Area of use<br />

For specialist solutions: emergency exit doors<br />

EN <strong>11</strong>25<br />

Area of use «emergency escape»<br />

Panic bolts in accordance with EN <strong>11</strong>25 are, on the other hand, used on<br />

emergency escape doors in public buildings where the visitors do not know<br />

the function of the emergency escape doors and must be able to use them in<br />

an emergency without instruction when necessary, e.g. in hospitals, schools<br />

or shopping centres.<br />

This is not valid for doors on apartments and doors on single and twofamily<br />

homes and terrace houses.<br />

Fittings:<br />

→ Escape side: rod handles or push rod across the entire width of the door.<br />

→ Outside: door handle, knob or blind plates, tested in accordance with DIN<br />

18273FS. It is not required that the free door handle end must face the<br />

door leaf!<br />

→ Double leaf doors (driving bar lock): rod handle<br />

DO numbers for GEOS fittings<br />

→ DO 20.26.01 for leaf doors (= wooden doors)<br />

Suitable for round rosettes and plate fittings<br />

→ DO 20.26.02 for metal frame doors<br />

Suitable for oval rosette fittings<br />

DO numbers for locks<br />

→ BKS<br />

EU Conformity certificate no.0432-BPR-0003<br />

Inspection ID DO 5.0/ DO 5.1/ DO 9.1/ DO 9.2/ DO 9.6<br />

→ BMH<br />

EU Conformity certificate no.0432-BPR-000041<br />

Inspection ID DO 5.3/ DO 6.16/ DO 6.8/ DO 9.2<br />

→ KABA<br />

Kabamatic lock Series 128 and Kabamatic elolegic lock Series 128,<br />

-in accordance with inspection certificate no. 12000<strong>11</strong>38.85 and no.<br />

12000<strong>11</strong>38.95, Inspection ID DO no. 6.17<br />

→ DORMA<br />

EU Conformity certificate no.0432-BPR-0005<br />

Inspection ID DO no. 20.4.01/DO 20.4.02<br />

outside EN <strong>11</strong>25 inside EN <strong>11</strong>25<br />

The release pressure is regulated with two<br />

different tests (A + B)<br />

1000 N<br />

80 N 220 N<br />

Test A<br />

Door without<br />

pre-load<br />

Test B<br />

Door with<br />

pre-load<br />

42 <strong>Grundmann</strong> | Fittings for Commercial and Public Sectors | Introduction