Petrology and Cu-Ni-PGE Mineralization of the Bovine Igneous ...
Petrology and Cu-Ni-PGE Mineralization of the Bovine Igneous ...
Petrology and Cu-Ni-PGE Mineralization of the Bovine Igneous ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
scanning electron microscope equipped with an energy dispersive spectrometer system (EDS).<br />
The EDS was used to acquire st<strong>and</strong>ardless analyses, which yielded semi-quantitative (~.5%<br />
error) major element compositions <strong>of</strong> <strong>the</strong> olivine <strong>and</strong> augite. Thirty one out <strong>of</strong> <strong>the</strong> 79 total<br />
polished thin sections collected from drill core 08BIC044 were selected for analysis.<br />
The samples chosen for mineral chemical analysis occur at regular intervals within each<br />
stratigraphic unit. Within each unit, samples were taken that best represented <strong>the</strong> unit <strong>and</strong> that<br />
contained <strong>the</strong> least altered olivine grains. The selected polished thin sections were coated with<br />
approximately 20 nanometers <strong>of</strong> carbon using a Denton vacuum carbon coater. Applying a<br />
conductive carbon coat to <strong>the</strong> sample surface allows for <strong>the</strong> dissipation <strong>of</strong> electrons, which will<br />
o<strong>the</strong>rwise build up on <strong>the</strong> surface <strong>and</strong> result in sample charging <strong>and</strong> beam deflection.<br />
The analyses were carried out in seven 3-4 hour sessions, which allowed for analysis <strong>of</strong><br />
multiple olivine <strong>and</strong> augite grains in three to five samples. An accelerating voltage <strong>of</strong> 15kv<br />
was used for <strong>the</strong> electron beam throughout each session. During each session, <strong>the</strong> EDS<br />
spectrum was calibrated to a thin piece <strong>of</strong> copper tape attached to <strong>the</strong> sample holder. After<br />
calibration, five to eight analyses were acquired <strong>of</strong> olivine <strong>and</strong> augite grains from three<br />
different areas on each thin section. Five were acquired in each <strong>of</strong> <strong>the</strong> three areas if only augite<br />
was present, whereas eight analyses were acquired if olivine was also present. Each analysis<br />
was carried out for a 20 second count time. The system was recalibrated on <strong>the</strong> copper tape<br />
between <strong>the</strong> analyses <strong>of</strong> each sample.<br />
2.5 Lithogeochemical Analysis<br />
Twenty seven samples from drill cores BIC01-01, 08BIC044, <strong>and</strong> one field sample<br />
from <strong>the</strong> marginal zone, were chosen for lithogeochemical analyses. One or more samples<br />
20