2 - Proximedia
2 - Proximedia
2 - Proximedia
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
P U M P T E C H N O L O G Y<br />
Dimensions and main components<br />
Double-unit<br />
Tandem-double-unit<br />
DN50 PN10<br />
Pipe DN100<br />
Pipe DN100<br />
158<br />
100<br />
700<br />
158<br />
90°<br />
1<br />
3<br />
80<br />
2<br />
5<br />
14<br />
850<br />
438<br />
290<br />
160<br />
11<br />
7<br />
160<br />
230<br />
220 180<br />
455<br />
min. 600<br />
400<br />
300<br />
40<br />
2<br />
1<br />
5<br />
10<br />
3<br />
8<br />
9<br />
158<br />
700 100<br />
13<br />
DN80 PN10<br />
8 9 7<br />
3 5<br />
80<br />
12<br />
850<br />
158 438 100<br />
90°<br />
1 2<br />
5 3<br />
412<br />
11 11<br />
455 248 180 230<br />
160<br />
751<br />
min. 600<br />
400<br />
300<br />
40<br />
2<br />
1<br />
5 3<br />
10<br />
850<br />
438<br />
5<br />
3<br />
4<br />
179<br />
160<br />
438<br />
6<br />
3<br />
5<br />
11<br />
215<br />
438<br />
850<br />
11 6<br />
160<br />
290<br />
890<br />
179<br />
15 11<br />
160<br />
290<br />
360<br />
1800<br />
4<br />
160<br />
all dimensions in mm<br />
Inlet DN 150 horizontal<br />
Inlet DN 150 vertical, alternatively usable by<br />
KG-elbow (accessory) as 90° horizontal inlet<br />
Inlet DN 100 vertical<br />
Connection for pneumatic control box<br />
Air vent DN 70<br />
Cleaning cover<br />
Soft ball check valve DN 80<br />
Elastic union piece<br />
Flanged gate valve DN 80 (accessory)<br />
Connection for diaphragm pump BSP 1“<br />
Elastic union piece DN 150, 200 mm long<br />
Uplift safety<br />
Connection piece DN 100 (accessory)<br />
Connection DN 150<br />
Tandem-double-unit<br />
Blind flange<br />
Control box<br />
Electronic control box for control and<br />
monitoring of all important functions.<br />
Pneumatic level control with pressure<br />
operation. Auto-change over after each<br />
pump cycle. Operation of both pumps at<br />
high flow. In the event of failure automatic<br />
change over to the second pump. Motor<br />
protection with temperature<br />
control of the<br />
winding. Optical failure<br />
alarm. Accoustic<br />
alarm by buzzer. Volt<br />
free contact for<br />
remote signal. Control<br />
indication for direction of<br />
rotation.<br />
Connection for ServCom controller (see<br />
accessories) for:<br />
- Monitoring of operation hours, number<br />
of starts, maintenance interval, unnormal<br />
operating conditions.<br />
- Adjustment of pump operation level in<br />
the tank.<br />
Mains independent alarm by installing a 9V<br />
battery (see accessories).<br />
Accessories<br />
1 2<br />
Part description Dimension Part-No.<br />
1 Flanged gate valve DN 100 2216100<br />
with gasket and DN 150 2216150<br />
fixing bolts<br />
Flanged elastic DN 100 2159041<br />
union piece DN 150 2159541<br />
Hose band S 115/20 2311520<br />
GBS 168/30 2317520<br />
Flanged gate valve, DN 80 2216080<br />
with gasket and fixing bolts<br />
5<br />
4<br />
3<br />
1 2<br />
Part description Dimension Part-No.<br />
Flanged elastic DN 100 Equipment<br />
union piece<br />
supplied<br />
for discharge pipe DN 80 2159021<br />
Connection piece with DN 100 2155102<br />
flexible union piece<br />
Diaphragm pump BSP 1“ F 8502445<br />
Battery 9 V for mainsindependent<br />
alarm 1952214<br />
ServCom controller for monitoring of<br />
operation data and adjustment of the control<br />
levels in the tank.<br />
4<br />
3<br />
9<br />
99