ROTARY - SM18 INSTALLATION MANUAL.pdf - Atlantic Auto ...
ROTARY - SM18 INSTALLATION MANUAL.pdf - Atlantic Auto ...
ROTARY - SM18 INSTALLATION MANUAL.pdf - Atlantic Auto ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
NOTE: Two Different Drum Switches were used<br />
please select one of the two options below.<br />
NOTES:<br />
1. Unit not suitable for use in unusual conditions. Contact<br />
Rotary for moisture and dust environment duty unit.<br />
2. Control Box must be field mounted to power unit.<br />
3. Motor rotation is counter clockwise from top of motor.<br />
Fig. 21<br />
3 Phase<br />
Supply<br />
3 Phase<br />
Supply<br />
L1<br />
L2<br />
L3<br />
PE<br />
L1<br />
L2<br />
L3<br />
PE<br />
1<br />
5<br />
7<br />
1<br />
3<br />
5<br />
Three Phase Power Unit<br />
2<br />
6<br />
8<br />
DRUM<br />
SWITCH<br />
2<br />
4<br />
6<br />
DRUM<br />
SWITCH<br />
MOTOR OPERATING DATA TABLE - THREE PHASE<br />
LINE VOLTAGE RUNNING MOTOR VOLTAGE RANGE<br />
208-240V 50/60Hz. 197-253V<br />
400V 50Hz. 360-440V<br />
440-480V 50/60Hz. 396V-528V<br />
575V 60Hz. 518V-632V<br />
MOTOR<br />
(4) M5 x 45 PHMS, Plated<br />
MOTOR<br />
L3<br />
L2<br />
L1<br />
Steel Spacer<br />
Drum Switch<br />
And Cover<br />
T3<br />
T2<br />
T1<br />
Gasket<br />
11<br />
T9<br />
T8<br />
T7<br />
208-240V<br />
50/60Hz. 3Ø<br />
(4) M5 x 10 PHMS, Plated<br />
Capacitor Box To Power Unit<br />
T6<br />
T5<br />
T4<br />
FOR 3 Ø POWER<br />
UNITS: Attach Box using<br />
M5 x 10 PHMS, Plated<br />
Capacitor Box Attachment<br />
Option One<br />
L3<br />
L2<br />
L1<br />
Re-seal Between<br />
Box And Spacer<br />
With Silicone<br />
Sealer<br />
Capacitor Box Attachment<br />
Option Two<br />
T3<br />
T2<br />
T1<br />
T9 T6<br />
T8 T5<br />
T7 T4<br />
440-480V 50/60 Hz. 3Ø<br />
380-400V 50 Hz. 3Ø<br />
Capacitor<br />
Box<br />
V2<br />
U2<br />
W2<br />
W1<br />
V1<br />
U1<br />
575V 60 Hz. 3Ø<br />
T3<br />
T2<br />
T1