copper or 4/O for aluminum or copper clad aluminum<br />

wire.<br />

The TV room at the rear of the house has exposed wire<br />

showing. The wire is to be traced and if found to be in<br />

service must be brought to code compliance by placing it<br />

in conduit or embedding or routing it through the wall<br />

interior. The security system wiring is to be removed and<br />

discarded. All wall holes or openings required to do this<br />

work must be repaired and that wall repainted.<br />

The existing bathroom exhaust fan needs to be replaced<br />

with a new fan. Dispose of the old fan unit.<br />

The kitchen light fixtures are to be replaced with new<br />

like type units.<br />

Cost of electrical work $<br />

4. Bathroom – The bathroom is to receive a new sink and faucets.<br />

Vanity is to be contractor’s grad 24” unit available at building<br />

supply outlets. A new mirror and light fixture are to be installed<br />

as well. Also, the tub is to be removed and replaced with a<br />

combination shower unit that has a connecting wall system to<br />

make a neat and workman like installation. Shower unit is to be<br />

made of commercially available plastic or fiberglass. There is to<br />

be new shower valves installed. Handicap accessible bars are<br />

also to be installed in shower area. Tub is standard 5’. Total<br />

bathroom size is 7’X5’. Floor covering will be sheet vinyl<br />

Cost of bathroom repairs $<br />

5. The roof framing, as seen from the attic has, has four “jack<br />

studs missing from the roof support structure. Install new 2x4<br />

jack supports bearing on the ceiling joists below and as plumb<br />

as can be achieved.<br />

Cost of roof framing $<br />

6. Contractor is to supply and install either a conventional heat<br />

pump or a split system using gas for a combustion fuel. The<br />

installation is to include all duct work, thermostat, registers and<br />

diffusers and wiring to make a completely functional system.<br />

Before making the choice of equipment or unit type, a review of<br />

the existing electrical system should be made as lack of<br />

capacity may determine which type of system is to be used. All<br />

6