P U M P T E C H N O L O G Y<br />

Dimensions and main components<br />

Double-unit<br />

Tandem-double-unit<br />

DN50 PN10<br />

Pipe DN100<br />

Pipe DN100<br />

158<br />

100<br />

700<br />

158<br />

90°<br />

1<br />

3<br />

80<br />

2<br />

5<br />

14<br />

850<br />

438<br />

290<br />

160<br />

11<br />

7<br />

160<br />

230<br />

220 180<br />

455<br />

min. 600<br />

400<br />

300<br />

40<br />

2<br />

1<br />

5<br />

10<br />

3<br />

8<br />

9<br />

158<br />

700 100<br />

13<br />

DN80 PN10<br />

8 9 7<br />

3 5<br />

80<br />

12<br />

850<br />

158 438 100<br />

90°<br />

1 2<br />

5 3<br />

412<br />

11 11<br />

455 248 180 230<br />

160<br />

751<br />

min. 600<br />

400<br />

300<br />

40<br />

2<br />

1<br />

5 3<br />

10<br />

850<br />

438<br />

5<br />

3<br />

4<br />

179<br />

160<br />

438<br />

6<br />

3<br />

5<br />

11<br />

215<br />

438<br />

850<br />

11 6<br />

160<br />

290<br />

890<br />

179<br />

15 11<br />

160<br />

290<br />

360<br />

1800<br />

4<br />

160<br />

all dimensions in mm<br />

Inlet DN 150 horizontal<br />

Inlet DN 150 vertical, alternatively usable by<br />

KG-elbow (accessory) as 90° horizontal inlet<br />

Inlet DN 100 vertical<br />

Connection for pneumatic control box<br />

Air vent DN 70<br />

Cleaning cover<br />

Soft ball check valve DN 80<br />

Elastic union piece<br />

Flanged gate valve DN 80 (accessory)<br />

Connection for diaphragm pump BSP 1“<br />

Elastic union piece DN 150, 200 mm long<br />

Uplift safety<br />

Connection piece DN 100 (accessory)<br />

Connection DN 150<br />

Tandem-double-unit<br />

Blind flange<br />

Control box<br />

Electronic control box for control and<br />

monitoring of all important functions.<br />

Pneumatic level control with pressure<br />

operation. Auto-change over after each<br />

pump cycle. Operation of both pumps at<br />

high flow. In the event of failure automatic<br />

change over to the second pump. Motor<br />

protection with temperature<br />

control of the<br />

winding. Optical failure<br />

alarm. Accoustic<br />

alarm by buzzer. Volt<br />

free contact for<br />

remote signal. Control<br />

indication for direction of<br />

rotation.<br />

Connection for ServCom controller (see<br />

accessories) for:<br />

- Monitoring of operation hours, number<br />

of starts, maintenance interval, unnormal<br />

operating conditions.<br />

- Adjustment of pump operation level in<br />

the tank.<br />

Mains independent alarm by installing a 9V<br />

battery (see accessories).<br />

Accessories<br />

1 2<br />

Part description Dimension Part-No.<br />

1 Flanged gate valve DN 100 2216100<br />

with gasket and DN 150 2216150<br />

fixing bolts<br />

Flanged elastic DN 100 2159041<br />

union piece DN 150 2159541<br />

Hose band S 115/20 2311520<br />

GBS 168/30 2317520<br />

Flanged gate valve, DN 80 2216080<br />

with gasket and fixing bolts<br />

5<br />

4<br />

3<br />

1 2<br />

Part description Dimension Part-No.<br />

Flanged elastic DN 100 Equipment<br />

union piece<br />

supplied<br />

for discharge pipe DN 80 2159021<br />

Connection piece with DN 100 2155102<br />

flexible union piece<br />

Diaphragm pump BSP 1“ F 8502445<br />

Battery 9 V for mainsindependent<br />

alarm 1952214<br />

ServCom controller for monitoring of<br />

operation data and adjustment of the control<br />

levels in the tank.<br />

4<br />

3<br />

9<br />