Service Information SI-R-2002-013<br />
DD35 / XtenDD / HD<br />
2. Code Converter Problems<br />
After hardware modification of all types of controller boards (a new type of<br />
Manchester-Code-Converter IC chip has been implemented), sporadic LAN<br />
disconnections between mainframe and control panel can occur.<br />
Controllers of hardware indices shown in the following list can be affected by this<br />
phenomenon. How to find out the hardware index, please refer to chapter 6<br />
Type<br />
HW<br />
Index<br />
Designation<br />
Order No.<br />
Exchange part<br />
RY 2156 > 9 Mainframe Controller DD35 0 212 240 790<br />
RY 3156 > 9 Mainframe Controller XtenDD (SD and HD) 0 212 315 690<br />
RY 2374 > 4 Panel Controller RPS35-2 / -2S / -3 / -4/32 0 351 774 490<br />
RY 2600 > 2 RSE1 Controller 0 212 320 190<br />
A different way to check is identifying the type of assembled IC‘s on the PCBs.<br />
former type: SEEQ N08023<br />
new type: MicroLinear ML2652<br />
Location of IC Chips<br />
Board<br />
Type<br />
IC Location<br />
with<br />
SEEQ N08023<br />
IC Location<br />
with<br />
ML2652<br />
RY 2156 V155 V141<br />
RY 3156<br />
V141<br />
RY 2374 V42 V42<br />
RY 2600<br />
V64<br />
2 20.12.02