Analytical Solution of Gauss's Law<br />
5 th step<br />
Evaluation of maximum electric field strength E max<br />
Optimization (e.g. minimization of electrical field strength E max )<br />
R<br />
U<br />
Emax = E( R)<br />
= U = R<br />
2 R<br />
1<br />
E/E max<br />
0<br />
R<br />
r<br />
<strong>Fachgebiet</strong><br />
<strong>Hochspannungstechnik</strong><br />
High-Voltage Technology / Chapter 6 - 15 -