28.12.2013 Views

Design and Access Statement Site: Lyng Farm, NR20 4JE

NR20%204JE%20Design%20and%20Access%20Statement.pdf

NR20%204JE%20Design%20and%20Access%20Statement.pdf

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Design</strong> <strong>and</strong> <strong>Access</strong> <strong>Statement</strong><br />

<strong>Site</strong>: <strong>Lyng</strong> <strong>Farm</strong>, <strong>NR20</strong> <strong>4JE</strong><br />

Wind System Noise Emission<br />

The Evance R9000 wind system has been tested under certification conditions (reference<br />

Certificate Number MCS WT0039). The graph below gives the test data which in turn generates<br />

a Sound power level (dB) - based on LA,90 at 8m/s wind speed of 89.0dB <strong>and</strong> a noise slope of<br />

2.095dB per m/s wind speed.<br />

Immission Level against Background Noise Levels<br />

Taking the sound power emitted against wind speed <strong>and</strong> comparing it with typical background<br />

noise minimum levels for a very low noise, rural site provides a clear indication of the relative<br />

noise levels. However the background noise data used is taken at 10m height <strong>and</strong> the Evance<br />

system used is at 15m height. This means that the effective wind speed at 15m will be higher<br />

than that used at 10m for the background noise data by an amount equivalent to<br />

factor of 1.0845. Correcting the data provides a revised table of background noise against wind<br />