Area of use<br />
For specialist solutions: emergency exit doors<br />
EN <strong>11</strong>25<br />
Area of use «emergency escape»<br />
Panic bolts in accordance with EN <strong>11</strong>25 are, on the other hand, used on<br />
emergency escape doors in public buildings where the visitors do not know<br />
the function of the emergency escape doors and must be able to use them in<br />
an emergency without instruction when necessary, e.g. in hospitals, schools<br />
or shopping centres.<br />
This is not valid for doors on apartments and doors on single and twofamily<br />
homes and terrace houses.<br />
Fittings:<br />
→ Escape side: rod handles or push rod across the entire width of the door.<br />
→ Outside: door handle, knob or blind plates, tested in accordance with DIN<br />
18273FS. It is not required that the free door handle end must face the<br />
door leaf!<br />
→ Double leaf doors (driving bar lock): rod handle<br />
DO numbers for GEOS fittings<br />
→ DO 20.26.01 for leaf doors (= wooden doors)<br />
Suitable for round rosettes and plate fittings<br />
→ DO 20.26.02 for metal frame doors<br />
Suitable for oval rosette fittings<br />
DO numbers for locks<br />
→ BKS<br />
EU Conformity certificate no.0432-BPR-0003<br />
Inspection ID DO 5.0/ DO 5.1/ DO 9.1/ DO 9.2/ DO 9.6<br />
→ BMH<br />
EU Conformity certificate no.0432-BPR-000041<br />
Inspection ID DO 5.3/ DO 6.16/ DO 6.8/ DO 9.2<br />
→ KABA<br />
Kabamatic lock Series 128 and Kabamatic elolegic lock Series 128,<br />
-in accordance with inspection certificate no. 12000<strong>11</strong>38.85 and no.<br />
12000<strong>11</strong>38.95, Inspection ID DO no. 6.17<br />
→ DORMA<br />
EU Conformity certificate no.0432-BPR-0005<br />
Inspection ID DO no. 20.4.01/DO 20.4.02<br />
outside EN <strong>11</strong>25 inside EN <strong>11</strong>25<br />
The release pressure is regulated with two<br />
different tests (A + B)<br />
1000 N<br />
80 N 220 N<br />
Test A<br />
Door without<br />
pre-load<br />
Test B<br />
Door with<br />
pre-load<br />
42 <strong>Grundmann</strong> | Fittings for Commercial and Public Sectors | Introduction