lTA-6.13A<br />

Figure 5-22. Using a Shaft Sleeve to Install the Radial Shaft Seal into the Front End Plate (D2A Pump Model Shown)<br />

Step F-6 k (Cont'd.)<br />

REQUIRED ACTION: Install the radial shaft seal (45) into the front end plate (44) as follows:<br />

(1) Insert the seal using one of the following methods.<br />

Method (a) - Insert a shaft sleeve over the shaft (see Figure 5-22); slide the seal (45)<br />

over the shaft sleeve and insert the seal into its slot in the front end plate; remove the<br />

shaft sleeve from the shaft.<br />

or<br />

Method (b) - Place cellophane tape over the shaft to prevent the seal from being cut or<br />

nicked; carefully slide the seal (45) over the shaft and insert the seal into its slot in the<br />

front end plate; remove the tape from the shaft.<br />

(2) Recess the seal (45) using one of the following methods.<br />

Method (a) - Slide a seal driver over the shaft; using a hammer, strike the seal driver to<br />

indent the seal into its slot in the front end plate; remove the seal driver from the shaft<br />

(see Figure 5-22).<br />

or<br />

Method (b) - Slide the used seal over the shaft until it is against the new seal; using.a<br />

hammer, tap evenly around the used seal to indent the new seal into its slot in the front<br />

end plate; remove and discard the used seal.<br />

F-7 NOTE: The end of the air inlet tube with the beveled tip and circumferential slots is the outside end (see Figure<br />

5-4).<br />

Install the air inlet tube (69) into the module as follows (see Figure 5-4):<br />

a. Push the air inlet tube through the hole in the top of the front end plate (44). When installed<br />

.. properly, two of the three circumferential slots in the end of the air inlet tube should extend out<br />

of the outside surface of the front end plate (44).<br />

b. Insert the retainer disk (71) into the second slot from the beveled tip of the air inlet tube (69).<br />

NOTE: The other end of the air inlet tube (69) fits into the hole in the base of the intake portion of the high<br />

vacuum pump cylinder (55) (see Figure 5-4).<br />

F-8 CAUTION: USE CARE WHEN HANDLING THE MODULE TO AVOID BENDING THE LEVER (41) OR<br />

CENTRIFUGAL SWITCH (39). (This CAUTION also applies to Steps F-9 through F-12.)<br />

Repeat Steps C-9, C-6, C-5, C-4, and C-3, except assemble rather than disassemble.<br />

40 <strong>TRIVAC</strong> "A" Manual, Edition L