4 Installation <strong>Thermo</strong> <strong>Top</strong> C (TTC)<br />
4.7.5 Fuel Line<br />
Fuel line, couplers and clamps are provided in the installation kit and are required for proper<br />
operation.<br />
CAUTION!<br />
Fuel line must be secured every 12f (30 cm) and kept away from hot exhaust and moving parts<br />
(drive shaft, wheels, etc.<br />
NOTE:<br />
Use supplied hose clamps to secure all fuel line connections.<br />
The TTC has been equipped with fuel line meeting the required specifications for proper<br />
operation.<br />
The inside diameter of this fuel line is 0.08f (2.0 mm) and must not be substituted for fuel line of a<br />
larger diameter. Doing so will result in improper fuel delivery and the formation of air pockets in the<br />
fuel system which will interfere with heater operation.<br />
Fuel line connections must be made as shown in figure 407, fuel line connection.<br />
Fig. 407:<br />
Fuel Line Connection<br />
4.7.6 Fuel Filter<br />
The TTC heater may be equipped with a fuel filter.<br />
Fuel filters require changing at least annually and in cases of dirty fuel more often.<br />
NOTE:<br />
If heater is equipped with a fuel filter, change filter at least annually.<br />
418