2 - Proximedia
2 - Proximedia
2 - Proximedia
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
P U M P T E C H N O L O G Y<br />
Accessories for control boxes<br />
Controlling<br />
Description<br />
Part. No.<br />
Description<br />
Part. No.<br />
Main switch, with housing<br />
for control panels type:<br />
– BX15/PS15(all models) and<br />
BX25/PS25 up to 6A motor protection 1241400<br />
– BX25/PS25 above 6A motor protection 1241405<br />
Amperemter (per pump)<br />
– 0 – 6 A 1579005<br />
– 0 – 10 A 1579000<br />
– 0 – 15 A 1580000<br />
– 0 – 20 A 1580010<br />
– 0 – 60 A 1580020<br />
Voltmeter<br />
500 V 1580220<br />
Voltmeter-switch 1242510<br />
Hour meter (per pump) 1580410<br />
Impulse counter (per pump) 1580425<br />
Fault current protective switch (per pump)<br />
– 300 mA / 25 A 1561252<br />
– 300 mA / 40 A 1561253<br />
– 300 mA / 63 A 1561254<br />
for domestic application:<br />
– 30 mA / 25 A 1561250<br />
– 30 mA / 40 A 1561251<br />
ServCom diagnose unit for monitoring of operation data<br />
(hours, no. of starts, failures etc.)<br />
and adjustment of pump liquid levels in the tank 1964450<br />
Signal conditioning and protection<br />
Moisture monitoring relay<br />
RM4-LG01M,<br />
For moisture monitoring of oil chamber,<br />
voltage 230 V, 50/60Hz<br />
Length of sensor cable: 100m 1610995<br />
Seal probe, with straight screwed socket<br />
with 10m of cable for pump types:<br />
H…/ TP…/ GRP, T-Motor, Standard-Model 1585115<br />
Range MX, V, K,<br />
Standard-Model from P-Motor 1585120<br />
Moisture monitoring relay<br />
ER142<br />
For moisture monitoring of oil chamber,<br />
voltage 230 V, 50/60Hz<br />
Relais: 1 two way contact 1416510<br />
Seal probe, with straight screwed socket<br />
with 10m of cable for pump types:<br />
H…/ TP…/ GRP…/T-Motor, Ex-Model 1585130<br />
Range MX, V, K,<br />
Ex-Model from P-Motor 1585135<br />
Safety barriers<br />
for intrinsically safe measuring circuits,<br />
one barrier for one float switch,<br />
without auxiliary power,<br />
only use for BX, PS, C and CPS 1254423<br />
Signal conditioning instrument KR5/Ex<br />
for intrinsically safe measuring circuits.<br />
For one AS type float switch or<br />
two MB type float switches.<br />
230V/50Hz, relay with two way contact.<br />
Faults<br />
Description<br />
Part No.<br />
Warning signal light,<br />
for outdoor installation,<br />
flash frequency 1Hz<br />
12 V 1950012<br />
230 V 1950100<br />
Wireless basket 1950110<br />
Permanent beacon ,<br />
for outdoor installation, protection<br />
against vandalism<br />
permanent signal red 230V 1950241<br />
bulb 230V 1960006<br />
bulb 12V 1960007<br />
Signal horn,<br />
For indoor installation<br />
12 V 1260122<br />
230 V 1260125<br />
For outdoor installation<br />
12 V 1260121<br />
230 V 1260130<br />
1254425A<br />
Rechargeable battery 9V for main power independent alarm<br />
with connecting kit for control boxes BX, PS, C, CPS 1952214<br />
GSM-Alarm system, for up to 6 SMS alarm reports complete,<br />
including fault-report-unit, GSM-modem, antenna, all needed<br />
connection cables, software, voltage 24 V DC 19006004<br />
Power supply unit 230 V AC / 24 V DC<br />
With accumulator, for main power independent alarm,<br />
suitable for GSM alarm system 19006005<br />
Relay Card<br />
Control extensions with dry contacts for<br />
pump 1 fault, pump 2 fault and high water level<br />
for control boxes BX, PS, C, CPS 1470065<br />
Thermistorrelay EMT6-DB(230V)<br />
Signal conditioning instrument for<br />
temperature control of motor winding<br />
Voltage: 230V 50/60Hz 1560075<br />
12<br />
127