04.01.2014 Views

F:\测试数据\2010-12\宁波德普\三防灯TOP9118C-HF\3.gms - Tracon

F:\测试数据\2010-12\宁波德普\三防灯TOP9118C-HF\3.gms - Tracon

F:\测试数据\2010-12\宁波德普\三防灯TOP9118C-HF\3.gms - Tracon

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Zhejiang University Sensing instruments Co,.Ltd<br />

http://www.sensing.net.cn<br />

Email:service@sensing.net.com<br />

Tel:086-0571-85021543 Fax:086-0571-87977635<br />

Address:No.525 Xixi Road,Hangzhou,China<br />

宁 波 德 普 照 明 电 器 有 限 公 司 TOP9118C-HF<br />

LumCAT: TOP9118C-HF<br />

Luminaire: 三 防 灯<br />

Report No: SENSING20101229s001 Voltage(V): 220.000<br />

Test No: Current(A): 0.085<br />

LampCAT: : Power (W): 18.500<br />

Lamp flux(lm): 964.5 PF: 0.993<br />

Number of Lamps: 1<br />

Ballast type:<br />

Length(mm): 654<br />

Width(mm): 80<br />

Phm Type: C<br />

Height(mm): 35<br />

Photometric Results<br />

Lumens(lm): 834.60<br />

Efficiency(%): 86.54%<br />

Lumens(lm)/Power(W): 45.11<br />

Central intensity(cd): 158.479<br />

Maximum intensity(cd): 160.689<br />

Angle of maximum intensity: C=0.0 γ=32.0<br />

Beam Angle(50%lmax): [C0_180]Left=68.3 Right=67.8<br />

[C90_270]Left=N.A. Right=N.A.<br />

Field angle(10%lmax): [C0_180]Left=90.0 Right=90.0<br />

[C90_270]Left=90.0 Right=90.0<br />

Maximum s/h: C0_180=0.76 C90_270=0.62<br />

Up flux rate of lamp(%): 14.92%<br />

Down flux rate of lamp(%): 71.62%<br />

Up flux rate of LUM(%): 17.24%<br />

Down flux rate of LUM(%): 82.76%<br />

CIE Type : Semidirect lighting<br />

Output flux ratio in π solid angle : 50.770%<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 21.0 Humidity(%): 35.0% Distance(m): 13.04


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9118C-HF<br />

Light Distribution Curve [Unit: cd]<br />

Page: 2 Total:17<br />

±180°<br />

-90°<br />

32.14<br />

64.28<br />

96.41<br />

128.55<br />

160.69<br />

0°<br />

90°<br />

160.69<br />

128.55<br />

96.41<br />

64.28<br />

32.14<br />

0.00<br />

-180°<br />

-135° -90° -45° 0° 45° 90° 135° 180°<br />

C0(Max):<br />

C0/C180:<br />

C90/C270:<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 21.0 Humidity(%): 35.0% Distance(m): 13.04


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9118C-HF<br />

ISO illuminance diagram<br />

Page: 3 Total:17<br />

5.0d/h<br />

[Unit:lx] H=4.0m<br />

Imax:160.69cd<br />

4.0<br />

3.0<br />

2.0<br />

1.0<br />

0.0<br />

1.0<br />

2.0<br />

3.0<br />

4.0<br />

5.0d/h<br />

5.0d/h<br />

4.0 3.0 2.0 1.0 0.0 1.0 2.0 3.0 4.0 5.0d/h<br />

(10%Emax) 0.9904938<br />

(20%Emax) 1.980981<br />

(30%Emax) 2.971475<br />

(40%Emax) 3.961969<br />

(50%Emax) 4.952463<br />

(60%Emax) 5.94295<br />

(70%Emax) 6.933437<br />

(80%Emax) 7.923937<br />

(90%Emax) 8.914437<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 21.0 Humidity(%): 35.0% Distance(m): 13.04


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9118C-HF<br />

Luminance Limitting Curve(luminous side)<br />

Page: 4 Total:17<br />

Luminance Table<br />

γ 45 50 55 60 65 70 75 80 85<br />

C0 2926 3048 3205 3310 3416 3504 3634 3952 4512<br />

C90 2587 2457 2258 2052 1773 1417 1057 790 648<br />

Glare Table<br />

Glare Quality Service Values Illuminance(lx)<br />

1.15 A 2000 1000 500


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9118C-HF<br />

Budgetary Estimate Table<br />

Page: 5 Total:17<br />

Budgetary Estimate Tab<br />

40 Lamp Flux 964.5 lm<br />

Maint Co 0.8/0.8<br />

30 Ave Illu 100.0 lx<br />

Plane H 0.0 m<br />

Place C W F<br />

20 Refl1<br />

0.7 0.5 0.2<br />

Refl2<br />

0.5 0.3 0.2<br />

[N]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

6m<br />

2<br />

2m<br />

1<br />

1 2 3 4 5 6 7 8 9 10 20<br />

S[m2]<br />

40 60 80 100 200 400 600 800<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 21.0 Humidity(%): 35.0% Distance(m): 13.04


Zhejiang University Sensing instruments Co,.Ltd<br />

http://www.sensing.net.cn<br />

Email:Email:service@sensing.net.com<br />

Tel:086-0571-85021543 Fax:086-0571-87977635<br />

Address:No.525 Xixi Road,Hangzhou,China<br />

宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

LumCAT: 三 防 灯<br />

Luminaire: TOP9136C-HF<br />

Report No: SENSING20110112S002 Voltage(V): 220.000<br />

Test No: Current(A): 0.156<br />

LampCAT: : TOP T8 36W Power (W): 34.100<br />

Lamp flux(lm): 2011.0 PF: 0.990<br />

Number of Lamps: 1<br />

Ballast type:<br />

Length(mm): 1250<br />

Width(mm): 90<br />

Phm Type: C<br />

Height(mm): 45<br />

Photometric Results<br />

Lumens(lm): 1648.14<br />

Efficiency(%): 81.96%<br />

Lumens(lm)/Power(W): 48.33<br />

Central intensity(cd): 323.645<br />

Maximum intensity(cd): 332.480<br />

Angle of maximum intensity: C=0.0 γ=30.0<br />

Beam Angle(50%lmax): [C0_180]Left=62.3 Right=62.8<br />

[C90_270]Left=N.A. Right=N.A.<br />

Field angle(10%lmax): [C0_180]Left=90.0 Right=90.0<br />

[C90_270]Left=90.0 Right=90.0<br />

Maximum s/h: C0_180=0.76 C90_270=0.62<br />

Up flux rate of lamp(%): 12.62%<br />

Down flux rate of lamp(%): 69.34%<br />

Up flux rate of LUM(%): 15.40%<br />

Down flux rate of LUM(%): 84.60%<br />

CIE Type : Semidirect lighting<br />

Output flux ratio in π solid angle : 52.023%<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 48.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Light Distribution Curve [Unit: cd]<br />

Page: 2 Total:9<br />

±180°<br />

-90°<br />

66.50<br />

132.99<br />

199.49<br />

265.98<br />

332.48<br />

0°<br />

90°<br />

332.48<br />

265.98<br />

199.49<br />

132.99<br />

66.50<br />

0.00<br />

-180°<br />

-135° -90° -45° 0° 45° 90° 135° 180°<br />

C0(Max):<br />

C0/C180:<br />

C90/C270:<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 48.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

ISO illuminance diagram<br />

Page: 3 Total:9<br />

5.0d/h<br />

[Unit:lx] H=4.0m<br />

Imax:332.48cd<br />

4.0<br />

3.0<br />

2.0<br />

1.0<br />

0.0<br />

1.0<br />

2.0<br />

3.0<br />

4.0<br />

5.0d/h<br />

5.0d/h<br />

4.0 3.0 2.0 1.0 0.0 1.0 2.0 3.0 4.0 5.0d/h<br />

(10%Emax) 2.033569<br />

(20%Emax) 4.067138<br />

(30%Emax) 6.100706<br />

(40%Emax) 8.13425<br />

(50%Emax) 10.16781<br />

(60%Emax) 12.20144<br />

(70%Emax) 14.235<br />

(80%Emax) 16.26856<br />

(90%Emax) 18.30213<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 48.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Luminance Limitting Curve(luminous side)<br />

Page: 4 Total:9<br />

Luminance Table<br />

γ 45 50 55 60 65 70 75 80 85<br />

C0 3112 3169 3250 3282 3313 3356 3518 3808 4122<br />

C90 3148 2989 2813 2597 2283 1877 1389 978 713<br />

Glare Table<br />

Glare Quality Service Values Illuminance(lx)<br />

1.15 A 2000 1000 500


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Budgetary Estimate Table<br />

Page: 5 Total:9<br />

Budgetary Estimate Tab<br />

40 Lamp Flux 2011.0 lm<br />

Maint Co 0.8/0.8<br />

30 Ave Illu 100.0 lx<br />

Plane H 0.0 m<br />

Place C W F<br />

20<br />

Refl1<br />

0.7 0.5 0.2<br />

Refl2<br />

0.5 0.3 0.2<br />

[N]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

6m<br />

1<br />

2m<br />

1 2 3 4 5 6 7 8 9 10 20<br />

S[m2]<br />

40 60 80 100 200 400 600 800<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 48.0% Distance(m): 12.45


Zhejiang University Sensing instruments Co,.Ltd<br />

http://www.sensing.net.cn<br />

Email:Email:service@sensing.net.com<br />

Tel:086-0571-85021543 Fax:086-0571-87977635<br />

Address:No.525 Xixi Road,Hangzhou,China<br />

宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

LumCAT: 三 防 灯<br />

Luminaire: TOP9158C-HF<br />

Report No: SENSING20110112S001 Voltage(V): 220.000<br />

Test No: Current(A): 0.264<br />

LampCAT: : TOP T8 58W Power (W): 57.800<br />

Lamp flux(lm): 3585.0 PF: 0.994<br />

Number of Lamps: 1<br />

Ballast type:<br />

Length(mm): 1540<br />

Width(mm): 90<br />

Phm Type: C<br />

Height(mm): 45<br />

Photometric Results<br />

Lumens(lm): 2573.15<br />

Efficiency(%): 71.78%<br />

Lumens(lm)/Power(W): 44.52<br />

Central intensity(cd): 498.953<br />

Maximum intensity(cd): 523.908<br />

Angle of maximum intensity: C=180.0 γ=10.0<br />

Beam Angle(50%lmax): [C0_180]Left=52.5 Right=52.2<br />

[C90_270]Left=N.A. Right=N.A.<br />

Field angle(10%lmax): [C0_180]Left=81.6 Right=79.9<br />

[C90_270]Left=90.0 Right=90.0<br />

Maximum s/h: C0_180=0.73 C90_270=0.62<br />

Up flux rate of lamp(%): 11.03%<br />

Down flux rate of lamp(%): 60.75%<br />

Up flux rate of LUM(%): 15.36%<br />

Down flux rate of LUM(%): 84.64%<br />

CIE Type : Semidirect lighting<br />

Output flux ratio in π solid angle : 51.318%<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 45.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Light Distribution Curve [Unit: cd]<br />

Page: 2 Total:9<br />

±180°<br />

-90°<br />

104.78<br />

209.56<br />

314.35<br />

419.13<br />

523.91<br />

0°<br />

90°<br />

523.91<br />

419.13<br />

314.35<br />

209.56<br />

104.78<br />

0.00<br />

-180°<br />

-135° -90° -45° 0° 45° 90° 135° 180°<br />

C180(Max):<br />

C0/C180:<br />

C90/C270:<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 45.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

ISO illuminance diagram<br />

Page: 3 Total:9<br />

5.0d/h<br />

[Unit:lx] H=4.0m<br />

Imax:523.91cd<br />

4.0<br />

3.0<br />

2.0<br />

1.0<br />

0.0<br />

1.0<br />

2.0<br />

3.0<br />

4.0<br />

5.0d/h<br />

5.0d/h<br />

4.0 3.0 2.0 1.0 0.0 1.0 2.0 3.0 4.0 5.0d/h<br />

(10%Emax) 3.214406<br />

(20%Emax) 6.428813<br />

(30%Emax) 9.64325<br />

(40%Emax) 12.85763<br />

(50%Emax) 16.07206<br />

(60%Emax) 19.28644<br />

(70%Emax) 22.50088<br />

(80%Emax) 25.71525<br />

(90%Emax) 28.92969<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 45.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Luminance Limitting Curve(luminous side)<br />

Page: 4 Total:9<br />

Luminance Table<br />

γ 45 50 55 60 65 70 75 80 85<br />

C0 3888 3980 4048 4121 4238 4480 4811 5067 5302<br />

C90 3922 3725 3477 3128 2680 2172 1681 1199 871<br />

Glare Table<br />

Glare Quality Service Values Illuminance(lx)<br />

1.15 A 2000 1000 500


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Budgetary Estimate Table<br />

Page: 5 Total:9<br />

Budgetary Estimate Tab<br />

40 Lamp Flux 3585.0 lm<br />

Maint Co 0.8/0.8<br />

30 Ave Illu 100.0 lx<br />

Plane H 0.0 m<br />

Place C W F<br />

20<br />

Refl1<br />

0.7 0.5 0.2<br />

Refl2<br />

0.5 0.3 0.2<br />

[N]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

6m<br />

2m<br />

1 2 3 4 5 6 7 8 9 10 20<br />

S[m2]<br />

40 60 80 100 200 400 600 800<br />

Equipment: GMS2000 Date: 2011-1-12 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 45.0% Distance(m): 12.45


Zhejiang University Sensing instruments Co,.Ltd<br />

http://www.sensing.net.cn<br />

Email:service@sensing.net.com<br />

Tel:086-0571-85021543 Fax:086-0571-87977635<br />

Address:No.525 Xixi Road,Hangzhou,China<br />

宁 波 德 普 照 明 电 器 有 限 公 司 TOP9218C-HF<br />

LumCAT: TOP9218C-HF<br />

Luminaire: 三 防 灯<br />

Report No: SENSING20101229s002 Voltage(V): 220.000<br />

Test No: Current(A): 0.151<br />

LampCAT: : Power (W): 32.800<br />

Lamp flux(lm): 958.4 PF: 0.983<br />

Number of Lamps: 2<br />

Ballast type:<br />

Length(mm): 654<br />

Width(mm): 80<br />

Phm Type: C<br />

Height(mm): 35<br />

Photometric Results<br />

Lumens(lm): 1410.67<br />

Efficiency(%): 73.59%<br />

Lumens(lm)/Power(W): 43.01<br />

Central intensity(cd): 317.666<br />

Maximum intensity(cd): 321.379<br />

Angle of maximum intensity: C=75.0 γ=0.0<br />

Beam Angle(50%lmax): [C0_180]Left=55.3 Right=51.9<br />

[C90_270]Left=81.3 Right=80.8<br />

Field angle(10%lmax): [C0_180]Left=78.7 Right=75.3<br />

[C90_270]Left=90.0 Right=90.0<br />

Maximum s/h: C0_180=0.75 C90_270=0.63<br />

Up flux rate of lamp(%): 9.09%<br />

Down flux rate of lamp(%): 64.50%<br />

Up flux rate of LUM(%): 12.35%<br />

Down flux rate of LUM(%): 87.65%<br />

CIE Type : Semidirect lighting<br />

Output flux ratio in π solid angle : 58.632%<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 22.0 Humidity(%): 35.0% Distance(m): 13.04


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9218C-HF<br />

Light Distribution Curve [Unit: cd]<br />

Page: 2 Total:17<br />

±180°<br />

-90°<br />

64.28<br />

128.55<br />

192.83<br />

257.10<br />

321.38<br />

0°<br />

90°<br />

321.38<br />

257.10<br />

192.83<br />

128.55<br />

64.28<br />

0.00<br />

-180°<br />

-135° -90° -45° 0° 45° 90° 135° 180°<br />

C75(Max):<br />

C0/C180:<br />

C90/C270:<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 22.0 Humidity(%): 35.0% Distance(m): 13.04


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9218C-HF<br />

ISO illuminance diagram<br />

Page: 3 Total:17<br />

5.0d/h<br />

[Unit:lx] H=4.0m<br />

Imax:321.38cd<br />

4.0<br />

3.0<br />

2.0<br />

1.0<br />

0.0<br />

1.0<br />

2.0<br />

3.0<br />

4.0<br />

5.0d/h<br />

5.0d/h<br />

4.0 3.0 2.0 1.0 0.0 1.0 2.0 3.0 4.0 5.0d/h<br />

(10%Emax) 1.985412<br />

(20%Emax) 3.970825<br />

(30%Emax) 5.956231<br />

(40%Emax) 7.941625<br />

(50%Emax) 9.927062<br />

(60%Emax) 11.91244<br />

(70%Emax) 13.89787<br />

(80%Emax) 15.88331<br />

(90%Emax) 17.86869<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 22.0 Humidity(%): 35.0% Distance(m): 13.04


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9218C-HF<br />

Luminance Limitting Curve(luminous side)<br />

Page: 4 Total:17<br />

Luminance Table<br />

γ 45 50 55 60 65 70 75 80 85<br />

C0 5554 5387 5423 5543 5666 5731 5652 5215 5270<br />

C90 5357 5157 4869 4515 4091 3546 2836 1924 1458<br />

Glare Table<br />

Glare Quality Service Values Illuminance(lx)<br />

1.15 A 2000 1000 500


宁 波 德 普 照 明 电 器 有 限 公 司 TOP9218C-HF<br />

Budgetary Estimate Table<br />

Page: 5 Total:17<br />

Budgetary Estimate Tab<br />

40 Lamp Flux 1916.8 lm<br />

Maint Co 0.8/0.8<br />

30 Ave Illu 100.0 lx<br />

Plane H 0.0 m<br />

Place C W F<br />

20 Refl1<br />

0.7 0.5 0.2<br />

Refl2<br />

0.5 0.3 0.2<br />

[N]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

6m<br />

1<br />

2m<br />

1 2 3 4 5 6 7 8 9 10 20<br />

S[m2]<br />

40 60 80 100 200 400 600 800<br />

Equipment: GMS-2000 Date: 24/12/2010 Operator: Zhengliangliang<br />

Temperature(°C): 22.0 Humidity(%): 35.0% Distance(m): 13.04


Zhejiang University Sensing instruments Co,.Ltd<br />

http://www.sensing.net.cn<br />

Email:Email:service@sensing.net.com<br />

Tel:086-0571-85021543 Fax:086-0571-87977635<br />

Address:No.525 Xixi Road,Hangzhou,China<br />

宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

LumCAT: 三 防 灯<br />

Luminaire: TOP9236C-HF<br />

Report No: SENSING20110111S001 Voltage(V): 220.000<br />

Test No: Current(A): 0.305<br />

LampCAT: : TOP 136 T8 Power (W): 67.600<br />

Lamp flux(lm): 1986.2 PF: 0.996<br />

Number of Lamps: 2<br />

Ballast type:<br />

Length(mm): 1240<br />

Width(mm): 125<br />

Phm Type: C<br />

Height(mm): 47<br />

Photometric Results<br />

Lumens(lm): 3221.39<br />

Efficiency(%): 81.09%<br />

Lumens(lm)/Power(W): 47.65<br />

Central intensity(cd): 744.322<br />

Maximum intensity(cd): 759.822<br />

Angle of maximum intensity: C=180.0 γ=25.0<br />

Beam Angle(50%lmax): [C0_180]Left=57.2 Right=58.3<br />

[C90_270]Left=56.0 Right=106.2<br />

Field angle(10%lmax): [C0_180]Left=90.0 Right=90.0<br />

[C90_270]Left=90.0 Right=90.0<br />

Maximum s/h: C0_180=0.75 C90_270=0.62<br />

Up flux rate of lamp(%): 8.68%<br />

Down flux rate of lamp(%): 72.41%<br />

Up flux rate of LUM(%): 10.71%<br />

Down flux rate of LUM(%): 89.29%<br />

CIE Type : Semidirect lighting<br />

Output flux ratio in π solid angle : 60.143%<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Light Distribution Curve [Unit: cd]<br />

Page: 2 Total:9<br />

±180°<br />

-90°<br />

151.96<br />

303.93<br />

455.89<br />

607.86<br />

759.82<br />

0°<br />

90°<br />

759.82<br />

607.86<br />

455.89<br />

303.93<br />

151.96<br />

0.00<br />

-180°<br />

-135° -90° -45° 0° 45° 90° 135° 180°<br />

C180(Max):<br />

C0/C180:<br />

C90/C270:<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

ISO illuminance diagram<br />

Page: 3 Total:9<br />

2.2d/h<br />

[Unit:lx] H=4.0m<br />

Imax:759.82cd<br />

1.8<br />

1.3<br />

0.9<br />

0.4<br />

0.0<br />

0.4<br />

0.9<br />

1.3<br />

1.8<br />

2.2d/h<br />

2.2d/h<br />

1.8 1.3 0.9 0.4 0.0 0.4 0.9 1.3 1.8 2.2d/h<br />

(10%Emax) 4.652012<br />

(20%Emax) 9.304<br />

(30%Emax) 13.95606<br />

(40%Emax) 18.60806<br />

(50%Emax) 23.26006<br />

(60%Emax) 27.91206<br />

(70%Emax) 32.56406<br />

(80%Emax) 37.21606<br />

(90%Emax) 41.86813<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Luminance Limitting Curve(luminous side)<br />

Page: 4 Total:9<br />

Luminance Table<br />

γ 45 50 55 60 65 70 75 80 85<br />

C0 5671 5562 5474 5493 5426 5324 5187 4993 4980<br />

C90 5236 5012 4714 4305 3858 3343 2668 1750 1243<br />

Glare Table<br />

Glare Quality Service Values Illuminance(lx)<br />

1.15 A 2000 1000 500


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Budgetary Estimate Table<br />

Page: 5 Total:9<br />

Budgetary Estimate Tab<br />

40 Lamp Flux 3972.4 lm<br />

Maint Co 0.8/0.8<br />

30 Ave Illu 100.0 lx<br />

Plane H 0.0 m<br />

Place C W F<br />

20<br />

Refl1<br />

0.7 0.5 0.2<br />

Refl2<br />

0.5 0.3 0.2<br />

[N]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

6m<br />

2m<br />

1 2 3 4 5 6 7 8 9 10 20<br />

S[m2]<br />

40 60 80 100 200 400 600 800<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


Zhejiang University Sensing instruments Co,.Ltd<br />

http://www.sensing.net.cn<br />

Email:Email:service@sensing.net.com<br />

Tel:086-0571-85021543 Fax:086-0571-87977635<br />

Address:No.525 Xixi Road,Hangzhou,China<br />

宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

LumCAT: 三 防 灯<br />

Luminaire: TOP9258C-HF<br />

Report No: SENSING20110111S002 Voltage(V): 220.000<br />

Test No: Current(A): 0.438<br />

LampCAT: : TOP T8 58W Power (W): 96.200<br />

Lamp flux(lm): 3150.0 PF: 0.998<br />

Number of Lamps: 2<br />

Ballast type:<br />

Length(mm): 1540<br />

Width(mm): 125<br />

Phm Type: C<br />

Height(mm): 45<br />

Photometric Results<br />

Lumens(lm): 4485.52<br />

Efficiency(%): 71.20%<br />

Lumens(lm)/Power(W): 46.63<br />

Central intensity(cd): 1022.397<br />

Maximum intensity(cd): 1073.392<br />

Angle of maximum intensity: C=0.0 γ=20.0<br />

Beam Angle(50%lmax): [C0_180]Left=55.3 Right=55.4<br />

[C90_270]Left=99.2 Right=61.7<br />

Field angle(10%lmax): [C0_180]Left=86.2 Right=87.1<br />

[C90_270]Left=90.0 Right=90.0<br />

Maximum s/h: C0_180=0.74 C90_270=0.62<br />

Up flux rate of lamp(%): 8.66%<br />

Down flux rate of lamp(%): 62.54%<br />

Up flux rate of LUM(%): 12.16%<br />

Down flux rate of LUM(%): 87.84%<br />

CIE Type : Semidirect lighting<br />

Output flux ratio in π solid angle : 59.088%<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Light Distribution Curve [Unit: cd]<br />

Page: 2 Total:9<br />

±180°<br />

-90°<br />

214.68<br />

429.36<br />

644.04<br />

858.71<br />

1073.39<br />

0°<br />

90°<br />

1073.39<br />

858.71<br />

644.04<br />

429.36<br />

214.68<br />

0.00<br />

-180°<br />

-135° -90° -45° 0° 45° 90° 135° 180°<br />

C0(Max):<br />

C0/C180:<br />

C90/C270:<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

ISO illuminance diagram<br />

Page: 3 Total:9<br />

2.2d/h<br />

[Unit:lx] H=4.0m<br />

Imax:1073.39cd<br />

1.7<br />

1.3<br />

0.9<br />

0.4<br />

0.0<br />

0.4<br />

0.9<br />

1.3<br />

1.7<br />

2.2d/h<br />

2.2d/h<br />

1.7 1.3 0.9 0.4 0.0 0.4 0.9 1.3 1.7 2.2d/h<br />

(10%Emax) 6.555125<br />

(20%Emax) 13.11031<br />

(30%Emax) 19.66544<br />

(40%Emax) 26.22056<br />

(50%Emax) 32.77569<br />

(60%Emax) 39.33088<br />

(70%Emax) 45.886<br />

(80%Emax) 52.44112<br />

(90%Emax) 58.99631<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Luminance Limitting Curve(luminous side)<br />

Page: 4 Total:9<br />

Luminance Table<br />

γ 45 50 55 60 65 70 75 80 85<br />

C0 6068 5828 5928 6220 6336 6307 6205 5962 5905<br />

C90 5951 5687 5407 4999 4536 3873 2904 2018 1436<br />

Glare Table<br />

Glare Quality Service Values Illuminance(lx)<br />

1.15 A 2000 1000 500


宁 波 德 普 照 明 电 器 有 限 公 司 三 防 灯<br />

Budgetary Estimate Table<br />

Page: 5 Total:9<br />

Budgetary Estimate Tab<br />

40 Lamp Flux 6300.0 lm<br />

Maint Co 0.8/0.8<br />

30 Ave Illu 100.0 lx<br />

Plane H 0.0 m<br />

Place C W F<br />

20<br />

Refl1<br />

0.7 0.5 0.2<br />

Refl2<br />

0.5 0.3 0.2<br />

[N]<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

6m<br />

2m<br />

1 2 3 4 5 6 7 8 9 10 20<br />

S[m2]<br />

40 60 80 100 200 400 600 800<br />

Equipment: GMS2000 Date: 2011-1-11 Operator: yinxiaoming<br />

Temperature(°C): 19.0 Humidity(%): 42.0% Distance(m): 12.45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!