WHEAT FLOUR FORTIFICATION WITH IRON - Idpas.org
WHEAT FLOUR FORTIFICATION WITH IRON - Idpas.org
WHEAT FLOUR FORTIFICATION WITH IRON - Idpas.org
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Appendix 3.10<br />
Wet digestion using sulfuric and nitric acids<br />
Used by the Institute of Nutrition and Food Technology, University of Chile<br />
I. Materials<br />
Volumetric flask, 1 L<br />
Volumetric flasks, 250 mL<br />
Volumetric flasks, 100 mL<br />
Volumetric flasks, 25 mL<br />
Beakers, 250 mL<br />
Volumetric pipettes, 100 mL, 500 mL, 200-1000 mL<br />
Graduated tubes<br />
Test tubes, 10 mL<br />
II. Equipment<br />
Analytical balance<br />
Hot-block digestion unit<br />
Wet ashing fume hood<br />
Kjeldahl flasks<br />
III. Reagents<br />
A. Iron Standard Solutions<br />
1. Stock standard solution. Fe 1000 mg/L. Dissolve 1.0 g Fe wire metal in 10 mL (65%) HNO3<br />
ultrapure. Dilute to 1000 mL with deonized water.<br />
2. Intermediate standard solution. Fe 10 mg/L. Dilute 10 mL stock standard solution to 1000 mL<br />
with deonized water.<br />
3. Working standard solution. Fe 1 µg/mL. Dilute 10 mL intermediate standard solution to 100 mL<br />
with deonized water.<br />
IV. Procedure<br />
Rinse all glassware with concentrated HCl diluted 1:1 with deonized water.<br />
1. Weigh 1 g homogenized sample (dry weight) into a 100 mL Kjeldahl flask.<br />
2. Add 6 mL of concentrated (97%) H2SO4 ultrapure and then 4 mL of (65%) HNO3 ultrapure to<br />
the sample, and predigest at room temperature for 12 hours.<br />
3. Place the flasks in a hot-block digestion apparatus and heat at 150°C for 4 hours.<br />
4. Remove the flask from the hot-block, and allow to cool at room temperature.<br />
5. After adequate cooling add 10 mL of 1 N HCl ultrapure, return the flasks to digestion rack and<br />
heat at 90°C until the samples are clear.<br />
6. Subsequently, remove the Kjeldahl flasks and transfer the sample digest to 50 mL volumetric<br />
flask (rinse the Kjeldahl flask five times with 5 mL of deonized water), and make up to volume with<br />
deonized water.<br />
V. Interpretation<br />
Iron is measured by atomic absorption spectrophotometric method using the following conditions:<br />
wavelength 248 nm, slit 0.2 nm, and flame air-C 2<br />
H 2<br />
(lean-blue).<br />
VI. Notes<br />
None<br />
VII. Reference<br />
Manuel Olivares, MD, Fernando Pizarro MT, Angelica Letelier MT, Eva Hertrampf, MD, and<br />
Tomas Walter, MD. Instituto de Nutricion y Tecnologia de los Alimentos, Universidad de Chile.<br />
37