SELF-CONTAINED VERTICAL<br />

AIR-TO-AIR COMPACT UNITS<br />

ACVA<br />

ACVBA<br />

Cooling only<br />

Heat pump<br />

The ACVA / ACVBA series are <strong>self</strong>-<strong>contained</strong> <strong>vertical</strong> <strong>compact</strong> <strong>units</strong> suitable for connection <strong>to</strong> an <strong>air</strong> duct distribution system<br />

both on indoor and outdoor sections.<br />

Suitable applications<br />

Commercial premises, banking offices, supermarkets, etc.<br />

Main features<br />

·<br />

Cooling<br />

installation kit.<br />

capacities ranging from 9.8 <strong>to</strong> 78.6 kW<br />

·<br />

Scroll Compressors<br />

·<br />

2 cooling circuits (models 1402 - 2402)<br />

·<br />

Optional outdoor<br />

Possible <strong>air</strong> supply / return configurations<br />

Standard<br />

Optional<br />

STD CONF. 1 CONF. 2 CONF. 3<br />

Rev. 100


SELF-CONTAINED VERTICAL AIR-TO-AIR COMPACT UNITS<br />

ACVA / ACVBA<br />

TECHNICAL SPECIFICATIONS<br />

MODEL 351 401 501 701 721 751<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Total power input - cooling<br />

Total power input - heating<br />

Power supply (50 Hz~)<br />

Static pressure<br />

Dimensions (length x width x height)<br />

Net weight<br />

kW 9,8 12,5 14,3 18,9 19,6 22,7<br />

kW 10,4 13,8 15,0 20,0 21,0 23,9<br />

kW 4,6 5,7 7,3 8,4 9,3 10,9<br />

kW 4,2 5,1 6,5 7,9 8,2 10,3<br />

V 230.3 ó 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N<br />

m 3 /h - Pa 2315 - 43 2600 - 50 3540 - 60 4720- 55 4720- 55 5133 - 53<br />

mm 937x750x1603 937x750x1603 1087x750x1603 1130x800x1900 1130x800x1900 1130x800x1900<br />

Kg 251 276 290 367 392 423<br />

MODEL 801 1001 1201 1402 1502 1602<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Total power input - cooling<br />

Total power input - heating<br />

Power supply (50 Hz~)<br />

Static pressure<br />

Dimensions (length x width x height)<br />

Net weight<br />

kW 24,2 30,1 34,9 37,8 49,6 50,2<br />

kW 25,3 31,7 38,2 39,5 51,2 51,9<br />

kW 10,9 13,4 14,4 16,6 19,8 20,8<br />

kW 9,6 12,4 13,2 15,9 17,5 18,6<br />

V 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N 400.3+N<br />

m 3 /h - Pa 5125-83 6277-73 8000-91 8000-130 10000-145 10000-145<br />

mm 1130x800x1900 1700x870x1900 1700x870x1900 2000x939x1997 2000x939x1997 2000x939x1997<br />

Kg 440 553 558 730 810 820<br />

MODEL 2002 2302 2402<br />

Nominal cooling capacity<br />

Nominal heating capacity<br />

Total power input - cooling<br />

Total power input - heating<br />

Power supply (50 Hz~)<br />

Static pressure<br />

Dimensions (length x width x height)<br />

Net weight<br />

kW 63,1 73,6 78,5<br />

kW 65,5 81,9 81,9<br />

kW 27 28,3 34,2<br />

kW 17,5 18,6 23,7<br />

V 400.3+N 400.3+N 400.3+N<br />

m 3 /h - Pa 11000-175 12000-160 12000-160<br />

mm 2600x980x2174 2600x980x2174 2600x980x2174<br />

Kg 1080 1115 1135<br />

THERMOSTATS AND CONTROLS<br />

THERMOSTATS<br />

RTR 7007/7035<br />

DSL<br />

Optional ETN<br />

Optional ARIA<br />

For models<br />

351 - 501<br />

701 - 2402<br />

All models<br />

“<br />

e<br />

Included in unit price<br />

“<br />

Available on request<br />


SELF-CONTAINED VERTICAL AIR-TO-AIR COMPACT UNITS<br />

ACVA / ACVBA<br />

ACCESSORIES<br />

Hot water heating coil (only models ACVA - cooling only)<br />

Coils of two rows and ribbed aluminium fins, suitable for mounting on<strong>to</strong> the <strong>air</strong> intake of models 351, 401 and 501 or inside the cabinet of all other<br />

models. The following table lists the recommended models by capacity.<br />

MODEL<br />

351<br />

401<br />

501<br />

701-721-751-801<br />

1001-1002-1201<br />

1002<br />

1402<br />

1502<br />

2002<br />

2302<br />

2402<br />

CAPACITY<br />

13,7<br />

17,2<br />

26,1<br />

34,8<br />

58,1<br />

58,1<br />

64,0<br />

69,8<br />

98,5<br />

100,0<br />

103,5<br />

AIRFLOW<br />

2100<br />

2300<br />

3000<br />

4000/4200/4600/5000<br />

6800/7000/7800<br />

7000<br />

8200<br />

8800<br />

11200<br />

12000<br />

12400<br />

WATER<br />

FLOW<br />

1180<br />

1480<br />

2250<br />

3000<br />

5000<br />

4990<br />

5500<br />

6000<br />

8470<br />

8600<br />

8900<br />

CONNECTION<br />

DIAMETER<br />

kW m 3 /h l/h Ø (") e<br />

3/4<br />

3/4<br />

1<br />

1 1/4<br />

1 1/2<br />

1 1/2<br />

1 1/2<br />

1 1/2<br />

2<br />

2<br />

2<br />

Available on request<br />

“<br />

“<br />

“<br />

“<br />

“<br />

“<br />

“<br />

“<br />

“<br />

“<br />

Auxiliary electric heaters<br />

Two stage heaters made up of nichrome wire heating elements. Including activation contac<strong>to</strong>r and terminal block for connection.Suitable for mounting on<strong>to</strong> the unit’s<br />

discharge side.<br />

MODEL CAPACITY POWER SUPPLY (50 Hz~)<br />

kW V e<br />

351 4 230.1 - 230.3 or 400.3+N Available on request<br />

351, 401 6 230.3 or 400.3+N “<br />

401, 501 9 230.3 or 400.3+N “<br />

501 12 230.3 or 400.3+N “<br />

701, 801 13,5 230.3 or 400.3+N “<br />

801, 1201 18 230.3 or 400.3+N “<br />

1001, 1502 22,5 230.3 or 400.3+N “<br />

1502, 1602 27 230.3 or 400.3+N “<br />

1602, 2002 31,5 230.3 or 400.3+N “<br />

2002, 2302, 2402 36 230.3 or 400.3+N “<br />

Head pressure control<br />

Models 201 - 501: The Head Pressure Control operates by adjusting<br />

the speed of the fan according <strong>to</strong> the pressure variations detected in the<br />

Refrigerant in the compressor output line (For cooling cycle operation at<br />

outdoor temperatures below 18 °C).<br />

Models 701 - 1201: The Head Pressure Control consists of dampers installed<br />

on the discharge of the fan on the outer side, which are activated<br />

by a modulating actua<strong>to</strong>r governed by a pressostatic control system. (For<br />

cooling cycle operation at outdoor temperatures below 18 °C).<br />

COOLING ONLY MODEL<br />

€<br />

351 Available on request<br />

401 - 801 “<br />

1001 - 1502 “<br />

2002 - 2402 “<br />

HEAT PUMP MODEL<br />

€<br />

351 Available on request<br />

401 - 801 “<br />

1001 - 1201 “<br />

1402 - 1602 “<br />

2002 - 2402 “<br />

Anti-corrosion pre-treated coils<br />

Blue fin treatment for coils.<br />

Copper - copper coils<br />

OTHER ACCESSORIES<br />

- Compressor sound jacket.<br />

- Free cooling.<br />

- Outdoor installation kit.<br />

- Anti-freeze heater for collection tray.<br />

- G4 and F6 - F9 filters.<br />

- Upgraded mo<strong>to</strong>rs.<br />

- Compressor soft start.<br />

- Condenser filter.<br />

- Hot gas bypass.<br />

- Alarm indication.<br />

- Head pressure control by frequency regula<strong>to</strong>r.<br />

- Service valves.