Appendix 3.10<br />

Wet digestion using sulfuric and nitric acids<br />

Used by the Institute of Nutrition and Food Technology, University of Chile<br />

I. Materials<br />

Volumetric flask, 1 L<br />

Volumetric flasks, 250 mL<br />

Volumetric flasks, 100 mL<br />

Volumetric flasks, 25 mL<br />

Beakers, 250 mL<br />

Volumetric pipettes, 100 mL, 500 mL, 200-1000 mL<br />

Graduated tubes<br />

Test tubes, 10 mL<br />

II. Equipment<br />

Analytical balance<br />

Hot-block digestion unit<br />

Wet ashing fume hood<br />

Kjeldahl flasks<br />

III. Reagents<br />

A. Iron Standard Solutions<br />

1. Stock standard solution. Fe 1000 mg/L. Dissolve 1.0 g Fe wire metal in 10 mL (65%) HNO3<br />

ultrapure. Dilute to 1000 mL with deonized water.<br />

2. Intermediate standard solution. Fe 10 mg/L. Dilute 10 mL stock standard solution to 1000 mL<br />

with deonized water.<br />

3. Working standard solution. Fe 1 µg/mL. Dilute 10 mL intermediate standard solution to 100 mL<br />

with deonized water.<br />

IV. Procedure<br />

Rinse all glassware with concentrated HCl diluted 1:1 with deonized water.<br />

1. Weigh 1 g homogenized sample (dry weight) into a 100 mL Kjeldahl flask.<br />

2. Add 6 mL of concentrated (97%) H2SO4 ultrapure and then 4 mL of (65%) HNO3 ultrapure to<br />

the sample, and predigest at room temperature for 12 hours.<br />

3. Place the flasks in a hot-block digestion apparatus and heat at 150°C for 4 hours.<br />

4. Remove the flask from the hot-block, and allow to cool at room temperature.<br />

5. After adequate cooling add 10 mL of 1 N HCl ultrapure, return the flasks to digestion rack and<br />

heat at 90°C until the samples are clear.<br />

6. Subsequently, remove the Kjeldahl flasks and transfer the sample digest to 50 mL volumetric<br />

flask (rinse the Kjeldahl flask five times with 5 mL of deonized water), and make up to volume with<br />

deonized water.<br />

V. Interpretation<br />

Iron is measured by atomic absorption spectrophotometric method using the following conditions:<br />

wavelength 248 nm, slit 0.2 nm, and flame air-C 2<br />

H 2<br />

(lean-blue).<br />

VI. Notes<br />

None<br />

VII. Reference<br />

Manuel Olivares, MD, Fernando Pizarro MT, Angelica Letelier MT, Eva Hertrampf, MD, and<br />

Tomas Walter, MD. Instituto de Nutricion y Tecnologia de los Alimentos, Universidad de Chile.<br />

37