WARNING Electrical shock hazard — can cause severe injury or death. Disconnect<br />

power before installing or servicing.<br />

NOTICE Burners with Beckett Clean Cut Pump must be used with a primary control<br />

that has a valve-on delay (pre-purge). Controls shown have valve on delay<br />

(see control manufacturer’s instructions for timings.)<br />

NOTES:<br />

1. All wiring must be installed in accordance with N.E.C. and any other national,<br />

state, or local code requirements. For Canadian installations, all wiring must<br />

comply with the Canadian Electrical Code.<br />

2. All wiring must be N.E.C. Class 1.<br />

3. Refer to control component instructions packed with the boiler for application<br />

information.<br />

4. If any of the original wire as supplied with the appliance must be replaced, use<br />

minimum 105 °C wire or equivalent.<br />

5. Nozzle line heater is standard on Carlin EZ burners. Leave wire capped and unattached<br />

if not used.<br />

6. Set thermostat heat anticipator as per control manufacturer’s<br />

recommendations.<br />

7. Connect incoming line voltage "HOT" wire to service switch and neutral wire<br />

to white wire. Connect ground wire to green wire with wire nut.<br />

Low Limit Setting:<br />

WGO - Set to “OFF”<br />

<strong>WTGO</strong> - Set Low Limit Temperature<br />

THERMOSTAT<br />

(NOTE 6)<br />

SERVICE<br />

SWITCH<br />

120 VAC<br />

(NOTE 7)<br />

L1<br />

L2<br />

T<br />

T ZR<br />

ZC<br />

B1<br />

B2<br />

C1<br />

C2<br />

BL<br />

CIRCULATOR<br />

HARNESS<br />

CIRCULATOR<br />

Y<br />

HOT<br />

N<br />

G<br />

EQUIPMENT<br />

GROUND<br />

(NOTE 7)<br />

W<br />

G<br />

BK<br />

W<br />

G<br />

BK<br />

W<br />

Y<br />

BL<br />

JUNCTION BOX<br />

120 VAC FIELD WIRING<br />

BK<br />

LOW VOLTAGE FIELD WIRING<br />

120 VAC FACTORY WIRING<br />

LOW VOLTAGE FACTORY WIRING<br />

1/4” QUICK CONNECT TERMINAL<br />

R<br />

WGO<br />

• Water without tankless heater<br />

2 thru 9<br />

SPILL SWITCH<br />

(REQUIRED FOR<br />

CANADIAN<br />

INSTALLATION)<br />

ADDITIONAL<br />

TEMPERATURE<br />

LIMIT CONTROL<br />

(WHEN USED)<br />

LIMIT<br />

CONTROL<br />

HARNESS<br />

BK<br />

W<br />

BURNER<br />

HARNESS<br />

PK<br />

BURNER<br />

DISCONNECT<br />

G<br />

POSITION<br />

KEY<br />

<strong>WTGO</strong><br />

3 thru 9<br />

POSITION<br />

KEY<br />

TO<br />

BURNER<br />

DISCONNECT<br />

ON BOILER<br />

BURNER WIRING<br />

BK<br />

POSITION<br />

KEY<br />

TO<br />

BURNER<br />

DISCONNECT<br />

ON BOILER<br />

PK<br />

WGO<br />

<strong>WTGO</strong><br />

HEATER<br />

(NOTE 5)<br />

BURNER WIRING<br />

POSITION<br />

KEY<br />

TO<br />

BURNER<br />

DISCONNECT<br />

ON BOILER<br />

BK<br />

PK<br />

G<br />

W<br />

R<br />

BK<br />

BURNER WIRING<br />

PRIMARY<br />

CONTROL<br />

SUB-BASE<br />

L<br />

G<br />

N<br />

G<br />

BURNER<br />

GROUND<br />

SCREW<br />

G<br />

W<br />

W<br />

PK<br />

PK<br />

W<br />

BK<br />

• Water with tankless heater<br />

X<br />

X<br />

AUX.<br />

SOLENOID<br />

VALVE<br />

BURNER<br />

MOTOR<br />

Carlin 60200 Primary Control<br />

BURNER<br />

JUNCTION<br />

BOX<br />

BK<br />

SOLENOID VALVE<br />

BK<br />

W<br />

TRANSFORMER<br />

/IGNITOR<br />

a<br />

BURNER<br />

MOTOR<br />

BURNER<br />

GROUND<br />

SCREW<br />

Riello 530 SE/C Primary Control<br />

L N X<br />

T<br />

DAMPER<br />

MOTOR 6-<br />

CB<br />

BK<br />

6-<br />

D BR<br />

A<br />

SOLENOID<br />

VALVE<br />

BK<br />

BK<br />

TRANSFORMER<br />

/IGNITOR<br />

6-<br />

11<br />

BL<br />

BURNER<br />

JUNCTION BOX<br />

BURNER PRIMARY<br />

CONTROL<br />

BK<br />

R/W<br />

W<br />

O<br />

V<br />

BL<br />

11<br />

9<br />

7<br />

3<br />

10<br />

8<br />

6<br />

5<br />

4<br />

2<br />

1<br />

BURNER PRIMARY<br />

CONTROL<br />

<strong>Weil</strong>-<strong>McLain</strong> 500 Blaine St. Michigan City, IN 46360-2388<br />

PART NUMBER 550-200-018 0108<br />

T<br />

T<br />

F<br />

F<br />

BR<br />

W<br />

BL<br />

BURNER<br />

MOTOR<br />

BK<br />

A<br />

B C<br />

D<br />

a CAD cell flame detector<br />

b Jumper these T-T terminals.<br />

Connect thermostat to boiler<br />

high limit.<br />

c Low voltage alarm circuit<br />

Beckett R7184P Primary Control<br />

R<br />

BK<br />

W<br />

W<br />

W<br />

W<br />

V<br />

BL/W<br />

O<br />

Y<br />

LIMIT<br />

L1<br />

L2<br />

L2<br />

L2<br />

L2<br />

VALVE<br />

IGNITOR<br />

MOTOR<br />

T<br />

T<br />

Y<br />

BURNER PRIMARY<br />

CONTROL<br />

a CAD cell flame detector<br />

(terminals on bottom of control)<br />

b Jumper T-T terminals if resistor<br />

c has been cut. Connect<br />

thermostat to boiler high<br />

limit.<br />

c Resistor acts as internal T-T<br />

jumper.<br />

Y<br />

Y<br />

b<br />

c<br />

b<br />

a<br />

c<br />

Part Number 550-141-983 0108<br />

Page 3