4.7. TIME MANAGEMENT FUNCTIONS 183<br />

If the alarm handler is active (TALM STA), lfttim returns the relative time until the alarm handler is<br />

scheduled to start. This value is within the range almtim ≥ lfttim ≥ 0 designated with tk sta alm.<br />

Since lfttim is decremented with each timer interrupt, lfttim = 0 means the alarm handler will start<br />

at the next timer interrupt. If the alarm handler is inactive (TALM STP), lfttim is indeterminate.<br />

If the alarm handler designated with tk ref alm in almid does not exist, error code E NOEXS is returned.<br />