Thermo Top C - Giordano Benicchi
Thermo Top C - Giordano Benicchi
Thermo Top C - Giordano Benicchi
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Thermo</strong> <strong>Top</strong> C (TTC) 4 Installation<br />
4. Installation<br />
4.7 Fuel System<br />
4.7.1 General Description<br />
The pump, fuel line and fuel standpipe are integral to the systems reliability and must be installed<br />
according to these instructions to ensure proper heater operation.<br />
4.7.2 Fuel System Limitations<br />
CAUTION!<br />
If the fuel tank is higher than the fuel pump, the top of the tank may not be more than 20" above the<br />
pump.<br />
Fig. 404:<br />
Fuel System Limitations<br />
Maximum suction height (A) = 33"(1m)<br />
Maximum suction length (A + B) = 66"(2m)<br />
Maximum delivery length (C + D) = 196"(6m)<br />
Maximum delivery height (D) = 99"(3m)<br />
415