COMBI 200: use and maintenance<br />
<br />
___________________________________________________________________________________________________________________<br />
<br />
<br />
The appendix contains the diagrams for the various units present in the<br />
machine and the reference drawings. This section also contains the<br />
documentation for the components installed in the machine and referred to in<br />
the manual.<br />
<br />
For wiring, the operator must consult the diagrams below<br />
S1<br />
C1<br />
X1<br />
PE<br />
N<br />
L1<br />
M1<br />
M2<br />
Control switch<br />
Capacitor<br />
Disk motor connector<br />
Overload line conductor<br />
Neutral line conductor<br />
Phase line conductor<br />
Disk motor<br />
Pump motor<br />
<br />
Fig.5.1<br />
<br />
<br />
<br />
<br />
<br />
When the start switch is pressed, the motor − No mains voltage.<br />
does not start<br />
− The plug and socket are not connected − Check the mains.<br />
properly.<br />
− The power supply cable is disconnected − Reset the correct connection.<br />
from the cabinet.<br />
− An electric wire inside the motor terminal − Replace the cable.<br />
board is disconnected.<br />
− Contact an electrician for assistance.<br />
− An electric wire inside the cabinet is − Contact an electrician for assistance.<br />
disconnected.<br />
− The mains switch is faulty.<br />
− Change the switch.<br />
No cooling water for the disk. − Consult machine cleaning, section 4.2 ,and tank cleaning, section 4.5<br />
The disk does not cut. − Incorrect disk rotation direction.<br />
− Dismantle the disk and reposition it in the<br />
direction indicated on the disk label.<br />
− Worn disk.<br />
− Fit a new disk.<br />