HOME RENOVATION WORK SCOPE
HOME RENOVATION WORK SCOPE
HOME RENOVATION WORK SCOPE
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
copper or 4/O for aluminum or copper clad aluminum<br />
wire.<br />
The TV room at the rear of the house has exposed wire<br />
showing. The wire is to be traced and if found to be in<br />
service must be brought to code compliance by placing it<br />
in conduit or embedding or routing it through the wall<br />
interior. The security system wiring is to be removed and<br />
discarded. All wall holes or openings required to do this<br />
work must be repaired and that wall repainted.<br />
The existing bathroom exhaust fan needs to be replaced<br />
with a new fan. Dispose of the old fan unit.<br />
The kitchen light fixtures are to be replaced with new<br />
like type units.<br />
Cost of electrical work $<br />
4. Bathroom – The bathroom is to receive a new sink and faucets.<br />
Vanity is to be contractor’s grad 24” unit available at building<br />
supply outlets. A new mirror and light fixture are to be installed<br />
as well. Also, the tub is to be removed and replaced with a<br />
combination shower unit that has a connecting wall system to<br />
make a neat and workman like installation. Shower unit is to be<br />
made of commercially available plastic or fiberglass. There is to<br />
be new shower valves installed. Handicap accessible bars are<br />
also to be installed in shower area. Tub is standard 5’. Total<br />
bathroom size is 7’X5’. Floor covering will be sheet vinyl<br />
Cost of bathroom repairs $<br />
5. The roof framing, as seen from the attic has, has four “jack<br />
studs missing from the roof support structure. Install new 2x4<br />
jack supports bearing on the ceiling joists below and as plumb<br />
as can be achieved.<br />
Cost of roof framing $<br />
6. Contractor is to supply and install either a conventional heat<br />
pump or a split system using gas for a combustion fuel. The<br />
installation is to include all duct work, thermostat, registers and<br />
diffusers and wiring to make a completely functional system.<br />
Before making the choice of equipment or unit type, a review of<br />
the existing electrical system should be made as lack of<br />
capacity may determine which type of system is to be used. All<br />
6