HSK<br />

Modular control panels<br />

Application<br />

HOMA HSK are modular control panels<br />

useable for one or two pumps. They are<br />

are developed for waste water applications.<br />

HSK solve many different tasks<br />

based on a standardized control unit. Suitable<br />

for pumps 4 kW DOL to pumps<br />

22 kW star delta start.<br />

Advantages:<br />

same user interface for all classes<br />

flexible level measuring<br />

extensible<br />

In basis version these panels are<br />

equipped with a lot of standardized functions<br />

for most usefull requirements.<br />

HSK15<br />

HSK25<br />

Technical data:<br />

composite housing IP54<br />

voltage: 3x400V/N/PE; 50Hz<br />

rating: 4 kW DOL to 22 kW star delta<br />

evironment temperature: 0…50 0C<br />

dimensions: 215 x 200 (300 oder 400) x<br />

134mm DOL<br />

further technical description see instruction<br />

manual<br />

Basis equipment:<br />

Control functions:<br />

automatic change over<br />

peak load opration<br />

delay time<br />

on/off niveaus adjustable<br />

switch on delay<br />

short time start<br />

forced emptying<br />

phase fault monitoring<br />

sequence indicator<br />

languages D, GB, F, NL, I<br />

password<br />

Hardware:<br />

useable with explosion proof pumps<br />

overload relay or MCB<br />

contactor<br />

electronic pressure sensor<br />

two wire 4-20mA level sensor input<br />

inputs for float switches off, on 1, on 2,<br />

alarm (on 2 only by two pumps)<br />

alarm system (not battery backed) with<br />

buzzer<br />

dry contacts for alarm (P1 fault, P2<br />

fault, general alarm)<br />

inputs for thermocontacts of motorwinding<br />

LC-Display 2 line, 16 digits, 3 key button,<br />

LED opration, LED failure<br />

hour meter<br />

A-meter<br />

number of starts<br />

level indication<br />

Extensions:<br />

main switch<br />

moisture monitoring<br />

real time clock with event memory<br />

GSM MODEM<br />

RCB<br />

12V rechargeable battery block for battery<br />

backed alarm system<br />

internal heating<br />

manual – automatic – switch<br />

ex barriers for intrinsically safe circuits<br />

Pump Start Type Part-No. Motor protectionnominat<br />

current (A) switch relay<br />

Control box for 1 pump<br />

1,8 - 2,7 DOL HSK15-D027-BI 1970010 - up to 2,7A<br />

2,4 - 3,6 DOL HSK15-D036-BI 1970020 - up to 3,6A<br />

3,5 - 5,0 DOL HSK15-D050-BI 1970030 - up to 5,0A<br />

4,0 - 6,0 DOL HSK15-D060-BI 1970035 - up to 6,0A<br />

5,5 - 8,5 DOL HSK15-D085-BI 1970040 - up to 8,5A<br />

8,5 - 12,5 DOL HSK15-D125-BI 1970050 - up to 12,5A<br />

1,6 - 2,5 DOL HSK15-D025 1970110 up to 2,5A -<br />

2,4 - 4,0 DOL HSK15-D040 1970120 up to 4,0A -<br />

4,0 - 6,3 DOL HSK15-D063 1970130 up to 6,3A -<br />

6,3 - 10,0 DOL HSK15-D100 1970140 up to 10,0A -<br />

10,0 - 16,0 DOL HSK15-D160 1970150 up to 16,0A -<br />

6,3 - 10,0 Star-Delta HSK15-Y100 1970210 up to 10,0A -<br />

10,0 - 16,0 Star-Delta HSK15-Y160 1970220 up to 16,0A -<br />

16,0 - 20,0 Star-Delta HSK15-Y200 1970230 up to 20,0A -<br />

20,0 - 25,0 Star-Delta HSK15-Y250 1970240 up to 25,0A -<br />

25,0 - 32,0 Star-Delta HSK15-Y320 1970250 up to 32,0A -<br />

Control box for 2 pumps<br />

1,6 - 2,5 DOL HSK25-D025 1970310 up to 2,5A -<br />

2,4 - 4,0 DOL HSK25-D040 1970320 up to 4,0A -<br />

4,0 - 6,3 DOL HSK25-D063 1970330 up to 6,3A -<br />

6,3 - 10,0 DOL HSK25-D100 1970340 up to 10,0A -<br />

10,0 - 16,0 DOL HSK25-D160 1970350 up to 16,0A -<br />

6,3 - 10,0 Star-Delta HSK25-Y100 1970410 up to 10,0A -<br />

10,0 - 16,0 Star-Delta HSK25-Y160 1970420 up to 16,0A -<br />

16,0 - 20,0 Star-Delta HSK25-Y200 1970430 up to 20,0A -<br />

20,0 - 25,0 Star-Delta HSK25-Y250 1970440 up to 25,0A -<br />

25,0 - 32,0 Star-Delta HSK25-Y320 1970450 up to 32,0A -<br />

32,0 - 40,0 Star-Delta HSK25-Y400 1970460 up to 40,0A -<br />