capture<br />
Technologies<br />
Ultrasound<br />
Eddy Current<br />
Remote Visual Inspection<br />
X-Ray Fluorescence<br />
Tel.: 1300 132 992 Fax: (03) 9540 0924 info@olympus.com.au<br />
For worldwide representation visit www.olympus-ims.com<br />
excellent support and<br />
customer service.<br />
Ultrasound Phased Array<br />
Eddy Current Array<br />
High-Speed Video
PHYSICAL MEASUREMENT<br />
Non-Destructive Testing cont’d.<br />
Phynix Surfix FN Ferrous/Non Ferrous Coating Thickness Tester<br />
PHY,SURFIX FN (4803) AU<br />
Thickness tester with memory and statistics. Supplied with external probe,<br />
calibration standards and carry pouch. Measurement range 0 to 1,500μm or<br />
0 to 60mils (selectable), tolerance ±1μm +3% of reading, resolution 0.1μm.<br />
Display back light, 4 digit alphanumeric. Min measuring 5 x 5mm, min substrate<br />
thickness type F 0.5mm, type N 50μm. Calibration factory, zero, foil. Data<br />
memory 80 readings max. Interface infra-red down load data to PC utilising<br />
hyper terminal.<br />
Wylam Hill Paint Thickness Gauge<br />
WYL,PORTAPAINT MY<br />
Rugged, fully electronic coating thickness gauges use magnetic and<br />
eddy current principles to measure coating thickness on both ferrous and<br />
non-ferrous metals, accurately and quickly.<br />
Micrometers<br />
Position Transducers<br />
Mitutoyo 500-172 Digimatic Caliper<br />
MIT,500-172 (4965) AU<br />
Range 0 to 200mm (0 to 8”), resolution 0.01mm<br />
(0.0005”). Absolute measurement, LCD display.<br />
Temperature operating range 0 to 40ºC, storage<br />
temperature -10 to 60ºC. Button settings on/off,<br />
inch/mm. Origin, zero/ABS.<br />
Houston 1850-40 Position Transducers<br />
HOU,1850-40 (5311) AU<br />
Linearity 0.1% travel 40” (1m). Cable tension 280g. Max velocity 132cm/s.<br />
Output is a variable resistance arranged to provide both high level (V) and low<br />
level (mV) outputs when powered from an external source.<br />
MEL M5-200 4 to 20mA Optical Position<br />
Transducer<br />
MEL,M5-200 (5315) AU<br />
Optical distance measurement device 4 to 20mA output.<br />
Will measure distance from 240mm to 440mm<br />
with an accuracy of 0.06mm. Does not require a<br />
reflector on the surface of the device. Light spot<br />
diameter is 10mm. Light sensor is IP67. 4 to 20mA<br />
transmitter is IP40. Will operate from 10 to 30V. Relay outputs indicate error<br />
condition. 1ms, 2ms or 20ms adjustable reaction time. Light source infrared<br />
890nm invisible.<br />
Inclinometers<br />
Wyler Clinitronic 45 Inclinometer RS-232C<br />
WYL,CL45 (5326) AU/MY<br />
Resolution 0.01º. Accuracy better than 30arc sec. Display inclination in all<br />
common measurements. Includes RS232 interface for remote display of<br />
inclination and also logging. Settling time
www.techrentals.com.au<br />
Load Cells cont’d.<br />
Barlo STC-500 500lb/230kg Load Cell NATA Calibrated<br />
BAR,STC-500NATA (4403) AU<br />
Range 230kg compression and tension. Complete with conditioning<br />
electronics. Output 0-2V. Uses 1/2 UNF thread. NATA calibrated.<br />
Dillon ED2000 5,000kg Crane Scale<br />
DIL,ED2000-5K (4452) AU<br />
Complete with shackles. Range 5,000kg. Accuracy 0.1%.<br />
Resolution 1kg. i.e. 20kg uncertainty. Units of measure: kg, kt,<br />
mt, & lb. Proof load 200% of rated load. Displays gross and net<br />
force. Continuous measurement and peak hold.<br />
Weighing & Counting Scales<br />
Over 8kg<br />
See also Balances & Scales Below 8kg on page 77<br />
A&D Mercury FC-10K Counting Scales<br />
AND,FC-10K (4435) AU<br />
High resolution 10kg scales with sample counting facility. Display<br />
resolution 1g, internal resolution 0.02g. Sample size user selectable –<br />
normally 10 pieces. Max count size up to 999,999. AC & NiCd battery<br />
operation.<br />
A&D Mercury FG-150KB 150kg Scales<br />
AND,FG-150KB (4437) AU<br />
Capacity 150kg, 0.05 resolution. Includes RS232 port. National Standards<br />
Commission approved (NSC).<br />
bearcom<br />
telecom<br />
61<br />
PHYSICAL MEASUREMENT<br />
Weighing & Counting Scales<br />
Over 8kg<br />
A&D Mercury FS-15kg Weighing Scales<br />
AND,FS-15KA (4434) AU<br />
High resolution 15kg scales. Display resolution 1g. AC & NiCad battery<br />
operation.<br />
A&D HP-40KA 40kg Counting Scale<br />
AND,HP-40KA (4436) AU<br />
Capacity 40kg with 0.5g resolution. Can be used to determine battery<br />
weight change with charge, etc.<br />
Atlas TCS 60Kg Platform Scale<br />
ATL,TCS-60 (4441) AU<br />
60kG capacity. Rechargeable battery. 6 Digit display, 22mm<br />
height. Platform 450 x 600mm. Accuracy OIML III +/-50g.<br />
Mettler PB8001 8kg Counting Scales<br />
MET,PB8001 (4442) AU<br />
Capacity 8.1kg with 0.1g readability. Sample size selectable 5 to 100. Can<br />
do taring, percent and dynamic weighing. <strong>Power</strong>ed by battery eliminator.<br />
Mettler 15kg Weighing Scales<br />
MET,15KG MY<br />
Mettler 60kg Weighing Scales<br />
MET,60KG MY<br />
IRIDIUM - THE TRUE GLOBAL<br />
SATELLITE PHONE<br />
NEED TO BE REACHED WHILST WORKING IN REMOTE AREAS?<br />
Well you can be guaranteed to keep in contact<br />
regardless of the location when you take advantage<br />
of an Iridium satelite phone through TR.<br />
TR have been providing the mining sector with<br />
the safety and peace of mind a satellite phone on<br />
the Iridium network offers for over a decade.<br />
Call us today so we can tailor a solution for<br />
your business.<br />
TO PURCHASE CALL<br />
1300 550 014<br />
TO RENT CALL<br />
1800 222 327<br />
4 MONTH<br />
CASUAL<br />
PLANS<br />
AVAILABLE<br />
BR0093
PHYSICAL MEASUREMENT<br />
Vibration Analysis<br />
See also Noise & Sound <strong>Analysers</strong> on page 72-73<br />
B&K 8202 Vibration Impact Hammer<br />
BK,8202 (5010) AU<br />
For determining frequency response functions. Individually calibrated force<br />
transducer. Comes with 3 different tips and additional mass to enable pulse<br />
duration and frequency range to be determined.<br />
Blastronics UMX-SM-6 Explosion Logger<br />
BLA,UMX-SM-6 (5035) AU<br />
Triaxial geophones, microphone with logger used to determine explosion<br />
characteristics. Geophones auto-ranging to 110mm/s, resolution ±0.1mm/s.<br />
Microphone auto-ranging to 140dBL, resolution ±0.25dB. Sample rate 250,<br />
500Hz & 1kHz. Bandwidth geophones 4.5 to 500Hz. Microphone 2 to 500Hz.<br />
Includes software and download cable. Internal memory 4Mb. <strong>Power</strong> internal<br />
6VDC 2,600mAh Gel-cells, operating consumption 40mA, sleep mode 10mA.<br />
Continuous operation 65h, with 1w programmable timer schedule. Instrument<br />
has a display.<br />
Fluke 810 Vibration Tester<br />
FLU,810 (5050) AU<br />
Tests rotating machinery to determine the status of<br />
gearing wear etc. Used to: Troubleshoot equipment<br />
and understand cause of failure. Commission new<br />
equipment and ensure proper installation. Includes<br />
triaxial accelerometer and laser tacho. Store and<br />
reports FFT images to your PC. Very simple output<br />
that reports Pass and Fail on machinery condition.<br />
Linear LSPC-1 1G Accelerometer DC to LF<br />
LIN,LSPC-1 (5034) AU<br />
Designed for very low force levels ±1G measurement range. Operates down<br />
to DC in frequency. Output ±5V. Linearity 0.05%, resolution 0.001%. Shock<br />
Survivability 100g. Natural Frequency 100Hz.<br />
Madgetech Ultrashock-EB Transportation Logger<br />
MAD,ULTRASHOCK-EB (5025) AU<br />
Ultrashock-EB transportation ambient temperature, humidity, barometric<br />
pressure and 3 axis shock acceleration logger. Ranges: -40 to 180ºC,<br />
0-95%RH, 0 to 30PSIA (0-200kPa , -50g to +50g. Memory 23,831 readings<br />
per channel. Logging interval from 1 reading per 2s to 1 reading per 12h.<br />
Sampling rate 2ms. Includes RS232 interface and setting up, downloading,<br />
graphing software.<br />
PCB Low G Accelerometer DC to 300Hz<br />
PCB,300A20 (5014) AU<br />
Single axis accelerometer includes charge amplifier. Range ±20g, frequency<br />
(±5%) DC to 300Hz, (±10%) to 500Hz. Shock limit ±5kg. Operating temperature<br />
-40 to 85ºC. Weight 15g. Voltage sensitivity 100mV/g.<br />
Profound Vibra Ground<br />
Vibration Logger<br />
PRO,VIBRA (5023) AU<br />
Designed for long term ground vibration logging.<br />
Includes a Geophone and remote alarm with<br />
flashing light. Velocity Range 0 to 100mm/s. 4 weeks<br />
operation on 3 x D cell batteries. USB interface.<br />
Download possible while measuring. Full Windows<br />
analysis software included. IP65 case. Meets standards for ‘Vibration in<br />
buildings’ - Effects on structures’ and ‘Effects on persons in buildings’, such as<br />
the DIN 4150 – part 2 and 3, DIN 45669 and the SBR 2002.<br />
Rion CP-10 RS-232 Printer VA10 NL05 NL14<br />
RIO,CP-10 MY<br />
Printer for RIO,VA-10. Operates from optional NiCd battery pack.<br />
62<br />
Vibration Analysis cont’d.<br />
Rion VA-10 Vibration Analyser<br />
RIO,VA-10 MY<br />
Measures acceleration, velocity and displacement. Stores 500 readings.<br />
LCD display with waveform, spectrum and data readout. Auto measurement<br />
function. Includes printer interface.<br />
Rion VA-11 Vibration Analyser<br />
RIO,VA-11 (5042) AU/MY<br />
Includes 2 pickup types hand held (PV55) and magnetic type (PV57).<br />
Measures acceleration, velocity and displacement. Displays RMS, peak and<br />
crest factor. Uses FFT to display power and vibration spectrum. Incorporates<br />
<br />
PV57 1Hz to 5kHz, PV55 3Hz to 20kHz (velocity 3kHz, displacement 500Hz).<br />
Acceleration 0.02 to 316mm/s 2 rms. Velocity 0.1 to 1,000mm/s rms.<br />
<br />
pass 1kHz, 5kHz and 20 kHz. Stores 500 measurements.<br />
Svantek SV100 Whole Body Vibration Analysis<br />
SVA,SV100 (5005) AU<br />
Human vibration meter and analyser. Completely self-<br />
contained, integrated unit. Does whole body vibration<br />
dose (exposure) measurements, octave measurements,<br />
time domain record measurements & motion sickness<br />
measurements. Includes external alarm, car power<br />
adapter or will run from battery pack for >16hrs. USB<br />
interface for programming and download.<br />
Svantek 912A Sound Vibration Analyser<br />
SVA,912A (5001) AU<br />
Type 1 sound level meter including a single axis accelerometer. Provides<br />
standard sound measurements and vibration measurements including 1/1 octave,<br />
1/3 octave and full spectrum. Will store 1Mb of spectrum analysis information<br />
for waterfall plots etc. PC interface software included. Can make part<br />
body vibration measurements. Includes SV06A 4 input module and a triaxial<br />
accelerometer.<br />
Texcel ATM Explosion and Ground<br />
Vibration Logger<br />
TEX,ATM (5036) AU<br />
Triaxial geophone and overpressure (airblast) microphone<br />
with logger used to determine explosion and<br />
ground vibration characteristics. Geophone range to<br />
±55.6mm/s, resolution 0.014mm/s up to 6.95mm/s,<br />
0.109mm/s up to 55.9mm/s. Microphone range 80-dBL<br />
to 140dBL, resolution 0.049Pa up to 122dBL (25Pa), 0.40Pa up to 140dBL<br />
(201Pa). Sample rate 20, 50, 100, 200, 500Hz & 1kHz. Bandwidth: geophone<br />
4.5Hz to 500Hz, microphone 2Hz to 500Hz. Includes software and download<br />
cable. Internal memory 2Mb. <strong>Power</strong> internal 12VDC 7Ah batteries. Continuous<br />
operation 240h. Supplied with 90 to 260V 50/60Hz charger, recharge time 8h<br />
approx. 16 character LCD display, weatherproof enclosure, rated IP65.<br />
Operating temperature 0 to 70ºC, display 0 to 50ºC. Supplied with alarm light,<br />
reset button and 2 x 15m cable. External DC power supply cable also supplied.<br />
Speed Measurement<br />
www.techrentals.com.au<br />
Phantom 53550 Radar Gun kph with Case<br />
and Tuning Fork<br />
PHA,53550 (5324) AU<br />
Doppler K band (24.150GHz) stationary radar<br />
gun. Pull the trigger and the speed display<br />
appears instantly. Invisible to all radar detectors.<br />
<strong>Power</strong> requirements 10.5 to 16.5VDC, 13.5VDC nominal, 1.5A max, external<br />
source, connection via 1.8m coiled power cord with fused lighter plug.<br />
Operating environment -20 to 60ºC, 90%RH @ 37ºC (non-condensing).<br />
<br />
Speed range 17 to 332kph.
Transport – Oil rigs – Communication – Manufacturing – Construction – Mining<br />
HAVE YOU EVER EXPERIENCED TIMES WHEN MERELY IDENTIFYING A<br />
PROBLEM BECAME AN ISSUE, MUCH LESS FINDING THE SOLUTION?<br />
These situations can be extremely frustrating and time-consuming. This is when the combination of both the depth<br />
of experience and diverse talent range of our TechRentals team come to the forefront.<br />
Take a look at a few of our recent pro ects A transport condition monitoring system was engineered to measure the<br />
lateral and vertical acceleration experienced by railway vehicles. Problem, hot spots on the track were identified<br />
with a GPS system which was customised by one of our team members. The mapped output clearly displayed the<br />
exact location of problem sections along the track. This system can be adapted to any vehicle application.<br />
TechRentals recently installed a remote flow monitoring system on an offshore oil rig with internet communications<br />
connected with the mainland.<br />
Our team also provided solutions for monitoring the concrete curing process which delivers matched temperature<br />
control of the concrete pour samples. The customised remote logger out in the field communicates temperatures<br />
back to the sample bath in the construction office.<br />
Further, we have implemented a program to facilitate the Drive Test of mobile communications for the upgrade of<br />
the 3G smart phone systems to measure quality of service, including data and voice.<br />
Therefore, no matter what your application or measurement requirement, let our expert Technology team provide a<br />
customised solution for your pro ect.<br />
We do much more than rent equipment. TechRentals - Your Technology Solutions Partner<br />
Two amazing products. One trusted name.<br />
Fluke, mastering your<br />
preventative maintenance needs.<br />
SLIGHT MODERATE SERIOUS EXTREME<br />
The only thing that precedes Fluke’s highest standards of quality is our<br />
reputation for making the finest measurement tools in the world.<br />
Fluke P3 Thermal Imagers and 810 Vibration Tester are no exception.<br />
63<br />
P 3<br />
Proven<br />
Practical<br />
Performance
CONSTRUCTION, BUILDING SERVICES & SURVEY<br />
Air Conditioning & Air Flow<br />
Air Conditioner Valve Balancing<br />
Concrete Testing Equipment<br />
Underground Services Location<br />
Utility Leak Detection<br />
Ground Penetrating Radar<br />
Pipeline & Cavity Inspection<br />
Material Moisture Meters<br />
Distance Measurement & Surveying<br />
Air Conditioning & Air Flow<br />
Airflow AV2 100mmØ Anemometer with Volume Display<br />
AIR,AV2 (5836) AU<br />
Vane anemometer with 900mm telescopic probe extension. Velocity<br />
measurement range 0.25 to 30m/s. Averaging mode available. Volume display<br />
based on duct or other area. Head operating range -10 to 70°C (lower limit of<br />
-30°C for short periods). Output 0 to 1V.<br />
Airflow AV2 100mmØ Anemometer NATA Certification<br />
AIR,AV2-NATA (5837) AU<br />
Specification as above but with NATA certification.<br />
Airflow 36 Pitot Tube<br />
AIR,PITOT-36 (5816) AU<br />
Pitot tube (36”) for use with manometers and micro manometers.<br />
Alnor EBT-721-A3 Electronic Micromanometer<br />
ALN,EBT-721-A3 MY<br />
Detachable multi-purpose digital manometer that can be used with the<br />
following test and balance tools, such as pitot, air foil, temperature, relative<br />
humidity probes or a 16-point velocity matrix. Differential pressure: ±15 in.<br />
H 2 O, (3735 Pa) 150 in. H 2 O maximum safe operating pressure. Absolute<br />
pressure: 15 to 40 in. Hg (356 to 1016 Hg). Velocity: 25 to 8,000 ft/min (0.125<br />
to 40 m/s) pitot probes; 25 to 5,000 ft/min (0.125 to 25 m/s) air flow probe;<br />
25 to 2,500 ft/min (0.125 to 12.5 m/s) velocity matrix. Volume: 25 to 2,500<br />
ft 3 /m (42 to 4250 m 3 /h) capture hood. RH: 0 to 95% RH (optional probe),<br />
Temperature: -40 to 250°F (-40 to 121°C) probe dependant. Standard comes<br />
with 2ft x 2 ft, upon request additional hood of 2ft x 4 ft and 1ft x 4ft hood would<br />
be provided.<br />
Alnor EBT721-Z Balometer Electronic Balancing Tool with detachable<br />
Multi-purpose Digital Manometer<br />
ALN,EBT-721-Z3 MY<br />
The unit comes with the following test and balance tools, such as pitot, air foil,<br />
temperature, relative humidity probes or a 16-point velocity matrix. Differential<br />
pressure ±15in H2O, (3735Pa) 150in H 2 O maximum safe operating pressure.<br />
Absolute pressure: 15 to 40in Hg (356 to 1016Hg). Velocity: 25 to 8,000ft/min<br />
(0.125 to 40m/s) pitot probes; 25 to 5,000ft/min (0.125 to 25m/s) air flow probe;<br />
25 to 2,500ft/min (0.125 to 12.5m/s) velocity matrix. Volume: 25 to 2,500ft 3 /m<br />
(42 to 4250m 3 /h) capture hood.<br />
CSS Portable Smoke Generating Machine<br />
CSS,COLT4 (5890) AU<br />
Portable smoke generator with variable smoke emission<br />
rate. Suitable for air flow visualisation, HVAC ductwork<br />
leak-testing, fire training and general work. Pump-free<br />
operation with smoke fluid supplied from consumable aerosol cans. Manual or<br />
continuous operation and off-power facility. Maximum output 31 cubic meters/<br />
min at 1.5m visibility. Operation for 18min from one can at maximum capacity.<br />
64<br />
www.techrentals.com.au<br />
Air Conditioning & Air Flow cont’d.<br />
Druck DP1705 Manometer 0 to 20kPa<br />
DRU,DPI705 (5808) AU<br />
Handheld digital manometer range 0 to 20kPa, accuracy 0.2%. Displays all<br />
common engineering units.<br />
Druck DPI705-IS Manometer 0 to 20kPa<br />
Intrinsically Safe<br />
DRU,DPI705-IS (5809) AU<br />
Hand held Manometer 0 to 20kPa range. Accuracy 0.2%.<br />
Displays all common engineering units. Intrinsically Safe.<br />
Kurz 2443 Air Velocity Meter<br />
KUR,2443-24 (6172) AU<br />
Portable air velocity meter and flow-computer. Velocity<br />
range 0 to 12,000sf/min (60m/s) at pressures to approx<br />
10bar (probe rated to 20Bar). Temperature range -40<br />
to 200°C with compensation. User selected English or<br />
metric units for velocity or mass-flow. Thermal sensor<br />
probe 9.5mmØ & 330mm long with sensor-shield, with<br />
compression fitting and nylon ferrules for probe removal<br />
or position adjustment in tapped pipe. Suitable for use<br />
in ducts or pipes, min pipe 50Ømm. Calibrated for air, and suitable for use<br />
with other non-hazardous gases. Recording of up to 1,500 data sets with<br />
time and date. Two analogue 4 to 20mA outputs, and RS232C serial port for<br />
configuration upload and data download. Rechargeable NiMH batteries.<br />
Sensocon Air Flow Capture Hood<br />
SEN,VF01B (5828) AU<br />
Large LCD display. Includes 610x610mm,<br />
610x1220mmm & 305x1220mm flow hoods.<br />
Measurement range 85~3400m 3 /hr. Velocity range<br />
0.2~7.6m/sec. Accuracy Supply ±3% ±12m 3 /hr Exhaust<br />
±4% ±12m 3 /hr 100 reading logging memory. 10+<br />
battery life/.<br />
Shortridge ADM-860 Electronic Manometer<br />
SHO,ADM-860 (5812) AU<br />
Electronic micromanometer for air balance and similar applications. Measures<br />
differential pressure, air velocity and temperature using accessories included.<br />
Differential pressure range 0.0025 to 1500 mm water gauge. Air velocity range<br />
7.5 to 3,000 m/min (750 m/min with velgrid). 100 point memory with sum and<br />
average. Accessories include pitot tube and a 16 point velgrid for face velocity<br />
work including exhaust hoods, clean room outlets, and large filters or coils.<br />
Shortridge CFM88-3 Electronic Balometer<br />
SHO,CFM88-3 (5830) AU<br />
Measures supply and exhaust flow in cfm and l/s. Ranges 25 to 2500cfm<br />
supply and 25 to 1500cfm exhaust. Compensated for air density and back<br />
pressure. Hood sizes 600 x 600mm, 600 x 1,200mm & 300 x 1,200mm.<br />
Testo 445 Vane Anemometer with 16mm vane<br />
TES,445 (5842) AU<br />
Micro-vane probe. Simultaneous digital display of air<br />
velocity and temperature, with continuous-update,<br />
max, min & mean functions. Volume-flow option<br />
with entry of duct dimensions. Telescope mounted<br />
metal probe, vane 16mmØ. Operating range 0.4<br />
to 60m/s, accuracy ±0.2 m/s, ±1%mv up to 40m/s.<br />
Temperature range -30 to 140ºC for short-term<br />
measurements. Selectable site-locations, and 3,000<br />
point internal memory for manual saving or automatic<br />
data logging. Battery powered.
www.techrentals.com.au CONSTRUCTION, BUILDING SERVICES & SURVEY<br />
Air Conditioning & Air Flow cont’d.<br />
TSI 8324 VelociCalc 100mm<br />
Vane Anemometer<br />
with Volume Display<br />
TSI,8324 (5839) AU<br />
Vane anemometer with 100mm head, supplied<br />
with handle and 900 mm articulated telescopic<br />
extension. Velocity measurement range 0.25<br />
to 30m/s ±1%; temperature measurement<br />
range 0 to 80ºC ±0.5 ºC. Volume display range 0 to 4.36 x 106m 3 /h with input<br />
for circular or rectangular duct dimensions. Variable time-constant; sample<br />
statistics average, max and min; and “sweep” mode for extended continuous<br />
sampling. Internal memory for single point measurements or time-based data<br />
logging, for up to 2849 samples and 1,000 test IDs, with serial interface, cable<br />
and software for data download. Direct data acquisition [polling] from PC<br />
terminal modes. Battery powered with auto-power-off, and optional AC adaptor.<br />
TSI 8345 Hot Wire Anemometer<br />
TSI,8345 (5844) AU<br />
Thermal anemometer range 0.15 to<br />
30m/s; accuracy ±3%; volumetric flow display;<br />
averaging capability up to 255 readings. Probe<br />
operating temperature range -17.8 to 93.3°C.<br />
Probe 98mm long x 6mmØ at tip. Digital display.<br />
RS232C printer interface. Battery or mains<br />
operation.<br />
TSI 8373 Balometer With Logging<br />
TSI,8373 (5826) AU/MY<br />
Flow range 15 to 1,000l/s (54 to 3,600m 3 /h); accuracy ±5% [to ±2.4l/s].<br />
Operating temperature range 0 to 60°C. Includes 5 hood kit & hard case.<br />
Hoods provided 610 x 610mm (standard), 610 x 1,220mm, 305 x 1,220mm,<br />
305 x 1,525mm & 915 x 915mm.<br />
TSI 8375 Accubalance Modular Air Balancing Tool<br />
TSI,8375 (5827) AU<br />
Balometer with detachable micromanometer (TSI 8710) for air balancing<br />
applications. With 610 x 610mm air capture hood for measurements in the<br />
range 42 to 4250m 3 /h with automatic compensation for barometric pressure<br />
and air temperature, 45cm pitot probe [range 0.13 to 41m/s], 16-point velocity<br />
matrix probe [0.13-13m/s] and static pressure probes [differential pressure<br />
range ±3735Pa with safe limit 37kPa, absolute pressure range 47 to 135kPa.<br />
Accuracy typically 2% for pressure, 3% for flow. Large, multi-line backlit LCD<br />
display for single or statistical readings with min, max and average of up to<br />
1,000 values of each measured parameter. Manual result storage or automatic<br />
data logging up to 1,000 time/date stamped readings. RS232 port for data<br />
transfer to PC or serial printer, with cable and “LogDat” download software.<br />
Rechargeable with approx 12h operation, or AC adaptor.<br />
TSI 8386A VelociCalc Air Conditioning Efficiency Meter<br />
TSI,8386A (5848) AU<br />
Portable efficiency measurement system for HVAC and related<br />
work, with hot wire anemometer, static and differential pressure, temperature<br />
and humidity measurement with heat flow efficiency calculation. Velocity (hot<br />
wire) 0 to 50m/s, accuracy ±3%. Temperature -10 to 60°C, accuracy ±0.3. Wet<br />
bulb temperature 5 to 60°C. Relative humidity 0 to 95%RH, accuracy ±3%.<br />
Dewpoint -15 to 49°C. Static/differential pressure -1,245 to 3,735Pa, accuracy<br />
±1%. Probe length 100cm, tip diameter 7mm, base diameter 10mm. Includes<br />
data logging and printing. Battery operated.<br />
TSI 8705 DP-CALC Differential Micro-Manometer<br />
TSI,8705 (5815) AU<br />
Differential micro-manometer measuring differential<br />
pressure, velocity, average, volumetric flow, maximum<br />
and minimum. With static pressure calculations, density<br />
correction and K factor. Pressure range -1245 to 3735Pa.<br />
Velocity range 1.27 to 78.5m/s. Supplied with 200 to 980mm<br />
telescopic pitot tube. Datalogging (1,000 point) with RS232C<br />
interface and software. Battery powered.<br />
65<br />
Air Conditioning & Air Flow cont’d.<br />
TSI 8710 DP-CALC Differential<br />
Micro-Manometer<br />
TSI,8710 (5813) AU<br />
Micro-manometer for static or differential<br />
pressure, velocity, volumetric flow, atmospheric<br />
pressure and temperature. With statistical<br />
analysis, density correction, K factor and<br />
automatic actual/standard flow calculation. Differential pressure range<br />
±3735Pa. Velocity display to 41m/s (range depends on probe). Supplied with<br />
static tip, pitot tube, velocity matrix and temperature probe. Datalogging (1,000<br />
point) with RS232C interface and software. Rechargeable cells or AC adaptor.<br />
TSI 9535 Anemometer with Logging Capability<br />
TSI,9535 (5845) AU<br />
Includes data captured download software and USB cable. Logs<br />
velocity and temperature. Will calculate flow rates. 0 to 30m/s Accuracy 3%<br />
of reading or ±015m/sec whichever is greater. Temperature range -18 to 93°C<br />
±0.3°C. Runs 4 x AA batteries.<br />
TSI 9555 Multi-Function Ventilation Meter<br />
TSI,9555 MY<br />
Portable, hand held, multi-function ventilation meter. Comes with differential<br />
pressure and 966 articulate probe which measures air velocity, temperature<br />
and humidity. Calculations include air flow, heat flow, turbulence, wet bulb and<br />
dew point temperature. Velocity measurement: Range: 0 to 9,999 ft/min (0<br />
to 50 m/s) , Accuracy: ±3% of reading or ±3 ft/min (±0.015 m/s), Resolution:<br />
1 ft/min (0.01 m/s). Temperature measurement: Range: 14 to 140°F (-10<br />
to 60°C), Accuracy: ±0.5°F (±0.3°C), Resolution: 0.1°F (0.1°C). Humidity<br />
measurement: Range: 0 to 95% RH, Accuracy: ±3% RH, Resolution: 0.1%<br />
RH.<br />
Vaisala WAA151 Wind Speed/Direction Transducer<br />
VAI,WAA151 (5886) AU<br />
Range 0.4 to 75m/s. Current output with selectable ranges including 4 to<br />
20mA & 0 to 20mA. Requires indicator module such as DE,DT600 datalogger<br />
for indication of wind speed and direction.<br />
Air Conditioner Valve Balancing<br />
Tour & Anderson CBI Balancing Meter<br />
TA,CBI (5800) AU<br />
Digital pressure balancing instrument<br />
with LCD display. For cooling water valve<br />
balancing in air conditioning plants and<br />
similar applications. Firmware revision<br />
3A. Includes facility for entry of Kv<br />
value to allow balancing of all hydronic<br />
valve types. Differential pressure range<br />
-0.5 to 20.5m water gauge at a total pressure of less than 200m. Resolution<br />
0.001m. Flow resolution 0.001l/s. Battery operated.<br />
Concrete Testing Equipment<br />
See also Endoscopes, Borescopes & Visual Inspection on page 46-47<br />
See also Ground Penetrating Radars on page 67<br />
See also Pipeline & Cavity Inspection on page 67-68<br />
Elcometer 331-B Basic Cover Meter<br />
ELC,331-B (4923) AU<br />
Displays the depth and orientation of the reo bars.<br />
Deep search head supplied. 40mm diameter bar<br />
depth 35 to 180mm depth, 8mm diameter bar<br />
depth 25 to 160mm depth. Rechargeable battery<br />
allows 32h of continuous operation (20h with backlight).
CONSTRUCTION, BUILDING SERVICES & SURVEY<br />
Concrete Testing Equipment cont’d.<br />
Elcometer 331-SH Cover Meter with Half Cell Measurement<br />
ELC,331-SH (4919) AU<br />
Zero calibrate the unit. Select the bar size. The instrument then displays the<br />
depth and orientation of the reo bars. Standard search head. 40mm diameter<br />
bar depth 15 to 95mm. 8mm diameter bard depth 8 to 70mm. Rechargeable<br />
battery allows 32h of continuous operation (20h with backlight). Autosizing<br />
of bars or orthogonal measuring of bar sizes. Internal storage of readings<br />
of depth of cover in batches which can be downloaded to PC with supplied<br />
software. XP and Vista supported.<br />
Hilti Ferroscan Concrete Reo Scanner<br />
HIL,FERROSCAN (4927) AU<br />
Reinforced concrete imaging system.<br />
Displays depth of concrete coverage,<br />
location of reinforcement rods and<br />
anchor setting points. Fast, simple<br />
operation. Depth mode allows reinforcement<br />
rods at different depths to be viewed. Printer interface and PC interface<br />
and software allow images to be printed and/or stored for further use. Depth<br />
coverage up to 180mm. Reinforcement rod diameter measurement range 6 to<br />
36mm. Area covered in a single measurement run 600 x 600mm; 42 image<br />
memory allows total 15m 2 coverage without downloading.<br />
Hilti PS20 Rebar, Copper Pipe & Electrical<br />
Cable Locator<br />
HIL,PS20 (4920) AU<br />
Localise and position of reinforcement, (rebars) copper,<br />
aluminium pipes and unshielded live electric cables. Depth<br />
range for detection of rebars 0 to 100mm, for copper &<br />
aluminium pipes 60mm, rebar diameter 8 to 36mm, depth<br />
detection accuracy 10 to 30mm ±2mm, above 30-60mm<br />
± 2mm ±10% depth, above 60 to 80mm ±5mm ±10% depth, based on 12mm<br />
rebars. Detection of copper & aluminium pipes based on 10 to 30mmØ, only<br />
detection with depth of 0 to 60mm, no depth reading, same for live electric<br />
cables, cannot detect live cables in metal conduit or shielded cables.<br />
Hilti PS200 Ferroscan System<br />
HIL,PS200 FERROSCAN (4921) AU<br />
Portable, quick and easy to use for detecting rebar and other<br />
ferrous objects in concrete structures. Provides accurate on-site rebar<br />
location, depth and rebar diameter. Scans can be evaluated on the monitor<br />
or transferred to a PC or laptop for further evaluation and report generation.<br />
Portable wireless operation, easy Integrated LCD display makes setting up<br />
the scan easy while providing information over the scan process. Fast data<br />
download via infra-red beam from scanner to monitor. Convenient<br />
Scanner stores up to 9 image scans and 30m of Quickscans and PS 200M<br />
monitor allows you to perform on-site evaluation of rebar depth, diameter<br />
and location.<br />
Handy Search NJJ-95B<br />
Reinforced Concrete Radar<br />
JRC,NJJ-95B (4922) AU<br />
Ground penetrating radar (GPR) technology<br />
applied to the location of reinforcement in<br />
concrete. Unit will search to a depth of 30cm.<br />
Displays scanned images, very easy to<br />
interpret. Scan information can be saved to a memory card for transfer<br />
to a PC. A 3D image of the slab can be generated using PC software. Can<br />
be used to detect voids in concrete and the concrete depth is easy to<br />
determine from the image. The location of non-metallic objects can also<br />
be determined.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.<br />
66<br />
Concrete Testing Equipment cont’d.<br />
Olsen FTG Concrete Thickness Gauge<br />
OLS,FTG (4929) AU<br />
Concrete thickness gauge utilising the impact echo test method. Can<br />
measure concrete thickness in two ranges: 6 to 60cm and up to 1.8m.<br />
This concrete thickness gauge is a battery operated handheld system for<br />
measuring the flaws and thickness of concrete slabs, pavements, walls<br />
and other plate-like structures from one side. Up to 300 readings can be<br />
stored in the field before the memory is full. RS232 interface and transfer<br />
software supplied.<br />
Proceq 2000-ND Digi Schmidt Test<br />
Hammer<br />
PRO,2000-ND (4930) AU<br />
Concrete hardness tester (Schmidt<br />
hammer). Supplied complete with inbuilt<br />
graphical LCD for setting up and graphical<br />
display of results, up to 500 results can<br />
be stored. RS232 interface and software<br />
supplied for down loading. Impact energy 2.207Nm. Engineering units of<br />
results in N/mm 2 , MPa, psi, kg/cm 2 . For concrete thickness greater than<br />
100mm.<br />
Proceq Profoscope Rebar Locator & Cover Meter<br />
PRO,PROFOSCOPE (4926) AU<br />
Rebar locator and covermeter. Short range measurements<br />
to 95mm ±3mm accuracy. Long range 185cm accuracy<br />
± 4mm. The unit will determine the position of the rebars, the<br />
mid point between rebars, Concrete cover, estimation of bar<br />
diameter & the orientation of the rebar. <strong>Power</strong>ed by 2 x AA<br />
batteries. Battery life 15h with backlight 55h without.<br />
Proceq SilverSchmidt UN Concrete<br />
Test Hammer<br />
PRO,SIL-UN (4928) AU<br />
Requires no corrections for angle of test,<br />
simple one button operation, datalogging<br />
capability with USB download with detailed reporting capability. Impact<br />
energy 2.207Nm. Compressive strength range 10 to 170MPa. Battery Life<br />
>1,000 Impacts before recharging is required.<br />
Protimeter Moisture Measurement System<br />
PRO,MMS-PLUS (4955) AU<br />
Moisture meter for detection of moisture in non conductive solid materials<br />
such as wood and masonry. Two measurement modes, search for<br />
qualitative measurements and measure mode for precise and localised<br />
moisture content. Supplied with pin type probes, deep wall probes,<br />
hygrometer probe and extension cord for RH, ambient temperature or<br />
dew point temperature. Hygrostick probe supplied for surface temperature<br />
measurement. Logging software and RS232 computer interface supplied.<br />
See also Material Moisture Meters on page 68<br />
Underground Services Location<br />
See also Prospecting Metal Detectors on page 78<br />
www.techrentals.com.au<br />
Cable Ezidig Detection Excavator<br />
Mounted Cable Locator<br />
CAB,EZIDIG (3690) AU<br />
Excavator mounted service locator. This<br />
cable avoidance tool is designed to give real<br />
time warnings to an excavator operator of<br />
buried magnetic services. The kit includes<br />
the sensor unit which is mounted on the<br />
excavator arm, the In-Cab display and a<br />
signal generator.
www.techrentals.com.au CONSTRUCTION, BUILDING SERVICES & SURVEY<br />
Underground Services Location<br />
cont’d.<br />
CScope CATXDSGV-KIT Cable and Pipe Locator<br />
CSC,CATXDSGV-KIT (3664) AU<br />
Cable location tool. Includes 33kHz generator with<br />
touch button controls and LCD, XD receiver/ locator with<br />
33kHz, power or radio modes. Direct connection cable,<br />
stake and 75mm tong set. The transmitter can operate<br />
with direct connection, tongs or induction. The instrument<br />
will also determine cable depth, range 0.2m to 3m.<br />
It will operate with the Radiodetection 33kHz sondes.<br />
CScope CATXDSGA-KIT<br />
Cable and Pipe Locator<br />
CSC,CATXDSGA-KIT MY<br />
Industry standard Locator to use to determine<br />
the exact location of buried pipes and cables<br />
immediately prior to any form of excavation work<br />
taking place. 3 position function select switch:<br />
<strong>Power</strong> mode for detecting live imbalanced cables. (Depth range 3m). Radio<br />
mode for detecting re-radiated radio signals. (Depth range 2m). Generator<br />
mode for detecting conductors carrying the signal generated by the C.Scope<br />
signal generator. (Depth range 3m). Frequency: power mode 50-400Hz, radio<br />
mode 15-20kHz, generator mode 33kHz.<br />
Radiodetection Flexisonde Pipe Tracer<br />
RAD,FLEXISONDE (3668) AU<br />
Sonde for use with RD400PXL. Flexible rod on reel 50m long complete<br />
with 2 sondes. Small sonde transmitter is suitable for insertion into plastic<br />
pipes of 25mmØ & 150mm min bend radius. Can be detected at depths up to<br />
1.5m. Larger sonde can be detected at 5m depth and is suitable for insertion<br />
into plastic pipes of 80mmØ & 210mm min bend radius. Sondes are battery<br />
operated.<br />
Radiodetection A Frame for RAD,RD4000 Type 7 Kit<br />
RAD,AFRAME FORRD4000 (3678) AU<br />
A-Frame accessory for RAD,RD4000Type7KIT. For sheath to ground type<br />
ault finding.<br />
Radiodetection RD4000 Type 7 Cable Location Kit<br />
RAD,RD4000TYPE7KIT (3676) AU<br />
Includes transmitter and locator. Receiver has 640Hz,<br />
8, 33 & 82kHz, 2 power and radio modes. 3 locating<br />
modes. Modes, 2 peak, 1 null, location arrows,<br />
simultaneous digital depth and current readout.<br />
Transmitter T10 version, FF, 640Hz, 8, 33 & 82kHz<br />
transmission freq. LCD display for freq, power, battery<br />
and connection readout, multimeter function, cable<br />
fault find function, 10W output, high efficiency induction mode. Signal clamp<br />
100mmØ. Connection leads and carry bag.<br />
Radiodetection RD400PXL Pipe and Cable Locator<br />
RAD,RD400PXL (3672) AU<br />
Precision pipe & cable locator with microprocessor based controls and digital<br />
display. Can also measure current in buried lines. Includes transmitter and<br />
locator, peak and null location by audio and meter, very useful in congested<br />
areas. Has power /radio/8kHz/33kHz modes, can read depth to 3m. Includes<br />
direct connect lead and signal clamp (tong) (10cm). Works with optional<br />
sondes to trace sewers and plastic pipes.<br />
Vivax VLOCPRO Pipe and Cable<br />
Location System<br />
VIV,VLOCPRO (3676) AU<br />
Pipe and Cable locator with intuitive menu<br />
system, colour display, peak, null, left/right<br />
and orientation (compass) response to support your preference. Configured<br />
with 6 location frequencies, power and radio modes. 10 watt transmitter can<br />
apply the location signal by connection, induction and signal clamp. Depth<br />
detection up to 6 to 9 meters in broad-peak mode.<br />
67<br />
Utility Leak Detection<br />
Gutermann Aquascope 3 Leak Locator<br />
GUT,AQUASCOPE3 (3683) AU<br />
Listens for the sound of a leak. Specifically designed digital signal processing<br />
designed to remove electrical noise and provide the operator with only the sound<br />
of the leak. Includes both ground microphones and hand probe microphones. The<br />
display indicates the level of the noise from the leak, that way you can determine<br />
when you are nearest to the leak i.e. when the level is at its highest.<br />
ICC LD400 Ultrasound Leak and Emission Detector<br />
ICC,LD400 (3688) AU<br />
Used to detect water and gas leaks, from ultrasonic emission. Also used for<br />
mechanical noise location. Supplied complete with an ultrasonic transmitter to<br />
enable leaks within containers to be detected, e.g. vehicle bodies, fuel tanks. Aural<br />
and visual indication. Battery operated.<br />
ICC LD408 Noise Leak Detector<br />
ICC,LD408 MY<br />
Used to detect water & gas leaks, etc. from ultrasonic emission. Also may<br />
be used for mechanical noise location. Supplied complete with an ultrasonic<br />
transmitter to enable leaks within containers to be detected, e.g. vehicle<br />
bodies, fuel tanks. Aural & visual indication. Battery operated.<br />
Ultra Probe UP100KT Ultrasonic Leakage<br />
Detector<br />
ULT,UP100KT (3685) AU<br />
Hand held pistol type with stainless steel sensor<br />
enclosure. Frequency response 20 to 100kHz,<br />
(centred at 28 to 42kHz), 10 segment LED<br />
bargraph (red). Sensitivity 8 precision attenuation. Response time 300ms,<br />
operating temperature range 0 to 500°C. Kit includes contact stethoscope<br />
module with different wave guide extension rods for direct for use on pipes,<br />
bearing housings, steam traps, etc. Rubber focusing probes, head set, warble<br />
tone generator for determining leaks in seals of empty containers, etc.<br />
Ground Penetrating Radar<br />
See also Concrete Testing Equipment on page 65-66<br />
USRadar Ground Penetrating Radar System<br />
USR,SEEK-SPR (3601) AU<br />
Designed to locate buried objects. Typically used<br />
for the location of cables and pipe, detection of pipe<br />
and the detection of underground storage tanks.<br />
For targets as small as 5cm diameter and up to 4m<br />
depth.<br />
Pipeline & Cavity Inspection<br />
See also Endoscopes Borescopes Visual Inspection on page 46-47<br />
Aqua Snakeeye Video<br />
Inspection System<br />
AQU,SNAKEEYE3 (5121) AU<br />
Handheld video system. For<br />
remote inspection work. It is very<br />
light and compact. Includes a 12.7cm TFT-LCD display and 3cm diameter<br />
camera including illumination. Various adapters are supplied for mounting<br />
the camera to: a) your hand, b) a 45.7cm arm with 90 degree articulation or,<br />
c) a 30m extension cable, d) an arm which extends from 1.6 to 3.6m. Includes<br />
memory card and will save images to card.
CONSTRUCTION, BUILDING SERVICES & SURVEY<br />
Pipeline & Cavity Inspection cont’d.<br />
Archos AV 500 Mobile Digital Video Recorder - 100 GB<br />
ARC,AV500 (5150) AU<br />
Unique mobile digital video recorder offering direct TV recording and the best<br />
of video, photo and music on the go on a 4” colour screen, 100 GB hard drive.<br />
Easy setup pod for TV recording & video playback , control your VCR, cable<br />
or satellite receiver. Record directly to TV or make scheduled recordings,<br />
photo wallet & music player. Stores up to 400 hours of video, 250 movies or<br />
1 million photos.<br />
Pearpoint Flexi-Cam Pipeline Inspection<br />
System<br />
PEA-FLEXI-CAM MY<br />
Compact colour video 25mm colour camera<br />
with 3lux sensitivity, (light source white LED’s)<br />
on 15m of fully retracting flexi-rod. Flexi-cam<br />
navigates multiple 90º bends in 32mm pipes<br />
and images are displayed on the internal<br />
colour TFT screen. Images can be recorded to<br />
an external video recorder (not supplied). System operates from internal<br />
fully rechargeable batteries which provide up to 5h of continuous use when<br />
fully charged. Hand-held portability. Fully waterproof, manually set focus<br />
camera. Inspects pipes 25 to 100mm.<br />
Testo Fibrescope 1.2m with Guide Tube<br />
TES,319 (5119) AU<br />
Supplied with guide tube, 45 degree mirror &<br />
magnetic tip. Number of pixels 6,000. Fibreoptic<br />
field of view 50°. Angle of field of view<br />
45° ±5°. Min focus distance 15mm (focus).<br />
Max focus distance 150mm (light). Operating<br />
and storage temperature: -20° to 60C. Working temperature/probe<br />
-20° to 80°C. Probe diameter 6.5mm. Probe length 1247 mm ±6. Max<br />
bending radius 50mm. Light source LED 2 point light. Probe resistance:<br />
probe tip water-proof up to handle short-term resistance to silicone oils,<br />
petrol and kerosene. Oils or petrol must be wiped off immediately after<br />
immersion. Battery type 3AA batteries. Battery life 4h. Note: the<br />
magnetic tip can be used to remove small magnetic objects.<br />
Vivax Pipeline Camera Inspection System<br />
VIV,VCAM-60M (5110) AU<br />
Pipeline camera inspection system with self levelling<br />
D46/SL and D33/SL cameras which are 60mm and<br />
41mm in diameter respectively installed in a stainless<br />
steel rugged housing. Will record MPEG4 videos and<br />
the provided keyboard allows titling of up to 16 pages<br />
of text together with audio commentary. Can be<br />
uploaded via the USB interface to a computer allowing<br />
copies to be made for the client and or images to be<br />
captured for inclusion in reports. Camera includes a<br />
sonde with 512Hz, 640Hz and 33kHz modes.<br />
Wohler VIS2000Pro 30m x 51mm Colour<br />
Camera & Roller Guide<br />
WOH,VIS2000PRO (5112) AU<br />
Suited for inspection of ventilation ducts, chimneys,<br />
chambers and flue gas systems, etc. Kit consists<br />
of colour display with a joy stick to control camera.<br />
30m push rod cable on a reel, with a non-waterproof,<br />
splash resistant, (IP64) 51mm diameter colour<br />
camera with illumination. Accessories include<br />
a Roller Guide to allow the camera to be pushed<br />
down a pipe. Can save still and video images to a<br />
memory card. Video out function.<br />
68<br />
Pipeline & Cavity Inspection cont’d.<br />
Wohler VIS250 Service Camera<br />
Visual Inspection System<br />
WOH,VIS250-S CAMERA (5116) AU<br />
Compact colour video pipeline inspection system, 26mm<br />
colour camera with bright white LED’s on 30m of flexible<br />
push rod with metric marking. Camera sensitivity 3Lux,<br />
lens f=2.5mm, F=2.0, view angle 120°, waterproof to 3m<br />
water depth. Suitable for insertion in pipes and spaces<br />
from 40 to 150mm diameter. Supplied with 2 battery packs and an AC charger/<br />
power pack, each battery pack lasts approx 1.5h. Supplied with 5.6” TFT display<br />
with extension cable, video output suitable for video recorder (not supplied).<br />
Wohler VIS340 Service Camera Visual<br />
inspection System<br />
WOH,VIS340 (5117) AU<br />
Compact colour Video Inspection System, 26mm<br />
colour camera with bright white LED’s on 30m of<br />
flexible push rod with metric marking. View angle<br />
120 degree, waterproof according to IP68. 7” high<br />
resolution colour screen with integrated SD video<br />
recording. Suitable for insertion in pipes and spaces<br />
from 40 to 150mm diameter. Battery powered. Applications include damage analysis<br />
in water / drainage / sewer pipes, inspection of hollow spaces, ventilation, machines,<br />
control panels, exhaust systems and production surveillance.<br />
Material Moisture Meters<br />
www.techrentals.com.au<br />
See also Concrete Testing Equipment PRO,MMS-PLUS on page 66<br />
Protimeter SM Moisture Meter<br />
PRO,SM (4954) AU<br />
Moisture meter for survey work. Very good for determining wet points. Will<br />
provide % moisture content for timber. Subsequent accurate measurements<br />
can then be made.<br />
Distance Measurement & Surveying<br />
Hilti PD38 Laser Distance Measurement with PDA<br />
HIL,PD38 (5321) AU<br />
Laser distance measurement with Bluetooth. The kit<br />
includes a PDA with a camera. It can take an image and<br />
directly transfer the dimensions from the PD38 to the<br />
image. Readings can also be transferred directly to an<br />
Excel spreadsheet. Battey 2 x AA accuracy ±1.5mm.<br />
Minimum measuring distance .05m, maximum 200m<br />
with target (70m without target). Includes optical site.<br />
Leica Disto Pro Laser Distance Measurement<br />
LEI,DISTOPRO (5320) AU<br />
Typical accuracy ±3mm. Will average over 8 measurements for greater accuracy.<br />
Built in function for height measurement and enclosed angles, etc.<br />
Memory can be divided into groups, e.g. 200 groups with 5 measurements.<br />
Includes PC interface and software, telescope to help find dot in daylight and<br />
bubble level to enable horizontal measurement.<br />
Solmetric Suneye 210 Shade Analysis Tool<br />
SOL,SUNEYE210 (5350) AU<br />
Integrated Shade Analysis Tool for solar site assessment.<br />
Includes a fisheye lens on a digital camera and a dedicated<br />
on-board processor to perform digital image processing<br />
and analysis to compute shading and solar access<br />
percentages. Includes an electronic compass and level,<br />
and an inclinometer function for measuring roof pitch<br />
and azimuth. Also includes a GPS system to accurately<br />
determine latitude and longitude.
MANAGED SERVICE RADIO SOLUTIONS<br />
Tired of two-way radios that don’t work properly?<br />
Looking for someone to manage your on-site communication needs?<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Why go with TR:<br />
<br />
<br />
<br />
<br />
<br />
bearcom<br />
no1 in radio solutions<br />
<br />
www.trbearcomrental.com.au<br />
<br />
TR Managed Service on 1800 246 990<br />
69<br />
BE0105
ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Environmental Gas & Vapour Meters<br />
Personal Gas & Vapour Monitors<br />
Airborne Dust & Particle Meters<br />
Air Quality & Heat Stress<br />
Moisture & Humidity Meters<br />
Noise & Sound <strong>Analysers</strong><br />
Radiation Monitoring & Protection<br />
Floor Slip Testers<br />
Water Quality, pH Meters & Eletrochem<br />
Light Meters, UVA/B/C Measurement<br />
Weather Stations<br />
Environment Flow Meters<br />
Laboratory & Hand-held Microscopes<br />
Balances & Scales below 8kg<br />
Chemical & Analytical - General<br />
Laboratory Instruments, Spectroscopy<br />
Environmental Gas & Vapour Meters<br />
See also Combustion, Flue & Industrial Gas <strong>Analysers</strong> on page 57<br />
Aeroqual 500L Portable Logging Ozone Monitor<br />
AER,500L (5958) AU<br />
Portable ozone monitor fitted with low concentrationrange<br />
detection head. Operating range 0 to 0.5ppm<br />
ozone with display in ppm or mg/m 3 . Gas sensitive<br />
semiconductor [GSS] sensor for accurate low-level<br />
measurements, T90 response approximately 100s.<br />
Operation from mains power supply or battery pack<br />
(4h operation). Internal data logging for 8,000 points<br />
with software and cable for download to PC, or data<br />
logging direct to PC. Application for indoor air quality<br />
measurements.<br />
Odalog ODA6000CP NO2 & CO Area Monitor for Vehicle-parks & IAQ<br />
APT,ODA6000CP (5972) AU<br />
Portable multi-gas monitor for area air-quality measurement, logging or<br />
<br />
for carbon monoxide (from petrol vehicles) and nitrogen dioxide (from diesel<br />
vehicles). Ranges CO 0 to 500ppm (to 1ppm) and NO 2 0 to 50ppm (to 0.1ppm).<br />
Dust and water sealed to IP66, and rated intrinsically safe for general or mines<br />
use. Logging memory 500K readings. Integral infrared communications<br />
<br />
Rechargeable, approximately 7 days operation on full charge.<br />
Haloteck 78000 Refrigerant Gas Leak Detector<br />
HAL,78000 (5804) AU<br />
For use by refrigeration engineers. Rapid response 0.2s, audio output,<br />
zero warm up time. Single control, battery operated, sensor tip insensitive<br />
to draughts. Sensitivity better than 3g/y R12, 25g/y R134A. Responds to<br />
halogenated hydrocarbons and many fire extinguishant gases, [also sulphur<br />
hexafluoride SF6]. Battery life 30h. Duty cycle continuous. Probe length<br />
240mm. Weight 280g.<br />
70<br />
www.techrentals.com.au<br />
Environmental Gas & Vapour Meters<br />
cont’d.<br />
GasCheck 3000 Portable General-Purpose Leak Detector<br />
ION,GASCHECK3000 (5906) AU<br />
Micro thermal-conductivity sensor for high-sensitivity detection of gases with<br />
a thermal conductivity different to that of air, including helium, carbon dioxide,<br />
refrigerants, sulphur hexafluoride, natural gas, etc in 5 groups. Direct reading<br />
of leak rate in ml/sec with audio and visible signals. Detection limit for helium<br />
2E-5ml/s. Battery <strong>Power</strong>ed.<br />
Ion Science Gascheck Helium, Butane<br />
& SF6 Detector<br />
ION,GASCHECKG3 (5907) AU<br />
Microthermal conductivity gas detector. Reading in<br />
cc/s, g/yr, mg/m 3 or ppm. Detects most gases however<br />
particularly suited to ammonia, argon, butane, helium,<br />
hydrogen & SF6. Calibrated against Helium. Battery<br />
Life 40h. Sensitivity (cc/s) He 1x10-5, CH4 5x10-5,<br />
R12 5x10-5, Ar 1x10-4. Accuracy 5% of displayed<br />
reading + 1 digit. Response 1s. Flow rate 2cc/min. Operating -20 to 60°C.<br />
Data logging, stores 10 readings.<br />
ISC MDU420 Logging Methane Monitor<br />
ISC,MDU420 (5956) AU<br />
Dual-range methane monitor with non-dispersive infrared sensor. Low range<br />
0 to 100% LEL, and auto-range 0 to 100% methane by volume. Internal pump<br />
for ambient air or stream sampling. Data logging included, with software and<br />
cable for download. Supplied with 450mm stainless steel probe for flue gas<br />
analysis. Rechargeable, with alkaline-battery pack as backup.<br />
Oldham MX21 Plus Gas Monitor for Sulphur Dioxide SO 2<br />
OLD,MX21-SO2 (5936) AU<br />
Portable gas detector for personal, workplace or space monitoring of sulphur<br />
dioxide (SO 2 ) in the range 0 to 30ppm. Operation in passive or pumped modes,<br />
with sampling tube and flexible probe. Data logging, with software included for<br />
download to serial printer or computer. Rolling storage of up to 48h data (at<br />
1min intervals) in multiple groups. Rechargeable battery.<br />
Photovac 2020 Portable PID VOC Monitor<br />
PHO,2020PRO (5950) AU<br />
Portable handheld VOC (Volatile Organic Compound) monitor with data<br />
logging. PID sensor (Photo-Ionisation Detector) fitted with 10.6eV lamp.<br />
Ranges 0.5~2000ppm humidity compensated. Downloadable data logging for<br />
15,000 points with time, data and header. Intrinsically safe.<br />
PPM 400 Portable Formaldehyde Meter<br />
PPM,FORM400 (5962) AU<br />
Portable Formaldehyde meter for measuring<br />
airborne formaldehyde in the workplace.<br />
Electrochemical sensor, with internal pump<br />
for rapid response. Operating range 0.05 to<br />
10ppm with readout on 4 digit LCD display.<br />
Kit includes field calibration standard.<br />
Operates from 9V alkaline battery.<br />
RAE Systems Minirae 2000 Portable PID<br />
RAE,MR2000 (5950) AU<br />
Portable handheld VOC (Volatile Organic<br />
Compound) monitor with data logging. 3-D PID sensor (Photo-<br />
Ionisation Detector) fitted with 10.6eV lamp. Ranges 0 to<br />
999ppm (resolution 0.1) or 100 to 10,000ppm (resolution 1)<br />
VOC expressed as isobutylene. Built-in correction factors for<br />
102 compounds from a total standard library of 250. Integrated<br />
pump for local or remote (30m) sampling, with stall protection<br />
against liquid ingress. Downloadable data logging for 1,500<br />
points with time, data and header. Intrinsically safe. Up to 10h<br />
operation with rechargeable (NiMH) or alkaline batteries.
www.techrentals.com.au ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Environmental Gas & Vapour Meters<br />
cont’d.<br />
Minirae 3000 Advance Handheld VOC Monitor<br />
RAE,MR3000 MY<br />
Handheld volatile organic compound (VOC) detector.<br />
Photoionization Detector’s (PID) extended range of 0 to<br />
15,000 ppm, ideal For applications from industrial hygiene,<br />
to leak and HazMat detection. RF modem allows real-time<br />
data transmissions with a base controller located up to 500<br />
feet (or two-miles with optional RAELink3 portable modem)<br />
away from the MiniRAE 3000 detector. A personal computer<br />
can be used as the base station for a Mini-RAE 3000 system.<br />
Personal Gas & Vapour Monitors<br />
BW Bump & logging download for<br />
BW,MICROCLIP<br />
BW,BUMP (5938) AU<br />
Automatic calibration testing and data management<br />
system for the BW microclip gas detection equipment.<br />
Carries out fully automatic “hands-free” calibration and<br />
functional bump test. It also enables data collected<br />
during operation of the BW microclip to be downloaded.<br />
BW Gas Alert Micro Clip Confined Space 4 Gas<br />
Detector<br />
BW,MICROCLIP (5937) AU<br />
Continuous LCD shows real time gas concentrations.<br />
Simple 1 button operation. Measures:- H 2 S 0 to 100ppm<br />
(1ppm resolution), CO 0 to 500ppm (1ppm resolution),<br />
O 2 0 to 30% (0.1% resolution) and Combustible gases<br />
0 to 100% LEL (1% resolution), 0 to 5% v/v (0.1% resolution). Alarms:- visual,<br />
vibrating and audible (95dB), Low, High, STEL, TWA and OL (over limit).<br />
Lithium polymer battery life 12h (typical) recharge time
ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Air Quality & Heat Stress<br />
Casella Microtherm WBGT Area Heat Stress<br />
Monitor<br />
CAS,MICROTHERM (5868) AU<br />
Portable area heat stress WBGT monitor with<br />
real-time graphical display. Measures heat stress<br />
potential [WBGT index] according to ISO7243.<br />
PRTD sensors with internal calibration-reference<br />
for wet-bulb, dry-bulb and globe temperatures.<br />
Large LCD display for numerical or graphical indication of temperatures and<br />
processed values for WBGT [indoor/outdoor plus TWA], relative humidity and<br />
dewpoint. Simple keypad/menu setup. Data logging for up to 32 separate<br />
runs and 49,100 records, with interval 30s to 1h. RS232C port with included<br />
PC software for download and reporting or realtime display. Low water-level<br />
warning, and settable audible/visible WBGT alarm. Handheld, free-standing<br />
or tripod-mount. Battery operated.<br />
Testo 635-2 Humidity, Temperature & Dewpoint Meter<br />
TES,635-2 (5859) AU<br />
Portable humidity meter fitted with robust stainless probe<br />
with sintered filter-cap for general or duct measurements to<br />
120ºC, and fast-action K-type surface temperature probe.<br />
Displays relative humidity, absolute humidity, dew point,<br />
degree of humidity, enthalpy, temperature, and differential<br />
temperature (dewpoint to surface). Operating range 2 to<br />
98%RH (±2%). Air temperature -20 to 120ºC (±0.2/0.5).<br />
Surface temperature -60 to 300ºC (±0.1). Internal memory<br />
for 10,000 values with USB interface, cable and software<br />
for download and presentation. Battery operated.<br />
Testo 645 Humidity & Dewpoint Meter<br />
TES,645-1 (5858) AU<br />
Portable humidity meter fitted with robust stainless<br />
probe for ambient work or duct measurements<br />
to 120°C. Displays relative humidity, absolute<br />
humidity, dew point, degree of humidity, enthalpy<br />
and temperature. Operating range 2 to 98%RH<br />
[±2%], -20 to 120°C [±0.4/0.5]. Battery operated.<br />
TSI Q-TRAK IAQ Monitor CO 2 ,<br />
CO Temperature & Humidity Logger<br />
TSI,7565 (5861) AU<br />
Measures CO 2 0 to 5,000ppm ±3%, temperature<br />
0 to 60ºC ±0.6ºC, humidity 0 to 95% ±3%, CO 0 to<br />
500ppm ±3% and barometric pressure 517.15 to<br />
930.87mmHg ±2%. Calculates dew point, wet bulb<br />
and percent outside air. Displays 5 measurements<br />
simultaneously. User selectable logging interval and<br />
start stop times. Stores 39 days data at 1min intervals<br />
56,035 data points. This unit also has external<br />
thermocouple measurements.<br />
TSI Q-Trak plus Indoor Air Quality Monitor with<br />
Logging<br />
TSI,8554 (5860) AU<br />
Indoor air quality (IAQ) monitor for temperature and<br />
humidity measurements, CO and CO 2 concentrations.<br />
Humidity range 0 to 95%, temperature range 0 to<br />
50°C. Electrochemical cell for CO 0 to 500ppm.<br />
NDIR cell for CO 2 0 to 5,000ppm. Data logging for<br />
48,671 data points with interval adjustable 1s to 1h.<br />
Fitted with RS232 interface, and software included<br />
for download, storage and reporting. Battery or<br />
mains operation with AC adaptor.<br />
72<br />
Moisture & Humidity Meters<br />
GE Panametrics PM880 Industrial<br />
Moisture Analyser<br />
PAN,PM880 (6119) AU<br />
Intrinsically safe moisture analyser for<br />
compressed air systems, non-corrosive gases &<br />
hydrocarbons such as natural gas (IS certification<br />
to ATEX and CSA). Displays dew point, moisture<br />
concentration, pressure & temperature. Dew point<br />
calibrated measurement range -80 to 20°C with<br />
data to -110°C. Pressure range 7 to 69bar limited<br />
by sensor, gauge and safety-valve (operating range from 5μHg). Temperature<br />
range -30 to 70°C. Gas flow operating range from static to 10,000cm/s velocity.<br />
Supplied with compact sample system with gauge, safety-valve, sampling<br />
valves and fittings (¼” Swagelok). Data logging of up to 100K moisture points,<br />
with infrared port and software for download. Battery powered only (15-24h<br />
operation) with second battery and charger (note charger is not IS).<br />
Noise & Sound <strong>Analysers</strong><br />
See also Vibration Analysis on page 62<br />
www.techrentals.com.au<br />
ARL EL-315 Environmental Noise Logger<br />
ARL,EL-315 (5694) AU/MY<br />
Portable, self-contained and weatherproof with display<br />
for field reading of summary results. Continuous<br />
90dB dynamic range, frequency weightings A and C.<br />
Monitors environmental noise continuously for up to<br />
3 weeks, calculates and stores over 7,500 sets of Ln<br />
indices. PC required to set up system and download<br />
data using software supplied. Set up also possible<br />
from front-panel.<br />
ARL EL-316 Environmental Noise<br />
Logger Type 1<br />
ARL,EL-316 (5695) AU<br />
Environmental noise logger with display for fieldreading<br />
of summary results. Portable, self-contained<br />
and weatherproof. Type 1 performance, continuous<br />
90dB dynamic range, fast response, frequency<br />
weightings A and C. Monitors environmental noise<br />
continuously for up to 3 weeks, calculates and stores<br />
over 7,500 sets of Ln indices. PC required to set up<br />
system and download data using software supplied.<br />
Set up also possible from front-panel.<br />
ARL NGARA Environmental Noise Logger<br />
ARL,NGARA (5690) AU<br />
Can be configured to record all sound continuously<br />
so noise data can be post processed. It can prove<br />
logged data, WAV data & alarm/triggered details.<br />
Type 1 microphone provided.<br />
B&K 2237A Type 2 Integrating Sound Level Meter<br />
BK,2237A (5661) AU<br />
Measures RMS and peak simultaneously. Linearly weighted<br />
analogue output for sound recording, 0 to 0.5VAC (RMS). Measurement<br />
range 30 to 140dB. Time weightings fast, slow & impulse. Independent<br />
frequency weightings A [for RMS readings SPL, MaxL, MinL, Leq, Inst] and<br />
C [for peak readings Peak and MaxP]. Real time clock for time and date<br />
stamp. Records 40 measurements for download to PC. Calibrator included.<br />
Battery operated.
www.techrentals.com.au ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Noise & Sound <strong>Analysers</strong> cont’d.<br />
B&K 2238E Type 1 Integrating SLM Enhanced Software &<br />
Logging<br />
BK,2238E-NATA (5678) AU<br />
Type 1 (class 1) Integrating sound level meter with additional functions<br />
including enhanced software, frequency analysis and data logging.<br />
Standard routines include functions for workplace measurements<br />
and general sound-level checks; enhanced software (firmware) offers<br />
additional measurements and statistics for assessment of environmental<br />
noise problems; frequency analysis automates measurements in the<br />
9 single octave bands and 29 1/3 octave bands. Supplied with field<br />
calibrator. Compatible with BK,7815 Noise Explorer Environmental<br />
software for download, data analysis and display.<br />
B&K Noise Monitoring Terminal<br />
with model 2238F SLM<br />
BK,2238NMT-KIT (5696) AU<br />
Noise logging system with B&K model 2238F Class 1<br />
Sound Level Meter equipped with internal software for<br />
Basic SLM and Logging. Portable, wheeled weatherproof<br />
case. Standard SLM operation for fast, slow and impulse<br />
time weightings and A, C or linear frequency weightings<br />
RMS. Linear or C frequency weightings for peak<br />
detection. Internal memory 2MB total for logging up to 12<br />
parameters including auxiliary signals. Fitted with serial<br />
RS232 interface, and provided with BKlink software for<br />
download of logged data to PC. Supplied with field calibrator, charger and<br />
12V, 18Ah battery, for operation for up to 14 days logging at 15min intervals.<br />
B&K 2239A Type 1 Sound Level Meter NATA Certification<br />
BK,2239A-NATA (5667) AU<br />
Type 1 (class 1) integrating sound level meter with backlit LCD<br />
display, NATA certification. Simultaneous RMS (A,C) & peak (C) detection<br />
with independent frequency weightings. Measuring range 30 to 140dB.<br />
Time weightings fast, slow and impulse. Parameters Leq, MaxP, MaxL,<br />
MinL, Peak, SPL and Inst. Memory for 40 data records with realtime clock.<br />
Serial port for data download. Calibrator included. Operates with 4 x AA<br />
alkaline batteries.<br />
B&K 7815 Environmental Software - Noise Explorer<br />
BK,7815 (5688) AU<br />
Software package for downloading and reporting of noise data measured<br />
with B&K meters. Compatible with sound level meters (2239, 2238) and<br />
noise dosemeters (4443). Offers data transfer, formatting of data for<br />
export, display and print in tabular or graphical form, file management<br />
and calculation of sound power or sound reduction index from intensity<br />
measurements.<br />
Ivie IE-35 Type 1 Audio Analysis Systems<br />
IVI,IE35-2P (5682) AU<br />
Audio Analyser with Dell Axim X51v PDA. Fitted with<br />
half-inch free-field Type 1 microphone and pre-amplifier.<br />
Functions include SPL (sound level), Real-time analysis,<br />
“seat-to-seat” variation for audio setup, reverberation<br />
measurement, “strip-chart” recording on display, voltage<br />
and oscilloscope displays and signal generation. Supplied<br />
with field-calibrator, microphone extension cable, spare<br />
battery and software for data-download to PC. SPL<br />
facilities include time and frequency weightings - fast,<br />
slow, peak or impulse and A, C or Flat. FFT based Real<br />
Time Analysis includes 1/1, 1/3, or 1/6 octave bands with<br />
a maximum resolution of about 1/24 octave. Additional<br />
functions include spectrum subtraction, averaging, Noise<br />
Critera or Reduction contours and reverberation-decay to ISO-20 and ISO-<br />
30. Signal-generation includes sine, square, triangle and white or pink noise.<br />
73<br />
Noise & Sound <strong>Analysers</strong> cont’d.<br />
Digital Audio Test Set<br />
comprising of NTI Digirator &<br />
NTI Digilyser<br />
NTI,NT-DAS (5684) AU<br />
Audio Excel Line for digital audio signals. System<br />
including the Digilyzer and Digirator for producing<br />
digital audio signals and analysing those digital<br />
audio signals up to and including 5.1 surround<br />
sound. Up to 192kHz 24bit, AES3,S/PDIF, TOSLINK & ADAT. ync input<br />
(AES3, Word Clock, Video). Supports Dolby Digial, E, PL II, DTS. Channel<br />
transparency check. Channel delay measurement<br />
Quest 2400 Type 2 Sound Level Meter<br />
QUE,2400 (5660) AU<br />
Type 2 sound level meter with LCD display for sound pressure level [SPL]<br />
or maximum level [MAX]. Frequency weightings A and C, time weightings<br />
Fast and Slow. Ranges 30 to 140dBA and 40 to 140dBC with overload<br />
indication. AC and DC outputs. Battery powered.<br />
Rion NL-04 Sound Level Meter<br />
RIO,NL-04 MY<br />
Meets IEC type 2. Five measurement functions: Lp(SPL), Leq, LAE, Lmax<br />
& Lx(L5,L10,L50,L90,L95). 6 automatic measurements & data store. Built-in<br />
RS232C interface for computer communication. 70dB dynamic range (digital<br />
display), 27 to 130dB (A) measuring range. Wide range of time settings for<br />
Leq, LAE, Lmax & Lx; 10s, 1, 5, 10, 15, 30min, 1, 8, 24h & manual time<br />
setting (up to 99h 59min 59s). RMS: fast, slow,10ms. 4 digit LCD display,<br />
0.1dB resolution, updated every second, plus 60dB analogue display display<br />
1dB resolution showing the instantaneous value. Memory battery back-up.<br />
AC & DC signal o/p for level expanding system by optional filters, memory<br />
card & others.<br />
Rion NL-05 Type 2 Sound Level Meter<br />
RIO,NL-05 (5664) AU<br />
Sound level meter to IEC 651/1979 & IEC 804/1985 type 2 requirements.<br />
Measures Lp, Lmax, Leq, Lae. Response types A, C, and flat. Fast and slow<br />
time weightings. Complete with calibrator. Internal memory and print-out<br />
for Leq data (printer CP-10 optional, also prints other parameters), RS232C<br />
interface. Recorder outputs 1VAC RMS & 3.5VDC. Operates from batteries<br />
or AC adaptor.<br />
Rion NL-32 SLM with RTA & NATA Certification<br />
RIO,NL-32RTA-NATA (5674) AU<br />
RIO,NL-32RTA MY<br />
Precision integrating sound level meter to IEC type 1<br />
(class 1) specification, with NATA calibration. Fitted with<br />
internal Compact Flash Card reader and supplied with<br />
NC-74 field calibrator. Frequency range 20 to 20,000Hz<br />
with weightings A, C, and flat. Time weightings fast,<br />
slow and impulse. Measurement range (A) 28 to 138dB.<br />
Broadband measurement functions Lp (SPL), Leq, Lmax/<br />
min, Lae, Lx, and selectable auxiliary functions with manual or auto storage<br />
[logging]. Measurement time (Leq) from 10s to 200h. Inbuilt memory for up to<br />
100 data sets, or to limit of fitted CF card using manual or auto storage. AC<br />
or DC outputs, RS232C interface and cable CC-93 for serial printer. Supplied<br />
with NX-22RT card for real time 1/1 and 1/3 octave analysis and display, for<br />
measurement functions Lp, Leq, LE, Lmax and display of AP (all-pass) AP(A)<br />
and 1/1 or 1/3 octave values as selected, with manual data storage only to NX-<br />
22RT card. Download of card-data to PC requires flashcard reader. Alkaline<br />
batteries (24h operation) or AC adaptor.<br />
Save your time and reduce your real costs.<br />
Find out all <br />
solutions on page 11.
ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Radiation Monitoring & Protection<br />
See also E & H Field Strength Meters on page 13<br />
Fluke 481 Radiation Survey Meter<br />
FLU,481 (5580)<br />
Provides exposure measurements in mR/hr to 50R/h<br />
(0.55v/hr). Detects skin-dose, deep-dose and X-ray<br />
radiation. Measures dose & dose rate.<br />
HPI Cypher 5000 Digital Radiation Alert<br />
Monitor<br />
HPI,CYPHER5000 AU<br />
Alpha, Beta, Gamma and X-ray radiation monitor.<br />
Meter, LED, audible indication and detachable<br />
probe. Range 0.1 to 1,000,000 CPM; Accuracy<br />
1% or 2 digits.<br />
Narda 8217 Microwave Oven Survey Meter<br />
NAR,8217 (5553) AU<br />
For oven power measurement complete with beaker and thermometer.<br />
Calibration frequency 2.45GHz. Measurement range 0.5 to 10mW/cm 2 .<br />
Battery operated.<br />
W&G RadMan ESM-20 Personal RF Field<br />
Radiation Monitor<br />
WG,ESM-20 (5557) AU<br />
Personal monitor and leakage detector<br />
for high frequency electromagnetic fields.<br />
Simultaneous E and H field measurements with audible and visual alarms.<br />
Frequency range H field 1MHz to 1GHz; E field 1MHz to 40GHz. Operation<br />
as personal monitor with compensation for human body absorption, or with<br />
isotropic detection for RF leakage sensing and simple four-level measurement<br />
using LED indicators. Battery powered. Battery life over 200h.<br />
Floor Slip Testers<br />
Severn Model Tortus II<br />
Floor Slip Tester<br />
SEV,TORTUSII (5505) AU<br />
Floor friction tester. Measures and<br />
records the dynamic coefficient of<br />
friction. Applications in assessing floor<br />
safety, evaluating cleaning methods and maintenance procedures, accident<br />
investigation, etc. Meets the draft requirements of international, Australian and<br />
New Zealand standards.<br />
Water Quality, pH Meters<br />
& Electrochem<br />
DKK TOA Model RC-24P Portable Residual<br />
Chlorine Meter<br />
DKK,RC-24P-DP (6046) AU<br />
Portable, direct-reading residual chlorine meter for<br />
water analysis. Range 0 to 2mg/L [ppm]. Reagentfree<br />
measurement with electrode, 3m cable, float<br />
and sample container for in-situ or grab-sampling.<br />
Compatible with direct chlorination, hypochlorite<br />
or dichloroisocyanurate dosing. Calibration data<br />
stored in electrode with correlation with DPD<br />
methods. Waterproof to IP67. ISO validation<br />
functions, storage of 300 measurements and<br />
RS232 printer output. Battery operated.<br />
74<br />
Water Quality, pH Meters<br />
& Electrochem cont’d.<br />
www.techrentals.com.au<br />
Horiba U-52 Multi-function Water Quality Meter<br />
HOR,U-52-10M (6025) AU<br />
Measures pH range 0 to 14pH, resolution 0.01, accuracy ±0.1. Oxidation<br />
reduction potential (ORP) range -2,000mV to 2,000mV, resolution 1mV,<br />
accuracy ±15mV. Dissolved oxygen (DO) range 0 to 50mg/l, resolution 0.01,<br />
accuracy 0 to 20mg/l ±0.2 and 20 to 50mg/l ±0.5. Conductivity range 0 to<br />
100mS/cm, resolution 0.001 to 0.1 depending on scale, accuracy ±1%F.S.<br />
Salinity range 0 to 70ppt, resolution 0.1, accuracy ±3ppt. Total dissolved solids<br />
(TDS) range 0 to 100g/l, resolution 0.1%F.S., accuracy ±5. Seawater specific<br />
gravity range 0 to 50 sigma t, resolution 0.1, accuracy ±5. Temperature<br />
range -5 to 55ºC, resolution 0.01, Turbidity (Turb) 0 to 800NTU, resolution<br />
0.1, accuracy ±5% (reading) or ±1NTU whichever is the greater. The probe<br />
diameter is 96mm the cable length is 10m.<br />
Hydrolab Minisonde 5 Multiprobe Water Logger<br />
HYD,MS5 (6024) AU<br />
Microsonde 5 multiprobe water/borehole logger,<br />
including ‘Surveyor’ data collection system with<br />
GPS. Includes sensors for Dissolved Oxygen<br />
(HACH LDO), Conductivity, pH, Redox (ORP),<br />
Turbidity (Self Cleaning), Temperature, Depth (0<br />
to 25m) & GPS position. Includes the surveyor<br />
data aquisition system so no laptop is needed for<br />
download or data collection. Includes a 25m cable.<br />
ISCO 6700 Series Water Sampler<br />
ISCO,6712 (6057) AU<br />
Advanced water sampler for fully programmed<br />
collection. Samples are collected in up to 24<br />
disposable plastic containers based on time, flow,<br />
and/or parameter set points. Fitted with NEMA 4X,6<br />
(IP67) sealed controller featuring an exclusive,<br />
built-in pump.<br />
Isco 6700 Series Water Sampler with Bubbler<br />
Flow Module<br />
ISK,6700-730 (6056) AU<br />
Advanced water sampler for fully programmed<br />
collection. Samples can be collected in 1, 2, 8, or<br />
24, 1 litre disposable sample containers based on<br />
time, flow, and/or parameter set points. Fitted with<br />
NEMA 4X,6 (IP67) sealed controller featuring an<br />
exclusive, built-in pump, flash memory for easy<br />
programming changes, and a plug-in module port<br />
for connection of a flow meter module or parameter measurement module to<br />
enhance monitoring capabilities. Provided with bubbler flow module. Sample<br />
bottles available. Run from rechargeable 12V sealed batteries.<br />
OTT KL010-150 Ground-water Depth Measurement Contact Gauge 150m<br />
OTT,KL010-150 (6065) AU<br />
Contact gauge for portable depth to water measurement. Used for wells,<br />
observation pipes, bore holes and control pumping tests. 150m depth of tape.<br />
as soon as the probe touches the water surface an acoustic signal beeps and<br />
the lamp on the instrument lights up. The depth is read from the measuring<br />
tape in meters.<br />
Solinist Oil/Water Interface Meter<br />
SOL,122 (6066) AU<br />
Used for bore determination of LNAPL or DNAPL levels. Flat tape on a reel<br />
when lowered down a bore hole a light and tone indicate the LNAPL (Light<br />
Non-Aqueous Phase Liquid) layer or the DNAPL (Dense Non-Aqueous Phase<br />
Liquid) level. The level is measured from the 50m tape.
www.techrentals.com.au ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Water Quality, pH Meters<br />
& Electrochem cont’d.<br />
TPS 90FL-T Water Quality Meter<br />
TPS,90FL-T (6028) AU<br />
Field meter and logger for water quality<br />
measurements. Configured with independent<br />
probes for pH, conductivity/salinity[TDS]/<br />
temperature, dissolved oxygen[DO] and<br />
turbidity. Cables 5m with probe holder and<br />
safety harness. LCD display readout with<br />
simultaneous display of all measurements.<br />
Manual, “notepad” storage or automated data logging for up to 1,808 sets of<br />
readings by time and date. RS232C interface, with WinTPS software included.<br />
Supplied with rechargeable battery, and clip-lead for operation from a 12V<br />
source such as a car-battery.<br />
TPS Conductivity Probe With Cell K 0.1<br />
TPS,LOW K PROBE ( 6016) AU<br />
Plastic-bodied conductivity and temperature sensor for WP series meters.<br />
With k=0.1 and automatic temperature compensation ATC. For precision<br />
measurement at low conductivity levels. Minimum range with WP-84 2 uS/cm<br />
to 2,000uS/cm. Temperature range -10 to 60°C. Fitted with 5m cable.<br />
TPS Redox Electrode<br />
TPS,REDOX (6004) AU<br />
Silver/chloride Redox electrode for use with TPS LC80A Ph meter. Supplied<br />
with 2 bottles of Zobell solution for calibration. 1:1 dilution gives approx.<br />
231mV.<br />
TPS WP-80 pH and Temperature Meter<br />
TPS,WP-80 (6003) AU<br />
Portable hand-held meter for pH, mV and<br />
temperature. Supplied with combination pH<br />
electrode and separate temperature sensor on<br />
1m cables. Operating ranges 0 to 14pH and<br />
-10 to 120ºC (automatic sensor recognition<br />
with auto pH correction 0 to 100ºC).<br />
Case water resistant to IP67, connectors to IP65. Menu driven, with<br />
alphanumeric display. Auto storage of time and date of last calibration<br />
for GLP. Memory for 2400 readings of data, time and date, for Notepad<br />
results collection, or for AutoLog with logging intervals between 1s<br />
and 90h. Fitted with RS232C interface and supplied with downloadsoftware,<br />
charger and solutions. Rechargeable NiMH battery gives up to<br />
50h operation.<br />
TPS WP-80 pH and Temperature<br />
Meter for Testing Meat<br />
TPS,WP-80M (6002) AU<br />
Portable hand-held meter for pH, mV and temperature.<br />
The instrument is capable of applying Bendalls<br />
equation to the pH reading for Meat Standards<br />
Australia grading requirements. Supplied with<br />
combination pH electrode and separate temperature<br />
sensor on 1m cables. Operating ranges 0~14pH and<br />
-10~120ºC [automatic sensor recognition with auto<br />
pH correction 0~100ºC]. Case water resistant to IP67, connectors to IP65.<br />
Menu driven, with alphanumeric display. Auto storage of time and date of<br />
last calibration for GLP. Memory for 2400 readings of data, time and date, for<br />
Notepad results collection, or for AutoLog with logging intervals between 1s<br />
and 90h. Fitted with RS232C interface and supplied with download-software,<br />
charger and solutions. Rechargeable NiMH battery gives up to 50h operation.<br />
75<br />
Water Quality, pH Meters<br />
& Electrochem cont’d.<br />
TPS WP-82 Dissolved Oxygen Meter<br />
TPS,WP-82 (6009) AU<br />
Portable hand-held dissolved oxygen and<br />
temperature meter. Operating ranges 0<br />
to 20ppm, 0 to 240% saturation, 0 to 45%<br />
gaseous and ppm with salinity correction.<br />
temperature range -10 to 120°C. Case water<br />
resistant to IP67, connectors to IP65, with<br />
3m detachable cable and ED1 electrode.<br />
Menu driven, with alphanumeric display. Auto<br />
storage of time and date of last calibration for<br />
GLP. RS232C interface, and memory for 150 readings of data, time and date,<br />
for Notepad results collection, or for AutoLog results collection with logging<br />
intervals between 1min & 24h. Rechargeable NiMH battery gives up to 75h<br />
operation. Supplied with download-software, charger and solutions.<br />
TPS WP-84 Conductivity Salinity<br />
Temperature Meter<br />
TPS,WP-84 (6014) AU<br />
Portable hand-held meter for conductivity,<br />
TDS (Total Dissolved Solids) and<br />
temperature. Automatic range selection<br />
with 5 ranges. Case water resistant to IP67,<br />
connectors to IP65. Menu driven, with<br />
alphanumeric display for full-text prompting.<br />
Storage of time and date of last calibration for<br />
GLP. Memory for 150 readings of data, time and date, for Notepad results<br />
collection, or for AutoLog results collection with logging intervals between<br />
1min & 24h. Rechargeable NiMH battery gives up to 75h operation. Supplied<br />
with sensor (k=1), charger and solutions.<br />
TPS WP-88 Turbidity & Temperature<br />
Meter with 8m Cable<br />
TPS,WP-88 (6031) AU<br />
Portable hand-held turbidity and<br />
temperature meter for field or laboratory<br />
use. Sensor probe diameter 45mm,<br />
with 8m cable. Turbidity ranging 0.1 to<br />
200/2,000NTU ±1NTU with autoselection.<br />
Temperature compensation and sensor<br />
range 0 to 60ºC ±0.1ºC. Case water<br />
resistant to IP67, connectors to IP65, with detachable cable and sensor. Menu<br />
driven, with alphanumeric display. Auto storage of time, date and results of<br />
last calibration for GLP. RS232C interface, and memory for 150 readings<br />
of data, time and date, for Notepad results collection, or for AutoLog results<br />
collection with logging intervals between 1min and 24h. Rechargeable NiMH<br />
battery gives up to 50h operation. Supplied with download-software, charger<br />
and calibration solutions.<br />
Van Essen DI502 Mini-Diver Borehole<br />
Level Logger & Barometer 20m<br />
VAN,DI502 (6061) AU<br />
Mini-diver borehole level logger 20m, 1cm<br />
accuracy. Kit includes barometric logger for<br />
atmospheric pressure compensation. Will<br />
also log temperature. Temperature range<br />
-20 to 80ºC. Accuracy 0.1ºC. Size 22 x<br />
90mm. Stores 24,000 measurements per parameter. Stainless steel housing<br />
barometric (l/c) logger for compensation. 10 year battery life.
ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Light Meters, UVA/B/C<br />
Measurement<br />
Hioki 3423 Lux HiTester Digital<br />
Illuminance Meter<br />
HIO,3423 (5602) AU/MY<br />
Manual switching and autoranging.<br />
LCD display with 3½ digits (“1999”)<br />
for five measuring ranges to<br />
20/200/2,000lx in 1-count steps,<br />
20,000lx in 10-count steps and<br />
200,000lx in 100-count steps with accuracy ±4%. Response time in autorange<br />
mode 5s (2s in manual range mode). Autozero, hold and backlight function with<br />
delay for taking readings in low light. Input for AC power adaptor, connectingcable<br />
to allow separation of sensor unit and meter, and 200mVDC analogue<br />
output with cable. Battery powered.<br />
ILI 1400ABC Radiometer for UV<br />
Measurements<br />
ILI,1400ABC (5614) AU<br />
International Light model 1400<br />
radiometer with backlit LCD<br />
display, autozero and autoranging.<br />
Continuous reading with hold<br />
function, or integrated “dose”<br />
measurement up to 24h. Smart<br />
detectors with storage of units and detector-calibration data. Analogue recorder<br />
output. Mains adaptor or battery power. Supplied with three sensors: UV<br />
actinic hazard (UVC with B & A components matched to OSHA requirements),<br />
range 2.50e -7 to 2.50e -3 W/cm 2 eff. UVB + A (total “solar” radiation), range<br />
1.16e -7 to 4.07e -1 W/cm 2 . UVB, range 1.54e -6 to 1.54e -2 W/cm 2 .<br />
Minolta CL-200 Chroma Meter for Illuminance<br />
& Colour Measurement<br />
MIN,CL-200 (5610) AU<br />
Konica Minolta model CL-200 portable colour meter. LCD<br />
display for illuminance, tristimulus values, chromaticity,<br />
correlated colour temperature and colour difference.<br />
Illuminance range 0.1 to 99,990lx ±2%. Colour accuracy<br />
±0.002 [xy] or ±20°K [Tcp]. Fitted with RS232C interface.<br />
Battery powered, or AC adaptor.<br />
Topcon BM-9 Luminance Meter<br />
TOP,BM-9-2 (5611) AU<br />
Portable luminance meter with digital display. Field-of-view 5°, measurement<br />
acceptance angle 2°, with 10mm min spot diameter. Measuring distance<br />
0.35m to infinity. Silicon photodiode sensor with automatic or manual range<br />
selection. Measurement range 0.01 to 199,900cd/m 2 ±4% of reading. Built-in<br />
RS232C interface and analogue output. Battery powered.<br />
Topcon IM-2D Lux Meter NATA Certification<br />
TOP,IM-2D-NATA (5606) AU<br />
Digital illuminance meter with NATA certification.<br />
Measuring range from 0.1 to 19,999lx. Accuracy<br />
5%, ±1 digit. Autoranging with silicon sensor.<br />
Battery operated.<br />
Topcon IM-5 Lux Meter NATA Certification<br />
TOP,IM-5-NATA (5608) AU<br />
Digital wide-range illuminance meter with NATA certification. Measuring range<br />
0.01 to 199,000lx. Accuracy ±2% +1 digit. Autoranging with silicon sensor.<br />
Analogue output and RS232 interface. Battery operated.<br />
Yokogawa 51001 Lux Meter NATA Calibrated<br />
YEW,51001-NATA (5607) AU<br />
Digital illuminance meter with NATA certification. Measuring range from 0 to<br />
99.9/999/9,990/99,900/999,000lx . Accuracy 3,000lx<br />
6% ±1 digit. Autoranging with silicon sensor. Battery operated.<br />
76<br />
Weather Stations<br />
Environdata WeatherOne Wind Speed & Direction Logger<br />
ENV,DL20WSD (5886) AU<br />
Logging system for wind speed and direction. Tripod-mounted crossarm<br />
stand with 3-cup wind speed sensor range 0-75m/s and independent<br />
vane direction sensor. Sealed dual-channel logger with memory for 35,000<br />
readings with time and date, fitted with backup battery, rechargeable sealed<br />
main battery and solar panel for in-field recharge. <strong>Power</strong> supply for charging<br />
or operation from mains supply. “EasiAccess” software on CD for office or<br />
field connection via RS232C compatible computer (not included), for setup,<br />
download and real-time operation, with functions for tabular or graphical<br />
display.<br />
Environdata DL20WSD WeatherMaster<br />
2000 Weather Station<br />
ENV,WM20 (5888) AU<br />
Measures air temperature -15 to 50°C ±0.2, relative<br />
humidity 10 to 90%RH ±5%, rainfall 0.2mm resolution.<br />
Wind speed starting threshold 1kph. Wind direction<br />
resolution 6°C ±3%. One spare input channel.<br />
Capable of storing up to 3mths of data. Includes<br />
RS232 interface and software for download. Mounts<br />
on star-picket. Solar-rechargeable batteries.<br />
Environmental Flow Meters<br />
www.techrentals.com.au<br />
See also Flow Meters for Liquids & Gases on page 56-57<br />
Global FP101 Digital Water Velocity Meter<br />
GLO,FP101 (6147) AU<br />
Portable flow probe - current meter for water velocity<br />
measurements in streams, channels and partially filled pipes.<br />
Propeller sensor in 50mmØ housing, fitted to telescopic handle<br />
[1.8m] with gauging marks to 900mm depth. Digital LCD flow<br />
meter display for instantaneous liquid velocity and average,<br />
maximum, stopwatch or clock. Minimum depth about 50mm.<br />
Range 0.1 to 4.5m/s ±0.05.<br />
Hydrological Services Universal Current<br />
Meter OSS-B1<br />
HYS,OSSB1 (6145) AU<br />
Water current meter for measurement of flow<br />
velocity in rivers, streams, channels and open<br />
water. Robust streamlined stainless body fitted<br />
with high precision 100mmØ fan [flow range<br />
0.025 to 5m/s]. Set of stainless wading rods for depths to 3m. Rechargeable<br />
“Hydromate” ruggedised field computer with IP65 case. Storage of fan<br />
calibration formulae for direct readout of volume-flow. Touch screen entry for<br />
set up, input, storage and download. Supplied with PC download software<br />
and cable.<br />
Unidata 6526B-21LCD Open Channel Liquid Flow Logger with LCD<br />
Module<br />
UNI,6526B-21LCD (6141) AU<br />
Open channel flow logger with field LCD display module and 10m cable [2m<br />
depth rating]. Measurement and logging of flow-velocity [by Doppler], depth<br />
(by pressure) and temperature. Programmable for flow-channel profile [laptop<br />
PC required for in-situ programming via RS232C]. Operating temperature<br />
range 0 to 60°C. Velocity 21 to 5,000 mm/sec ±2%; depth 0 to 2,000 mm ±2%;<br />
temperature: -17 to 60°C ±0.1; log-interval 5 sec to 1 week; memory 120K.<br />
Programmable output to control devices such as water samplers. Detects<br />
and measures reverse flows. Charger and batteries supplied. Workhead<br />
dimensions 290 x 70 x 25mm.
www.techrentals.com.au ENVIRONMENT, OHS, CHEMICAL & LABORATORY<br />
Laboratory & Hand-held<br />
Microscopes<br />
Proscope SCA-12770 Video Microscope Kit<br />
PRO,SCA-12770 (5137) AU<br />
Hand-held USB video microscope complete kit. Includes 200X, 100X, 50X,<br />
1 to 10X interchangeable lenses, C Mount adaptor, stand and carry case.<br />
Connects to a PC via USB interface. Software allows snap shot still images<br />
and real time movie files to be saved. Resolution is 640 x 480 pixels.<br />
Balances & Scales below 8kg<br />
See also Weighing & Counting Scales over 8kg on page 61<br />
A&D HF-300G Mercury 300g Counting Scales<br />
AND,HF-300G (4439) AU<br />
Scales 310g, resolution 0.001, repeatability 0.001. Includes RS232 port.<br />
Includes counting software. Can be used as counting scales.<br />
A&D Mercury MX50 Moisture Balance<br />
AND,MX50 (4440) AU<br />
Maximum sample weight capacity 51g, weight resolution 0.001g, moisture content<br />
accuracy over 1g 0.10%, over 5g 0.02%. Halogen lamp used for heating,<br />
400watt max. Drying temperature 50 to 200ºC. Measurement programs 20 sets,<br />
measurement mode moisture content, wet or dry, dry content, ratio, weight.<br />
Heating mode standard, automatic, quick, timer, manual. Display large VFD,<br />
interface RS-232C, CD-ROM S/W supplied. Pan sample size diameter 85mm.<br />
Ohaus EXP4100 4100g Balance and Counting Scale<br />
OHA,EXP4100 (4432) AU<br />
Capacity 4.1kg. Display resolution 0.01g. Multi-unit display. Repeatability<br />
0.005g. RS232 interface.<br />
77<br />
Chemical & Analytical - General<br />
Hydramotion Viscolite 700 Portable Viscometer<br />
HYL,V700S-21 (6352) AU<br />
Advanced portable viscometer with stainless-steel probe. Operating range<br />
0.1 to 10,000mPaps (cps) with integral temperature correction -40 to 150ºC.<br />
Probe tip 21mmØ, immersion length 115mm (viscosity only) or 145mm<br />
(viscosity/temperature). Acetal polymer probe base for handheld or clamped<br />
operation, with coiled-cable connection to meter unit with 5 digit display.<br />
Battery powered.<br />
Laboratory Instruments,<br />
Spectroscopy<br />
X-Rite SP60 Portable Sphere Colour Spectrophotometer<br />
XRI,SP60 (6342) AU<br />
Portable spectrophotometer for surface colour measurements. Diffuse 8°<br />
[d/8] optical geometry with fixed 8mm aperture. Tungsten source for illuminant<br />
types C, D50, D65, D75, A, F2, F7, F11 & F12. Standard observers 2 & 10°.<br />
Blue-enhanced photodiode detectors with spectral range 400 to 700nm.<br />
Measures opacity and colour by chromatic, apparent or tristimulus calculation,<br />
with simultaneous included and excluded specular component, and spectrum<br />
at 10nm intervals. Storage of up to 2,000 samples with results download to<br />
serial printer or computer. Operation from internal rechargeable battery or AC<br />
adaptor.<br />
Have your OH&S Communications made easy<br />
with TR Bearcom Solutions!<br />
<br />
<br />
wide range of applications.<br />
<br />
<br />
– Good long distance line of sight coverage,<br />
e.g. open water<br />
<br />
way radios<br />
<br />
Accredited FM<br />
approved repairer<br />
The Motorola MTP850Ex TETRA ATEX and IEC Ex is the<br />
ideal two way radio for environments containing potentially<br />
explosive gas and dust.<br />
Features:<br />
<br />
<br />
<br />
<br />
<br />
bearcom<br />
no1 in radio solutions<br />
Check Out Our New<br />
Online Store<br />
www.trbearcom.com.au<br />
BS0322
OTHER PRODUCTS<br />
Security Equipment<br />
AVE Serial to Video Converter Including Video Mixer<br />
AVE,VSIPLUS (9218) AU<br />
Mixes serial data (text) with video signal, so that a picture includes this text.<br />
Use with a GPS (eg GA,ETREX) to add a location reference to a video or<br />
used with cash register RS232 output to record transactions on a security<br />
camera picture.<br />
4 Camera Surveillance Digital Stand-Alone Record System<br />
CAM,DVMR-4C (9255) AU<br />
4 day/night colour cameras with stand-alone digital video multiplex recorder,<br />
complete system with 15” colour LCD screen, 20m connection cables, power<br />
supplies and video to USB converter for down loading of data to PC.<br />
Detec DH50 Hand-held Metal Detector Kit of 4<br />
DET,DH-50-KIT4 (9208) AU<br />
Kit of 4 x hand held security metal detector. Simple to operate - no adjustment<br />
needed. Audible alarm.<br />
Detec Garrett CS5000 Walk Through Metal Detector<br />
GAR,CS5000 (9211) AU<br />
Detects all metals. Requires assembly on-site & set-up. Adjustable<br />
sensitivity.<br />
<br />
Counters<br />
Traffic Pro People Counter Event Logger<br />
TRA,RETAILPACK (9210) AU<br />
Counts the number of people passing a particular point. Used to check the<br />
success of in-store promotions, counting people entering sections of a store,<br />
etc. The unit operates from internal batteries and will store a year of data at a<br />
1h sample rate.<br />
NOTES<br />
78<br />
Prospecting Metal Detectors<br />
See also Underground Services Location on page 66-67<br />
www.techrentals.com.au<br />
Excaliber 1000 Underwater Metal Detector<br />
EXA,1000 (9204) AU<br />
MIN,EX-1000 MY<br />
Underwater metal detector with 10 inch search coil. Can be used effectively in<br />
or out of the water and is capable of going down to 60 meters depth. Features<br />
two operating modes; all metal and discriminate. In discriminate mode it will<br />
ignore most ferrous objects and still detect the valuable non-ferrous objects<br />
such as gold and silver. Rechargeable battery pack separated from the<br />
electronics cylinder allows easy access for recharging.<br />
Minelab Discriminating Metal Detector<br />
MIN,X-TERRA-705 (9205) AU<br />
Discriminating metal detector. Useful for locating lost<br />
coins rings etc. Preset operating modes depending<br />
upon what is required. Preset noise cancelling.
www.techrentals.com.au NOTES<br />
79
OUR STRENGTH LIES IN OUR STRONG TECHNICAL CAPACITY AND THE<br />
SYNERGIES BETWEEN OUR DIFFERENT BUSINESS UNITS.<br />
Test & Measurement<br />
TechRentals offers specialised test equipment<br />
product solutions for a wide range of industries.<br />
Products offered include power measurement and<br />
analysis, general electronic, environmental and<br />
OH&S, plus telecommunications. The leader in<br />
the industrial rental arena for more than 30 years,<br />
TechRentals also offers flexible purchasing options<br />
on selected product ranges.<br />
www.techrentals.com.au<br />
www.techrentals.com.my<br />
1800 632 652<br />
Audiovisual & Business Equipment<br />
TR Vidcom is raising standards in the dynamic<br />
computer and audio-visual industry, offering solutions<br />
for both short & long term equipment procurement and<br />
event management. TR Vidcom has superior product<br />
and industry knowledge, with a nation-wide service<br />
over 9 locations across Australia. We can provide<br />
all your computer and audio-visual requirements,<br />
with national support and timely delivery of your<br />
equipment. Our customers include major corporate<br />
companies around Australia and event managers<br />
around the nation. We can deliver, install and fully<br />
train your staff on your premises.<br />
www.trvidcom.com.au<br />
1800 843 266<br />
Mining Communications<br />
TR Minecom is an Australian technology company<br />
specialising in communications and safety systems<br />
for underground mining. Established in the 1980s,<br />
TR Minecom has built a solid reputation as a world<br />
leader in underground mining communication systems,<br />
in particular leaky feeder systems. TR Minecom<br />
offers a range of leaky feeder solutions designed to<br />
ensure high levels of safety and productivity.<br />
www.minecom.com<br />
1800 135 901<br />
80<br />
Satellite Communications<br />
TR Telecom is the region’s largest satellite telephony<br />
service provider, with a customer support team<br />
working from the Australian head office in Melbourne<br />
and offering comprehensive product sales and<br />
connections to the global Iridium network. TR Telecom<br />
is also proud to announce that it is an authorised<br />
reseller of NewSat communications. With coverage<br />
around Australia, New Zealand and surrounding<br />
island regions, you are able to stay connected with<br />
world class satellite solutions.<br />
www.trtelecom.com<br />
1300 550 014<br />
Calibration<br />
Utilising state-of-the-art technology, our experienced<br />
team delivers calibration and repair services to<br />
customers in defence, manufacturing, aviation and<br />
other high tech sectors. TR VMS calibration group<br />
has NATA accredited facilities in Australia, plus<br />
mobile calibration labs operating as needed to meet<br />
customers’ on-site demands.<br />
www.trvms.com.au<br />
1300 790 480<br />
Radio Communications<br />
TR Bearcom is the largest and most awarded<br />
two-way radio communications rental company in<br />
Australasia and a division of TR Pty Ltd. Whatever<br />
your business needs, TR Bearcom have the<br />
resources to develop a customised solution that is<br />
competitively priced and of the highest standard,<br />
using state-of-the-art two-way radio communications<br />
technology from the world’s leading manufacturers.<br />
www.trbearcom.com.au<br />
1800 222 327<br />
www.trbearcomrental.com.au<br />
1800 246 990
www.techrentals.com.au TECHRENTALS BUSINESS PARTNERS<br />
Acoustic Research<br />
Laboratories<br />
Anritsu<br />
EXFO<br />
Fluke<br />
Fluke Networks<br />
Gridsense<br />
JDSU<br />
Megger<br />
SebaKMT<br />
Testo<br />
TECHRENTALS ARE DISTRIBUTORS AND RESELLERS FOR:<br />
Anritsu<br />
JDSU<br />
Megger<br />
Gridsense<br />
TECHRENTALS - THE PERFECT SOLUTION!<br />
81<br />
Acoustic Research Laboratories<br />
SebaKMT<br />
<br />
Flir<br />
<br />
Aviation, HVAC, Defence, Electrical, Biomedical, Mechanical and Telco markets,<br />
access to our international<br />
partners giving you an even larger and deeper inventory to satisfy your needs.<br />
Remember that it is much more cost effective to Rent than to purchase outright as you are able to utilise<br />
capital expenditure in other parts of your business, however if you do need to eventually own the assets<br />
<br />
when you want them.
Australia<br />
1800 632 652<br />
www.techrentals.com.au<br />
Malaysia<br />
603 5632 1135<br />
www.techrentals.com.my<br />
TechRentals New Zealand*<br />
0800 832 473<br />
www.techrentals.co.nz<br />
*distributor of TechRentals Australia<br />
TR0523