21.01.2014 Views

RUTA Roots Blower Vacuum Systems - Ideal Vacuum Products

RUTA Roots Blower Vacuum Systems - Ideal Vacuum Products

RUTA Roots Blower Vacuum Systems - Ideal Vacuum Products

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Technical Data, 50 Hz<br />

<strong>RUTA</strong><br />

501/SP250/A 1001/SP250/A 2001/SP630F/A<br />

501 1001 2001<br />

RUVAC (WA/WAU/WS/WSU possible) P2<br />

Outlet port DN 2 63 ISO-K 63 ISO-K 100 ISO-K<br />

Backing pump SCREWLINE<br />

P1<br />

SP250 SP250 SP630 F<br />

Pumping speed, 50 Hz at 10 -1 mbar<br />

(7.5 x 10 -2 Torr) m 3 x h -1 (cfm) 445.0 (262.1) 830.0 (488.9) 1745.0 (1027.8)<br />

Ultimate total pressure<br />

without gas ballast<br />

mbar (Torr) < 1 x 10 -3 (< 7.5 x 10 -4 ) < 1 x 10 -3 (< 7.5 x 10 -4 ) < 1 x 10 -3 (< 7.5 x 10 -4 )<br />

Installed motor power 400 V, 50 Hz kW (hp)<br />

9.7 (13.2) 11.5 (15.6) 22.5 (30.6)<br />

Electrical power consumption<br />

at 10 -1 mbar (7.5 x 10 -2 Torr) kW (hp)<br />

6.3 (8.6) 6.7 (9.1) 12.0 (16.3)<br />

Noise level to DIN 45 635 with silencer<br />

at 10 -1 mbar (7.5 x 10 -2 Torr) dB(A)<br />

75 77 79<br />

Total weight with palette, approx. kg (lbs) 720.0 (1589.4) 850.0 (1876.4) 1100.0 (2428.3)<br />

Connecting flange<br />

Inlet port DN 1<br />

63 ISO-K 100 ISO-K 160 ISO-K<br />

Ordering Information<br />

RUVAC (WA/WAU/WS/WSU possible)<br />

Backing pump SCREWLINE<br />

P2<br />

P1<br />

<strong>RUTA</strong><br />

501/SP250/A 1001/SP250/A 2001/SP630F/A<br />

WAU 501 WAU 1001 WAU 2001<br />

SP250 SP250 SP630 F<br />

Pump system, complete (adaptor version),<br />

without pallet,<br />

with <strong>Roots</strong> pump RUVAC WAU<br />

with air cooled SCREWLINE SP630<br />

pallet mounted,<br />

with <strong>Roots</strong> pump RUVAC WAU<br />

with air cooled SCREWLINE SP630<br />

Frequency inverter RUVATRONIC<br />

(see description in Section<br />

“Accessories”)<br />

Part No. 502 465 V001 Part No. 502 467 V001 Part No. 502 471 V001<br />

– – Part No. 502 471 V002<br />

Part No. 502 466 V001 Part No. 502 468 V001 Part No. 502 472 V001<br />

– – Part No. 502 472 V002<br />

RT 5/501 RT 5/1001 RT 5/2001<br />

Part No. 500 001 382 Part No. 500 001 383 Part No. 500 001 384<br />

Pressure<br />

10 3<br />

mbar<br />

10 2<br />

10 1<br />

10 0 8<br />

6<br />

4<br />

2<br />

10 -1<br />

0<br />

2 4 6 8<br />

Pump-down time<br />

WAU 501 + SP250<br />

WAU 1001 + SP250<br />

WAU 2001 + SP630F<br />

10 12 14 16 18 min<br />

750<br />

Torr<br />

10<br />

10<br />

10<br />

10<br />

2<br />

1<br />

0<br />

-1<br />

10 4 5000<br />

m 3 . h -1<br />

cfm<br />

1000<br />

10 3<br />

500<br />

WAU 501 + SP250<br />

100<br />

10 2<br />

WAU 1001 + SP250<br />

WAU 2001 + SP630F 50<br />

10<br />

10 1<br />

2 4 68<br />

10 -4 10 -3 10 -2 10 -1 10 0 10 1 10 2 mbar10 3<br />

Pressure<br />

Pumping speed<br />

-4 -3<br />

-2<br />

1<br />

0<br />

10 10 10 10 10 10 1 Torr 750<br />

Pump-down time diagram for a 10 m 3 tank at 50 Hz<br />

Pumping speed diagram at 50 Hz<br />

Oerlikon Leybold <strong>Vacuum</strong> Full Line Catalog<br />

17<br />

C08

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!